PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Similar documents
PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra Centrifugal Fan

Centrif Duo & Centrif Duo Plus

Silhouette Installation and Wiring Instructions

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra SELV

Lo-Carbon SELV Tempra

Lo-Carbon Quadra Centrifugal Fan

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Lo-Carbon T-series Window & Roof Models

SUPER T WALL FANS. Installation and Wiring Instructions

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

HR200WK Through the wall Heat Recovery Ventilator

Installation and Wiring Instructions

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Sentinel Kinetic MVHR RANGE

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Lo-Carbon PoziDry Pro

100 FLUEBOOST

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

FLUEBOOST. flueboost 350 gas fire model

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Warnings, Safety Information and Guidance

Installation & Operating Instructions

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Lucci Designer Hi Flow Exhaust Fan

Purge Ventilation Unit. Product Manual. ventilation systems TP625

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

Xpelair Simply Silent TM Contour Fan

Xpelair Simply Silent TM DX100 Fan

irconcentre.co.uk airooncentre.co.uk

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

Installation & Operating Instructions

CLASSIC-100. Instruction leaflet. Instruction leaflet

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

PUREAIR SENSE. Instruction Manual. A product by. B at hroom Fan wi t h O dour Sen se Tec h n ology Vent-Axia PureAir Sense F&W Manual.

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Xpelair Simply Silent DX150

Xpelair Simply Silent DX100

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Stainless Steel Chimney Extractor

Wind. Service instruction

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

Thank you for choosing EnviroVent

USER MANUAL. PEDESTAL FAN (16 Inch)

KADO LUX LED EXHAUST FAN 200

AXIAL FANS USER S MANUAL

Stainless Steel Chimney Extractor

HOTLINE:

OPERATING INSTRUCTIONS

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

90cm Chimney Extractor

60cm Integrated Turbo Extractor

Xpelair Simply Silent DX100B

Installation instructions. and User guide. Freestanding canopy NZ AU. HF60CSW2 & HF60CSX2 models

EN Instruction on mounting and use

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

750MM INDUSTRIAL PEDESTAL DRUM FAN

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

Stainless Steel T-Box Extractor

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

60cm Canopy Extractor

Wiring the fan correctly...

Installation instructions. and User guide. Slideout rangehood NZ AU. HS60CSRX2, HS60CSRW2, HS90CSX2, HS60CSW2, HS60CSX2, HS60CIW2, HS60CIX2 models

CG60/ 70/ 80/ 90/ 100 SS/BK

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

INSTALLATION INSTRUCTIONS USER GUIDE

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

aura-t TP536/GBR ventilation systems

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

November This product has been reconfigured Please read these instructions

WHHR Midi & Midi Lite

QUALITY SPACE HEATERS

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Transcription:

Eclipse Installation and Wiring Instructions Models Eclipse 100X Eclipse 100XP Eclipse 100XT Eclipse 150X Eclipse 150XP Ref No. 42 73 10A 42 72 81A 42 72 82A 42 72 83A 42 73 13A 220-240V~50Hz PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Installation and Wiring Instructions for the Eclipse Range of Extractor Fans. IMPORTANT: READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION DO NOT install this product in areas where the following may be present or occur: Excessive oil or a grease laden atmosphere. Corrosive or flammable gases, liquids or vapours. Ambient temperatures higher than 40 C or less than 5 C. Possible obstructions which would hinder the access or removal of the Fan. SAFETY AND GUIDANCE NOTES A. All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of your country and MUST be installed by a suitably qualified person. B. The Fan should be provided with a local isolator switch capable of disconnecting all poles, having a contact separation of at least 3mm. C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label. D. The Fan should only be used in conjunction with the appropriate Vent-Axia products. E. The fan should only be used in conjunction with fixed wiring. F. When the Fan is used to remove air from a room containing a fuel-burning appliance, ensure that the air replacement is adequate for both the fan and the fuel-burning appliance. G. The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time. H. Where ducted Fans are used to handle moisture-laden air, a condensation trap should be fitted. Horizontal ducts should be arranged to slope slightly downwards away from the Fan. I. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. J. Children should be supervised to ensure that they do not play with the appliance.

