Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Similar documents
Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Department of MCE, Islamic University of Technology 2. Abstract

ADVANCES in NATURAL and APPLIED SCIENCES

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Chapter 10. Refrigeration and Heat Pump Systems

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

DEEPAK PALIWAL, S.P.S.RAJPUT

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Performance of an Improved Household Refrigerator/Freezer

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Chapter 9. Refrigeration and Liquefaction

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

A Comparison Between Refrigerants Used In Air Conditioning

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

Experimental Investigation on R 290 and R 600a In a Vapor Compression Refrigeration

ENERGY, EXERGY AND SUSTAINABILITY ANALYSIS OF TWO-STAGE VAPOUR COMPRESSION REFRIGERATION SYSTEM

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Design of LPG Refrigeration System

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

*Corresponding author;

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Thermodynamics II Chapter 5 Refrigeration

ISSN Vol.08,Issue.21, November-2016, Pages:

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Performance investigation of Air-conditioning system using ejector as expansion device

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

η second law = Second law efficiency

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Performance Study of Geotropic Blends of Isobutane R600a and Propane R290 in Domestic Refrigerator as Alternative Refrigerants to R134a

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Enhancement of COP in Vapour Compression Refrigeration System

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

International Journal of Informative & Futuristic Research ISSN (Online):

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Oyelami S., Bolaji B. O.

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

(Refer Slide Time: 00:00:40 min)

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

ADVANCES in NATURAL and APPLIED SCIENCES

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Compendium DES July 2016, CARN

Study of R161 Refrigerant for Residential Airconditioning

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Thermodynamics I. Refrigeration and Heat Pump Cycles

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Comparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Transcription:

Simulation Analysis of Compression Refrigeration Cycle with Different Refrigerants P.Thangavel, Dr.P.Somasundaram, T.Sivakumar, C.Selva Kumar, G.Vetriselvan Abstract --- In this analysis, the performance of compression cycle is assessed theoretically with different refrigerants. In compression refrigeration system, hydrocarbon refrigerants such as R290 and R600a are considered as a refrigerant by mixing of these at different mass fractions about 20%+80%, 25%+75%, 50%+50% and 75%+25% respectively. Various performance measures like compressor discharge temperature, pressure ratio, volumetric cooling capacity (VCC), volumetric efficiency and mass flow rate are analyzed. The results are compared with halogenated refrigerants such as R134a, R12 for different condenser and evaporator temperatures. Halogenated compounds are having direct environmental impacts in turns of ODP and GWP. Among the hydrocarbon refrigerants group, the mixture of R290 and R600a at concentration of 50% each has optimum performance in terms of higher refrigeration effect, better heat transfer and COP. Key Words: compression system, R290 and R600a, COP Nomenclature T Temperature ( C) P Pressure (bar) M Mass flow rate (kg/s) H Enthalpy (kj/kg) S Entropy (kj/kg) C p Specific heat at constant pressure (kj/kg K) C Clearance ratio N Speed (rpm) N Polytrophic index Η Efficiency (%) Q Heat flow rate (kw) V Specific volume (m 3 /kg) P r Pressure ratio VCC Volumetric cooling capacity (kj/m 3 ) PI Power input (kw) Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid I. INTRODUCTION In nature, heat transfer occurs from the region of higher temperature to lower temperature without requiring any external devices. The reverse process cannot occur by itself. The transfer of heat from lower temperature to higher temperature requires special devices called refrigerators. Refrigerator works under the principle of reversed Carnot cycle. Many types of refrigerants are available for getting cooling effect. It is very much important to use a suitable refrigerant, which gives the maximum cooling effect by consuming minimum power. In present situation, most of the domestic vapour compression refrigerators are equipped with R134a due to its thermodynamic properties. However, it is known that it have a higher global warming potential. So it is important to find alternative refrigerant to R134a. Here R134a is compared with R290 and R600a of different mass fraction. Mohanraj et al. [1] have done an experimental investigation with hydrocarbon refrigerant mixture (composed of R290 and R600a in the ratio of 45.2:54.8 by weight) as an alternative to R134a in a domestic refrigerator. They performed a continuous running test under different ambient temperatures (24, 28, 32, 38 and 43 C), and cycling test (ON/OFF) were carried out at 32 C ambient temperature. The results show that the hydrocarbon mixture has lower values of energy consumption; pull down time and ON time ratio by about 11.1%, 11.6% and 13.2%, respectively, with 3.25 3.6% higher Coefficient of performance (COP). Maclaine-Cross [2] shows that the usage of hydrocarbon refrigerants in the refrigeration systems instead of halogenated refrigerants (such as R134a and R12) reduces energy consumption by 20%. Fatouh et al. [3] conducted an experiment in domestic refrigerators with hydrocarbon refrigerants such as propane and isobutene and shows that the performance of hydrocarbon refrigerants matches with that of R134a. Baskaran et al. [4] performed an analysis on a vapour compression refrigeration system with various refrigerant mixtures of R152a, R170, R600a and R290 at various mass fractions. From their results, the alternative refrigerants except R431a (which is a combination of R152a, R290 at 29% and 71% respectively) have a slightly higher performance than R134a at the condensation temperature at 50 C and evaporator temperature ranging between -30 C and 10 C. Dongsoo Jung et al. [5] examined the performance of a propane/isobutane (R290/R600a) mixture for domestic refrigerators. This thermodynamic cycle analysis signified that the propane/isobutene mixture in the composition range of 0.2 to 0.6 mass fraction of propane 127

