Optimizing energy efficiency and occupant comfort with climate specific design of the building

Similar documents
Passive building in Hot and Humid Climates

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

GUIDANCE AND TOOLS FOR CHILLED CEILINGS COMBINED WITH A WET COOLING TOWER

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Recent Advances in Energy, Environment and Economic Development

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

How to ensure Thermal Comfort in buildings with CFD

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

K.F. Fong *, C.K. Lee, T.T. Chow

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Comfort and health-indoor air quality

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

CHAPTER 4. HVAC DELIVERY SYSTEMS

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Systems engineering Slide 1

Liquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements. White Paper

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Museum of Bavarian History Regensburg, Germany

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Desiccant Cooling with Solar Energy

C o o l i n g a n d h e a t i n g s y s t e m s

The Corbioli House is a single-family house situated

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

Adelaide Homes Design Guide 4 - Winter warming

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

ENERGY EFFICIENCY BRIEF REPORT

Technical Assignment 3

Connect North and South Korean Separated Families Higher Comfort Lower Energy

2. CURRICULUM. Sl. No.

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

Design with nature: integrating green façades into sustainable buildings with reference to Abu Dhabi

Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation.

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

7. MECHANICAL SYSTEM DESIGN

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings

A STUDY ON THE APPLICATION OF THE RADIANT FLOOR COOLING SYSTEM INTEGRATED WITH A DEHUMIDIFICATION SYSTEM

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Simplified Space-Heating Distribution using Radiators in Super-Insulated Apartment Buildings

Understanding Ventilation in Hot Humid Climates by Joseph Lstiburek

Solar Heating and Cooling Systems

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

August 15, 2013 Page 1 of 19

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND FOR HEALTHY APARTMENT HOUSING

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

Green Engineering. E-Design 100 Section 020. Group 5: The Lemons Submitted to Professor Smita Bharti (missing picture)

Dynamic performance of a novel dew point air conditioning for the UK buildings

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

nzeb office building

EXPERIMENTAL INVESTIGATION OF THE AIR CLEANING EFFECT OF A DESICCANT DEHUMIDIFIER ON PERCEIVED AIR QUALITY

PRINCIPLES OF HEATING, VENTILATION AND AIR CONDITIONING with Worked Examples

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

INDEX. ADDITIONS AND ALTERATIONS Defined Requirements ADMINISTRATION AND ENFORCEMENT... Chapter 1 AIR ECONOMIZERS

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER

Chilled Beams. Getting a Warmer Reception

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Redesign of Bennett Hall HVAC System

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

ecodry Figure 1 - Process Diagram ecodry B General Process Description

European Researcher, 2014, Vol.(75), 5-2

So far, we have covered the basic concepts of heat transfer and properties.

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

ACHEIVING COMFORT IN SUBTROPICAL CLIMATES: BUILDING A MICROCLIMATE IN THE GUANGZHOU SCIENCE MUSEUM

Impact of indirect evaporative air cooler type on the performance of desiccant systems

WHAT - HOW - WHY - WHERE PROTERCEILING RADIANT CHILLED CEILINGS COMFORT - EFFICIENCY - SAVINGS - AESTHETICS

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Experimental study of space cooling using ceiling panels equipped with capillary mats

The Use Of Attic Space For Cooling and Dehumidification

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Julie Klump, POAH Rick Fenuccio, Tom Hartman Marc Rosenbaum Melpet preliminary heat loss and energy model results and implications

MODELING OF THE SINGLE COIL, TWIN FAN AIR-CONDITIONING SYSTEM IN ENERGYPLUS

Novel Liquid Desiccant Systems

Chapter 10. Passive Cooling Contents

Appendix 13. Categories of Cooling and Heating systems

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1

DESIGN AND SIMULATION OF A SOLAR ASSISTED DESICCANT-BASED AIR HANDLING UNIT

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

A study of radiant cooling for a room with daytime application in tropical climate

Figure 1: Low energy dwellings testsite

Radiant Heating & Cooling for Commercial Buildings

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

Transcription:

Frontiers of Architectural Research (2012) 1, 229 235 Available online at www.sciencedirect.com www.elsevier.com/locate/foar RESEARCH ARTICLE Optimizing energy efficiency and occupant comfort with climate specific design of the building Christoph Mitterer a,n, Hartwig M. Künzel a, Sebastian Herkel b, Andreas Holm c a Fraunhofer-Institut für Bauphysik, Fraunhoferstraße 10, 83626, Germany b Fraunhofer-Institut Solare Energiesysteme, Heidenhofstrasse 2, 79110, Germany c FIW München Forschungsinstitut für Wärmeschutz, Lochhamer Schlag 4, 82166, Germany Received 21 June 2012; accepted 27 June 2012 KEYWORDS Climate specific design; Hybrid cooling; Hygrothermal building simulation; Energy efficiency Abstract Designing energy efficient and comfortable buildings requires harmonizing the complex interactions of architecture, construction and building service engineering. The building envelope has a particular importance, since it integrates many functions and has direct influence on indoor climate. Focusing on satisfaction of the user means that the indoor climate is a key for a holistic design approach. Only a satisfied user will not intervene with the designed energy concept or the indoor climate control; dissatisfaction results in multiple system interventions which may cause waste of energy and sometimes even damage to building envelope components. Satisfaction with the indoor environment also increases working productivity or enables effective recreation of residents. The paper deals with international research activities in the field of climate specific building design. Various comfort and energy monitoring surveys of office buildings as well as residential buildings provide substantial information about the occupants behavior and their needs during specific situations under different outdoor climates. This information allows summarizing basic climate dependent design principles which architects should keep in mind during the early stages of the design process. It also helps to develop strategies aiming at reducing building energy demand and at the same time consider comfort aspects. The second part of this paper demonstrates application of the climate dependent design principles in a housing project in Dubai. & 2012. Higher Education Press Limited Company. Production and hosting by Elsevier B.V. All rights reserved. n Corresponding author. Tel.: +49 8024643644. E-mail address: christoph.mitterer@ibp.fraunhofer.de (C. Mitterer). Peer review under responsibility of Southeast University. 1. Introduction Climate change and rising energy prices have become worldwide issues in the construction industry and force architects and engineers to come up with improved building design concepts. Furthermore, sustainable planning calls for 2095-2635/$ - see front matter & 2012. Higher Education Press Limited Company. Production and hosting by Elsevier B.V. All rights reserved. http://dx.doi.org/10.1016/j.foar.2012.06.002

230 C. Mitterer et al. attention to indoor comfort and damage free construction. Holistic building design is challenging, since climatic boundary conditions have great influence on comfort conditions as well as on the energy efficiency requirements. Focus on creating indoor climate that ensures productive working conditions in office buildings or comfortable conditions in homes is essential. The task of climate specific design is to provide this comfort with a minimum of fossil energy demand while making efficient use of renewable resources. Architects often ignore climate specific design principles. Native architecture is disregarded and western architecture is transferred to different climate zones without adjustments. Additionally, the lack of standards in some countries leads to an indiscriminate transfer of foreign standards. This results in buildings which do not provide adequate comfort. The only way to compensate this deficiency is to use mechanical equipment with high energy consumption. This paper is to highlight the benefits of climate specific design by reviewing the principles and their practical applications. 2. Climate specific building design principles The first step is the optimization of the efficiency of the building envelope. This can be achieved by adequate insulation, air-tightness and optimized glazing, which allows the passive use of solar gains in cold climates or limiting solar impact in hot climates. The second step is the selection of an efficient HVAC system (which may be based on renewable energy sources), but the primary focus is on an efficient operation of the system. A principal rule is shown in Figure 1, where the three steps necessary for an energy efficient building design are depicted. The top priority is reduction of energy losses in cold regions or control of energy gains in hot regions. Only if the building itself is energy efficient advanced technologies using renewable energy sources work efficiently as well. A good energy control fulfills additional requirements. It has to be climate specific, cost effective and user friendly. There is no best technology. The choice of measures depends on climate conditions, micro-climate and available environmental energy, but also on saving potentials and cost-efficiency. The consideration of user s behavior and the user acceptance is essential, since the users have to understand and accept the energy saving measures; otherwise the users interact in a way which is probably not supporting the designed energy control. Whether the targeted savings potentials can be achieved in practice depends not only on the used technology but also on degree to which the design process is integrated and on the quality of craftsmanship. To succeed in designing an optimized building requires understanding of climate specific design principles. This means the overall concept of the construction has to respond to the local environment as well as to the intended use of the building. The main construction features for energy efficient residential or office buildings depend on the outdoor climate and can be summarized as follows: Cold climate: Compact building design with very wellinsulated building envelope components; total fenestration area should be limited with very low U-value and high SHGC (solar heat gain coefficient); mechanical ventilation with heat recovery is essential. Moderate climate: Well-insulated building envelope with energy efficient fenestration (very low to low U-value, moderate to high SHGC depends on glazing area); operable shading systems required to prevent summer overheating; thermal mass and mechanical ventilation with heat recovery is beneficial. Hot and dry climate: Well-insulated building envelope with limited fenestration area; glazing with very low SHGC and shading from direct sunlight in summer; reflective exterior envelope surfaces essential; solar powered AC equipment can provide day-time cooling; thermal mass and lower night-time temperatures provide comfortable indoor conditions after sunset. Warm and humid climate: Moderately insulated building envelope with limited fenestration area having low SHGC and effective shading devices; green (vegetated) roofs and/or reflective exterior envelope surfaces are beneficial; since the removal of latent heat (water vapor) matches the energy required for sensible cooling, investing in sophisticated ventilation and AC systems is essential to provide healthy and comfortable indoor air conditions without wasting energy. These basic climate depending design principles should be kept in mind during the early stages of the design process. Once the construction concept is completed, the specifications of the individual construction components and details as well as the definition of the HVAC equipment have to be completed. This should be done by applying whole building simulation tools (e.g., Energy Plus; UIUC, 2007) rather than referring to standard code requirements and simple load calculations. If humidity-related problems cannot be excluded as for example in warm and humid climates or in high occupation buildings in cold and moderate climates, hygrothermal whole building simulation tools such as WUFI-Plus (Holm et al., 2003) should be employed to check the fitness for purpose of the design. 3. Concepts for a set of net-zero energy houses in the Middle East Figure 1 Principal rules for developing a user friendly and climate specific energy control. The following part describes a project (Zirkelbach et al., 2008) in Dubai, where the principles of climate depending design were applied to develop and evaluate an energy

