2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Similar documents
2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

KNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX

=== Ende der Liste für Textmarke Cover === Detector

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Gira nurse call system Installation, start-up, operation. Gira emergency set

Installation manual plugs and connectors QUICK-CONNECT (63 A)

3-way switching valve

Operator s manual. Battery charger C 48/ en / 03

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

TDS 20 R / TDS 30 R / TDS 50 R

Test Unit GTL 100 for Fire Detectors

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

TTV 4500 / TTV 4500 HP / TTV 7000

SCHMIDT LED Measured Value Display MD Instructions for Use

Busch-Watchdog presence. Overview and applications of presence detectors.

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Operating instructions

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Installation and operation manual

Instruction Manual. Electronic gas and smoke detector GRM

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Operating instructions. Emergency system set. Ref.-No.: NRS Safety instructions. 2. System overview

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

FSW300 Series Flow Switch

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating Instruction

Operating instructions

TDS 100. EN Operating Manual Electrical Fan Heater

USE AND INSTALLATION HANDBOOK

Operating Instructions UniTech Perfect

Flameproof Manual Call Points

MANUAL Oil Level Sensor

Operating Instruction

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

GB Operating instructions

Strip-Cut Shredder S5

Operating Manual. Series FCU5xxx. Sauna Sauna & Humidity Sauna, Humidity & IR Steam Bath FCU5000 FCU5200 FCU5400 FCU5000-STEAM. VDE in preparation

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

L / -014L / -015L

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Electro-hydraulic crimping tools. HD400-6 Art HD300-6 Art convincing solutions

Operating instructions

Operating instructions

CoMo-Control. Operating Manual. English (translation of original instructions) Documentation no.: a

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Alarm Switchgear AS1-M

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

EN Z Subject to change due to technical improvements! Operating instructions

Operating instructions

Original operating instructions Safety switch with guard locking AC901S AC902S

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Operating instructions

Original Operating Instructions V-VTE

STRIP CUT PAPER SHREDDER

Hydraulic crimping tool. HO-16 Art QZERTIFIKAT DIN EN ISO convincing solutions

Stripping machine AI 01

Short Instruction for Use for in-home care ASSKEA procuff M and ASSKEA procuff S

Operating instructions

Instructions For Use ENG. LED Magnifier Lamp

SILENT compact /

Toaster. Model: ST17020/ST17010 (all colours) v1.0. Helpline:

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

3M Benchtop Air Ionizer 963E. User s Guide

Operating Manual. VIENNA Hot Display

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D

For the heating engineer. Installation manual. Interface 0-10V VR34

FP120-Z1 Power supply kit A (70 W) Technical Manual

Thermocouples and Resistance Thermometers

Sip Vacuum Cleaner 1400/35 Wet & Dry

HR 601 C A AUS. ENGLISH Instructions for use Page 2

Supplement to operating and installation manual no for the VR 81 remote control unit

GMA Panels with double busbar

Hydraulic crimping tool. HO-6 Art convincing solutions

Telephone dialing device TWG 01

TTK 70 S OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK70S-TC-001-EN

Rechargeable Trimmer. Rechargeable Trimmer Instructions

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

USM. Haller E. Operating Instructions

INSTRUCTION MANUAL MODEL: 690E

Operating Manual MS220DA

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

CD30 Codoor. Instruction Manual

wan Travel Kettle designed for life For model: SK27010N v3.2 SK27010N.indd 1 12/02/ :12

PERFORMANCE SLIMMING BELT

Optoelectronic level switches, models OLS-C. Optoelektronische Füllstandsschalter, Typen OLS-C. Commutateurs de niveau opto-électroniques, type OLS-C

DOC JAN06 LT 200

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

Operation Manual. Pond Pump Series HJ and CQP

Operating instructions (translation) Stunning Device for Small Animals

Transcription:

2CKA001473B9007 19.05.2017 System Manual Busch-Infoline Handicapped toilet signal set 1510 UC-... -101

Table of contents Table of contents 1 Notes on the instruction manual... 3 2 Safety... 4 2.1 Information and symbols used... 4 2.2 Intended use... 5 2.3 Improper use... 5 2.4 Target group / Qualifications of personnel... 6 2.4.1 Operation... 6 2.4.2 Installation, commissioning and maintenance... 6 2.5 Safety instructions... 7 3 Information on protection of the environment... 8 3.1 Environment... 8 4 Setup and function... 9 4.1 Device overview... 9 4.2 Functions... 10 4.3 Possible combinations... 11 5 Connection, installation / mounting... 12 5.1 Requirements for the electrician... 12 5.2 Mounting... 13 5.3 Electrical connection... 16 5.3.1 Cable cross-section... 17 6 Commissioning... 18 7 Operation... 19 7.1 Triggering a call... 19 7.2 Call display... 19 7.3 Deactivating the call... 20 8 Maintenance... 21 8.1 Cleaning... 21 9 Technical data... 22 10 Index... 23 2