yields an increase in the coefficient of performance (COP) of up to 2.3% as compared to R12. The experimental results obtained indicated that the propane/isobutane mixture at 0.6 mass fraction of propane has 3±4% higher energy efficiency and faster cooling rate than R12. The above literature reviews show that the performance analysis on vapour compression refrigeration system with the various possible alternatives. However the possibility of using propane and isobutane in different combinations as alternative to halogenated refrigerants needs further investigation. The present work is aimed to study the possible refrigerant combinations in vapour compression refrigeration system by calculating the performance characteristics such as COP, volumetric cooling capacity, amount of heat rejected in condenser, compressor input power of compression system. II. CYCLE DESCRIPTION A. Vapour Compression Refrigeration System Vapour compression refrigeration system is the most commonly used among all refrigeration systems. In this system, the working fluid is mentioned in the state of liquid and vapour. It must readily evaporate and condense or change alternately between the vapour and liquid phase without leaving the system. Figure 1 illustrates the main components of the vapour compression refrigeration system namely compressor, condenser, expansion device, and evaporator. atmospheric temperature. In some cases flash chamber is used after the expansion device which separates the vapour refrigerant from the liquid and sends it to compressor inlet. III. ANALYSIS OF THE CYCLE The thermodynamic analysis of the compression cycle was performed using the following assumptions. (a) The system is in steady state; (b) The vapour is saturated at the inlet of the compressor; (c) The isentropic efficiency of the compressor is 75%; (d) There is no pressure loss along the pipe and in the valves; (e) Speed of the compressor is 2640 rpm; (f) The condenser (T 3 ) and evaporator (T 4 ) temperatures are assumed to suitable temperatures. The important parameters considered for the analysis of the system are compressor discharge temperature, mass flow rate, pressure ratio, volumetric cooling capacity (VCC) and volumetric efficiency. Table1 shows the mass and energy balance of the compression refrigeration system and based on that, the following equations are considered the analysis of the compression refrigeration system. Table 1. Mass Balance and Energy balance of Vapour Compression Refrigeration System Component Mass balance Energy balance Compressor Condenser Expansion device Evaporator The temperature (T 2 ) at the exit of the compressor can be found by Fig 1. Vapour Compression Refrigeration System The refrigerant vapour at low temperature and low pressure enters the compressor (state 1) where it is compressed isentropically to high temperature and high pressure. The high temperature refrigerant vapour then enters the condenser (state 2) where it is condensed to high pressure liquid. The high pressure liquid refrigerant then enters into expansion device (state 3) where its pressure is decreased. Ultimately the liquid refrigerant will attain lower temperature. This low temperature liquid refrigerant absorbs the latent heat from the evaporator (state 4) undergoes phase change to vapour state. This high temperature vapour refrigerant then sucked by the compressor and the cycle continues which keeps the temperature in the evaporator much below the (1) The enthalpy at the inlet of the compressor is given by (2) The enthalpy at the exit of the compressor is given by (3) The enthalpy at the exit of the condenser is given by (4) The volumetric efficiency of the compressor can be found by (5) 128