Optimizing energy efficiency and occupant comfort 231 control for a set of net-zero energy houses. The task of this project was to develop a master plan for in total 32 individual buildings, each of them with a net floor area of more than 300 m 2, located on an island about 8 km off the coast of Dubai. In achieving a comprehensively planned and integrated community with a sense of luxury the project also expects to set new standards in environmental design, getting close to a net-zero energy concept. This means that the building energy demand is balanced over a year by renewable energies for typical Dubai climate conditions. Compared to building regulations in Dubai, climate specific design reduces the solar gains and helps to provide a comfortable indoor climate while also saving a big part of the necessary energy. Climate specific design bases on a detailed analysis of the local climate parameters and a consequent evaluation of the responses of the building to these parameters. A step by step approach to minimize the energy demand allows an easy evaluation and quantification of the single actions and permits a simple cost benefit ratio. Dubai is one of the hottest and most humid cities in the world. Its climate is comparable to that of hot and dry climate zones with the exception of the humidity which is also very high. Therefore not only cooling, also dehumidification is a major issue. The concept is based on two parts, the optimization of the building envelope and the development of an innovative efficient building service system with use of renewable energy; both are optimized with regard to a reduction of building energy demand. The use of passive means of climate control such as building orientation, shading devices, natural ventilation and operable facades should provide the development with a very strong environmental meaning. Significant impact factors for the energy demand of a building are air temperature, relative humidity and intensity of radiation. A further matter of importance may be wind and precipitation, if it is possible to enhance the interior climate by natural ventilation and evaporative cooling. This means that first of all, the in-situ climate conditions and related factors such as exposition, orientation and building operation have to be carefully analyzed. Responding to these boundary conditions, a building and its technical equipment are to be designed that meet the requirements of a zero emission concept for the conditioning of the indoor climate including auxiliary energy demand (electricity for pumps, etc.). Especially the dry and wet bulb temperature of the exterior climate and the global radiation(see Figure 2) are relevant to the dimension of the HVAC systems. In summary, it can be concluded that the temperature level of the outdoor climate does not require any heating during the whole year while air conditioning in summer seems to be inevitable. Concerning the building concepts, attention must be paid to minimize both heat and radiation gains as far as possible. Various construction measures are proposed to minimize the energy demand for cooling. For the first part, thermal building simulations have been preliminarily conducted to analyze the useful energy demand of the buildings for cooling and dehumidification. This is the prevailing building energy demand due to the hot and humid climate conditions at site. It was completed by useful energy demand calculations for hot water and electricity for plugs and appliances. The energy saving potential of the measures was checked and evaluated. The main measures to minimize the cooling load of a building are as follows: low surface volume ratio (favorably large, multi-storey objects); building orientation with main fac- ades preferably in north/south direction (no low angle solar input); possibly small window area, double- and triple-glazing, avoiding windows facing east or west; preferably automatic shading devices as well as low SHGC-values of the windows; high level of insulation, especially on the roof; light-colored exterior surfaces; low air change rates and ventilation system with enthalpy recovery; small alleyways and close building arrangements to provide mutual shading and reduce convective heat loss. The building envelope was initially designed with respect to the local building standard (Degree 66). Afterwards it was improved and optimized in a step by step approach in order Figure 2 ly averages of air and wet bulb temperature, relative humidity and global radiation on a horizontal surface in Dubai.

