Functional specification and risk assessment

Similar documents
SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Wireless Keypads LKP(E)S8M Series

Wireless Keypad GKP-S8M

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

U.S. Consumer Product Safety Commission Washington, DC 20207

Total Connect Box. User manual

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

ElkGuard. Owner's Manual. Self-Contained Wireless Security System. ElkGuard

THE FUTURE OF FIRE SUPPRESSION

NZQA registered unit standard 5897 version 3 Page 1 of 5. Design electronic security intruder alarm systems

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

SECURE LIFE SAFETY PAGA

Property Health and Safety Compliance at Housing and Education Centres

ADVISOR CD User Manual. Software from version: V

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Remote Relay Module (RRM)

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

USER S MANUAL. VKP Series INLINE FAN

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual

Edgeline was formed in 2010 with the intention of becoming a market leader in the design, manufacture, and sales of electrical / electronic /

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Model 4001 Series Single Channel Controller

Important Safety Notice

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018

Safety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR

Section PERIMETER SECURITY SYSTEMS

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

5000 SERIES 8 ZONE INSTRUCTION MANUAL

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

IDM4 CARAVAN ALARM. Operating instructions

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

IMR IX176 Portable Gas Detector User Manual

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

1. Package content. User Manual v1.3

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

670T INSURANCE APPROVED CAN BUS ALARM (ORIGINAL REMOTE CONTROL UPGRADE) USER GUIDE

The Dangers of Heat Stress

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Quick Touch Pendant User Guide

Proximity Detection Systems. Reliable, proven solutions for mining safety

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Consultant Specification AGILE Wireless Fire Detection System

TH450A-CRB TH550A-CRB THP550-CRB/TS3000

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

Lata Mishra Bhabha Atomic Research Centre, INDIA

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Di-440 The Modular Analyser

Part No KEMPER Filter-Master XL

HILLS Series LED Code Pad User Manual

APC BC300 Series 40kW 208/450/480V User Guide

Emergency Voice Communication System (EVCS) Consu ltant s Specific atio n CONTENTS

IMR EX610. Portable Gas Detector. Operation Manual

E1000 Portable gas detector

POP_ Smoke Detector

Functional Performance Test

Fire Detection and Activation System Model Rev 2.1

Material Safety Data Sheet

Z-1500II and Z-3000II USER MANUAL Z-1500II und Z-3000II BEDIENUNGSANLEITUNG Mode D Emploi des Z-1500II et Z-3000II Machines à Fumée

Сontrol panel Contact GSM-9N

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

SECTION INTRUSION DETECTION

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

AMX 68 Owner's Manual 12/29/97

Automatic Lamp & Mat Heating Control

Version 1.03 January-2002 USER S MANUAL

User s Information Guide R2A

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

General safety precautions English

POP_ Smoke Detector

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Stench Gas Systems. MineARC Stench Gas is an emergency alert system, designed to suit noisy locations where alarms cannot be heard.

Z-800II / Z-1000II / Z-1020 Fog Machine User Manual

1. CONTENTS OF PACK 2. TECHNICAL SPECIFICATIONS ... User Manual v1.1. Compatible with: ESIM264 v and up. ESIM364 all versions

Annexure - 1. Detectors: Fire Alarm Control Panel :

General safety precautions English

DCSS (ACB) Data Center Fire Suppression Procedures

ELECTRONIC SOUNDER STROBE Model : AVD-C407

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Solicitation Requirements Matrix

FEB 15 Rev C

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Bold items are particular to the City of Euless

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

SECTION LOW VOLTAGE LIGHTING CONTROLS

SECTION INTERIOR LIGHTING

FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters

EMEX 110 and EMEL. EMEX 110 and EMEL. 110, 50 and 24 volt AC/DC Central Battery Systems. EMEX 110 and EMEL

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

Manhattan Fire Protection District

National Broadband Network. User Guide. Includes important information about your NBN equipment

