Commercial Products Matrix. SUBJECT TO CHANGE WITHOUT NOTI CE TYPE OF SALE: 6JSS SHIPPING POINT: Lewisburg, TN

Similar documents
Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

50TM COMBINATION HEATING/COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

50TM TFF COMBINATION HEATING/COOLING UNITS

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

90.1 COMPLIANT PACKAGED ROOFTOP HEAT PUMP UNITS, R 410A, TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

48TF GAS HEATING/ ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

RHX. Product Specifications

Product Data WeatherMaker Single Package Rooftop Heat Pump Units

48PGD/E/F/L/M/N PG20-28

ENERGY STAR COMPLIANT 13 SEER SINGLE PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A ROOFTOP 3 5 TONS 575V BUILT TO LAST, EASY TO INSTALL AND SERVICE

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Input Cap. (Btuh) Stage 2

50KCQ Packaged Heat Pump 14 SEER 3to5NominalTons. Product Data C08613

Product Data RELIABILITY FEATURES

Input Cap. (Btuh) Stage 2

ENERGY STAR COMPLIANT PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

50TC Single Package Rooftop Cooling Only Vertical Air Flow Unit with Puron

PAR5. Product Specifications

Product Data KUWAIT SERIES

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50HJ Single-Package Rooftop High-Efficiency Electric Cooling Units. 3 to 12 1 / 2 Nominal Tons

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

50TC Single Package Rooftop Cooling Only Horizontal Air Flow Unit with Puronr (R---410A) Refrigerant 15, 17.5, 20, 25 Tons --- (Sizes 18, 21, 25, 29)

Product Data. Fig. 1 - Unit 50VR -A

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Model 579F/580D. Sizes COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS. 3to25Tons. Form No. PDS 580D.36.

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons. (Unit shown with economizer and power exhaust.

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Advanced Product Data

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Model 655A Sizes

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3

Product Data. 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop Vertical Models Nominal Tons 15, 17.5, 20, 25, 27.5 Model Sizes 17, 20, 24, 28, 30

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DCG Commercial. Submittal Data Form

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PERFORMANCE, INNOVATION, RELIABILITY

Product Data. Features/Benefits. 50SX High Efficiency Single-Packaged Cooling Units. 2 to 5 Nominal Tons

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Product Data. Fig. 1 - Unit 50EZ -A

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

PAJ3. Product Specifications

Model 704B Sizes

Product Data 50TC. Cooling Only/Electric Heat Packaged Rooftop Vertical Models Nominal Tons 15, 17.5, 20, 25, 27.5 Model Sizes 17, 20, 24, 28, 30

WPH4 Product Specifications

Product Data. Features/Benefits. PERFORMANCE 13 50XP SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

Product Data. Fig. 1 - Unit 50VG -A

PACKAGE GAS HEATING/ELECTRIC COOLING, R 410A SINGLE PACKAGE ROOFTOP 3 5 TONS (1 & 3 Phase) BUILT TO LAST, EASY TO INSTALL AND SERVICE

Advanced Product Data

High Heat COP. High/Low Stage

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons

Product Data. Features/Benefits. 48TJ Single-Package Rooftop Units Electric Cooling/Gas Heating. 3 to 25 Nominal Tons

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

48KC Gas Heat/Electric Cooling Single Packaged Rooftop 14 SEER 3to5NominalTons. Product Data C08613

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Model 581B Sizes to12 1 2Tons

COMMERCIAL PRODUCTS CONDENSED CATALOG

WALL-MOUNT HEAT PUMPS - (60HZ)

30GT FLOTRONIC AIR-COOLED CHILLERS

Product Data. Features/Benefits. 50TJ Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz

582J GAS HEAT/ELECTRIC COOLING SINGLE PACKAGED ROOFTOP 14 SEER 3 TO 5 NOMINAL TONS. Product Data C (Shown with optional Louvered Hail Guard)

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Product Data. 48HJD,HJF HJ Single Package Rooftop Units. 12 to 20 Nominal Tons

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Product Data. Fig. 1 - Unit 50ES -A

Product Data. Features/Benefits. 48HJD,HJF HJ Single-Package Rooftop Units. 12 to 20 Nominal Tons

WJH4 Product Specifications

Transcription:

SUBJECT TO CHANGE WITHOUT NOTI CE TYPE OF SALE: 6JSS SHIPPING POINT: Lewisburg, TN PACKAGED ROOFTOP ELECTRIC COOLING UNITS 3, 4, 5, 6, 7.5, 8.5, 10 & 12.5 TONS units are highefficiency, singlepackaged electric cooling units that are prewired and precharged with environmentally sound (R410A) HFC refrigerant. Electric heat is available as a fieldinstalled accessory. The units are factory tested in the cooling mode. Models 036120 Certified to ISO 9001:2000 STANDARD FEATURES (R410A) HFC refrigerant ASHRAE 90.12004 compliant 13 SEER efficiency levels Energy Star qualified Singlestage cooling capacity control on all 036072 models and the 091,101 and 121 models. Rated in accordance with ARI Standard 210 (036060 sizes) and 360 (072 121 sizes) Designed in accordance with Underwriters Laboratories Standard 1995 Listed by UL and UL, Canada Singlestage cooling capacity control Exclusive noncorrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain Prepainted exterior panels and primercoated interior panels tested to 500 hours salt spray protection Acutrol refrigerant metering system Fully insulated cabinet Cooling operating range from 25 F up to 115 F using winter start kit, 40 Deg.F Std Access panels with easy grip handles and nostrip screw feature Twoinch disposable return air filters Toolless filter access door Standard belt drive, constant torque motor Advanced terminal board for simple safety circuit troubleshooting and control box arrangement Convertible from vertical to horizontal airflow for slab mounting Provisions for thruthebottom power entry capability Single point electric connections Full perimeter base rail with builtin rigging adapters and fork truck slots Scroll compressors with internal linebreak overload protection Copper tube, aluminum fin coils 24volt control circuit protected with resettable circuit breaker Permanently lubricated evaporatorfan motor Permanently lubricated, totally enclosed condenserfan motors Low pressure, freeze protection, and highpressure switches Liquid line filter drier standard STANDARD WARRANTY 5year electric heater 5year compressor 1year parts Sizes 036060 Sizes 072150 FACTORY INSTALLED OPTIONS INCLUDE BUT NOT LIMITED TO: Economizer and two position damper options Disconnect and convenience outlet options Multiple optional motor and pulley combinations Corrosion resistant options for evaporator and condenser coils FORM NO. SUPERSEDES PRICE SECTION.1PPC New (3 to 12.5 Tons) For a complete list of options and accessories, refer to the Specification Sheets / Catalog for this unit 1

SAP CATALOG ORDERING NOMENCLATURE Position No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Example: R A S 0 7 2 L 0 A B 0 A A A R = Rooftop A = Electric/Electric,Cooling Only TYPE S = Standard ASHRAE 90.12010 Efficiency EFFICIENCY 036 = 36,000 BTUH = 3 Tons 048 = 48,000 BTUH = 4 Tons 060 = 60,000 BTUH = 5 Tons 072 = 72,000 BTUH = 6 tons 090 = 90,000 BTUH = 7.5 tons ( 2 Compressor) 091 = 90,000 BTUH = 7.5 tons (Single Compressor) 101 = 102,000 BTUH = 8.5 tons (Single Compressor) 120 = 120,000 BTUH = 10 tons ( 2 Compressor) 121 = 120,000 BTUH = 10 tons (Single Compressor) 150 = 150,000 BTUH = 12.5 tons ( 2 Compressor) NOMINAL COOLING CAPACITY H = 208/230360 K = 208/230160 L = 460360 S = 575360 0 =No Heat SINGLE & 3PHASE R410A ROOFTOP PRODUCT MODEL IDENTIFICATION GUIDE VOLTAGE HEATING CAPACITY (See Spec Sheet for Actual Capacity) A = Standard Motor B = Higher Static Motor MOTOR ( Indoor Fan ) A = None B = Economizer w/bararelief, OA Temp sensor E = Economizer w/bararelief + CO2 Sensor, OA Temp sensor H = Economizer w/bararelief, enthalpy sensor L = Economizer w/bararelief + CO2 Sensor, enthalpy sensor P = 2Position damper w/barorelief OUTDOOR AIR OPTIONS / CONTROL (See Spec Sheet for Details) 0A = No Options 4B = NonFused Disconnect AT = Nonpowered 115v C.O. BR = Supply Air Smoke Detector 7C = NonFused Disconnect + NonPowered 115v C.O. 7K = NonFused Disconnect + NonPowered 115v C.O.+ SA Smoke detector 8A = NonFused Disconnect + SA Smoke detector FACTORY INSTALLED OPTIONS (See Spec Sheet for Details) A = Aluminum / Copper Cond & Evap Coil B = Precoat Alum/CU Cond II Alum / CU Evap C = ECoated Alum/Cu Cond II Alum / CU Evap D = ECoated Alum / Cu Cond & Evap E = Cu / Cu Cond & Alum/Cu Evap F = Copper/Copper Cond & Evap G = Alum / Alum Cond, Alum / Copper Evap Coil A = Standard Packaging B = Less Than Truckload (LTL) Packaging CONDENSER / EVAPORATOR COIL CONFIGURATION (See Spec Sheet for Details) PACKAGING LEGEND SAP Sales Order Process NOTE: The example model number 072L0AB0AAA designates a 6 ton 460360 volt electric cooling, accessory electric heating rooftop unit with standard coils and an EconoMi$er IV controlled by OA Temperature. 1. Future availability 2

