Technical documentation: S1 S2 S3 S4

Similar documents
Technical documentation DTR

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

Technical documentation

Technical documentaton DTR. Farmer

Technical documentaton DTR. Farmer

Technical documentation DTR. Farmer HCF in EPP casing

Technical documentation WATER HEATED AIR CURTAIN MODELS: REVENTON GROUP AERIS 100WN-1P REVENTON GROUP AERIS 150WN-1P REVENTON GROUP AERIS 200WN-1P

HEATING AND COOLING DEVICE AGC

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

USERS MANUAL FOR GAS BOILERS

WHE 2.24 / WHE 2.24 FF

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

SAFETY AND OPERATING MANUAL

USER S GUIDE UTE202NP SERIES NON PROGRAMMABLE ELECTRONIC THERMOSTAT

1.1 VTS: number 1 in the world pillars of success

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

How to install and use your storage heater

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON ECO. PROTON ECO Three-speed AC-motor

HEATING AND COOLING UNITS BRAVA

THE QUALITY BRAND IN FANS

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

SG-WS type EXCHANGERS FOR TAP WATER HEATING ELECTRIC STORAGE TAP WATER HEATERS GUARANTEE CERTIFICATE. volume: 80, 100, 120, 140, 200, 300 and 380 dm 3

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Roof top SPACE RPC 450Z R407C M011

THE QUALITY BRAND IN FANS

Mercury RV Water Heaters. Duoetto. HCE-10 Dual Voltage 12VDC/240VAC. P.O. Box 777, Leichhardt, NSW 2040

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON AST. PROTON AST Air Heater with the anemostat

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Installation and Operating Instructions. Models: T4-12LOW-9IS

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

USER'S MANUAL PGE Single Package Rooftop

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON JET. PROTON JET Air Heater with with AirJet nozzle.

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

The guarantee on this appliance is valid for 12 months from the first day of installation.

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

PRICE LIST VALID FROM 1st October 2017

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Roof top SPACE RPC 315Z R407C MA00

Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

Click & Plug Floor Heating. Installation instruction Devidry Kit

Gas heaters and convectors ROBUR

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

Line Voltage Non- Programmable Thermostat Installation Instructions & User Guide

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

User s guide. Multiple programming Electronic thermostat

NKW. Heater series HEATERS

ST 53.1 User s manual

technical data Fan coil unit FWB small duct unit

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Air curtain SMART

DH-Direct Fired Poultry Farm Diesel Heater

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Reventon Group [Ltd.] 3B Montażowa Street, Bielsko-Biała, Poland VAT ID tel.

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Ceiling Mount Air Purification System

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Instruction FH-CWP Thermostat

LOW STATIC HYDRONIC DUCTED UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

CAW Ceiling-mounted fan heaters for hot water

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

TTV 4500 / TTV 4500 HP / TTV 7000

Air-Water heat pump Small GT

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

High temperature air-to-water heat pumps

Specification / Type INTEGRA 400/100 INTEGRA 500/120 INTEGRA 800/200

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

MULTIWASH XL OPERATOR S MANUAL & PARTS LIST PFMW18. Save These Instructions

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

INFORMATION ONLY READ AND SAVE THESE INSTRUCTIONS SAFETY FIRST

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

AQUATHERM LTD INSTALLATION AND OPERATION OF ELECTRIC BOILERS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

AXIAL FANS USER S MANUAL

Transcription:

Technical documentation: S1 S2 S3 S4 1

Table of contents: 2 1. Introduction 3 1.1 Precautions 3 1.2 Transport 3 1.3 Package content 4 1.4 Use and principle of operation 4 2. Schematic diagram 4 2.1 Construction 4 2.2 Dimensions 5 2.3 Technical data 6 3. Assembly 8 4. Installation instructions 10 5. Precautions & warnings 10 6. Connection schemes 12 7. Terms of warranty 13 8.1. Warranty card 14 8.2. Warranty form 15 8.3. Service form 16 2