The pressure ratio is given by (6) ISSN: 2277-3754 The mass flow rate of the refrigerant is given by mass flow rate of (R290+R600a) mixture is less as comparing to the conventional refrigerants like R12 and R134a. This mixture is having better performance and the mass flow rate is about 0.0638 kg/s. Table 3. Properties of R290 and R600a at different points State T (K) P (bar) h (kj/kg) m ref R290/R600a (kg/s) (7) The VCC is calculated by using (8) The amount of heat rejected in the condenser is given by 1 272.5 3.25 555 0.0638 2 315.31 8.68 621.31 0.0638 3 313 8.68 302.1 0.0638 4 263 3.25 302.1 0.0638 (9) The amount of heat absorbed in the evaporator is given by (10) The power given to the compressor is given by (11) The COP is defined as the ratio between the amount of heat absorbed in the evaporator to the power given to the compressor. It can be expressed as IV. RESULTS AND DISCUSSION The thermodynamic properties of the system at various points shown in Figure 1 are calculated for different refrigerants by using the equations from (1) to (12) and shown in Table 1. The results given in Table 2 are analyzed at T 3 =263 K & at T 4 =313 K evaporator and condenser temperatures respectively. As seen from the Table 2, R290/R600a (50%+50%) has optimum COP compared as compared to other refrigerants considering all factors. R134a and R12 are halogenated compounds which have high environmental impacts. Eventhough they have more COP value, they will pollute the nature. Even though 25%+75% and 20%+80% concentration have high COP, they are not opted because in this case there is increase in entropy of the refrigerant from the beginning which should not occur in ordinary cases. So using these two concentrations are practically not possible. Therefore R290/R600a (50%+50%) concentration might be the suitable one.the properties of R290/R600a (50%+50%) at various points of the compression system are listed in the Table 3. The analysis has been done by taking different condenser and evaporator temperatures and the results are represented in the following figures. As seen from the Figure 2, when the condenser temperature increases, the mass flow rate of the compression system remains almost constant. The Fig 2. Mass flow rate Vs Condenser Temperature at constant evaporator temperature (T 3 =263K) The variation in COP with the condenser temperature is shown in Figure 3. It is observed that when the condenser temperature increases, the COP of the compression system reduces by considerable amount. For this analysis the evaporator temperature is assumed as a constant temperature. The refrigerant R290/R600a at (75%+25%) has low value of COP. Among the investigated refrigerants R290/R600a of (50%+50%) has the better performance and having the COP about 3.81. R12 and R134a are having highest COP values in this group of refrigerants and these hydrocarbon mixtures also having the COP close to the conventional refrigerants. Fig 3. COP Vs Condenser Temperature at constant evaporator temperature (T 3 = 263 K) 129