ODS CATALOG ORDERING BASE UNIT MASTER PRICES SINGLE STAGE COOLING MODELS VOLTSPHASE (60 Hz) COOLING CAPACITY (Btuh)* APPROX. SHIP. WT. (Lbs) 036S0AA0AAA 5753 34,600 477 036K0AA0AAA 208/2301 34,600 477 036H0AA0AAA 208/2303 34,600 477 036L0AA0AAA 4603 34,600 477 048S0AA0AAA 5753 45,000 530 048K0AA0AAA 208/2301 45,000 530 048H0AA0AAA 208/2303 45,000 530 048L0AA0AAA 4603 45,000 530 060S0AA0AAA 5753 59,000 560 060K0AA0AAA 208/2301 59,000 560 060H0AA0AAA 208/2303 59,000 560 060L0AA0AAA 4603 59,000 560 072S0AA0AAA 5753 70,000 645 072H0AA0AAA 208/2303 70,000 645 072L0AA0AAA 4603 70,000 645 091S0AA0AAA 5753 88,000 780 091H0AA0AAA 208/2303 88,000 780 091L0AA0AAA 4603 88,000 780 101S0AA0AAA 5753 97,000 880 101H0AA0AAA 208/2303 97,000 880 101L0AA0AAA 4603 97,000 880 121S0AA0AAA 5753 117,000 935 121H0AA0AAA 208/2303 117,000 935 121L0AA0AAA 4603 117,000 935 ORDERING BASE UNIT MASTER PRICES TWOSTAGE COOLING MODELS VOLTAGE/ PHASE/Hz COOLING CAPACITY APPROXIMATE SHIPPING WT. (lbs) 090S0AA0GAA 575360 83,000 830 090H0AA0GAA 208/230360 83,000 830 090L0AA0GAA 460360 83,000 830 120S0AA0GAA 575360 114,000 900 120H0AA0GAA 208/230360 114,000 900 120L0AA0GAA 460360 114,000 900 150S0AA0GAA 575360 140,000 1080 150H0AA0GAA 208/230360 140,000 1080 150L0AA0GAA 460360 140,000 1080 * Rated in accordance with ARI Standards 210/240, 270 (036121). ALL of the above models comply with the minimum efficiency requirements as defined in the ASHRAE 90.12004 Energy Standard. To determine if compliance with this standard pertains to a given geographical area of the United States, check with local or state municipal building codes or visit the following Internet website: http://bcapenergy.org 3

POSITION 9 INDOOR MOTOR OPTIONS RTU Model Number example: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Ordering Position Number: R A S 0 7 2 L 0 A B 0 A A A 9 th DIGIT ORDER CODE A B Standard Static Option High Static Option MASTER PRICE ADDERS VOLTAGE 036 048 060 072 090 / 091 101 120 / 121 150 208/230160 Std. Std. Std. Std. Std. Std. Std. Std. 208/230360 or 460360 Std. Std. Std. Std. Std. Std. Std. Std. 575360 Std. Std. Std. Std. Std. Std. Std. Std. 208/230160 NC NC n/a n/a n/a n/a n/a 208/230360 Cost Cost Cost Cost Cost Cost or 460360 Add Add Add Add Add Add 575360 Cost Cost Cost Cost Cost Cost Add Add Add Add Add Add POSITION 10 OUTDOOR AIR OPTIONS RTU Model Number example: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Ordering Position Number: R A S 0 7 2 L 0 A B 0 A A A 1 10 th DIGIT ORDER MASTER PRICE ADDER CODE 036072 090150 A None Std. Std. B Temperature Economizer w/ Barometric relief E Temperature Economizer w/ Barometric relief and CO2 1 H Enthalpy Economizer w/ Barometric relief L Enthalpy Economizer w/ Barometric relief and CO2 1 P Motorized 2 pos damper w/ Barometric relief Future availability NOTES: 1. EconoMi$er IV (Vertical airflow only): 100%+ barometric relief capability. Geardriven 3position damper. Includes occupied/unoccupied minimum position and maximum position. Directmount Belimo spring return actuator closes damper on power loss. Dry bulb outdoor air control standard. Enthalpy control available as an accessory. Solidstate control module for nonddc applications OAT and SAT sensors factory installed 4

POSITION 11 & 12 FACTORYINSTALLED OPTIONS RTU Model Number example: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Ordering Position Number: R A S 0 7 2 L 0 A B 0 A A A To determine the Option Ordering Code and place an order: 1. Select the desired combination of options from the table below. The 2letter Ordering Code is listed to the left of the Option combination. 2. Enter the 2letter Code as the 11th and 12th digits of the Base Unit Ordering Number. 3. To determine Master Price for FIOP unit, add price of option combination selected to master price of base unit. FACTORYINSTALLED OPTION S OPTION NOTES 2 NonFused Disconnect Switch 2 5 Unpowered Convenience Outlet 3 9 Supply Air Smoke Detector FACTORYINSTALLED OPTION PRICES ORDER OPTIONS MASTER PRICE ADDER CODE 036072 090 150 0A None Standard Standard 4B 2 7C 2,5 7K 2,5,9 8A 2,9 AT 5 BR 5,9 NOTES: 2. Nonfused disconnect switch cannot be used when rooftop MOCP electrical rating exceeds 80 amps. 3. Unpowered convenience outlet requires separate field supplied 115120v power source. Transformer is NOT included. 5

