NGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions

Similar documents
NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

RAYCHEM NGC-30 COMPONENTS

910 Series Single-point heat-tracing control system

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Sensor Interface Module Installation/Operation Instructions

Dual-point heat-tracing control system

DESCRIPTION. 42 mm. 125 mm

ACCS-30. Multipoint commercial heat-tracing control system

NGC-40 Advanced Heat-Tracing Control System

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

HTC-915-CONT. Heat-Trace Control system

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

THERMAL MANAGEMENT SOLUTIONS

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

THERMAL MANAGEMENT SOLUTIONS

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

Supervisor Standard Edition

Longline Heating. Contents. Introduction

For Raychem ACS-30 Controls Systems

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

NGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions

1SC-SSC Splice Connection Kit Installation Instructions

FreezGard. Self-regulating crankcase heater. Product Overview

C910 Series. Single-point heat-tracing control system

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

NGC-20-C-E and NGC-20-CL-E

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

21-light Remote Annunciator. Owner s Manual

Factory and Field Installed Splices

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

Colibri. Automatic Tank Gauge CL6 Series Installation Guide

NGC-20-C-E and NGC-20-CL-E

Modular Sensing Cable Installation Instructions

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

aquilar - leak detection solutions

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

FTC-HST WARNING: CAUTION:

sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System

fuel leak detection find leaks before they find you

ACS-30-EU-VIA-DU-20-MOD

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

TT3000 and TT5000 Series

Skin-Effect Heat-Tracing System (STS)

INSTALLATION INSTRUCTIONS

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

aquilar - leak detection solutions

Frost Heave Protection System Installation and Operation Manual

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

C Heat Trace Controller

INSTALLATION INSTRUCTIONS

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

TT3000 and TT5000 Series

frost heave prevention

SAFETY INFORMATION AND WARNINGS

KT-100 Door Controller

Supervisor OPERATIONS MANUAL. Heat-Tracing Controller Configuration and Monitoring Software. Versions up to 2.7xx. INSTALL-118 (Europe)

UNC100 Integra Manual

NGC-20-C-E and NGC-20-CL-E

DMFPM-2R MULTIFUNCTIONAL

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

DigiTrace T2000 Heat Trace Controller

APPLICATION DATA SHEET

Sensepoint XCL Fixed Gas Detector

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

WebAlert WA500 Series Process Monitor Instruction Manual

M2500 Engine Controller Installation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

TTSIM-1 Sensor Interface Module

nugate Product Catalog

NGC-20 LOCAL CONTROL CENTRAL MONITORING

IMPORTANT INSTRUCTIONS READ & SAVE

ACS-30-EU-EMDR- 10-MOD

Alarm Panel Operating Instructions

Dräger VVP 1000 System Components

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

APPLICATION DATA SHEET

Transcription:

NG-UIT2-ORD-R Remote User Interface Terminal for Raychem NG Systems Installation Instructions Description The NG-UIT2-ORD-R is a wall-mounted display which allows the User Interface Terminal (UIT) to be installed remotely. The NG-UIT2-ORD-R is used with Raychem NG series control and monitoring systems. The NG-UIT2-ORD-R is rated IP 65 (Type 4), and is approved for nonhazardous indoor and outdoor locations. These instructions describe how to mount the NG-UIT2-ORD-R on a wall and how to make connections to the User Interface Terminal and are intended for a qualified electrician. Tools Required Drill or hole punch for electrical conduit entries Phillips (cross-head) screwdriver Small flat-head screwdriver Additional Materials Wall fasteners for surface mounting (four screws) cable (Belden # 8761 or arol # 2514) Kit ontents Qty Description 1 NG-UIT2-ORD display 4 Elastomeric washers 1 5-ft 9-pin RS-232 (Null Modem) cable Approvals / ertifications Nonhazardous Locations LR67275 General Area of use Supply voltage Nonhazardous, Indoors and outdoors (IP65, Type 4) 100 240 Vac ±10%, 50/60 Hz Operating temperature 25 to 60 ( 13 F to 140 F) Storage temperature 25 to 80 ( 13 F to 176 F) Dimensions Alarm Outputs Relay outputs LD Display Display Touch screen 386 mm W X 336 mm H X 180 mm D (15.21 in. W X 13.21 in. H X 7.09 in. D) Three form relays rated at 12 A @ 250 Vac. One relay used for common alarm light. Relays may be assigned for alarm outputs. LD is a 8.4 inch XGA, color TFT transflective device with integral LED backlight 5-wire resistive touch screen interface for user entry. Network onnection Local/Remote Port RS-232/ ports (, 2-wire isolated) may be used to communicate with host computers (Raychem Supervisor Software) or DS Local RS-232 A non-isolated, 9 pin D sub male Remote #2 10 pin terminal block, 0.2 mm to 2.5 mm 2 (24 12 AWG) wire size Data rate 9600 to 57600 baud Maximum cable length Field Port For not to exceed 1200 m (4000 ft). able to be shielded twisted pair., 2-wire isolated. Used to communicate with external devices, such as NG-40-RM and RMM2. Maximum cable length not to exceed 1200 m (4000 ft). able to be shielded twisted pair. Field #1 10 pin terminal block, 0.2 mm to 2.5 mm 2 (24 12 AWG) wire size Data rate To 9600 baud LAN 10/100 Base-T Ethernet port with Link and Activity Status LEDs USB Ports USB 2.0 Host port Type A receptacle (X2) WARNING: FIRE Hazard: The NG-UIT2-ORD-R must not be used in hazardous locations. Electrical components within the unit could ignite flammable gases. Do not install the unit where it may be exposed to flammable gases. IMPORTANT: The NG-UIT2-ORD-R is an electronic device. During installation, take the following precautions to avoid damage to its electronic components. Handle with care to avoid mechanical damage. Keep electronics dry. Avoid exposure to static electricity. Avoid contamination with metal filings, liquids, or other foreign matter. Take care to protect the user interface board on the enclosure door. Use agency-approved conduit bushings, adapters, and cable glands to keep the enclosure protected from dust and fluids. 1 / 6

