SERVICE BULLETIN Carrier Corporation 2014

Similar documents
DEALER SERVICE BULLETIN

Installation Instructions

Installation Instructions

Installation Instructions

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

Operating Letter. Operating Letter #730 January 1, 2014 WARRANTY AND TECHNICAL SERVICE

ELX -GN Instructions. Electrolux Front Load Washing Machine Class Action Settlement Claim Form Instructions GENERIC CLAIM FORM

CARRIER GAS FURNACE INSTALLATION MANUAL

Jefferson Cocke County Utility District Marketing Plan (July 1, 2008 through June 30, 2019) Revised effective July 01, 2016 A) Identify commercial

Water Heater Innovations Marathon Water Heater Limited Warranty Policies & Procedures

M1200 Series Limited Warranty Dependability Promise

7.0 Applying Basic Electricity Principles to Service Propane Appliances Skill Evaluation Packet (Updated 11/2012)

Warranty Manual. Espar Products, Inc. Tel: Fax: QSF-60 Rev. 7

Preventative Maintenance Plan Information PO Box 507 Located at 1009 N. 20 th St. Morehead City, NC Phone: (252) Fax: (252)

Technical Bulletin. Brand Maytag Jenn-Air. Date: June Policy Letter Service Information. No: TDD-0011B-B Page 1 of 6 Supersedes: TDD-0011A-B

RESIDENTIAL REBATE FORM

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

ALABAMA Propane Gas Association

Electrolux Reseller FAQs

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

Application for Certification for an Alarm System Contractor

GAS FURNACE USER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE

RINNAI PROPANE-FIRED PRODUCTS PROMOTION $100. On Rinnai Water Heating & Home Heating Products

USER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE

Multi-Position Gas Furnaces

NFPA Fire Inspector I Study Guide

ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977

Installation & Operation Manual Ice Cream Freezers

FILE - CARRIER FURNACE INSTALLATION MANUAL DOWNLOAD

2011 NATURAL GAS EFFICIENCY REBATE APPLICATION

Ruud Achiever Plus Series Multi-position Gas Furnaces

Residential Rebate Program Available to NYSEG and RG&E residential natural gas and electric customers.

USER'S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW GAS-FIRED FURNACE

Service Parts, Kits and Accessories

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS

Department of Public Safety

TECHNICAL SPECIFICATIONS

HOT DOG STEAMER Instruction Manual Models: 8007 & 8012

Application Information

Guidelines for the Sanitary Sewer Evaluation Survey (SSES) Report PLAN A

American Standard Furnace Error Codes 4 Flashes

CITY OF LOS BANOS LANDSCAPE PLAN REVIEW PROCEDURE. Public Works Department 411 Madison Avenue, Los Banos, CA FOR ALL PROJECTS:

Part No Revised January 30, 2007 SAFETY PRECAUTIONS

FOR EASY, FAST INSTALLATION AND FOR RESULTS

MIGHTY PRO 1/4 HP CHILLER

IMPORTANT SAFETY RECALL

SBEC Residential Energy Efficiency Rebate Programs for New Homes

REQUEST FOR PROPOSALS CLEANING SERVICES

SECTION TESTING OF FIBER OPTIC CABLES

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

UPPER FUSING HEAT ROLLER REPLACEMENT

Ruud Achiever Series Multi position Gas Furnaces

Is a heating protection plan really worth it? Decide for yourself!

Rheem Classic Plus Series Multi position Gas Furnaces

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Part No Revised November 2004 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5513

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

In accordance with the Department of Labor and Industry s statute , Subd. 11,

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

Flat Rate Pricing. Regular Primary BELT30 ALL BLOWER BELTS $ $ $ /4 TO 1/5120V RESCUE MOTOR $ $ $309.

2017 WOOD BURNING DEVICE CHANGE-OUT PROGRAM GUIDELINES*

DATE: CHECK AMOUNT: CHECK NUMBER: RENEWAL APPLICATION. COMPANY CERTIFICATE OF REGISTRATION And INDIVIDUAL LICENSE RENEWAL

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

Comfort, Quality and Efficiency.

MULTI POSITION GAS FURNACE

Central Air Conditioning System

2003 Saturn ION. Some customers may comment on moisture leaking onto the floor of the vehicle when the A/C system is running.