POSITION 13 CORROSION RESISTANT COILS RTU Model Number example: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Ordering Position Number: R A S 0 7 2 L 0 A B 0 A A A Environment EnviroShield Description Standard NonCorrosive Mild Coastal Moderate Coastal Severe Coastal Industrial Industrial & Coastal Alum Fin / Cu Tube X PreCoated Al / Cu X Cu / Cu X ECoated Al / Cu X X ECoated Cu / Cu X SINGLE STAGE ( 1 Compressor ) COOLING CAPACITY MODELS ( 091121 ONLY) 13 th MASTER PRICE ADDERS Digit Condenser Evaporator Order Coil Coil Code (Fins/Tube) (Fins/Tube) 036 048 060 072 091 101 121 A Al/Cu Al/Cu Std. Std. Std. Std. Std. Std. Std. B Pre Al/Cu C ECoated C t d Al/Cu D ECoated Al/C ECoated E Cu/Cu Al/C Al/Cu Al/C F Cu/Cu Cu/Cu TWO STAGE ( Dual Compressor ) COOLING CAPACITY MODELS ( 090150 ONLY) 13 th MASTER PRICE ADDERS Digit Condenser Evaporator Order Coil Coil 090 120 150 Code (Fins/Tube) (Fins/Tube) G AL/AL AL/CU Std. Std. Std. K ECoat Al / Al AL/CU Notes: 1. Dual stage ( 2 compressor ) models are equipped with a microchannel (MCHX) aluminum / aluminum condenser coil. 2. No MCHX factory coating options are currently available. 6

FIELDINSTALLED ACCESSORIES Electric Heaters Unit Size NOM. VPhHz 208/230160 IFM TYPE STD/MED Electric Heater Part Number CRHEATER101A00 CRHEATER102A00 CRHEATER103B00 CRHEATER104B00 (2) CRHEATER102A00 Nominal 4.4 6.5 8.7 10.5 13.0 Application 3.3/4.0 4.9/6.0 6.5/8.0 7.9/9.6 9.8/11.9 Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet CRSINGLE040A00 CRSINGLE040A00 036 208/230360 STD/MED/ CRHEATER101A00 CRHEATER102A00 CRHEATER103B00 CRHEATER104B00 CRHEATER105A00 4.4 6.5 8.7 10.5 3.3/4.0 4.9/6.0 6.5/8.0 7.9/9.6 460360 STD/MED/ CRHEATER106A00 CRHEATER107A00 CRHEATER108A00 CRHEATER109A00 6.0 8.8 11.5 14.0 5.5 8.1 10.6 12.9 208/230160 STD/MED CRHEATER101A00 CRHEATER103B00 (2) CRHEATER102A00 (2) CRHEATER103B00 (2) CRHEATER104B00 4.4 8.7 13.0 17.4 21.0 3.3/4.0 6.5/8.0 9.8/11.9 13.1/ 15.8/19.3 CRSINGLE040A00 CRSINGLE040A00 CRSINGLE040A00 048 208/2303 60 STD/MED/ CRHEATER102A00 CRHEATER103B00 CRHEATER105A00 (2) CRHEATER104B00 6.5 8.7 21.0 4.9/6.0 6.5/8.0 15.8/19.3 CRSINGLE038A00 460360 STD/MED/ CRHEATER106A00 CRHEATER108A00 CRHEATER109A00 (2) CRHEATER108A00 6.0 11.5 14.0 23.0 5.5 10.6 12.9 21.1 GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. 7

FIELDINSTALLED ACCESSORIES Electric Heaters (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size 060 072 NOM. VPhHz 208/230160 208/230360 460360 208/230360 460360 IFM TYPE STD/MED STD/MED/ STD/MED/ STD/MED/ STD/MED/ Electric Heater Part Number CRHEATER102A00 CRHEATER103B00 (2) CRHEATER102A00 (2) CRHEATER103B00 (2) CRHEATER104B00 CRHEATER102A00 CRHEATER104B00 CRHEATER105A00 (2) CRHEATER104B00 CRHEATER104B00,105 A00 CRHEATER106A00 CRHEATER108A00 CRHEATER109A00 (2) CRHEATER108A00 CRHEATER108A00,109 A00 CRHEATER102A00 CRHEATER104B00 CRHEATER105A00 (2) CRHEATER104B00 CRHEATER104B00,105 A00 CRHEATER106A00 CRHEATER108A00 CRHEATER109A00 (2) CRHEATER108A00 CRHEATER108A00,109 A00 Nominal 6.5 8.7 13.0 17.4 21.0 6.5 10.5 21.0 26.5 6.0 11.5 14.0 23.0 25.5 6.5 10.5 21.0 26.5 6.0 11.5 14.0 23.0 25.5 Application 4.9/6.0 6.5/8.0 9.8/11.9 13.1/ 15.8/19.3 4.9/6.0 7.9/9.6 15.8/19.3 19.9/24.3 5.5 10.6 12.9 21.1 23.4 4.9/6.0 7.9/9.6 15.8/19.3 19.9/24.3 5.5 10.6 12.9 21.1 23.4 Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet CRSINGLE040A00 CRSINGLE040A00 CRSINGLE040A00 CRSINGLE038A00 CRSINGLE038A00 CRSINGLE037A00 CRSINGLE038A00 CRSINGLE038A00 CRSINGLE037A00 CRSINGLE037A00 GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. 8