Transcription:

Functional specification and risk assessment Refuge Bay Emergency Indicator DOCUMENT DETAILS Project Title: Refuge Bay Emergency Indicator Document Number: RBEI_FSRA_0_01 System/Subsystem Title: Document Issue Date: 2010/05/03 Client Reference: NA APPROVAL Checked by Name Signature Date Author Mr GPR van der Merwe 2010/05/05 QA: Prof JEW Holm 2010/05/05 Technical Approval Mr GPR van der Merwe 2010/05/05 Project Manager Mr Martiens Visser 2010/05/05 PAGE 1 OF 15

Table of Contents 1 SCOPE... 3 1.1 PURPOSE... 3 1.2 IDENTIFICATION... 3 2 PRODUCT DEFINITION... 4 2.1 PRODUCT DEFINITION... 4 2.2 SYSTEM PRIMARY FUNCTIONS... 4 2.2.1 Primary mission... 4 2.2.2 Secondary functions... 4 2.3 SYSTEM AND COMPONENT ARRANGEMENT DIAGRAMS... 4 2.3.1 System arrangement... 4 2.3.2 System components... 4 2.4 INTERFACES... 6 2.4.1 Interface 1 Power cable... 7 2.4.2 Interface 2 Maintenance performed by a technician... 7 2.4.3 Interface 3 Miner indication and operation... 7 2.4.4 Interface 4 Environmental hazards... 7 2.5 CHARACTERISTICS... 8 2.5.1 Functional characteristics... 8 2.5.2 Performance characteristics... 10 2.6 QUANTIFIED RISK ANALYSIS... 12 2.6.1 Refuge bay Emergency Indicator Risk Matrix... 13 3 QUALITY ASSURANCE PROVISIONS... 14 3.1 MANUFACTURING... 14 3.1.1 Documentation... 14 3.1.2 Tests... 14 3.2 INSTALLATION, OPERATION, AND MAINTENANCE... 14 3.2.1 Documentation... 14 3.2.2 Tests... 14 4 CONFIGURATION CONTROL... 15 PAGE 2 OF 15

1 SCOPE 1.1 Purpose This specification establishes the performance, design, test, manufacture, and acceptance characteristics and requirements for the Refuge Bay Emergency Indicator. 1.2 Identification This document is comprised of the following sections: 1. Section 2: Product definition 2. Section 3: Quality assurance provisions 3. Section 4: Configuration control PAGE 3 OF 15

2 PRODUCT DEFINITION 2.1 Product definition The Refuge Bay Emergency Indicator is used to indicate the location of the refuge bay during emergency situations. The unit consists of four multicolour bezels, a siren and battery backup. 2.2 System primary functions 2.2.1 Primary mission The primary mission of the refuge bay emergency indicator is to provide visual and audible indication of the refuge bay during emergency situations. 2.2.2 Secondary functions Apart from indicating the location of the refuge bay, the following functions are supported by the system: 1. The refuge bay emergency indicator consists of a battery backup unit to ensure operation for at least 20 hours when no power is available; 2. Four multicolour bezels are used to provide efficient visual indication; 3. An multi-tone siren is used for audible indication; 4. The refuge bay emergency indicator provides a robust and water proof enclosure. The enclosure can also be locked to limit possible tampers to the system. 2.3 System and component arrangement diagrams This sub-section incorporates the functional schematic and flow diagrams of the system. Applicable layout drawings that establish the general relationship of major components are included. 2.3.1 System arrangement The refuge bay emergency indicator should be located just outside the refuge bay to indicate the location of refuge bays, especially during emergency situations. 2.3.2 System components The system consists of a single module. This module is illustrated in figure 1. PAGE 4 OF 15