Full Service Central Station Fire Alarm Listing Evaluation

winholt equipment Operational Maintenance & Service Bulletin for Models: NHPL-1836C NHPL-1825-UNC fax

Alert Service Bulletin

SBEC Residential Energy Efficiency 2019 Rebate Programs for Existing Homes

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

ALABAMA THE UNIVERSITY OF ALABAMA SURPLUS PROPERTY SALE PS /17/15. Website:

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

2015 NATURAL GAS EFFICIENCY REBATE APPLICATION

USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Please Read Carefully

Preliminary Operations and Maintenance Plan Baron Winds Project

Rheem Classic Series Multi-position Gas Furnaces

ENGROSSED SUBSTITUTE HOUSE BILL State of Washington 60th Legislature 2007 Regular Session

Gas Equipment. Volume 3 April Issue date: April 29, 2009

Orange County Fire Rescue Department Office of the Fire Marshal 7079 University Blvd. Winter Park, FL Phone: Fax:

Residential rebate application instructions

PRIVATE ALARM CONTRACTOR LICENSURE EXAMINATION INFORMATION


OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

Fuel Oil Heating Installation Inspection Report #1 2008

E-Z Zone Pack 3+1 And 5+1 Boiler Manifold System

NOTE TO EQUIPMENT OWNER:

Standard Refrigeration And Air Conditioning Questions And Answers Pdf

Tennessee Code/TITLE 62 PROFESSIONS, BUSINESSES AND TRADES/CHAPTER 32 FIRE PROTECTION/PART 1 FIRE PROTECTION SPRINKLER SYSTEMS

2014 City of Revelstoke Woodstove Exchange Program

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

TECHNICAL SPECIFICATIONS

Installation, Operating & Maintenance Instructions. Horizontal Models: LH & HL

BOARD OF EXAMINERS OF LANDSCAPE ARCHITECTS

Transcription:

SERVICE BULLETIN Carrier Corporation 2014 Number: SMB 09-0024A Issued: 6/8/09 SMB 07-0056 Revision: 1/14/14 Title: Enhanced Warranty Policy 40 Tall, Expires: This Policy will be Multipoise 90% Furnace Secondary reviewed and updated semi- Heat Failures annually. Author: Chris Kafura Category: Policy Dept: Building & Industrial Systems Dealer Bulletin Number: None PRODUCT CATEGORY: 90% Gas Furnaces MODELS AFFECTED: 340A, 340M, 345M, 350A, 350M, 351D, 352A, 352M, 355A, 355B, 355C, 355M 58MCA, MCB, MXA, MXB, MSA, UVB, MVP, MVB, MVC, MTA, MTB 490A, PG9M Serial Number Range: 2993A00001 1808A99999 SITUATION: In response to customer feedback, actions are being taken to simplify the administrative work associated with submitting claims for secondary or condensing heat exchangers or furnaces with a failed secondary heat exchanger that meet the criteria in SMB 09-0022. Changes are indicated by bold text. Carrier provides an enhanced warranty on the secondary or condensing heat exchangers for the above listed 90% high-efficiency furnace models, within the stated serial number ranges. This bulletin provides details of the warranty coverage policies and claim process updates. This policy ONLY covers the failure and required replacement of a secondary or condensing heat exchanger and the following related parts: coupling box kits, cold spot baffle, and cell inlet and outlet panels. Failure or imminent failure within 6 months is defined by the following criteria:

2 1. The furnace no longer functions to produce heat due to diagnosed heat exchanger restriction per inspection guidelines provided in SMB 09-0022. 2. The furnace produces heat but fails combustion analysis test due to heat exchanger restriction as diagnosed per guidelines provided in SMB 09-0022. 3. The secondary heat exchanger meets the visual inspection failure criteria per visual inspection instructions provided in SMB 09-0022. The coverage period for this policy is twenty (20) years from original furnace installation date. SOLUTION: This enhanced warranty policy provides two coverage options: Option #1: Flat Rate Allowance to cover the replacement of a failed secondary heat exchanger. Option #2: Monetary credit allowance toward the purchase of a new piece of equipment. Note: Option #2 is only available toward Carrier, Bryant and Payne brand equipment that has a minimum retail value of $1250.00 (not including the cost of installation). Field Action: All dealers and service contractors should refer to SMB 09-0022 / DSB 09-0022 90% Furnace Heat Inspection Procedure to properly troubleshoot and inspect 90% furnace heat exchangers. This policy update is effective for secondary heat exchangers with failure dates of January 14th, 2014 or later. Unless otherwise notified by the distributor, dealers must return secondary heat exchangers from replaced furnaces or the entire furnace from sites that selected Policy Option #2 to the distributor for potential factory audit. It is no longer necessary to return replaced heat exchangers from sites that selected Policy Option #1. A copy of the 90% Furnace Secondary Heat Inspection Certificate must also be attached to or held with the secondary heat exchanger part or furnace. All secondary heat exchangers from replaced furnaces or whole furnaces replaced under this Policy must be held at the distributor for potential factory inspection for thirty (30) days from distributor claim paid date. POLICY: This policy ONLY covers the failure and required replacement of a secondary or condensing heat exchanger and the following related parts: coupling box kits, cold spot baffle, collector box, and cell inlet and outlet panels. Additionally, this bulletin takes precedent over any extended optional contract. All secondary heat exchanger claims for any 90% furnace that is covered by an extended optional contract should be claimed against this bulletin and not against the extended optional contract. Policy Option #1: Replacement of a failed secondary heat exchanger

This option will provide a flat rate allowance to cover labor. The allowance amounts are set at the individual dealer level to allow for proper reimbursement based on registered street rates of 4 hours. All parts associated with the repair must be claimed under the bulletin. This policy option only provides a flat rate labor allowance. Use SMB090024A in the Service Bench warranty system to file a claim for policy option #1. The dealer shall not charge the end-user customer labor for the replacement of the secondary heat exchanger and associated ancillary parts covered under this policy option. 3 Policy Option #2: Monetary credit allowance toward purchase of a piece of new equipment This option will provide a monetary credit allowance toward the purchase of a new piece of equipment. This credit must be used to purchase a new Carrier, Bryant or Payne piece of equipment having a minimum retail value of $1250.00 (not including the cost of installation). The credit cannot be used to purchase a number of different heating or cooling products that together exceed $1,250. The credit may not be used on multiple occasions, and may not be aggregated. If the credit exceeds the purchase price of the new piece of equipment, the consumer is not entitled to a refund of the

excess amount, nor may they apply the excess amount to another piece of Carrier, Bryant or Payne equipment. The credit allowance will provide a flat rate allowance based on registered street rates of 4 hours plus $200 parts credit. Use SMB090024B in the Service Bench warranty system to file a claim for Policy Option #2. Note: All secondary heat exchangers from replaced furnaces or whole furnaces replaced under Policy Option #2 must be held for potential factory inspection for thirty (30) days from distributor claim paid date. A copy of the 90% Furnace Secondary Heat Inspection Certificate must be retained with the secondary heat exchanger part or furnace. The certificate must be retained after the part or furnace is scrapped. 4 Bulletin # HRS MATERIAL DOLLARS DESCRIPTION SMB090024A Flat Rate N/A Replacement of a failed Secondary Heat SMB090024B Flat Rate $200 Credit Allowance towards purchase of a piece of new equipment. This Policy will be reviewed and updated semi-annually.

90% Furnace Secondary Heat Inspection Certificate A copy of this certificate must be held at the distributor with the part or furnace. Following part or furnace scrapping, retain the certificate for potential factory audit. **SCA(s) 5 **Customer Name **Customer Address **Customer Phone # **Model Number **Serial Number Combustion Test Checklist **CO reading Required if furnace is operational Excess air level Installation Checklist check all areas examined per SMB09-0022 Venting Condensate Drain Pressure Switch Hoses Start-up Propane Conversion Thermostat Set Up Safety Control Check Accessories Propane Conversion ppm % Maintenance Items check all items cleaned or examined per SMB09-0022 Air Filter(s) Blower Motor/Wheel Burners/Igniter Primary Heat Secondary Heat Electrical Connections Other Tubing/Hoses After installation and maintenance items corrected - Combustion retest CO reading (2 nd ) test ppm Excess air level (2 nd ) test % Visual Inspection of Secondary Heat **Observations from visual inspection of heat exchanger **If furnace is replaced provide replacement model and serial number **Model Number **Serial Number **Dealer Name/ Dealer Number **Technician Name (Print) **Technician Signature I certify that the secondary heat exchanger in this unit failed or that failure was deemed imminent based on observations documented in this inspection certificate. ** Denotes Required Field