STR-600 Impact Dryer

Similar documents
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS

EH0533 Indoor Climate Control

Installation and use of Strong Central Vacuum Cleaning System

- Cooling - Heating - Dehumidifying - Fan. Please read this owner s Manual carefully before operating the unit. -1-

TOP AND CONSOLE PARTS

Installation plan: PG Mat. no Version 00 US

TECHNICAL SPECIFICATION

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

1.1. The unit shall be manufactured with quality, durability, and professionalism.

Meaco 20L medium home dehumidifier Instruction Manual. nergybulbs.co.uk. Meaco 20L Medium Home Dehumidifier

20 LITRE DEHUMIDIFIER

Drying Cabinet Installation and Operating Manual

DryFan 8. Pro. Pro INTERNATIONAL PATENT PENDING DEHUMIDIFIER USER MANUAL DryFan 8 (white) DryFan 12 (white)

User Manual. Model: FSL200 Laser Fume Extractor

FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

Strong Central Vacuum Cleaning System

CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS

Trotec PAC FT 2600 Portable air conditioner

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

Reverse Cycle Portable Air Conditioner with Dehumidifier

EWS-1500-T2 Deluxe Tower Heater USER MANUAL

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

Local Air Conditioner

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

Dual-Hose Portable Air Conditioner User Manual

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

- Murdoch University, Western Australia.

Operating Instructions Model #: Curved Front Electric Fireplaces

Heating and Air-Conditioning Testing II. Climatic Test Bench

Installation plan PG 8581 PG 8582 PG en - US

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

EH0554 Indoor Climate Control

Meaco 20L medium home dehumidifier Instruction Manual

Heat Pump / Air Conditioner

The specifications in this document are subject to change without notice. DFD - DH Series. Desiccant Flexible Dryer & Drying Hopper Systems

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Q1. The diagram shows the inside of a mains plug. Label the earth, live and neutral pins.

INSTALLATION INSTRUCTION

CANOPY RANGEHOOD OFFBOARD INSTALLATION INSTRUCTIONS

Outside Air Requirements... SOLVED!

ELECTRIC FIREPLACE HEATER MODEL EF-BLT09 OWNER S MANUAL

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/ Maytag Part No. W Rev. A

T-Series Air Conditioner T15 Model

MOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB

Installation and Maintenance Manual Please retain this manual for future reference.

T-Series Air Conditioner T53 Model

SAFETY AND INSTALLATION MANUAL MODEL 8100

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

Infrared Portable Space Heater

Manual. Atomizer Air Humidifiers. Type DG4 / DG8

OPERATING AND MAINTENANCE MANUAL

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

INSTALLATION &OPERATIONS MANUAL

Installation and User Manual. Model: IK35 (1151) TAPWARE RANGEHOODS COOKTOPS WASTE DISPOSALS

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Installation and Operating Manual Drying Cabinet

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

OPERATING AND MAINTENANCE MANUAL

27" GAS DRYER MODELS: 7MWGD87HEDC0 (Chrome Shadow) 08/19/ Whirlpool Corporation Part No. W Rev. A

CLIMATE CONTROL PRODUCT GUIDE

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

LAVA. Installation Manual. Design Glass-Radiator By WarmlyYours. Read all instructions before installing or using this heater.

Meaco 10L small home dehumidifier Instructional Manual

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DSR SERIES DEHUMIDIFIERS ENGLISH GENERAL INFORMATION EXPLODED VIEWS DSR-20 DSR-12 PARTS LISTS ATTENTION!

Dr. Infrared Heater Elite Series

irconcentre.co.uk airooncentre.co.uk

Installation Plan. Laboratory Glassware Washer. en US PG 8583 CD. M. Nr

User Manual. Model: FSL100 Laser Fume Extractor

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

MeacoDry ABC Range Dehumidifiers

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Thermal fuse 252+/ / / /-5 102C 102C 102C 102C

Instruction Manual WARNINGS

Refrigerated Air Dryers

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Portable Air Conditioner Instruction Manual

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Infrared Portable Space Heater

IMPORTANT SAFETY INSTRUCTIONS

5) Do not start or stop the unit by inserting or pulling out the power plug.

Service Manual for X9.5 and Older Models

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

VERNON ELECTRIC FIREPLACE

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Refrigerated Air Dryers

Instructions manual DEHUMID HP50

MPK-09CRN2 / MPK1-09CRN1 / MPK1-12CRN1 DE EN IT FR NL

ELECTRIC FIREPLACE INSERT MODEL EF-BLT10 OWNER S MANUAL

Important: Read all instructions and warnings carefully before starting installation. INSTALLATION INSTRUCTIONS GENERAL

Technical Description

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

Transcription:

STR-600 Impact Dryer 1. STR-600 Main Features The STR-600 is designed for moisture damage drying of targeted areas. The device can be used for drying various stone-based materials, such as concrete, brick and masonry. A single unit is best used for drying areas damaged by broken water pipe, such as bathrooms or kitchens. It is designed for drying areas sized from 1 to 10 m². Using multiple units simultaneously to cover larger damaged areas will effectively shorten the drying time. This capability is especially appreciated where shortest possible damage repair time is essential (i.e. hospitals, schools, power plants). The STR-600 can also be used in combination with common air dehumidifiers. In certain cases, these device types complete each other. The STR-600 s should be placed on areas with the worst moisture damages and the dehumidifier would handle the overall room space.