K. Stationary appliances not fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under over voltage category III, the instructions state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. DESCRIPTION The Eclipse 100mm axial extract fans are suitable for domestic bathrooms and W.C s. The Eclipse 150mm axial extract fans are suitable for domestic kitchens and utility rooms. They are available as wall or panel mounted models with shutter, pullcord & timer combinations. ACCESSORIES (not supplied) WALL FITTING KIT A range of 100mm and 150mm wall kits are available for installing into most walls using telescopic liners supplied. Fan Stock Reference Size White Brown 100mm 254102 254100 150mm 140902A 140903A A. INSTALLATION PANEL MOUNTING 1. Cut a 105mm diameter hole for 100mm fans or a 155mm diameter hole for 150mm fans through the panel. 2. Remove the Inner Grille [A]. Insert a small bladed screwdriver between the bottom blade of the Inner Grille and the Outer Bezel [B]. Gently lever the bottom grille blade upwards and away from the Outer Bezel. 3. Remove Outer Bezel. Remove the two screws retaining the Bezel to the Base Housing [D]. Please note that the Outer Bezel is also secured into position via the central section and will require a small force to remove it. 4. Remove the Cable Grommet [C], and push the cable through the grommet including the outer core secondary insulation. Please ensure the correct cable is used as outlined in Section C WIRING. 5. Slide the Base Housing into the hole in the panel and secure into position using screws and fixings provided. 6. Ensure the fan blade rotates freely. 7. Select and follow the appropriate wiring diagram in Section C WIRING. 8. Replace the Outer Bezel ensuring the centre section positively clips into the Base Housing by carefully pushing from the centre. 9. Switch the mains power supply on and check the fan is operating correctly. WALL MOUNTING (For wall installations see accessories table for a suitable wall kit). 1. Cut a 115mm diameter hole for 100mm fans or a 170mm diameter hole for 150mm fans through the wall and insert the wall sleeve and cement both ends into position flush with the wall faces. The wall sleeve should be angled downwards away from the fan to allow any condensation to drain to the outside wall. 2. Fix the outer grille as required, ensuring the louvres are pointing downwards.

3. Remove the Inner Grille [A]. Insert a small bladed screwdriver between the bottom blade of the Inner Grille and the Outer Bezel [B]. Gently lever the bottom grille blade upwards and away from the Outer Bezel. 4. Remove the Outer Bezel. Remove the two screws retaining the Bezel to the Base Housing [D]. Note that the Outer Bezel is also secured into position via the central section and will require a small force to remove it. 5. Remove the Cable Grommet [C], and push the cable through the grommet including the outer core secondary insulation. Please ensure the correct cable is used as outlined in Section C WIRING. 6. Slide the Base Housing into the Wall Liner and secure into position by tightening the Quick Clip screws [F] (fig. 2). 7. Ensure the fan blade rotates freely. 8. Select and follow the appropriate wiring diagram in Section C WIRING. 9. Replace the Outer Bezel ensuring the centre section positively clips into the Base Housing by carefully pushing from the centre. 10. Switch the mains power supply on and check the fan is operating correctly. B. SETUP WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. TIMER ADJUSTMENT (T model) The overrun time period is factory set to 15 minutes. The overrun time period may be adjusted from 5-30 minutes by altering the adjuster on the control PCB. i. To REDUCE the operating time, turn the adjuster (fig. 3.) CLOCKWISE. ii. To INCREASE the operating time, turn the adjuster (fig. 3.) ANTI-CLOCKWISE. C. WIRING. WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. This product is designed for fixed wiring installations only. Flexible cord should not be used. 1. 1mm 2 or 1.5mm 2 solid/rigid core flat cable should be used. 2. Select and follow the appropriate wiring diagram (fig. 4/5). 3. Check all connections have been made correctly and ensure all terminal connections are securely fastened. 4. Ensure the integrity of the seal between the cable outer insulation and grommet and replace in the Base Housing. THERE MUST BE NO GAPS BETWEEN THE GROMMET AND CABLE. 5. Ensure the impeller rotates and is free from obstructions. D. SERVICING AND MAINTENANCE. WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE. 1. At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits. 2. Wipe the inlets and front face with a damp cloth until clean. The fan has sealed for life bearings, which do not require lubrication.

Fig. 1. A B C D E F A B C D E F Grille Outer Bezel Cable Grommet Base Housing Shutter Assembly Quick Clip Fig. 2. Fig. 3 Base Housing Quick Clip Wall Liner Wall 1. 2. Fig. 4. Eclipse 100/150 X/XP L 1 Phase Supply (220-240 V 50 Hz) ~ N Fan L N Switched Fused Spur Pull Cord (if applicable)

Fig. 5. Eclipse 100 XT 1 Phase Supply (220-240 V 50 Hz) L ~ N Fuse Ceiling Junction Fan N L Ls 3 Pole Isolator Switch

The Guarantee Applicable only to products installed and used in the United Kingdom. For details of guarantee outside the United Kingdom contact your local supplier. Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company s option replaced, without charge, provided that the product:- Has been installed and used in accordance with the instructions given with each unit. Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is shown on the product rating label attached to the unit). Has not been subjected to misuse, neglect or damage. Has not been modified or repaired by any person not authorised by the company. IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, by post or personal visit. Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and providing evidence of date and source of purchase. The guarantee is offered to you as an extra benefit, and does not effect your legal rights Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX UK NATIONAL CALL CENTRE, Newton Road, Crawley, West Sussex, RH10 9JA SALES ENQUIRIES: Tel: 0844 8560590 Fax: 01293 565169 TECHNICAL SUPPORT: Tel: 0844 8560594 Fax: 01293 539209 For details of the warranty and returns procedure please refer to www.vent-axia.com or write to Vent-Axia Ltd, Fleming Way, Crawley, RH10 9YX 403639B 0916