1. Introduction. Thank you very much for purchasing our device. We would like to congratulate you on good choice. 1.1 Precautions. The buyer and the user of the device should read carefully the following instructions and proceed to the content recommendations. Proceeding due to the following instruction guarantees the correct usage and safety. In case of any doubts please contact the producer. The producer reserves the rights to make changes to the technical documentation without previous notice. The producer is not responsible for the damages which occur due to improper installation, not keeping the device in repair or using the device out of line. The installation should be carried out by the professional installers, who possess the qualifications to install these types of devices. The installers are responsible for making the installation as instructed in the technical data. Regulations and safety rules must be followed. During the installation, use, service and periodical inspections all regulations and safety rules must be followed. In case of unserviceable please plug out the device and contact with the authorized person or the producer. 1.2. Transport. During the acceptance of goods it is needed to check the device in order to exclude any damages. During the transport it is needed to use the proper equipment, it is necessary to carry the device by two people. In case of any damages please fill in the damage report in presence of the supplier. 3

1.3. Package content Heater Instruction and warranty card 1.4. Use and principle of operation. Devices BLOWAIR S1, S2, S3 and S4 are used to heat rooms such as : production halls, accommodation, commercial, services, garages, workshops, greenhouses, tents, shops, malls, shopping malls. Air water heater has to be connected to central heating system. Application of new technologies in Blowair devices guarantees high effectiveness and comfort of the consumption. Original colors of the devices mach to every interior. The device is made very precisely and will work smoothly for many years. The product has got the two years of warranty. 2. SCHEMATIC DIAGRAM. 2.1. Construction. Casing Air stators Heating coil Axial fan Holder Rotational holder Casing- is made of galvanizing steel, powder painting in RAL color 9005. Air stators- are made of galvanizing steel, powder painting in RAL color 7048. It is possible to set the air stators up manually to achieve the needed direction of the air flow. Heating coil- is made of aluminum and copper. The maximum temperature of the heating factor is 110 C; maximum pressure 1,6 MPa; headers diameter ¾. Depending of the size of the device we offer 1, 2 and 3 rows heating coils. Axial fan- fan casing metal, powder painting, steel wire galvanized. The motor has got the safety degree IP 54. Holder- is an additional element to assemble the device. It is solid and durable, it is possible to assemble the device on the wall or ceiling. It is also possible to regulate the angle of slope in three versions. Rotational holder- is an additional element to assemble the device. It is solid and durable, it is possible to assemble the device on the wall or ceiling. It is possible to assemble the device in parallel on the angle 60 and 45. 4

2.2 Dimensions. Drawing 1. Dimensions. Type a [mm] b [mm] c [mm] d [mm] e [mm] S1 452 494 202 350 305 S2 552 545 252 450 380 S3 552 545 252 450 380 S4 660 696 252 560 384 5

2.3 Technical data. Technical data Nominal heating capacity water 90/70 C and inlet air temperature 0 C. Unit of measure S1 S2 S3 S4 kw 16,7 29,4 52,1 59,2 Heating power range. kw 7-17 13-29 23-52 26-59 Maximum airflow. m³/h 1743 2973 2973 4400 Maximum range of air m 10-12 10-12 10-12 10-25 stream. Number of rows in heater. number 1 2 3 2 Weight including water/ without water. kg 15,5/15 22,3/21 24,9/23 29/27 Capacity of water. dm³ 0,5 1,3 1,9 2,0 Air temperature rise. * C 26,7 27,5 48,7 37,5 Maximum temperature C 110 110 110 110 of heating agent. Maximum operating pressure. MPa 1,6 1,6 1,6 1,6 Rated current. A 0,42 0,7 0,7 0,8 Power supply voltage. V/Hz 230/50 230/50 230/50 230/50 Motor power W 80 150 150 180 Motor speed. rev/min 1380 1400 1400 1380 Motor IP. - 54 54 54 54 Ferrules diameter 3/4 3/4 3/4 3/4 Temperature rise according to parameters: water 90/70 C and inlet air temperature 0 C. Technical data of Blowair S1: S1 Inlet and outlet water temperature[ C] 90/70 Heating capacity [kw] 22,2 19,4 16,7 14,2 11,7 Outlet water temperature [ C] 12,8 19,8 26,7 33,4 40,0 Water flow[m³/h] 0,98 0,85 0,74 0,62 0,52 Pressure drop in the heat exchanger [kp] 33 26 22 16 11 S1 Inlet and outlet water temperature[ C] 80/60 Heating capacity [kw] 19,6 16,9 14,3 11,8 9,40 Outlet water temperature [ C] 9,1 16,0 22,8 29,5 36,1 Water flow[m³/h] 0,86 0,74 0,63 0,52 0,41 Pressure drop in the heat exchanger [kp] 27 23 17 12 9 S1 Inlet and outlet water temperature[ C] 70/50 Heating capacity [kw] 17,1 14,4 11,9 9,44 7,09 Outlet water temperature [ C] 5,3 12,2 19,0 25,6 32,2 Water flow[m³/h] 0,75 0,63 0,52 0,41 0,31 Pressure drop in the heat exchanger [kp] 23 17 12 10 6 S1 Inlet and outlet water temperature[ C] 50/30 Heating capacity [kw] 12 9,45 7,03 4,69 2,44 Outlet water temperature [ C] -2,3 4,5 11,2 17,8 24,2 Water flow[m³/h] 0,52 0,41 0,31 0,2 0,11 Pressure drop in the heat exchanger [kp] 13 10 6 5 2 6

