MCR & MCR SERIES Roll-in & Pass-Thru Blast Chillers

Similar documents
MASTER-CHILL ROLL-IN & PASS-THRU BLAST CHILLERS/FREEZERS

BLAST CHILLERS & BLAST CHILLER/FREEZERS

roof finish is 26 gauge acrylic coated stucco galvanized steel.080 textured aluminum interior floor finish, where required

10-Bilt. Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS

Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations. KaTom Restaurant Supply, Inc.

The Endura Series. The right combination of versatility, efficiency and reliability in foodservice equipment.

The Endura Series. Options. The right combination of versatility, efficiency and reliability in foodservice equipment.

Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations

QUICK SHIP Walk-In Coolers & Freezers With Matching Refrigeration Systems SEE INSIDE

BLOOD PLASMA Walk-in Freezers

A Complete Line Of Remote Rack Refrigeration Systems

Glass Doors, Hinged Bottom Mounts

PS & GPS SERIES PARALLEL RACK REFRIGERATION SYSTEMS

VertiCool Aurora Engineering Guide

Vaccine & Pharmacy Upright Glass Door Refrigerators

CoolSpot Engineering Guide

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

Cabinet & Merchandiser Price List

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Reach In Refrigerators Bottom Mount

Cabinet & Merchandiser Price List

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

C13-Series Engineering Guide

Why use Blast Chiller or Freezer?

MAC N-407 Air-Cooled Chiller

BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

MACH N-407 Heat Pump Air-Cooled Chiller

Upright Chromatography Refrigerators

FOGEL Caribbean Corporation

Call us today! (800)

horizontal air discharge outdoor discus condensing unit

Call us today! (800)

Preparation Table Raised Condiment Rail models 8000N

START-UP TRAINING AND INSTRUCTIONS HURRICHILL BLAST CHILLERS

NOVA Products. Quality Refrigeration Since Reach-in, Roll-in & Pass-Thru Cabinets. Heated Cabinets. Blast Chillers. Blast Chillers/ Freezers

Call us today! (800)

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

VariCool VAV Engineering Guide

Refrigeration Contents

system support/ trayline equipment

INNOVATIVE DESIGNS FOR YOUR FOODSERVICE NEEDS BASE MODELS WORKTOPS, UNDERCOUNTERS & SANDWICH UNITS

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers

Self-Contained MERCHANDISERS. February

TB SERIES. Glycol Pizza/Salad/Sandwich Prep Tables Self-Contained. Project Quantity Item # Model Specified: CSI Section 11400

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

Canning Shed/Facility Equipment Specifications

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

General Features. 01. CoolSmart Controller Professional Refrigeration Upright Cabinet Series

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Installation Manual BCS2000/3000

Benefit Cabinets. Performance. Efficiency

Benefit Cabinets. Performance. Efficiency

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

"N-Width" Reach-In Refrigerator-Freezer Models/Self-Contained. Project Quantity Item # Model Specified: CSI Section 11400

Air-Cooled Condensing Units with Compact Screw Compressors

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Global. Refrigeration, INC. QUALITY REFRIGERATION PRODUCTS Grant Avenue, Cleveland, OH

Blast Chiller and Shock Freezer Systems

MAC-120HE-03 Air-Cooled Chiller

Installation Manual BCS 1000/1500

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

Self-Contained MERCHANDISERS. October

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Kramersaver Air Cooled Condensing Units

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

BLU Series Prep Tables. BLU Series Prep Tables. Models ITEM #

50TM COMBINATION HEATING/COOLING UNITS

Precise Temperature Control; Compact Footprint

REFRIGERATION PRODUCTS

USA FOOD SERVICE EQUIPMENT PRICE LIST

LOW PROFILE UNIT COOLER

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

INSTALLATION and OPERATION INSTRUCTIONS

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

NEW CHILLER SCHEDULE

DES MOINES PUBLIC SCHOOLS MADISON WALK-IN COOLER/FREEZER PROJECT. 806 E. Hoffman Street Des Moines, IA ADDENDUM NO.

3 Year Parts/Labor Warranty Additional 2 Year Compressor Warranty

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Indoor Air Handlers with Compressors MVS and MVW

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

GIRTON CABINET WASHER MODEL 794A

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

A QUICK GUIDE to our COMPLETE LINE of QUALITY REFRIGERATION PRODUCTS

Undercounter Units. 20 Call or Text for pricing on True and other great brands! UNDERCOUNTERS & WORKTOPS (19 24) REFRIGERATION

LOW PROFILE UNIT COOLER

Gas and Electric Convection Ovens

INSTALLATION and OPERATION INSTRUCTIONS

Transcription:

ITEM NO. PROJECT LOCATION DATE QTY. MCR-33-101 FEATURES Full-length evaporator coil and vertical fan tower provide evenly distributed cooling. MCR-33-101 & MCR-33-102 SERIES Roll-in & Pass-Thru Blast Chillers ROLL-IN MODELS MCR-33-101 MCR-33-102 PASS-THRU MODELS MCR-33-101PT MCR-33-102PT CONSTRUCTION Stainless steel interior and exterior with polyurethane foamed-in-place insulation Interior light Door gasket heater High velocity forced air convection through evaporator coil HACCP compliant recording thermometer for blast chiller ambient air temperature (requires printer to have record) 4 food temperature probes with sequential readout display in MCR-33-101, 8 probes in MCR-33-102 Automatic chill cycle control with food temperature probes DOORS Door dimensions: 30" x 78" Flush mounted 36" high 16 ga. stainless steel kickplate on door exterior REFRIGERATION SYSTEM An air- or water-cooled condensing unit will be supplied depending on application. CONTROL PANEL HACCP compliant recording features Surface mounted on exterior of blast chiller On/off switch Digital readout of interior ambient temperature Digital cycle timer Microprocessor control system enclosed in easily accessible box Automatic air defrost cycle Automatic hold cycle Audible alarm at end of chilling cycle RACK Racks provided: MCR-33-101... 1 MCR-33-102... 2 Stainless steel construction Accomodates 26 pans, 12" x 20" x 2 1 /2", two per each of 13 ledges Ledges on 4 1 /2" spacing Each pan holds up to 10 pounds of food for total rack quantity of 260 lbs. Rack dimensions: 24 1 /2" wide x 27" deep x 68 5 /16" high Rack mounted on heavy-duty swivel casters COOLING TIME Maximum load of 260 pounds of food requires approximately 90 minutes per cooling cycle depending on food density and input temperature of food WARRANTY Standard limited one year extended compressor (optional four year extended warranty available), one year limited parts, limited 10 year panel warranty OPTIONS Optional finishes Add suffix C for correctional model Printer package Extended four year compressor warranty 908 Highway 15 North New Albany, MS 38652 PHONE: 800-647-1284 or 662-534-9061 FAX: 800-232-3966 or 662-534-6049 www.master-bilt.com

MASTER-CHILL MCR-33-101 & MCR-33-102 SERIES ROLL-IN & PASS-THRU BLAST CHILLERS BLAST CHILLER TECHNICAL SPECIFICATIONS (in inches) (in millimeters) MAX. MODEL L D* H* L D* H* VOLTS MCA FUSE SHIP WT. LB/KG ROLL-IN MCR-33-101 70 52 89 1778 1194 2184 208-230/1ph/4-wire 9 15 1500/682 MCR-33-102 70 98 89 1778 2362 2184 208-230/1ph/4-wire 16 20 3000/1364 PASS-THRU MCR-33-101PT 70 52 89 1778 1194 2184 208-230/1ph/4-wire 9 15 1500/682 MCR-33-102PT 70 98 89 1778 2362 2184 208-230/1ph/4-wire 16 20 3000/1364 *Depth and height include control panel. MCR-33-101 PLAN VIEW MCR-33-101 ELEVATION VIEW MCR-33-101 SIDE VIEW MCR-33-102 PLAN VIEW MCR-33-102 ELEVATION VIEW MCR-33-102 SIDE VIEW LISTINGS HOOKUP Hardwire, remote refrigeration. 2

