Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Similar documents
Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Autocalibration Systems for In Situ Oxygen Analyzers

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

High Pressure Conductivity Monitor

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

OMA-300 Process Analyzer

APPLIED. OMA-406R Rackmount Process Analyzer

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Net Safety ST3 XChem Toxic Gas Sensor

Rosemount 3051S Electronic Remote Sensors

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Advanced Diagnostics for HART Protocol Rosemount 3051S Scalable Pressure, Flow, and Level Solutions

Rosemount 3490 Series

Industrial Grade Gas Detection

HFID Heated Total Hydrocarbon Analyzer Module

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Duct Mount. Installation Instructions

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

Industrial Grade Gas Detection Detecting The Difference

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

CERTIFICATE of Product Conformity (QAL1)

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 2100 Series

Rosemount High Density Temperature Measurement. Simplify Your Project

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Magnetically Operated Touch Panel Hints on Operating CAT 100 / BINOS 100 F and CAT 200 / MLT 2 Gas Analyzers

Dual Input ph/conductivity Analyzer

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Industrial Grade Gas Detection

Rosemount 1500XA Process Gas Chromatograph

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

Rosemount 2090P Pulp and Paper Pressure Transmitter

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Dependable Solutions for Gas Detection

Quick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors

Model D12-IR. Digital Gas Transmitter...

Semi flush-mount room thermostats

Spectron LSN (Life Safety Network) Suggested Specifications

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Controllers, Indicators & Set Point Programmers

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

PURSense Sanitary Flange Conductivity Sensors

Low Temperature Zirconia Oxygen Analyzer

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Rosemount Functional Safety Manual. Manual Supplement , Rev AF March 2015

Rosemount 1500XA Process Gas Chromatograph

Zircomat Oxygen Analyzers

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Rosemount 3051S MultiVariable Transmitter

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dual Input ph/orp Analyzer

Quick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor

Dual Input Toroidal Analyzer

A New Standard of Excellence

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Process Gas Chromatograph

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

CLARITY II TURBIDIMETER

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger QuadGard Control System

Model 4001 Series Single Channel Controller

Dräger PointGard 2100 Detection of toxic gases and vapours

Certificate of Compliance

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8700 IR Detection of flammable gases and vapors

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

Rosemount 3100 Series Ultrasonic Level Transmitters

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

245 Sanitary Flow-Through Toroidal Conductivity Sensor. Instruction Manual LIQ_MAN_245 Rev. D January 2014

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Process Gas Chromatograph

I/A Series 716C 1/16 DIN Temperature Controller

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

Dräger Polytron 5720 IR Toxic Gas Detection

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Toxic Gas Detection. Model F12. Toxic Gas Detection

MEAS CAL ALARM WASH CONF APT4000 TC

Model 144H. Product Data Sheet , Rev DB February Content

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Rosemount 752 Fieldbus Remote Indicator

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Rosemount 4500 Hygienic Pressure Transmitter. Start

LORAIN CSP DC Power System

Dräger Polytron 8720 IR Detection of carbon dioxide

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Transcription:

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes Excellent accuracy Large backlit display and keypad NEMA 4X enclosure Works with Westinghouse/Rosemount, and most competitive ZrO 2 probes HART communications standard (AMS aware) Wireless - via THUM TM Adaptor Advanced Features Calibration recommended diagnostic Xi enhanced interface Automatic calibration capability Extended process temperature ranges Stoichiometer feature Programmable reference Wireless THUM TM Adaptor Loss-of-flame heater cut-out Rosemount Analytical Xi Advanced Electronics for Zirconium Oxide Oxygen Probes The zirconium oxide sensing technology for measuring the excess oxygen in combustion flue gases has gained prominence over the past several decades. This versatile electronics is specifically designed to run most O 2 probes manufactured. The large backlit LCD display makes it easy to set up and operate. Fully automatic calibrations may be executed from this electronics with the addition of a small solenoid box for switching calibration gases.

The Xi electronics offers the following unique advanced features never before offered for O 2 probes: Automatic Calibration Plant personnel often ask how frequently an oxygen analyzer requires calibration. The answer is very application-dependent based upon the fuels being burned, normal levels of oxygen and the sulfur content in the flue gases. The Xi addresses this concern by providing an on-line diagnostic that determines when a calibration should be conducted, eliminating many unneeded calibrations and the technician and gas resources they consume. The Xi electronics has an on-line impedance measurement for the sensing cell. This feature can trigger a fully automatic calibration by sequencing solenoids to introduce calibration gases to the sensing cell. The Single Probe Sequencer (SPS) switches CAL gases to a single probe, while a Multi-Probe Sequencer (IMPS) can handle 1 to 4 probes. Many needless calibrations based on time in service are eliminated. A contact closure notifies the control room when a calibration is taking place. The oxygen output signal can be held at its last value, or released during calibration. The Xi can also initiate calibrations by traditional methods: Stoichiometer Process upsets can sometimes cause a combustion process to go into substoichiometric or reducing conditions. The oxygen readings from one or more probes may decline all the way to zero. The stoichiometer cell will measure the amount of oxygen deficiency during these reducing conditions. The trends in your DCS can be set up for a lower range limit of -1 or -2% oxygen to depict the level of oxygen deficiency. The operator can see if his control actions to recover are having the desired effect. These types of events do not occur frequently, but knowing the parameters of the situation prevents overcorrecting while coming out of the reducing condition. Programmable Reference enhances operation for the following applications: Moisture Monitoring measuring the amount of moisture coming off of industrial dryers by noting the dilution effect water vapor has on the normal 20.95% ambient drying air. Enriched Oxygen Combustion Pure oxygen is sometimes mixed in with the combustion air to increase heat at the flame. This is used in steel and other metals reduction processes and also in some catalyst regenerators. Flame Safety Interlock dry contact from a flame safety system removes power from the probe heater in a loss-of-flame event. Contact closure from the user s control room Time since last calibration feature established by the autocalibration system Xi enhanced interface HART/AMS Extended Process Temperature Range Traditional O 2 electronics will go into alarm if the process temperature exceeds the controlled heater temperature. This feature enables the Xi to turn off the internal heater in this event, use the process temperature to heat the cell, and calculate O 2 on the fly from the changing process temperatures. Note that accelerated probe and cell damage may occur as a result of extended operation above 800 C (1462 F), but at least the measurement will not go off-line during this event. 2 www.emersonprocess.com