Notes on the instruction manual 1 Notes on the instruction manual Please read through this manual carefully and observe the information it contains. This will assist you in preventing injuries and damage to property, and ensure both reliable operation and a long service life for the device. Please keep this manual in a safe place. If you pass the device on, also pass on this manual along with it. Busch-Jaeger accepts no liability for any failure to observe the instructions in this manual. If you require additional information or have questions about the device, please contact Busch- Jaeger or visit our Internet site at: www.busch-jaeger.com 3

Safety 2 Safety The device has been constructed according to the latest valid regulations governing technology and is operationally reliable. It has been tested and left the factory in a technically safe and reliable state. However, residual hazards remain. Read and adhere to the safety instructions to prevent hazards of this kind. Busch-Jaeger accepts no liability for any failure to observe the safety instructions. 2.1 Information and symbols used The following Instructions point to particular hazards involved in the use of the device or provide practical instructions: Danger Risk of death / serious damage to health The respective warning symbol in connection with the signal word "Danger" indicates an imminently threatening danger which leads to death or serious (irreversible) injuries. Warning Serious damage to health The respective warning symbol in connection with the signal word "Warning" indicates a threatening danger which can lead to death or serious (irreversible) injuries. Caution Damage to health The respective warning symbol in connection with the signal word "Caution" indicates a danger which can lead to minor (reversible) injuries. Attention Damage to property This symbol in connection with the signal word "Attention" indicates a situation which could cause damage to the product itself or to objects in its surroundings. NOTE This symbol in connection with the word "Note" indicates useful tips and recommendations for the efficient handling of the product. This symbol alerts to electric voltage. 4

Safety 2.2 Intended use The call set serves for setting up a call system in WCs for the handicapped according to DIN VDE 0834. The individual device inserts (see chapter 4.1 Device overview on page 9) are used for triggering and deactivating a call and for alerting a person. 2.3 Improper use Each use not listed in Chapter 2.2 Intended use on page 5 is deemed improper use and can lead to personal injury and damage to property. Busch-Jaeger is not liable for damages caused by use deemed contrary to the intended use of the device. The associated risk is borne exclusively by the user/operator. The device is not intended for the following: Unauthorized structural changes Repairs Outdoor use 5

Safety 2.4 Target group / Qualifications of personnel 2.4.1 Operation No special qualifications are needed to operate the device. 2.4.2 Installation, commissioning and maintenance Installation, commissioning and maintenance of the device must only be carried out by trained and properly qualified electrical installers. The electrical installer must have read and understood the manual and follow the instructions provided. The electrical installer must adhere to the valid national regulations in his/her country governing the installation, functional test, repair and maintenance of electrical products. The electrical installer must be familiar with and correctly apply the "five safety rules" (DIN VDE 0105, EN 50110): 1. Disconnect 2. Secure against being re-connected 3. Ensure there is no voltage 4. Connect to earth and short-circuit 5. Cover or barricade adjacent live parts The call system must be installed by specialist staff according to DIN VDE 0834. 6

Safety 2.5 Safety instructions Danger - Electric voltage! Electric voltage! Risk of death and fire due to electric voltage of 100 240 V. Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death. Work on the 100 240 V supply system may only be performed by authorised and qualified electricians. Disconnect the mains power supply before installation / disassembly. Never use the device with damaged connecting cables. Do not open covers firmly bolted to the housing of the device. Use the device only in a technically faultless state. Do not make changes to or perform repairs on the device, on its components or its accessories. Keep the device away from water and wet surroundings. Caution! - Risk of damaging the device due to external factors! Moisture and contamination can damage the device. Protect the device against humidity, dirt and damage during transport, storage and operation. 7

Information on protection of the environment 3 Information on protection of the environment 3.1 Environment Consider the protection of the environment! Used electric and electronic devices must not be disposed of with domestic waste. The device contains valuable raw materials which can be recycled. Therefore, dispose of the device at the appropriate collecting depot. All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies. The products meet the legal requirements, in particular the laws governing electronic and electrical devices and the REACH ordinance. (EU Directive 2012/19/EU WEEE and 2011/65/EU RoHS) (EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006). 8

Setup and function 4 Setup and function 4.1 Device overview Alarm signalling insert Power supply insert Fig. 1: 1515 U-...-101 Fig. 2: 1518 U Signal / cancel push-button insert Fig. 3: 1520/1 UK-101 Note A maximum of 8 alarm push-buttons can be operated jointly in the system. 9