FIELDINSTALLED ACCESSORIES Electric Heaters (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size 091(Single Stage Cooling) NOM. VPhHz 208/230360 460360 IFM TYPE STD MED STD/MED/ Electric Heater Part Number CRHEATER111A00,117A00 CRHEATER111A00,117A00 CRHEATER111A00,117A00 CRHEATER114A00 Nominal 24.8 24.8 24.8 27.8 Applicatio n 18.6/22.8 18.6/22.8 18.6/22.8 25.5 Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet CRSINGLE045A00 1 CRSINGLE045A00 CRSINGLE045A00 CRSINGLE044A00 575360 STD/MED 17.7 35.5 17.7 2 GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. 1 required with Power Exhaust 2 CRSINGLE044A00 required with Power Exhaust 9

FIELDINSTALLED ACCESSORIES Electric Heaters (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size 090 (Two Stage Cooling) NOM. VPhHz 208/230360 460360 575360 IFM Type STD MED STD/MED STD/MED Electric Heater Part Number CRHEATER111A00,117A00 CRHEATER111A00,117A00 CRHEATER111A00,117A00 CRHEATER114A00 CRHEATER114A00 Nominal 24.8 24.8 24.8 27.8 27.8 Application 18.6/22.8 18.6/22.8 18.6/22.8 25.5 25.5 17.7 35.5 17.7 35.5 Single Point Kit Part Number No Convenience Outlet Or Unpowered Convenience Outlet CRSINGLE045A00 1 CRSINGLE045A00 CRSINGLE045A00 CRSINGLE044A00 2 CRSINGLE044A00 2 A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. 1 required with Power Exhaust 2 CRSINGLE044A00 required with Power Exhaust 10

ELECTRIC HEATER SELECTION (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size NOM. VPhHz IFM Type Electric Heater Part Number Nominal Application Single Point Kit Part Number No Convenience Outlet Or Unpowered Convenience Outlet 208/203360 STD/MED CRHEATER111A00,117A00 CRHEATER111A00,117A00 24.8 24.8 18.6/22.8 18.6/22.8 ** 101 460360 STD/MED CRHEATER114A00 CRHEATER114A00 27.8 27.8 25.5 25.5 575360 STD/MED/ 17.7 35.5 GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. ** required with power exhaust 3 required with Power Exhaust 11

ELECTRIC HEATER SELECTION (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size NOM. VPhHz IFM TYPE Electric Heater Part Number Nominal Application Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet STD,117A00,110A00 37.6/45.9 208/230360 MED,117A00,110A00 37.6/45.9 ** 121 (Single Stage Cooling) 460360 575360 STD MED STD/MED,117A00,110A00,113A00,113A00,113A00,119A00,119A00 37.6/45.9 45.9 45.9 45.9 17.7 35.5 17.7 35.5 1 1 GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. ** required with power exhaust 1 required with Power Exhaust 12

ELECTRIC HEATER SELECTION (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size 120 (Two Stage Cooling) NOM. VPhHz 208/230360 460360 575360 IFM TYPE STD MED STD MED STD/MED Electric Heater Part Number,117A00,110A00,117A00,110A00,117A00,110A00,113A00,113A00,113A00,119A00,119A00 Nominal Application 37.6/45.9 37.6/45.9 37.6/45.9 45.9 45.9 45.9 17.7 35.5 17.7 35.5 Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet ** 1 1 GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. ** required with power exhaust 1 required with Power Exhaust 13

ELECTRIC HEATER SELECTION (cont) ELECTRIC HEATERS Fully assembled for easy slidein installation. Refer to charts below for wide range of ULapproved kws per unit. Control twostage and dual heaters with twostage heating thermostat. Must use accessory singlepoint electrical connection package where listed. Unit Size 150 (Two Stage Cooling) NOM. VPhHz 208/230360 460360 IFM TYPE STD MED STD MED STD Electric Heater Part Number,117A00,110A00,117A00,110A00 STANDARD UNIT,117A00,110A00,113A00,113A00,113A00,119A00 Nominal Application 37.6/45.9 37.6/45.9 37.6/45.9 45.9 45.9 45.9 17.7 35.5 Single Point Kit Part Number No Convenience Outlet or Unpowered Convenience Outlet 1 575360 MED,119A00 17.7 35.5,119A00 17.7 35.5 1 GENERAL: A. MEDIUM indoor fan motor / drives available from FAST parts where available (see product specification sheets for details) B. For those kws where a single heater package is furnished, heaters are available in single stage. For those electric heater accessories with two heater packages, the opportunity exists for twostage capability. C. Nonfused disconnect switch cannot be used when rooftop electrical ratings exceed 80 amps. D. Only those heaters and combinations of heaters shown above are UL approved. ** required with power exhaust 1 required with Power Exhaust 14