Technical data of Blowair S2: S2 Inlet and outlet water temperature[ C] 90/70 Heating capacity [kw] 38,8 34,0 29,4 24,9 20,7 Outlet water temperature [ C] 13,7 20,6 27,5 34,2 40,8 Water flow[m³/h] 1,71 1,5 1,29 1,1 0,91 Pressure drop in the heat exchanger [kp] 24 19 14 11 7 S2 Inlet and outlet water temperature[ C] 80/60 Heating capacity [kw] 34,5 29,8 25,3 20,9 16,8 Outlet water temperature [ C] 9,9 16,8 23,6 30,3 36,8 Water flow[m³/h] 1,52 1,31 1,11 0,92 0,74 Pressure drop in the heat exchanger [kp] 20 15 11 8 5 S2 Inlet and outlet water temperature[ C] 70/50 Heating capacity [kw] 30,2 25,6 21,1 16,9 12,8 Outlet water temperature [ C] 6,2 13,0 19,7 26,4 32,8 Water flow[m³/h] 1,32 1,12 0,92 0,74 0,56 Pressure drop in the heat exchanger [kp] 16 11 8 5 3 S2 Inlet and outlet water temperature[ C] 50/30 Heating capacity [kw] 21,4 17,0 12,8 8,7 4,71 Outlet water temperature [ C] -1,4 5,3 12,0 18,4 24,7 Water flow[m³/h] 0,93 0,74 0,55 0,38 0,2 Pressure drop in the heat exchanger [kp] 9 6 3 2 1 Technical data of Blowair S3: S3 Inlet and outlet water temperature[ C] 90/70 Heating capacity [kw] 68,9 60,3 52,1 44,3 36,8 Outlet water temperature [ C] 39,8 44,3 48,7 52,9 56,9 Water flow[m³/h] 3,04 2,66 2,29 1,95 1,62 Pressure drop in the heat exchanger [kp] 52 41 31 23 16 S3 Inlet and outlet water temperature[ C] 80/60 Heating capacity [kw] 61,5 53,0 45,0 37,4 30,1 Outlet water temperature [ C] 33,3 37,8 42,1 46,3 50,2 Water flow[m³/h] 2,7 2,33 1,98 1,64 1,32 Pressure drop in the heat exchanger [kp] 43 33 24 17 12 S3 Inlet and outlet water temperature[ C] 70/50 Heating capacity [kw] 54 45,8 37,9 30,5 23,3 Outlet water temperature [ C] 26,8 31,3 35,5 39,5 43,4 Water flow[m³/h] 2,36 2,0 1,66 1,33 1,02 Pressure drop in the heat exchanger [kp] 35 26 18 12 7 S3 Inlet and outlet water temperature[ C] 50/30 Heating capacity [kw] 38,9 31,1 23,6 16,3 9,23 Outlet water temperature [ C] 13,8 18,0 22,0 25,9 29,3 Water flow[m³/h] 1,69 1,35 1,02 0,71 0,4 Pressure drop in the heat exchanger [kp] 20 13 8 4 1 7