1: Voltage Specification 8: Multicolour Bezels 2: Square Key Lock 3: Tamper Lock 4: Siren 5: Override Switch 6: Power Cable 7: Mounting Bracket FIGURE 1 Figure 1 shows the graphical representation of the refuge bay emergency indicator. The unit consists of the following components: 1. Voltage specification: This shows the voltage requirement for the system. See section 2.4.1 for possible voltage specifications; 2. Square Key Lock: A square key is required to lock and open the enclosure; PAGE 5 OF 15

3. Tamper Lock: The system can be locked to prevent tampering with the system; 4. Siren: The siren is used to sound during emergency situations; 5. Override switch: The override switch can be used to force the system into the emergency state, if the power is not tripped; 6. Power cable: A two meter long power cable is used to supply power to the system; 7. Mounting Bracket: The system can be mounted with this bracket; 8. Multicolour Bezels: Four multicolour (red / green) bezels are mounted on the sides of the refuge bay emergency indicator. These bezels indicate the states of the system. 2.4 Interfaces A basic interconnection diagram (see Figure 2) below shows the interface arrangement of the refuge bay emergency indicator: Technician Interface 2 Miner Power Supply Interface 1 Refuge Bay Emergency Indicator Interface 3 Interface 4 Environment (Hazards) FIGURE 2 INTERFACES The main interfaces are shown above. These are described as follows: 1. Interface 1 An interconnecting power cable between the refuge bay emergency indicator and the power source; 2. Interface 2 This is the interface between the technician and the RBEI system; 3. Interface 3 This interface consists of the audible and visual indication to the miners in the area. The miner should also operate the override switch if necessary; 4. Interface 4 This interface describes the environmental hazards that can affect the system. PAGE 6 OF 15

Each of the interfaces shall be described in the following sections. 2.4.1 Interface 1 Power cable Various input voltages can be specified to power the system. These voltages are as follows: 110V AC; 220V AC; 525V AC; These different configurations are possible but have to be defined and specified - the current product only covers the above ranges. It is important that the correct power source specification is provided before a unit is supplied and installed. It is the responsibility of the mine to specify the required voltage. 2.4.2 Interface 2 Maintenance performed by a technician The system should be tested and maintained regularly in order to ensure proper operation. The outputs (bezels and siren) should be tested together with the status of the batteries. If the batteries are faulty, they should be replaced due to their limited lifetime. 2.4.3 Interface 3 Miner indication and operation Visual indication is provided by the four bezels, located on the four sides of the system. This allows for visibility in all directions. Audible indication is by means of a siren. This interface also includes the override switch which should be activated (if the system is still in the safe state) by the first miner entering the refuge bay during an emergency situation. Generally the mains power will be tripped during emergency situations, which will force the system into the emergency state. 2.4.4 Interface 4 Environmental hazards The main hazard to the system would be direct fire, but should the system be installed at the correct location in order to minimize this hazard. PAGE 7 OF 15

2.5 Characteristics This section describes the functions of the refuge bay emergency indicator in terms of its operational modes. Where required, a function s performance, physical or other characteristics are given. 2.5.1 Functional characteristics 2.5.1.1 Modes of operation The modes of operation for the refuge bay emergency indicator are shown in the following state diagram: 1. SAFE INDICATION Bezel: Green Siren: Off Power or Battery Change POWER and Overide Switch Disabled POWER or Overide Switch Enabled 3. BATTERY FLAT / FAULTY Bezel: Off Siren: Off Battery Flat or Battery Fault 2. EMERGENCY INDICATION Bezel: Flashing Red Siren: On FIGURE 3 STATE DIAGRAM 1. Safe indication: When power is supplied to the refuge bay emergency indicator and the override switch (see unit 5, Figure 1) is disabled the system will be in this state. The four bezels will be GREEN while the buzzer will be off. During this state the backup batteries will also be charged. The batteries should charge to a maximum within 4 hours; PAGE 8 OF 15