FIELD INSTALLED ACCESSORIES (cont) ELECTRIC HEATERS (See selection on previous pages) REQUIRED HEATER MASTER PRICE ORDER (S) CRHEATER101A00 CRHEATER102A00 CRHEATER103B00 CRHEATER104B00 CRHEATER105A00 CRHEATER106A00 CRHEATER107A00 CRHEATER108A00 CRHEATER109A00 CRHEATER111A00 CRHEATER114A00 SINGLEPOINT KITS (See applications on previous pages) ORDER MASTER PRICE CRSINGLE037A00 CRSINGLE038A00 CRSINGLE040A00 CRSINGLE044A00 CRSINGLE045A00 15

FIELD INSTALLED ACCESSORIES ECONOMI$ER IV (CONTROLLER INCLUDED) VERTICAL APPLICATION USAGE APPROX SHIP WT (Lbs) Vertical EconoMi$er IV with solidstate controller, geardriven, DNECOMZR020A02 1 3position modulating damper, spring return actuator, up to 100% barometric relief, supply and outdoor air sensors, and 036072 55 CO2 sensor compatible, for use in nonddc applications. Vertical EconoMi$er IV with solidstate controller, geardriven, DNECOMZR021A03 1 3position modulating damper, spring return actuator, up to 100% barometric relief, supply and outdoor air sensors, and 090150 80 CO2 sensor compatible, for use in nonddc applications. NOTE: 1 EconoMi$er IV, Manual Damper and 2Pos Motorized Damper are all mutually exclusive and cannot be installed together. HORIZONTAL APPLICATION USAGE APPROX SHIP WT (Lbs) Horizontal EconoMi$er IV with solidstate controller, geardriven, 3position modulating damper, spring return actuator, DNECOMZR024A02 1 up to 100% barometric relief, supply and outdoor air sensors, 036072 85 and CO2 sensor compatible, for use in nonddc applications. Horizontal EconoMi$er IV with solidstate controller, geardriven, 3position modulating damper, spring return actuator, DNECOMZR025A02 1 up to 100% barometric relief, supply and outdoor air sensors, 090150 105 and CO2 sensor compatible, for use in nonddc applications. NOTE: 1 EconoMi$er IV, Manual Damper and 2Pos Motorized Damper are all mutually exclusive and cannot be installed together. 16

FIELD INSTALLED ACCESSORIES ECONOMIZER SENSORS ECONOMIZER SENSOR USAGE CHART DESIRED CONTROL METHOD Single Dry Bulb Control ECONOMI$ER IV 1 REQUIRED FIELDINSTALLED SENSOR(S) None. Outside Air dry bulb sensor is factory installed. Differential Dry Bulb Control (1) DNTEMPSN002A00 Single Enthalpy Control (1 AXB078ENT Differential Enthalpy Control (1) AXB078ENT & (1) DNENTDIF004A00 To Add CO 2 DCV Control with above: Duct Mount (1) DNCBDIOX005A00 NOTES: 1. OAT and SAT sensors included for EconoMi$er IV. APPLICATION USAGE DNTEMPSN002A00 Outdoor or Return Dry Bulb Temperature Sensor used with Electro Mechanical control. EconoMi$er IV DNCBDIOX005A00 CO2 Sensor for use in return airstream. Also includes Aspirator Box required for Duct Mounting. EconoMi$er IV AXB078ENT Accusensor II Economizer Differential Enthalpy Control Upgrade EconoMi$er IV DNENTDIF004A00 Return Air Enthalpy Sensor used with ElectroMechanical controls, use with AXB078ENT for differential enthalpy control. EconoMi$er IV 17

FIELD INSTALLED ACCESSORIES POWER EXHAUST OPTIONS VERTICAL 1 DNPWREXH030A01 Power Exhaust System (208/230160) DNPWREXH021A01 Power Exhaust System (460360) DNPWREXH022A01 Power Exhaust System (208/230160) DNPWREXH023A01 Power Exhaust System (460360) NOTES: 1 Vertical Power Exhaust requires a vertical Economizer 2 Vertical Power Exhaust package includes exhaust hood, screens, and propeller fan system APPLICATION USAGE 036072 208/230160 208/230360 036072 460360 090150 208/230360 090150 460360 DNPWREXH028A01 HORIZONTAL Horizontal Power Exhaust (208/230160) Mounted on Return Ductwork Horizontal Power Exhaust (460360) Mounted on DNPWREXH029A01 Return Ductwork NOTES: 1 Horizontal Power Exhaust should be ductmounted in the return duct 2 Horizontal Power Exhaust package includes exhaust hood, screens, and propeller fan system APPLICATION USAGE All 208/230160 208/230360 575360 All 460360? FAST # HT01AH859 / 1171494 575V TRANSFORMER Transformer for conversion from 575 volt to 208/230 volt power exhaust applications. APPLICATION USAGE Convert from 575 Volt to 208 230 Volt Power Exhaust applications. NOTES: 1. Vertical power exhaust package includes exhaust hood, screens and propeller fan system. 2. 24 Roof curbs are NOT required with vertical power exhaust. 3. Horizontal power exhaust should be ductmounted in the return ductwork and is supplied with a single fan and wiring harness. 4. Both vertical and horizontal power exhaust packages can be used with either EconoMi$er IV. In either case, the power exhaust is controlled by the EconoMi$er IV controller. 5. Order HT01AH859 / FAST# 1171494for 575V applications. 18