2. Principle of Operation Air circulated surface drying was invented in Finland in 1990 s. Since then this method and equipment have evolved far. The STR-600 brings the capabilities to a new level using most effective heating and air circulation system. The STR-600 is first placed on the damaged area after the surface materials are removed and the base concrete is visible. An air outlet hose is then connected onto the Ø 50 mm humid air outlet of the unit. In most cases, it is recommended to duct the humid air outside via the air outlet hose. If an air dehumidifier is used in the same space with the STR-600, ducting the air out may not be necessary. The unit s power cable is then connected to a power outlet and the device is switched On. Now, the air fan and heating elements start working. Ambient air (1.) is drawn in through the air intake filter (see below). Inside the unit, air flows past the heating elements. Air temperature increases and relative humidity goes down. This dramatically increases the capability to reduce moisture on the concrete surface. Simultaneously, the heating elements radiate heat downwards to the damaged surface, causing vaporization. Heated air is directed through the air distribution channels (2.) on each side of the bottom plate. The air blower (3.) in the middle of the bottom plate sucks the heated air effectively towards itself. On its way from each four sides to the middle, warm air sweeps the damp structure and the vaporized moisture is absorbed into the air. The continuous air circulating-drying effect starts to dry out the structure immediately and very effectively.

The humid air (4.) is then guided to the air outlet. A Ø 50 to 55 mm air hose can be connected onto the outlet if needed. 3. Additional Features The STR-600 is equipped with an automatic timer governing the drying/heating cycles. Alternating heating and cooling sequences causes the moisture in the base material to rise towards the upmost surface. It also prevents the material temperature from rising too high. The pre-set timing is 10 hours heating / 4 hours cooling. During cooling cycle, the fan runs continuously, while the heating elements are switched off. An indicator light is illuminated when the heating is on. A separate switch for bypassing the timer is included in the system. The bypass switch is used when drying very thick structures, i.e. a thick brick wall, and the aim is to raise the inside temperature of the structure as high as possible to get water to vaporize from the outer side of the structure as well. When the timer is bypassed, a red signal light is illuminated. The timer bypass switch should not be used for common floor drying etc. as

the structure s temperature may rise too much, which would slow down the drying process. 4. Main Advantages - FAST DRYING. Drying time is only a fraction of time compared to standard air dryers. A concrete slab with an average thickness of 8 to 10 cm can be dried in 5 to 10 days, compared to several weeks using common methods. - ENERGY SAVINGS. To dry out a 5,0 m² room with standard air dryers may take several weeks and consume power up to 4 kw per hour. Using 4 pcs of STR-600 units, the same area can be dried in 10 days with an average energy consumption of 2,4 kw per hour. A common moisture problem around bathroom floor drain is handled by a single STR-600 5 to 10 days with only 0,6 kw per hour energy consumption. The energy varies depending on the moisture content and thickness of the base material, but the time savings against conventional methods remain huge. - LOW NOISE. The noise level of STR-600 is very low. Living in the apartment surrounding damage area will not be disturbed. - SAFETY. The method is based on effective air circulation above and heating directly onto the damaged surface. No hazardous radiation or damage to piping or cables inside the structure. - EASY TO HANDLE. The STR-600 is very lightweight and easy to carry and handle. To save space during storage and transport, the unit can be used, transported and stored in an upright position. - VERSATILITY: The STR-600 can be used for drying floor structures as well as vertical walls and ceilings. For wall or ceiling use, connector brackets for telescope rods or other support structures are provided. - CONNECTIVITY. Maximum Amp Draw of the STR-600 is 3,0A. It can be connected into any standard, grounded 230 Volt socket. A built-in grounded socket enables chained connection of multiple units with no need for extra extension cords. From a 16-Amp fused socket, 5 dryers can be powered simultaneously. STR-600 is the fastest and safest drying system for local moisture damages in concrete structures

Technical data Size (LxWxH) 1180 x 700 x 170 x mm Frame gasket width 40 mm Weight 12 kg Voltage 230 V, max. 3,0 A / 50 Hz Rated power 0,6 kwh / approx. 10-11 kw per day Automatic timing (heating/ cooling) Yes Automatic timing bypass Yes Extra power socket Yes * Wet air connection Ø 50 mm Air volume: without hose / with hose (4m) 50 m3h / 30 m3h Filter 535 x 78 mm Noise level (3) approx. 44 db ** * Max. 5 devices from a 16-Amp fused socket simultaneously. ** Noise level varies with installation. SALES Strong-Finland Oy Tiilitie 4 01720 Vantaa Finland into@strong.fi www.strong.fi Sales contact: Mr. Tommi Arpomaa Tel. +358 (0)50 350 2980 tommi.arpomaa@strong.fi