2. Emergency indication: If power is removed from the system or the override switch is enabled the system will exit the safe state and enters the emergency state. During this state the bezels will be flashing RED while the siren will sound. During this state the backup battery will be used to supply power to the system. This state will last at least 20 hours (if the batteries were fully charged) before the batteries will be flat and the system will enter state 3. The batteries will be automatically recharged once the system enters state 1 (Safe indication). 3. Battery flat / faulty: During this state no power is available to operate the system in state 2. In this state the bezels together with the siren will be off. The exit condition to this state would be when power is restored or when the batteries are replaced when necessary. 2.5.1.2 Failure modes Different failure modes have been identified for the system. The effect of these failure modes can also be seen in the risk analysis done in section 2.6. These failure modes are as follows: 1. External cable fault: If the power cable is faulty, no power will be supplied to the system. The batteries will run out after which the system will fail. This is a total module failure; 2. External over voltage: If the incorrect voltage is supplied to a unit, the internal fuse will blow and needs to be replaced at the factory - this fault should only occur when very high voltage surges occur; 3. Backup power failure: Lead acid batteries are used to supply backup power. These batteries need to be maintained and replaced when necessary. The backup battery should be replaced at least every two years, depending on the charge / discharge cycles of the system. 4. Bezel and Siren (Indicators): Both operational modes of the bezels (RED and GREEN) together with the siren should be tested regularly to ensure operation. 5. Internal module fault: This is a total module failure and can only be detected by testing the module before use. 6. Visibility Failure (wrong installation): The location of the system installation should be of such to ensure maximum visibility of the system state to the surrounding areas. 7. Environmental Hazard: Possible environmental factors might affect the operation of the system. Direct fire might damage the system. PAGE 9 OF 15

2.5.2 Performance characteristics 2.5.2.1 Durability Various factors influence durability, including use factors. However, components in the system were designed to provide durability in a number of ways: 1. The mechanical design was done to provide a strong robust enclosure; 2. Electronics are conformally coated to provide protection against the ingress of water and other particles; 3. Electronics were designed with operational margins of more than 50% on input and output protection the electrical power inputs are protected against over-voltage and over-current conditions. 2.5.2.2 Health and safety Although all possible steps were taken from a design point of view to ensure safety, the following aspects are of high importance: 1. Procedures must be put in place to test for explosive gasses before any system is powered up; 2. Lead acid batteries are used within the system. The internal components of these batteries include lead and liquid electrolyte. The potential risks for these substances are as follows: Electrolyte: Electrolyte is corrosive and contact may cause skin irritation and chemical burns. Electrolyte causes severe irritation and burns of eyes, nose and throat. Ingestion can cause severe burns and vomiting. Lead: Direct skin or eye contact may cause irritation. Inhalation or indigestion of lead dust or fumes. This may also result in headache, nausea, vomiting, abdominal spasms, fatigue, sleep disturbances, anemia and leg, arm and joint pain. Note: These harmful substances internal to the batteries can be exposed during direct fire or explosion. Note that these batteries are located within the steel enclosure to limit possible exposure. 2.5.2.3 Maintainability and inter-operability A swap-out policy was followed for unscheduled maintenance. The following specific guidelines should be followed: 1. No component should be opened for second-line repairs on the premises of the client; 2. The swap-out policy was designed into the system and facilitates a drop-in replacement of similar-type modules. PAGE 10 OF 15

2.5.2.4 Transportability The refuge bay emergency indicator units will be exposed to harsh conditions and were designed with the following requirements: 1. Humans will carry the units. Therefore the enclosure is light-weight and small; 2. All units are transported in protective cardboard boxes and are protected against shock and vibration. 2.5.2.5 Materials processes and parts All materials used in the design were selected to withstand harsh underground conditions. Enclosures are manufactured from 3CR-12 stainless steel and powder coated to withstand all environmental conditions common to mines; 2.5.2.6 Modularity Units were designed to be modular and interchangeable inasfar as possible. This is to facilitate swap out and replacement on site as well as to reduce the skills level requirements on maintenance personnel in operation. 2.5.2.7 Standards of manufacture All electronic and mechanical sub-assemblies are manufactured / assembled in an ISO- 9000 facility. PAGE 11 OF 15