FIELD INSTALLED ACCESSORIES OUTDOOR AIR DAMPER OPTIONS MANUAL OUTDOOR AIR DAMPERS APPLICATION USAGE DNMANDPR001A03 25% Open Manual Outdoor Air Damper Package 036072 1 CRMANDPR001A02 50% Open Manual Outdoor Air Damper Package 036072 1 DNMANDPR002A03 25% Open Manual Outdoor Air Damper Package 090150 1 CRMANDPR002A02 50% Open Manual Outdoor Air Damper Package 090150 1 1 EconoMi$er IV, Manual Damper and 2Pos Motorized Damper are all mutually exclusive and cannot be installed together. MOTORIZED OUTDOOR AIR DAMPERS APPLICATION USAGE CRTWOPOS010A00 Motorized 2position outdoor air damper (25100% 036072 1 Outdoor Air) CRTWOPOS011A00 Motorized 2position outdoor air damper 091150 1 1 EconoMi$er IV, Manual Damper and 2Pos Motorized Damper are all mutually exclusive and cannot be installed together. NOTES: 1. Manual dampers include hood assembly, bird screen, adjustable damper blade (to allow up to the rated outdoor air %), and bottom panel with opening. 2. Motorized dampers include bottom panel with opening (100% twoposition damper includes 30% barometric relief capability), and adjustable damper (to allow up to the rated outdoor air %). 3. Motorized dampers will close on loss of power to the rooftop unit. 4. Manual and Motorized dampers are not compatible with a vertical power exhaust module. 19

CRRFCURB001A01 CRRFCURB003A01 CRRFCURB002A01 CRRFCURB004A01 FIELD INSTALLED ACCESSORIES ROOF CURB OPTIONS 14inch Tall Roof Curb. Complies with NRCA standards. Ductwork attaches to the roof curb. Includes thruthebottom capability. 14inch Tall Roof Curb. Complies with NRCA standards. Ductwork attaches to the roof curb. Includes thruthebottom capability. 24inch Tall Roof Curb. Complies with NRCA standards. Ductwork attaches to the roof curb. Includes thruthebottom capability. 24inch Tall Roof Curb. Complies with NRCA standards. Ductwork attaches to the roof curb. Includes thruthebottom capability. APPLICATION USAGE 036072 090150 036072 090150 CRBTMPWR001A01 CRBTMPWR002A01 CRBTMPWR003A01 CRBTMPWR004A01 THRUTHEBOTTOM CONNECTION KITS Thruthebottom electrical connections and thruthecurb (not thru the bottom) gas connections. Includes a 3/4inch diameter liquid tight conduit fitting for high voltage power wires and (2) 1/2inch diameter liquid tight conduit fittings for thermostat wires and convenience outlet wires. Includes a 3/4inch inside pipe coupling and gas plate assembly for thruthecurb connections. Provides for watertight seals. Thruthebottom electrical connections and thruthecurb (not thru the bottom) gas connections. Includes a 11/4inch diameter liquid tight conduit fitting for high voltage power wires and (2) 1/2inch diameter liquid tight conduit fittings for thermostat wires and convenience outlet wires. Includes a 3/4inch inside pipe coupling and gas plate assembly for thruthecurb connections. Provides for watertight seals. Thruthe bottom power, control and gas connections. Includes a 3/4inch diameter liquid tight conduit fitting for high voltage power wires, (2) 1/2inch diameter liquid tight conduits for thermostat wires and convenience outlet wires and 1/2inch gas adapter fitting for gas piping. Provides for watertight seal. Thruthe bottom power, control and gas connections. Includes a 11/4inch diameter liquid tight conduit fitting for high voltage power wires, (2) 1/2inch diameter liquid tight conduits for thermostat wires and convenience outlet wires and 3/4inch gas adapter fitting for gas piping. Provides for watertight seal. APPLICATION USAGE 036072 090150 036072 090150 NOTE: Access to the bottom of the RTU is required to install a THRUTHEBOTTOM Connection Kit. Recommend installing kit prior to installing RTU on roof curb. CONTROL UPGRADE KITS APPLICATION USAGE DNSTATUS001A00 Fan/Filter Status Switch Indicator light not included Std. Control Time Guard II Automatically prevents the compressor from restarting DNTIMEGD001A00 for at least 4 minutes and 45 seconds after shutdown of the compressor. All Sizes Not required when a corporate programmable thermostat is applied or (1 required) with a PremierLink or RTUMP control. DNPHASE3001A02 Phase Monitor Control Provides phase loss/phase reversal protection All 3Ph 208230 & 460v KA99ZT003 / 1178184 Remote keyed attenuator / test / reset station for use with factory installed smoke detectors. Includes power, alarm & trouble indicator lights. All 20