Setup and function Fig. 4: 1520/1 UKZ-101 4.2 Functions A call can be triggered via the signal push-button insert in the room (1520/1 UK-101 / 1520/1 UKZ-101). The call signal is transmitted to the alarm signalling insert (1515 U-...-101). After triggering a call, the alarm signalling insert creates a permanent acoustic and visual signal. The person requiring assistance is additionally signalled via signal push-button integrated in the comforting light that the call has been triggered. The call is ended by pressing the cancel button. A night light has additionally been integrated in the signal/cancel push-button insert 1520/1 UKZ-101. This makes it possible for the person seeking assistance and the helper to locate the button as quickly as possible also in the dark. 10

Setup and function 4.3 Possible combinations 1510 UC-... -101 1511 UC-... -101 X 1539 U X 1563 U-12 X 1561 U-101 X 1564 U-1X X 1566 U X 1520/1 UK-101 X 1520/1 UKZ-101 X 11

Connection, installation / mounting 5 Connection, installation / mounting Danger - Electric voltage! Risk of death due to electrical voltage of 100 240 V during short-circuit in the low-voltage conduit. Low-voltage and 100 240 V conduits must not be installed together in a flush-mounted box! 5.1 Requirements for the electrician Danger - Electric voltage! Install the device only if you have the necessary electrical engineering knowledge and experience. Incorrect installation endangers your life and that of the user of the electrical system. Incorrect installation can cause serious damage to property, e.g. due to fire. The minimum necessary expert knowledge and requirements for the installation are as follows: Apply the "five safety rules" (DIN VDE 0105, EN 50110): 1. Disconnect 2. Secure against being re-connected 3. Ensure there is no voltage 4. Connect to earth and short-circuit 5. Cover or barricade adjacent live parts. Use suitable personal protective clothing. Use only suitable tools and measuring devices. Check the type of supply network (TN system, IT system, TT system) to secure the following power supply conditions (classic connection to ground, protective earthing, necessary additional measures, etc.). 12

Connection, installation / mounting 5.2 Mounting Caution! The device can sustain damage when coming into contact with hard objects! The plastic parts of the device are sensitive. Pull the attachment off only with your hands. Do not lever parts off with screwdrivers or similar hard objects. The flush-mounted insert must only be installed in flush-mounted wall boxes according to DIN 49073-1, Part 1, or suitable surface-mounted housings. Recommended mounting heights Signal/cancel push-button insert: Alarm signalling insert: 0.7-1.5 m height In bathrooms at least 20 cm above the highest possible point of the shower head. The pull cord must also be reachable by a person lying on the floor. 1.5-2.2 m height It is recommended to mount the cancel button insert directly next to the entrance door. If the device is already mounted or assembled, pull the attachment off the flush-mounted insert with the aid of the cover frame. Pull the attachment off only with your hands! Do not lever parts off with screwdrivers or similar hard objects. This will damage the device. When pulling off, first the resistance of the spring clamps must be overcome. Fig. 5: Wall mounting: pulling off the attachment - Example 1515 U-...-101 13

N Connection, installation / mounting Use the following steps to mount the device: 1. Connect the cables to the flushmounted insert. For the connection assignment, see chapter 5.3 Electrical connection on page 16. Fig. 6: Connecting the cables 2. Bundle the wires of the mains cable (230 V) with the cable binders included in the scope of supply [b]. 3. Feed the low-voltage line through the supplied insulating tube [a]. a 150mA 15V~ 100m A 230V~ b Fig. 7: Fixing the cables 14

Connection, installation / mounting 4. Mount the flush-mounted insert in a flush-mounted box according to DIN 49073-1. 5. Fix the device in the flush-mounted box with screws. Fig. 8: Mounting the flush-mounted insert Fig. 9: Mounting the attachment 6. Plug the attachment together with the cover frame onto the flush-mounted insert. Ensure that the plug-in connection on the rear side does not get jammed. If mounting is difficult, check whether a burr has formed at the lock-in openings of the flushmounted insert and remove it. The device is now mounted. 15

Connection, installation / mounting 5.3 Electrical connection Note The lines of the call system must not be installed in a multi-wire cable together with conductors which carry mains voltage. The lines of the call system must not be installed in an installation tube together with conductors which carry mains voltage. The lines of the call system may only be installed at a minimum distance of 30 cm to lines which carry mains voltage. In case of connections with a line length of < 10 meters, a minimum distance of 10 cm is sufficient. All standards applicable to security technology for the installation of electrical systems, as well as guidelines for wiring call systems in medical care facilities according to DIN EN 793 must be adhered to. All interfaces to other call systems conform to standard EN 60950-1. A maximum of 8 alarm push-buttons can be operated jointly in the system. Attention! - Failure of the call set at a power failure Use an uninterruptible power supply (UPS) to guarantee the function of the call set in case of a power failure. Consider the following points when installing the line: Fireproof installation in escape routes Safe electrical insulation against systems with high voltage Prevention of faults caused by other systems Reliable wire connection 16