Specifications General Purpose Certifications Xi Ambient Temp.Limits -20 to 55 C (-4 to 131 F) Xi Temp. Limits as measured inside the housing -20 to 55 C (-4 to 113 F) Xi LCD display Temp. Limits -20 to 55 C (-4 to 131 F) Installation Specifications Electrical Power of Oxymitter or optional Xi electronics 120 to 240V, ±10% 50/60 Hz Power Consumption of Xi 10 watts maximum Xi Alarms Relays 2 provided - 2 amps, 30 VDC Xi Optional Loss of Flame Contact Removes heater power Electrical Noise Meets EN 61326, Class A Power 100-240V ±10%, 50-60Hz Power Consumption of Xi 12VA maximum or 776VA maximum with Traditional Architecture, 120V, Probes. 450VA maximum with Traditional Architecture, 44V Probes Alarm Relay Outputs Two provided - 2 Amperes, 30 VDO, Form-C Optional Loss of Flame Input internally power input to remove heater power, actuated via dry contact output from proof-of-flame device Emerson Process Management has satisfied all obligations coming from the European legislation to harmonize the product requirements in Europe. 1 All static performance characteristics are with operating variables constant. Specifications subject to change without notice. www.emersonprocess.com 3

Dimensions Xi Enhanced Interface - Panel Mounting Details 4 www.emersonprocess.com

Dimensions Xi Enhanced Interface - Wall/Surface and Pipe Mounting Details www.emersonprocess.com 5

Ordering information Xi Advanced Electronics Model Xi Type Product Description O 2 Advanced Electronics 01 Single Channel 02 Single Channel with Flame Safety Interlock for Heater 03 Dual Channel 04 Single Channel, Traditional Architecture for 120V Probes 05 Single Channel, Traditional Architecture for 44V Probes Mounting 01 Panel Mount Kit with Gasket 02 2 Pipe/Wall Mount Kit Cable 10 20 (6m) Cable 11 40 (12m) Cable 12 60 (18m) Cable 13 80 (24m) Cable 14 100 (30m) Cable 15 150 (45m) Cable 16 200 (60m) Cable Stoichiometer Function 1 01 Single Channel 02 Dual Channel (second channel not available for traditional architecture Xi) Programmable Reference Function 1 01 Single Channel 02 Dual Channel, (second channel not available for traditional architecture Xi) Extended Process Temperature (825 )/Heaterless Operation 01 Single Channel 02 Dual Channel, (second channel not available for traditional architecture Xi) Notes: 1 Software feaures may be added in the field after shipment. Wireless THUM TM Adaptor is ordered separately. 6 www.emersonprocess.com

Notes www.emersonprocess.com 7

http://www.emersonprocess.com http://www.analyticexpert.com Rosemount Analytical Headquarters & Liquid Analytical 2400 Barranca Parkway Irvine, CA 92606 United States Phone: 1.800.854.8257 Fax: 1.949.474.7250 http://twitter.com/raihome.com Scan this QR code to open the 106-340.Xi product information Web page. Rosemount Analytical Gas Chromatographs & Service Center 10241 West Little York, Suite 200 Houston, Texas 77040 United States Phone: 1.866.422.3683 Fax: 1.713.827.3865 Rosemount Analytical Process Gas & Combustion Center 6565-P Davis Industrial Pkwy Solon, OH 44139 United States Phone: 1.800.433.6076 Fax: 1.440.914.1262 Rosemount Analytical Latin America Emerson Process Management Analytical Division 111000 Brittmoore Park Drive Houston, TX 77041 Phone: 1.713.467.6000 Fax 1.713.827.3329 Rosemount Analytical - Europe Emerson Process Management Services Ltd. Analytical Division Blegistrasse 21 PO Box 1046 CH 6341 Baar Switzerland Phone: 41.41.768.6111 Fax: 41.41.761.8740 Emerson Process Management Distribution Limited P.O. Box 105958 Abu Dhabi UAE Phone: +971 2 6972072 Fax: +971 2 5550364 Rosemount Analytical Asia Pacific Emerson Process Management Analytical Division Asia Pacific Private Ltd. 1 Pandan Crescent Singapore 128461 Republic of Singapore Phone: 65.6.777.8211 Fax: 65.6.777.0947 2012 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand name is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.