REFRIGERATION SYSTEM TECHNICAL SPECIFICATIONS All condensing units must include a suction accumulator. Pull down time reflects time necessary to lower listed quantity of food from 140 F to 40 F. All units listed contain R-404A refrigerant. COND. UNIT MODEL* BTUH @ -10 F SUCTION TEMP.** UNIT CONNECTION SIZES SEE DRAWING... (PP. 4-5) RECEIVER PUMPDOWN CAP. @ 90% SHIP WT. (LB/KG) MCA** MOP** RLA** LRA** H.P. LIQUID SUCTION MCR-33-101, 200 LB. CAPACITY, 2 HOUR PULL DOWN TIME MSLZ0101C 3 10,653 3/8 7/8 M2 11.4 200/91 20 30 11.1 77 MHLZ0121B 3 11,559 1/2 1 1 /8 M2 11.4 260/118 30 45 19 105 MCLZ0111B 3 10,372 1/2 7/8 M2 11.4 330/150 24 35 14.7 86 MCLZ0111C 3 10,343 1/2 7/8 M2 11.4 330/150 19 25 10 82 MCR-33-101, 200 LB. CAPACITY, 1.5 HOUR PULL DOWN TIME MSLZ0151C 4 14,994 1/2 7/8 M2 11.4 230/105 32 40 15 99 BSLZ0400B 4 15,047 1/2 7/8 C 41.5 510/232 42 60 26.8 129 BSLZ0400C 4 15,047 1/2 7/8 C 41.5 510/232 32 40 15 99 BSLZ0400E 4 15,047 1/2 7/8 C 41.5 510/232 20 20 8.2 49.5 BCLZ0280B 3 15,529 5/8 1 1 /8 C 41.5 505/230 32 40 15 105 BCLZ0280C 3 15,529 5/8 1 1 /8 C 41.5 505/230 32 35 12.6 112 BCLZ0280E 3 15,529 5/8 1 1 /8 C 41.5 505/230 20 20 6.2 56 MCR-33-101, 250 LB. CAPACITY, 2 HOUR PULL DOWN TIME MSLZ0151C 4 14,994 1/2 7/8 M2 11.4 230/105 32 40 15 99 MCLZ0141B 3 13799 1/2 1 1 /8 M3 11.4 500/227 28 40 16.7 105 MCLZ0141C 3 13903 1/2 1 1 /8 M3 11.4 500/227 26 35 12.8 112 BSLZ0400B 4 15,047 1/2 7/8 C 41.5 510/232 42 60 26.8 129 BSLZ0400C 4 15,047 1/2 7/8 C 41.5 510/232 32 40 15 99 BSLZ0400E 4 15,047 1/2 7/8 C 41.5 510/232 20 20 8.2 49.5 BCLZ0280B 3 15,529 5/8 1 1 /8 C 41.5 505/230 32 40 15 105 BCLZ0280C 3 15,529 5/8 1 1 /8 C 41.5 505/230 32 35 12.6 112 BCLZ0280E 3 15,529 5/8 1 1 /8 C 41.5 505/230 20 20 6.2 56 MCR-33-101, 250 LB. CAPACITY, 1.5 HOUR PULL DOWN TIME MSLZ0181C 5 18,945 1/2 1 1 /8 M3 15.2 240/109 36 55 21.4 123 MDLZ0201C 3 19,518 1/2 1 1 /8 M5 15.2 530/241 38 45 16.8 102 MCR-33-101, 250 LB. CAPACITY, 1.3 HOUR PULL DOWN TIME BSLZ0600C 6 21,651 1/2 7/8 C 41.5 550/250 41 60 23.9 156 BCLZ0400C 4 21,531 5/8 1 3 /8 C 41.5 530/230 44 60 26.3 161 BCLZ0400E 4 21,531 5/8 1 3 /8 C 41.5 530/230 22 30 10.2 60 BSLZ0600E 6 21,651 1/2 7/8 C 41.5 550/250 21 25 9.3 70 MCR-33-101 250 LB. CAPACITY, LESS THAN 1 HOUR PULL DOWN TIME BCLZ0750C 7 1 /2 37,322 7/8 1 3 /8 D 53.4 730/332 55 80 31.5 161 BCLZ075UE 7 1 /2 37,322 7/8 1 3 /8 D 53.4 730/332 32 40 16.1 83 MCR-33-101 250 LB. CAPACITY, LESS THAN 1 HOUR PULL DOWN TIME WATER COOLED CONDENSING UNITS SCLZ075WC 7 1 /2 39,600 5/8 1 3 /8 D 78.4 730/332 50 80 31.5 161 SCLZ075WE 7 1 /2 39,600 5/8 1 3 /8 D 78.4 750/341 32 40 16.1 83 MCR-33-102, 400 LB. CAPACITY, 2 HOUR PULL DOWN TIME MSLZ0221C 6 23,018 1/2 1 1 /8 M5 22.1 250/114 39 60 23.9 156 MDLZ0231C 4 22,958 1/2 1 1 /8 M5 15.2 530/241 42 60 26.3 161 BCLZ040LC 4 23,171 5/8 1 3 /8 C 41.5 530/241 45 70 26.3 161 MCR-33-102, 400 LB. CAPACITY, 1.5 HOUR PULL DOWN TIME MDLZ0291C 6 29,187 5/8 1 3 /8 M5 22.1 560/255 47 70 28.2 161 MCR-33-102, 500 LB. CAPACITY, 2 HOUR PULL DOWN TIME MDLZ0291C 6 29,187 5/8 1 3 /8 M5 22.1 560/255 47 70 28.2 161 BSLZ0750C 7 1 /2 26,006 7/8 1 3 /8 D 53.4 600/272 45 60 23.4 189 BCLZ0600C 6 26,466 5/8 1 3 /8 C 41.5 560/255 46 70 28.2 161 BCLZ0600E 6 26,466 5/8 1 3 /8 C 41.5 560/255 26 35 13.3 80 *VOLTAGE KEY: B suffix = 208-230 or 230 volt, 60 cycle, one phase C suffix = 200-230 or 208-230 volt, 60 cycle, three phase E" suffix = 460 volt, 60 cycle, three phase **Based on 90 F ambient ***Electrical ratings for condensing unit only. See National Electrical Code if units are combined on a single circuit.