Technical data of Blowair S4: S4 Inlet and outlet water temperature[ C] 90/70 Heating capacity [kw] 78,6 68,7 59,3 50,3 41,7 Outlet water temperature [ C] 26,0 31,9 37,5 43,0 48,3 Water flow[m³/h] 3,46 3,03 2,61 2,22 1,84 Pressure drop in the heat exchanger [kp] 38 29 22 16 12 S4 Inlet and outlet water temperature[ C] 80/60 Heating capacity [kw] 69,9 60,2 51,0 42,2 33,8 Outlet water temperature [ C] 21,0 26,7 32,3 37,7 42,9 Water flow[m³/h] 3,07 2,64 2,24 1,85 1,48 Pressure drop in the heat exchanger [kp] 31 23 17 12 8 S4 Inlet and outlet water temperature[ C] 70/50 Heating capacity [kw] 61,1 51,7 42,7 34,1 25,8 Outlet water temperature [ C] 15,8 21,5 27,0 32,3 37,5 Water flow[m³/h] 2,67 2,26 1,87 1,49 1,13 Pressure drop in the heat exchanger [kp] 24 18 13 8 5 S4 Inlet and outlet water temperature[ C] 50/30 Heating capacity [kw] 43,4 34,4 25,8 17,6 9,50 Outlet water temperature [ C] 5,4 11,0 16,3 21,5 26,4 Water flow[m³/h] 1,88 1,49 1,12 0,76 0,41 Pressure drop in the heat exchanger [kp] 13 9 5 3 1 3. Assemblyy. All devices Blowair S1, S2, S3 and S4 can be assembled on the wall or ceiling via holder or rotational holder, which are additional elements. The drawings below show the ways of assembly. In the bigger accommodation it is recommended to assemble more than one device. Follow the parameters which are provided on the drawings. Drawing 2. Assembly on the ceiling. Drawing 3. Assembly on the wall. 8

Drawing 4. Example arrangement for few devices in the room. using the holder. Drawing 5. Three versions of the assembly position while while using the holder. Blowair devices can be assembled on the wall or ceiling via holder or rotational holder, which are additional elements. It is possible to assemble the device in parallel on the angle 60 and 45. 9

4. Installation instructions. The installation should be made by the qualified stuff, who possess the needed rights to install electrical devices, as instructed in the following documentation. To install the air waiter heater Blowair S1, S2, S3, S4 use the duct size 2 x 2,5mm². 5. Precautions & warnings. All works concerning electrical installation should be made by the qualified stuff, who possess the qualifications due to the domestic and local norms. These recommendations include service and disassembly as well. Not following to the recommendations may cause electrocution, device damages or its incorrect work. Before service or exchange of the device it is obligatory to cut off the current supply. Do not cover the inlet and outlet of the device. Do not use the device in room with high moisture or close to the water basin. Do not install, service the device with wet hands or barefoot. Do not use the device in room with inflammable fumes, gas and high concentration of dust. The device should be kept out of reach of children and animals. During the assembly use the filter on the hydraulic supply. Please use the following valves. - vent valve in the highest place on the hydraulic installation, - cut off valve on the supply and return of the device. The device should be secured against pressure increase in the water installation. Before plugging the electric supply check the leak tightness. The device does not consist of the anti-frost protection. The temperature in the room should not go below 0 C. In such case please empty the device out of water. It is recommended to check the electric installation before the first start. It is recommended to use the external current differential protection. After the turn off, the elements of device may be warm. After operating time of the device, please utilize it concerning the local norms and regulations. It is recommended to clean the device periodically: - heating coil blow through by compressed air, - fan casing and blades clean form the dirt. If the device is not used for a longer time disconnect the voltage supply. The device is transported with the closed air stators. It is essential to open them in 30 % before first start. Not keeping to the following recommendation may cause the damages of the fan. Opening the air stators must be made by two hands in parallel. Not keeping to the following recommendation may cause the damages of the air stators. 10