Connection, installation / mounting 5.3.1 Cable cross-section Note The minimum cable cross-section is 0.6 mm. The power supply is still ensured in case of cable cross sections smaller than 0.6 mm. Nominal current for different cable cross-sections Cable cross-section in mm 2 Nominal current in A 1 6 7.2 1.5 10 12 2.5 16 19.2 Table 1: Nominal current for different cable cross-sections Sustained short-circuit current 16 A 1 230 V ~ L N 2 3 4 3 2 14 1 kohm 1 R RESET 11 12 1 2 3 4 1 2 3 4 7 6 5 4 Fig. 10: Circuit diagram [1] Separate device installation box [2] Protective insulation [3] Power supply insert [4] Alarm signalling insert [5] Cancel button insert [6] Signal push-button insert with pull cord [7] Terminal resistor 17

Commissioning 6 Commissioning Check the functions of all devices as follows: 1. Measure the operating voltage (see chapter 9 Technical data on page 22). 2. Press the signal push-button. / Pull at the pull cord of the signal push-button insert. 3. Check whether the comforting light is on in the signal push-button insert and the alarm signalling insert sends an acoustic and visual signal. 4. Press the cancel button to deactivate the call. 18

Operation 7 Operation 7.1 Triggering a call There are two ways to trigger a call: Press the signal push-button in the 1520/1 UK-101. Fig. 11: 1520/1 UK-101 Pull at the pull cord or press the signal push-button of the 1520/1 UKZ-101. Fig. 12: 1520/1 UKZ-101 The comforting light in the signal push-button insert signals to the person requiring assistance that the call has been triggered. 7.2 Call display As soon as a call has been triggered, the alarm signalling insert creates an acoustic and visual signal to alert a helper. 19

Der Ruf Operation 7.3 Deactivating the call The call is deactivated by pressing the cancel button. Fig. 13: 1520/1 UK-101 Note If a call has already been deactivated but assistance is still required, the call button must be pressed again. 20

Maintenance 8 Maintenance 8.1 Cleaning Caution! - Risk of damaging the device! When spraying on cleaning agents, these can enter the device through crevices. Do not spray cleaning agents directly onto the device. Aggressive cleaning agents can damage the surface of the device. Never use caustic agents, abrasive agents or solvents. Clean dirty devices with a soft dry cloth. If this is insufficient, the cloth can be moistened slightly with a soap solution. 21

Technical data 9 Technical data Designation Nominal voltage: Nominal current: Output voltage: Power loss: Loop current: Tripping delay: Sound frequency: Sound pressure level: Temperature range: Storage temperature: Value 230 V AC, ±10%, 50 Hz 110 ma AC / 60 ma DC 15 V AC (SELV) 2000 mw 5 ma 0.1 s 2300 Hz 70 db / 1 m 0 C to +35 C -10 C to +60 C Protection type: IP 20 Minimum cable cross-section 0.6 mm [1] Interfaces to other call systems According to EN 60950-1 Switching contacts Normally open contact (potential-bound): Change-over contact (floating) 1 A, 30 VA / W 40 V AC / 60 V DC, 30 VA / W Table 2: Technical data [1] The power supply is still ensured in case of cable cross sections smaller than 0.6 mm. 22

Index 10 Index C Cable cross-section... 17 Call display... 19 Cleaning... 21 Commissioning... 18 Connection, installation / mounting... 12 D Device overview... 5, 9 E Electrical connection... 14, 16 Environment... 8 F Functions... 10 I Improper use... 5 Information and symbols used... 4 Information on protection of the environment... 8 Intended use... 5 M Maintenance... 21 Mounting... 13 N Notes on the instruction manual...3 O Operation...6, 19 P Possible combinations...11 Q Qualification of personnel...6 R Requirements for the electrician...12 S Safety...4 Safety instructions...7 Setup and function...9 T Target group...6 Technical data...18, 22 Triggering a call...19 23

A member of the ABB Group Busch-Jaeger Elektro GmbH PO box 58505 Lüdenscheid Freisenbergstraße 2 58513 Lüdenscheid www.busch-jaeger.de info.bje@de.abb.com Central sales service: Tel.: +49 2351 956-1600 Fax: +49 2351 956-1700 Notice We reserve the right to make technical changes at all times as well as changes to the contents of this document without prior notice. The detailed specifications agreed upon apply for orders. ABB accepts no responsibility for possible errors or incompleteness in this document. We reserve all rights to this document and the topics and illustrations contained therein. The document and its contents, or extracts thereof, must not be reproduced, transmitted or reused by third parties without prior written consent by ABB Copyright 2017 Busch-Jaeger Elektro GmbH All rights reserved