232 C. Mitterer et al. 20000 15000 solar gains internal loading, convective internal loading, radiant opaque part. windows ventilation Degree 66 Optimal solar gains internal loading, convective internal loading, radiant opaque part. windows ventilation Heat flow [kwh/] 10000 5000 0-5000 Figure 3 ly heat flows for the design according to the local energy code (left) and for the optimal design (right). to arrive at the described energy demand targets. Figure 3 shows the monthly distribution of the heat fluxes for the design according to the local energy code. The heat fluxes of different types of building components are represented by various colors. This allows to figure out the highest potential for improvement. In this case the solar gain through the windows and the heat transmission though the opaque partitions appear to be most important. The relatively large roof area of the detached houses is responsible for the dominating fraction of opaque partitions. Further potential for reducing heat flow through the building envelope can be seen in improved windows. In order to investigate the most cost effective measures a parametric study was carried out, whose results are depicted in Figure 4. Different thicknesses of the insulation layers on the wall and on the roof were tested. For the roof an optimum of 150 mm and for the wall an insulation thickness of 100 mm were found. In the same way the U-value and the SHGC of the windows were evaluated. By optimizing the thermal performance of the envelope, the windows and the ventilation system, significant improvement was achieved (Figure 3). Due to the hot and humid climate at site, energy is required for air cooling and dehumidification throughout the year. Figures 5 and 6 show the monthly dehumidification and sensible cooling rates for the optimized building design. In this case the cooling load is comparable to the dehumidification load (the latter depends mainly on the ventilation rate). This indicates that typically split refrigeration systems cannot be used to cool and dehumidify the room air at the same time. After optimizing the building envelope, the concept comprised the development of an energy efficient building services system which has to provide the useful energy calculated in step 1. A standard system for residential houses in such climates is the use of local split-units with air-circulation that are typically installed in each room; natural ventilation through openings like windows and gaps defines the air change rate. However, due to the small heat capacity of air an index for the potential to store and transport cold or heat high air flow rates would be required to cover the total cooling demand for the building. This potentially leads to draft, high operation energy demands and dissatisfying noise levels from the local compressor and fans; the local units and pipes are visible. Moreover, the required hygienic air change rate cannot be guaranteed by the self-regulating natural ventilation system. According to the problems which arise from a standard system, an efficient and esthetically convincing, lean HVAC concept has been developed. Since only a relative small hygienic air flow rate is required for each villa, dehumidification and sensible cooling has been realized by two separate systems. An air-based system is used to dehumidify the air and a water-based system is used for sensible cooling (since water has a higher heat capacity than air). The net-zero energy houses are equipped with a mechanical ventilation system. Its main task is to ensure a hygienic air change rate and to dehumidify the air. The air handling unit (AHU) contains an enthalpy recovery component. This rotary air-to-air energy exchanger obtains a recovery rate of up to 80%, which significantly reduces the cooling energy demand due to ventilation. An additional component of AHU is the adiabatic cooling at the exhaust side, which further increases its efficiency. This component cools the exhaust air adiabatically by spraying water into it before the exhaust air enters the recuperator (energy exchanger). This component increases the heat recovery efficiency of the recuperator without the need for additional water since

Optimizing energy efficiency and occupant comfort 233 Figure 4 Impact of the different thermal improvements on the annual cooling demand. Cooling Dehumidification 0 20000 humidification dehumidification -5000 15000 Heating/Cooling [kwh/month] 10000 Latent heat [kwh/month] 10000-15000 5000 heating cooling -20000 0 Figure 5 ly sensible cooling and latent cooling (dehumidification) rates. condensed water from the dehumidifying coil of the inlet side is recycled and used by the adiabatic cooling component. The ambient air, which had been cooled below its dew point during the dehumidification process, is naturally reheated by an air-based thermo-activated ceiling (i.e., air tubes within the slab). The air approaches nearly room temperature before it enters the room at the inlets. An energy demanding backup-heater, as it would exist within a conventional HVAC system, is therefore not required. Sensible cooling of the rooms is realized by a water-based thermo-active building system (TABS). Such a system is based on chilled water flowing through a pipe-work within the ceiling and cools the surrounding concrete. The cool surface subsequently cools the room due to convection and radiation. Due to the large area of the ceiling, the surface temperature can be close to that of the room air (i.e., low energy system) and still sufficient cooling can be obtained. Thus, the chilled water temperature can be on a higher level than it would be required for a typical air-conditioning system. This leads to a higher efficiency of cold production. The concept is advantageous from the energy and thermal comfort points of view. As a consequence, a lean building concept has been realized according to the use of the AHU (with features like heat recovery, dehumidification and natural reheating) and the TAB-system. The concept is also esthetically convincing, since the system is mainly invisible for the occupants: the system components are hidden within the building construction and plant room. In order to supply the AHU and the TABS with chilled water, a water cooling system is required. Various technologies have