2.6 Quantified risk analysis The quantified risk analysis for the refuge bay emergency indicator is done in the following section. The risk ratings used is defined in the following table: Consequence Rating (CR) Rating 1 2 3 4 5 Explanation Near miss injury / Damage Disabling Injury Serious Injury Fatality Catastrophic / multiple fatalities Probability Rating (PR) - this is not a linear scale, please refer to the percentages. 1 2 3 4 5 Rating (<1%) (1% - 5%) (5% - 10%) (10% - 50%) (>50%) Explanation Practically Impossible Not likely to happen Could happen Has happened Common Risk Rating (RR) = Consequence x Probability 0 7 8 15 16 25 Low Medium High TABLE 1 : RISK RATING DEFINITION PAGE 12 OF 15

2.6.1 Refuge bay Emergency Indicator Risk Matrix The risk matrix below indicates risk identified within the system. Please note that the current risk can be significantly reduced by implementing the recommended controls as shown with the reduced risk option. Option 1 - Technical / Operational Risk Number Failure mode Consequence Additional controls No power to the system Develop test specification to test 1 Power cable fault 4 1 4 - System failure. the system regularly. External over voltage Implement protection done 2 System failure 4 2 8 condition in all units (as per design) CR PR with control RR without control CR PR with control RR with control 4 0.5 2 1 1 1 3 Backup battery failure No power to the system for EM indication - System failure. 4 1 4 Develop test specification to test the system regularly. Replace battery every 2 years. 4 0.5 2 4 Battery theft No power to the system for EM indication- System failure. 4 1 4 Ensure the system is locked to avoid tampers. 4 0.5 2 5 Bezel failure No visual indication of the state of the system. 2 1 2 Four bezels are used, connected in parallel. 2 0.5 1 6 Siren failure No audible indication of the state of the system. 2 1 2 Develop test specification to test the system regularly. 2 0.5 1 7 Incorrect installation Minimal to limited visibility to the surrounding area. 3 1 3 Installation documentation and sufficient training. 3 0.5 1.5 8 Environmental Hazard (Direct fire) System failure. 5 1 5 Ensure proper installation in a safe area. 5 0.5 2.5 9 10 Personnel training support system failure Maintenance and repair support system failure System failure. 5 3 15 System failure. 5 3 15 Ensure effective training documentation is available. Schedule additional maintenance and keep stock of the system components. 5 1 5 5 1 5 Unmitigated risk 62 Mitigated risk 23 PAGE 13 OF 15

3 QUALITY ASSURANCE PROVISIONS 3.1 Manufacturing 3.1.1 Documentation All manufacturing, assembly, and test documentation was done to control quality during manufacturing. Quality design, procurement, manufacturing and assembly, and test and inspection procedures are documented and enforced. 3.1.2 Tests The following tests are done during manufacture: 1. Component inspection before assembly; 2. Board-level testing is done to prevent infant mortality; 3. Assembly inspection is done; 4. Component-level testing is done; 5. Module-level testing is done; 6. Packaging inspection is done. 3.2 Installation, operation, and maintenance 3.2.1 Documentation Installation, operational and maintenance documentation is available to ensure quality use of the system. 3.2.2 Tests The following test procedures must be followed when utilizing the system: 1. Module inspection before installation; 2. First use inspection should be done on customer premises; 3. Replacement inspection and testing. PAGE 14 OF 15

4 CONFIGURATION CONTROL DOCUMENT HISTORY Issue Date Status Editor Filename on disk 1 2010/05/05 Released MSW RBEI Product Functional Specification and Risk Assesment V1.doc REVISION HISTORY Issue Date Changes 1 2010/05/05 Creation AUTHORISATION HISTORY Issue Date Status Reference 1 2010/05/05 Authorised GPR van der Merwe PAGE 15 OF 15