FIELD INSTALLED ACCESSORIES / FAST # AXB035LAA s/a CPLOWAMB001A00 32LT900301 32LT900611 32LT901247 32LT901647 LOW AMBIENT CONTROLS Motormaster II Low Ambient Control Enables cooling system to operate down to 0 F by cycling condenser fan on and off. The control is activated by a temperature sensor. No motor changeout required. Motormaster I SinglePhase SolidState Variable Speed Motor Controller enables cooling down to 20 F by varying the speed on the condenser fan. Motormaster I SinglePhase SolidState Variable Speed Motor Controller enables cooling down to 20 F by varying the speed on the condenser fan. Motormaster I Single Phase SolidState Variable Speed Motor Controller enables cooling down to 20 F by varying the speed on the condenser fan. Motormaster I Single Phase SolidState Variable Speed Motor Controller enables cooling down to 20 F by varying the speed on the condenser fan. HC40GE233 / 1171974 Motormaster I Compatible Condenser Fan Motor HC40GE463 / 1171975 Motormaster I Compatible Condenser Fan Motor HC91CL010 / 171807 MFD 10 HC93CA013 / 1175708 Dual MFD 10 + 10 HC98JA048 / 1173702 Dual MFD 45 + 10 HC98JA073 / 1177750 Dual MFD 70 + 10 HC98JA083 / 1173703 Dual MFD 80 + 10 NOTES: USED WITH 208/2301 208/2303 460360 All Sizes Refer to Motormaster I Usage Table Refer to Motormaster I Usage Table Refer to Motormaster I Usage Table * FAST List Price Subject to change on a quarterly basis and should be verified with FAST prior to quoting. Sizes 036072 require one (1) Low Ambient Controller and one (1) compatible condenser fan motor for changeout. Sizes 090121 require one (1) Low Ambient Controller and one (2) compatible condenser fan motor for changeout. / FAST# HD52AK002 / 1178268 HD52GE577 / 1178269 CRLOWAMB030A00 CRLOWAMB031A00 CRLOWAMB032A00 LOW AMBIENT CONTROLS (SIZE 150 ONLY) MASTER PRICES Outdoor Fan Motor Required on units with Motormaster V Outdoor Fan Motor Required on units with Motormaster V Motormaster V Low Ambient Kit. Mechanical cooling operation down to 20 F ( 29 C) Motormaster V Low Ambient Kit. Mechanical cooling operation down to 20 F ( 29 C) Motormaster V Low Ambient Kit. Mechanical cooling operation down to 20 F ( 29 C). APPLICATION USAGE 150 Size 208/230360 460360 150 Size 575360 150 Size 208/230360 150 Size 460360 150 Size 575360 * FAST / RCD List Price Subject to change on a quarterly basis and should be verified with FAST / RCD prior to quoting. 21

FIELD INSTALLED ACCESSORIES LOW AMBIENT CONTROLS Motormaster I Usage and Parts Table (036121 Models) MOTORMASTER I UNITS VOLTAGE MOTOR CAPACITOR CONTROLLER Table 5 Single Phase Unit Capacitor Replacement DUAL FAST / RCD UNITS MFD* Part # 208/230160 HC40GE233 See table 5 32LT900301 036K 45 + 10 HC98JA048 036060 208/230360 575360* HC40GE233 Replace with HC91CL010 32LT900301 048K 70 + 10 HC98JA073 460360 HC40GE463 Replace with HC91CL010 32LT900611 060K 80 + 10 HC98JA083 208/230360 HC40GE233 Keep Factory Installed 32LT900301 *Compressor shares capacitor with the OD motor, the first number is for compressors and the second number is for OD motor 072 460360 HC40GE463 Replace with HC91CL010 32LT900611 091121 208/230360 (Single 575360** Compressor Units) 460360 090120 (Dual Compressor Units with Microchannel Al/Al condenser coil) 575360* HC40GE233 208/230360 575360** 460360 (2) HC40GE233 (2) HC40GE463 (2) HC40GE233 (2) HC40GE463 Replace with HC91CL010 Replace with HC93CA013 Replace with HC93CA013 Keep Factory Installed Keep Factory Installed 32LT900301 32LT900301 32LT900611 32LT901247 32LT901247 The Capacitor Straps in the unit can be reused. If needed part numbers are as follows: HC91CL005 / FAST# 1172149 & HC91CL010 / FAST# 1171807 use HC98ZY071/FAST# 1171552, and HC93CA013 / FAST# 1175708 uses 50DK507522 / FAST# 1171537. *Transformer HT01AH856 / FAST# 1178302 (0.75kva, 575v to 230v) and transformer bracket 50DK502263 / FAST# 1171069 are recommended. **Transformer HT01AH859 / FAST# 1171494 (1kva, 575v to 230v) and transformer bracket 50DK502263 / FAST# 1171069 are recommended. 22