While plugging the device to the water installation do remember to hold its stub pipes by pipes spanner, not keeping to the recommendation may cause the damages of the heating coil. 6. Blowair automatics. To make easier the usage of the Blowair devices we also offer the additional automatics: 5-stage speed controller Blowair- is used to control the speed in single-phase fans. It consists of 5 controls 0-70 - 85-105 - 145-230V, power supply voltage-230vac / 50-60Hz, allowable current output: 1,2A; protection: thermal breaker switch; dimensions: 126mm x 176mm x 56mm; weight: 1,3 kg. It is recommended to use one speed controller to each Blowair device. Two-way valve with actuator- connection diameter ¾. It should be installed on the return (outlet) pipe. Using it, lowers the living costs. It is essential to use it with the temperature controller. After reaching the wanted temperature the valve cuts off the water inlet. Water runs in cycle and does not cool. The valve is not noisy. It is recommended to use one two-way valve with actuator to each Blowair device. Room thermostat- work environment parameters 0 C-40 C; setting range10 C-30 C; regulation accuracy 1 C; temperature number levels 1; power supply voltage 230V. It is possible to use one room thermostat to maximum 5 Blowair devices. Programmable temperature controller-saving energy up to o 30%. It is possible to regulate the temperature up and down. LCD liquid crystal display. Temperature setting every 0,2 C. It consists of 9 programmers. 3 levels of temperature- day, night, antifrozen. Work environment parameters 0 C-40 C. Setting range 5 C-30 C. Power supply 2 alkaline battery AA (1,5V). Permitted control output load 230 VAC 50Hz 5 11

(3) A. It is possible to use one programmable temperature controller to maximum 5 Blowair devices. 7. Connection schemes. 12

8. Terms of warranty. I. WTS Wysocki Tomasz 3 Montażowa Street, 43-300 Bielsko- Biała, Poland, is the producer of the Blowair brand. The warranty concerns the following devices and it is valid for 2 years: - air heater S1, - air heater S2, - air heater S3, - air heater S4. II. Warranty is valid in European Union. III. The terms of warranty are valid from purchasing the device (the date issuing a document confirming the purchase of the device) but not further than 30 months from leaving the Blowair s warehouse. IV. The defects revealed during the warranty period will be removed free of charge in 14 working days. The service will be done by the installation company due to the terms of warranty included in warranty card. The elements will be supplied by the Blowair producer during the warranty period. V. Warranty does not cover the parts of the device subject to normal maintenance and the cases as below: a) Mechanical defects, damages from the impact of the improper transportation or damages through improper storage. b) Defects through: - improper usage and service, - using the device in the improper conditions (too high humidity, too high or too low temperature, impact of the surrounding, sun ect., - modified equipment that has been modified or repaired without written agreement of the producer; - connecting additional equipment, which is not recommended by the producer or inconsistent with the technical documentation, - improper power supply. c) Elements which wear and tear such as discolor or using. VI. All changes in record in the warranty terms or any constructive modifications, independent service outside the Blowair service or use, uncaring, makes the warranty not valid. VII. To obtain the service it is needed to send to the producer warranty card with the signature, document confirming the purchase, (copy of the invoice) and correctly filled the warranty form. VIII. Not following to any of warranty regulations makes the warranty not valid. IX. All correspondence, returns, complains should be send to the following address: Blowair WTS Wysocki Tomasz 3 Montażowa Street, 43-300 Bielsko-Biała or e-mail: serwis@blowair.pl The producer reserves the rights to make changes to the technical documentation without previous notice. 13

8.1. Warranty card. WTS Wysocki Tomasz 3 Montażowa Street 43-300 Bielsko-Biała Poland Stamp and signature of the installation company: Factory number of the device: Address and place of assembly. City: Postal code: Street: Number: Place: 14

8.2. Warranty form. The company reporting the complaint: The company installing the device. Factory number of the device. Date of assembly: Date and circumstances of noticing the defect: Date of declaration the complaint: Address and place of assembly the device: Contact Name and Surname: Telephone number/ e-mail address: Description of the defect: 15

8.3 Service card. Lp. Date of declaration the complaint Date of repair Description of the repair Service stamp 16

WTS Wysocki Tomasz 3 Montażowa Street, 43-300 Bielsko-Biała Poland Mobile +48 791 40 40 40; +48 792 40 40 40; +48 793 40 40 40; Fax. +48 33 444 61 04 17