Figure 4 represents the VCC of the investigated refrigerants with the other refrigerants. This shows that when the condenser temperature increases, the volumetric cooling capacity of the compression system is reduced. Even though R134a and R12 are having highest value of VCC, they will harmful to the environment. The mixture R290/R600a at (50%+50%) having the optimum cooling capacity of 993.63 kj/m 3. Fig 6. Volumetric cooling Capacity Vs Evaporator Temperature at constant Condenser temperature (T 3 = 313 K). Fig 4. Volumetric Cooling Capacity Vs Condenser temperature at constant evaporator temperature (T 3 = 263 K) The variation of COP with the evaporator temperature is shown in Figure 5. Whenever evaporator temperature increases, the COP value is also increases for all the refrigerants. For this analysis the condenser temperature is assumed as a constant temperature. Among the investigated hydrocarbon refrigerants, R290/R600a at (50%+50%) has the better COP value. Fig 5. COP Vs Evaporator Temperature at constant Condenser temperature (T 3 = 313 K) From the Figure 6, it is observed that, when the evaporator temperature increases, the volumetric cooling capacity of the compression system is also increased. The mixture R290/R600a at (50%+50%) has VCC closer to R134a for the wide range of evaporator temperatures. The various performance parameters of vapor compression refrigeration system are analysis and compared with the other refrigerants. From these results, it is clear that the refrigerant mixture of propane and isobutene with mass fraction of 50% each having the better performance among the investigated refrigerants. V. CONCLUSION A simulation analysis was performed theoretically for different refrigerant mixtures for vapour compression refrigeration system and from the analysis it is concluded that, R134a and R12 are halogenated compounds which will cause harmful effects to the environment in terms of global warming and ozone layer depletion. So the attention is focused on alternative refrigerants for vapour compression refrigeration system with hydrocarbon refrigerants. R290 and R600a offer many desirable characteristics such as low operating pressure, mass flow rate and discharge temperature. The COP of these mixtures is close to the conventional refrigerants. Hence propane and isobutene with the concentration of 50% each is the suitable refrigerant among all the investigated refrigerants for vapour compression system. This mixture provides better performance in terms of pressure ratio, volumetric efficiency, heat rejection and COP for the compression refrigeration system. Hydrocarbon refrigerants are having less impact on the environment in terms of global warming. In domestic refrigerators and industrial refrigeration systems, the mixture of R290 & R600a can be used as alternate refrigerant instead of R12 and R134a. REFERENCES [1] Mohanraj.M, Jayaraj.S, Muraleedharan.C and Chandrasekar.P (2009) Experimental investigation of R290/R600a mixture as an alternative to R134a in a domestic refrigerator, International Journal of Thermal Sciences Vol.48, pp.1036 1042. [2] Maclaine-Cross.I.L (1997), Why hydrocarbons save energy, AIRAH Journal, June 1997, Vol.51, pp.33-37. [3] Fatouh.M and El Kafafy.M (2006), Assessment of propane/commercial isobutene mixtures as possible alternatives to R134a in domestic refrigerators, Energy conversion and management, Vol.47, pp.2644-2658. 130

[4] Baskaran.A and Koshy Mathews.P (2012) A Performance comparison of vapour compression refrigeration system using various alternative refrigerants, International Journal of Scientific and Engineering Research, Vol.3 No.10, pp.1-7. [5] Dongsoo Jung, Chong-Bo Kim, Kilhong Song, Byoungjin Park (2000) Testing of propane/isobutene mixture in domestic Refrigerators, International Journal of Refrigeration Vol.23 pp.517-527. AUTHOR BIOGRAPHY P.Thangavel a is working as Assistant Professor (Selection Grade) in Department of Mechanical and Erode, India. He completed his Bachelor Degree in Mechanical Engineering from Bharthiyar University and Master Degree in Energy Engineering from NIT Trichy. He has executed various projects in the field of refrigeration, computational fluid dynamics and heat exchangers. He is life member in Indian Society for Technical Education (ISTE). Dr.P.Somasundaram b is working as Professor in Department of Mechanical Engineering, KSR College of Technology, Tiruchengode, Namakkal, India. He had his Bachelor and Master degree in Mechanical Engineering. He had completed Ph.D. degree from Anna University, Chennai and he has 13 years of teaching experience & 2 years of industrial experience. He is guiding 6 research scholars and his area of expertise is low temperature applications. He has executed various projects in the fields of refrigeration and solar energy. T.Sivakumar c is final year student of Mechanical Erode, India. He is a member of Society of Automotive Engineers. C.Selva kumar d is final year student of Mechanical Engineering, Kongu Engineering College, Perundurai, and Erode, India. He is a member of ISTE student chapter. G.Vetriselvan e is final year student of Mechanical and Erode, India. He is a member of Society of Automotive Engineers. 131