Mounting the Enclosure The Raychem NG-UIT2-ORD-R controller must be mounted in a nonhazardous indoor or outdoor location. hoose a location indoors or outdoors where the controller will be protected from the elements and kept above 25 ( 13 F) and below 70 (158 F). Install the enclosure using the four screws (not provided) in the 7.92 mm (0.31 in) mounting holes with centers as shown below. 386.4 mm (15.21 in) 335.6 mm (13.21 in) 367.3 mm (14.46 in) 348.3 mm (13.71 in) Electrical Safety Follow electrical safety procedures when installing and maintaining the NG-UIT2-ORD-R unit, as line voltage is present inside. Back side of UIT Incoming Power Supply Power 1 2 3 Alarm Relays Field Remote Ports 2 / 6

onnecting Main Power onnecting Field Port ommunication Use only copper conductors for field wiring. A close-up of the power connection terminals is shown below. This connection energizes the Raychem TOUH 1500 electronics only; it does not provide power to the heat tracing or contactor coils. Note: If the Raychem TOUH 1500R controller has a different source of power than the heat tracing, it may be worthwhile to install an uninterruptible power supply (UPS) so the unit can continue to control and/or monitor the heat tracing in the event of a localized power failure. The NG-30-RM/S, RMM2 and NG-20 communicate with the NG UIT2 ORD R over an network, which may have a total cable length of 1200 m (4000 ft). The communicating cable shall be a shielded, two conductor (twisted pair) cable. To downstream devices (NG-30-RM/S, RMM2 & NG-20). Refer to As Built drawings for connection details. For cable type, reference Belden #8761 or arol #2514. Ø or N Ø G 100 240 Vac ±10% -2-1 To Remote Port cable to -1 on UIT (preconnected) Refer to the NG-30 Programming Manual (H58186; INSTALL-111) and the NG-30 Installation Manual (H58585; INSTALL-113) for further details. onnecting, RS-232 and Ethernet Remote Port ommunication (optional) These ports are used to communicate to a host computer or DS and are user selectable for either, RS-232 or Ethernet. If the RS-232 port is utilized, the supplied female to female, 9-pin null modem adaptor cable must be used. Optional connection To DS or P Optional RS-232 onnection Alarm Light and Optional Alarm Relays Relay 1 on the NG-UIT2-ORD-R is factory-configured and wired for Any Alarms. It will energize a push to test light on the front of the panel if any alarm occurs. The NG-UIT2 has two other Form alarm relays (Relays 2 and 3, configurable through the NG-UIT2 program) for external alarms. Each relay can be connected to an annunciator light or distributed control system. To Alarm Light N N Relay 2 N Relay 3 RS-232-2 -1 Ethernet cable to -2 on UIT (preconnected) -1 onnection Optional Ethernet onnection 1 2 3 Alarm Relays Note: The above relays are shown in the energized position without an alarm condition. The relay will change state with an alarm condition or loss of power. 3 / 6

NG-UIT2-ORD-R onnection Diagram Front view Open ollector Outputs USB device port AN USB -2-1 Debug Port Ethernet -1 Power Bottom view RS-232-2 Side view Side view Back view 4 / 6

Overview of Wiring Ø or N 100-240 Vac Ø ±10% G Incoming Power Power Supply To Alarm Light N N To downstream devices (NG-30-RM, RMM2, NG-20, RM) To P 1 2 3 Alarm Light and Optional Alarm Relays Field Port Remote Port Servicing The NG-UIT2-ORD contains no user-serviceable parts. ontact your Pentair Industrial Heat Tracing Solutions representative for service and an authorization number if required. leaning The touch screen area of the NG-UIT2-ORD may be cleaned with a damp or dry cloth. Typical window cleaning agents may be applied to aid in the removal of dirt, dust and grease. Do not use abrasive cleaners. 5 / 6

configuration switches The configuration switches are found on the right side of the NG-UIT2-ORD. Refer to the table below for settings. 3 2 1-1 -2 ON Pull-down Pull-up Position Switch On Off omments Pull-down (As-shipped default) network signal is forced to a determinate state when idle. network signal is not forced to a determinate state when idle. One device (typically this NG-UIT2-ORD) on the network should force the network - signal to a determinate state. Pull-up (As-shipped default) network + signal is forced to a determinate state when idle. (As-shipped default) network is terminated with 120-ohm resistor. network + signal is not forced to a determinate state when idle. network is not terminated. One device (typically this NG-UIT2-ORD) on the network should force the network + signal to a determinate state. Terminate the device (NG-UIT2-ORD or other) that is at each end of the network, for a total of two terminated devices. No other devices on the network should be terminated. Reset switch The Reset switch can be found on the side of the NG-UIT2-ORD. A pointed object is required to press the reset switch and restart the NG-UIT software. Reset WWW.PENTAIRTHERMAL.OM RTH AMERIA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 thermal.info@pentair.com Europe, Middle East, Africa Tel: +32.16.213.511 Fax: +32.16.213.603 thermal.info@pentair.com Asia Pacific Tel: +86.21.2412.1688 Fax: +86.21.5426.2937 cn.thermal.info@pentair.com Latin America Tel: +1.713.868.4800 Fax: +1.713.868.2333 thermal.info@pentair.com Pentair and NG are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. 2010-2015 Pentair. 6 / 6