REFRIGERATION SYSTEM TECHNICAL SPECIFICATIONS COND. UNIT MODEL* BTUH @ -10 F SUCTION TEMP.** UNIT CONNECTION SIZES SEE DRAWING... (PP. 4-5) RECEIVER PUMP- DOWN CAP. @ 90% SHIP WT. (LB/KG) MCA** MOP** RLA** LRA** H.P. LIQUID SUCTION MCR-33-102, 500 LB. CAPACITY, 1.5 HOUR PULL DOWN TIME MDLZ0331C 6 32,417 5/8 1 3 /8 M5 22.1 560/255 50 70 30.3 150 BCLZ0750C 7 1 /2 37,322 7/8 1 3 /8 D 53.4 730/332 55 80 31.5 161 BCLZ0750E 7 1 /2 36,200 7/8 1 3 /8 D 53.4 730/332 32 40 16.1 83 MCR-33-102, 500 LB. CAPACITY, LESS THAN 1 HOUR PULL DOWN TIME BCLZ1500C 15 70,782 7/8 1 5 /8 F 116.1 990/450 90 125 52.6 278 BCLZ1500E 15 70,782 7/8 1 5 /8 F 116.1 990/450 51 70 26.3 139 MCR-33-102, 500 LB. CAPACITY, LESS THAN 1 HOUR PULL DOWN TIME WATER-COOLED CONDENSING UNITS SCLZ100WC 10 54,800 7/8 1 3 /8 E 105.3 743/338 66 100 42 215 SCLZ100WE 10 54,800 7/8 1 3 /8 E 105.3 910/414 34 50 18.6 106 *VOLTAGE KEY: B suffix = 208-230 or 230 volt, 60 cycle, one phase C suffix = 200-230 or 208-230 volt, 60 cycle, three phase E" suffix = 460 volt, 60 cycle, three phase **Based on 90 F ambient ***Electrical ratings for condensing unit only. See National Electrical Code if units are combined on a single circuit. BASE C BASE D BASE E 4

MASTER-CHILL MCR-33-101 & MCR-33-102 SERIES ROLL-IN & PASS-THRU BLAST CHILLERS REFRIGERATION SYSTEM TECHNICAL SPECIFICATIONS (cont.) BASE F BASE M2 BASE M3 BASE M5 5

BID SPECIFICATIONS Item no. MCR-33- Provide ( ) Roll-in or Pass-thru Blast Chiller(s) Master-Bilt model number MCR-33-. Blast chiller to be provided with stainless steel construction and polyurethane foamed-in-place insulation. Blast chiller will feature high velocity forced air convection through evaporator coil. Probes with sequential readout display will be supplied for food temperature recording (four probes in MCR-33-101 model, eight in MCR-33-102). An automatic chill cycle control with food temperature probes is also supplied. A thermometer will be provided for recording blast chiller ambient air temperature. Thermometer will require optional printer for record of temperatures. Roll-in blast chillers will contain one 30 x 78 flush mount- ed, polyurethane foamed door. Pass-thru models will contain two doors. Doors will be provided with a 36 high 16 ga. stainless steel kickplate on the exterior. Doors will also be supplied with a hold-open feature, magnetic gaskets and gasket heater. Blast chillers will be provided with an air- or water-cooled condensing unit depending on application requirements. Blast chiller will be equipped with a standard exterior mounted control panel featuring the following: On/off switch Digital readout of interior ambient temperature and probe temperatures Digital cycle timer for timed chilling Microprocessor control system enclosed in easily accessible box Automatic defrost cycle and hold cycle Audible alarm at end of chilling cycle Six programmable one-touch preset chilling programs for easy use Blast chillers will be supplied with stainless steel racks (one rack for MCR-33-101/33-101PT, two for MCR-33-102/33-102PT) mounted on heavy-duty swivel casters. Racks accommodate 26 pans, 12 x 20 x 2 1 /2, two per each of 13 ledges. Each pan holds up to 10 lbs. of food for total rack quantity of 260 lbs. Dimensions of rack are 24 1 /2 wide x 27 deep x 68 5 /16 high. Blast chillers to have standard limited one year extended compressor warranty (optional four year extended warranty available) with one year limited parts and limited 10 year for panels. Blast chillers will be UL and C-UL listed and UL EPH classified. NOTE: All specifications subject to change without notice. 908 Highway 15 North New Albany, MS 38652 PHONE: 800-647-1284 or 662-534-9061 FAX: 800-232-3966 or 662-534-6049 www.master-bilt.com 1287-3/14-web 2014 Master-Bilt Products, an unincorporated division of Standex International Corporation. All rights reserved. Printed in U.S.A.