234 C. Mitterer et al. energy exchanger (recouperator) dehumidifying coil slab-integrated air tubes (re-heating) concret slab slab-integrated water pipes (TABS) ambient air exhaust air AHU recycled condensed water adiabatic cooling component supplyair returnair dehumidifying sensible cooling hybrid cooling Room Figure 6 Scheme of the air handling unit (AHU) and principle of hybrid cooling. Conditioning of the room with two separate systems for cooling (water based system) and for dehumidification (air-based system). Figure 7 Design of the villas and the main energy saving measures (Puertas, 2008). been discussed in terms of their feasibility on site. The final concept makes use of solar-assisted vapor compression chillers. A parametrical study for different operation strategies has been carried out with regard to the energy performance efficiency: the high thermal mass of the thermally activated ceiling concrete is similar to that of a huge heat sink (i.e., cold storage). The room heat gains can be stored during the day and released at night by night-time operation of the TABS. Since the ambient air temperature is lower at night than during day-time, the chillers can release the heat and therefore produce cold water more effectively during nighttime operation. The high chilled water supply temperature level (e.g., 15 1C) ensures a good chiller performance (SPI44). In conclusion, a night-time operation of the chiller is considered to supply the TABS. In contrast, the AHU does not contain any thermal mass and therefore requires a huge cold water storage or 24 h operation. To provide chilled water for dehumidification, its temperature must be below the dew point of the air (e.g., 6 1C) which reduces the chiller performance (SPIE3.7). A 24 h chiller operation mode with supply temperature at 6 1C is thought to be more economical than night-time operation. Basically two design strategies are possible for the building services system: de-central and central systems. In the case of a de-central system, the components are implemented locally in each house, while for a central concept the main components for cold and hot water production and air conditioning are provided in a central plant room. In the latter case cold water, hot water and conditioned air are distributed to the houses by a pipe and duct system. Finally, a semi-centralized concept has been considered: cold water is provided by a central system, but hygienic components such as the AHU are installed decentrally within each house. The architects realized an appealing building design while taking into consideration the findings of the climate specific development and evaluation of an energy efficient building energy concept. The section drawing of the planned house, depicted in Figure 7, shows the layer of insulation, which encloses the core volume of the house with air-conditioning. The deep balconies provide permanent shading to the south facing windows. This allows also that large window areas may be oriented toward east or west, in case the master plan of the island demands for it. The advanced cooling and ventilation concept provides best comfort and is invisible for the occupants. 4. Conclusion A holistic building climate design considers the specific outdoor condition of the climate zone as well as the cultural peculiarities which lead to formulating specific requirements. A sustainable energy control requires focusing on the users, the climate and the cost-effectiveness. A

Optimizing energy efficiency and occupant comfort 235 combined comfort and energy demand monitoring is of value, to gain profound understanding of the reaction of a building to the specific climate as well as of users behavior or user acceptance. It has been demonstrated how houses in an extreme climate can be designed efficiently and how cooling and air-conditioning can be optimized considering the hot temperatures and high humidity. References Holm, A.H., Künzel, H.M., Sedlbauer, K., 2003. In: Proceedings of the hygrothermal behavior of rooms: combining thermal building simulation and hygrothermal envelope calculation. Eighth International IBPSA Conference, Eindhoven, The Netherlands, 11 14 August 2003, pp. 499 505. Puertas, P., A-cero, 2008. The Heart of Europe on The World. /www.a-cero.coms. UIUC, LBNL. 2007. EnergyPlus Input Output Reference, US Department of Energy. Zirkelbach, D., et al., 2008. Feasibility study for energy efficiency and building physics of the urban development project The Heart of Europe in Dubai. IBP-Report, IBP-HTB-15/2008.