OPTIONAL THERMOSTATIC BLOWER ASSEMBLY No. SC18T

Similar documents
southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

GAS -FIRED VENTED ROOM HEATERS MODEL 61TV

INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL

Models #CSK-31 #CSK-31-RF. CHASKA Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL VENTED ROOM HEATER MODELS RH-25-6 RH-35-6 EFFECTIVE DATE SEPTEMBER 2003

V SERIES HDR GAS RANGES

INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION AND OWNER'S GUIDE

DT-2 & DR-2 MERIT SERIES

UNVENTED (VENT-FREE) BLUE FLAME GAS HEATER SAFETY INFORMATION AND INSTALLATION MANUAL

Models #CSK-335 #CSK-335-RF. CHASKA - XL Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

INSTALLATION AND OWNER'S GUIDE

PROBLEM CAUSE SOLUTION

GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

INSTALLATION AND OPERATING MANUAL

DT/DTH/DR/DRH MERIT SERIES

INSTALLATION INSTRUCTIONS

LENTEK WARRANTY. Directions For Use

VENT-FREE PROPANE GAS HEATER

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use.

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL

LGB Gas fired boiler

#CSK-31-RF. CHASKA Direct Vent Gas Fireplace Insert INSTALLATION & OPERATING MANUAL

INSTALLATION INSTRUCTIONS

GAS COOKTOP INSTALLATION INSTRUCTIONS

Owner s Guide Installation & Operation

USE AND CARE GUIDE WARNING WARNING WARNING WARNING

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

UNVENTED ROOM HEATER

FIREPLACE INSTALLATION

INSTALLATION AND OPERATING MANUAL

MODEL 329 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A FREESTANDING FIREPLACE OR WITH AN OPTIONAL WOODEN SURROUND.

INSTALLATION & OPERATING MANUAL

Owner s Guide Installation & Operation

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLATION AND OPERATION INSTRUCTIONS

MODEL #55801 Duluth INSTALLATION & OPERATING MANUAL. Free-Standing Direct Vent Fireplace

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL

GFP28MLP AND GFP28TLP

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

Installation/Operating Instructions

CYLINDER NOT INCLUDED

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

GE Monogram. Installation. Instructions. Professional Ranges. 48" Natural Gas Models ZDP48N4GWSS ZDP48N6RWSS ZDP48N6DWSS

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

VENT-FREE AMBIENT FLAME GAS WALL HEATER MODEL #KWD155 KWD259 KWD379 KWG363 KWDB252 KWDB372

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

Infrared Cabinet Heater Product Manual MODEL: RC9200IT

π H-7147 SANITAIRE EON QUIET CLEAN VACUUM SAFETY uline.com

VENT-FREE NATURAL GAS MINI-HEARTH HEATER OWNER S OPERATION AND INSTALLATION MANUAL

MODELS: JGM, JGGM, JGT, JGTS, JGTSD, JGTSDS, JGGT, JGGTS, JTYG GRIDDLES AND JHP, JHPE HOT PLATES

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

VENT-FREE PROPANE/LP GAS MINI-HEARTH HEATER OWNER S OPERATION AND INSTALLATION MANUAL

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

INSTALLATION & OPERATING MANUAL

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

NATURAL GAS CONVERSION KIT

MODEL 34 MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A ZERO CLEARANCE FIREPLACE OR WITH AN OPTIONAL SURROUND.

WARNING: This appliance is equipped for Natural and Propane gas. Field conversion is not permitted other than between natural or propane gases.

GA3650TB Blower Accessory

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2E-1

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Installation Instructions Dual Fuel Ranges

INSTALLATION AND OWNER'S GUIDE

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

VENT-FREE NATURAL GAS HEATER OWNER S OPERATION AND INSTALLATION MANUAL

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

VENT-FREE PROPANE/LP GAS MINI-HEARTH HEATER OWNER S OPERATION AND INSTALLATION MANUAL

VENT-FREE BLUE FLAME GAS WALL HEATER

CBN20, CBP20 SBN20, SBP20 CBN20T, CBP20T CBN30T, CBP30T CBT20NT, CBT20PT CBT30NT, CBT30PT CBN20TK, CBP20TK

VENT-FREE NATURAL GAS MINI-HEARTH HEATER OWNER S OPERATION AND INSTALLATION MANUAL

GE Monogram. Installation. Instructions. Professional Ranges. 48" Natural Gas Models ZDP48N4G ZDP48N6R ZDP48N6D

Service Manual Model 3163

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

Owner s Manual. Blue Flame Unvented Gas Heater. 20,000 Btu/hr. Model. 6,000 and 10,000. Btu/hr. Model

INSTALLATION & OPERATING MANUAL

USER S INFORMATION MANUAL

#555 CIRCULATING FAN KIT

Gallery Electric Fireplaces

UNVENTED (VENT-FREE) PROPANE GAS FIREPLACE

OPERATING INSTRUCTIONS AND OWNER S MANUAL

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

INSTALLATION AND OPERATING MANUAL

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

OWNER'S MANUAL WARNING WARNING WARNING WARNING WARNING. Factory No.: HYFP Style No.: WARNING WARNING READ BEFORE USE!

Multi-Function Cooktop

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

CINCINNATI, OH USA

United States Stove Company

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

Transcription:

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. OPTIONAL THERMOSTATIC BLOWER ASSEMBLY No. SC18T INSTALLATION INSTRUCTIONS (for Heater Models SC18T-1, SC18M-1) GENERAL INFORMATION This series is design certified by the CSA Laboratories as an Unvented Heater, and must be installed according to these instructions. ANY ALTERATION TO THE ORIGINAL DESIGN, INSTALLED OTHER THAN AS SHOWN IN THESE INSTRUCTIONS, OR USED WITH A TYPE OF GAS NOT SHOWN ON THE RATING PLATE IS PROHIBITED AND VOIDS THE WARRANTY. The installation must conform to local codes. In the absence of local codes, the installation must conform to the National Fuel Gas Code, also known as NFPA 54 and ANSI Z223.1- latest edition. This is a heating appliance. Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the appliance. These instructions cover the installation of an accessory blower into a new heater prior to installation. If the Heater is already installed then the following instructions shall be referred to for the removal and re-installation of the heater. Form Number Heater Model #43126220 SUNSTAR SC18T-1 #43126210 SUNSTAR SC18M-1 Before continuing to remove the heater, seek a qualified service person to disconnect the gas. READ ALL THE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING THE BLOWER. -1- July 09

INSTALLING OPTIONAL BLOWER 1. Check contents of the carton before proceeding with the installation. Wiring Diagram 1 Nameplate 2 3 4 5 Fan Control Bracket 6 7 8 9 10 11 Fan Control Switch KIT NO. 43740570 for Heaters SC18T-1, SC18M-1 ITEM NO. PART NO. DESCRIPTION QTY ITEM NO. PART NO. DESCRIPTION QTY 1) 43555130 Blower/Motor Sub-assembly 1 7) 30512020 Open/Closed Bushing 1 2) 30516010 Slide Terminal Receptacle 2 8) 30513010 Cord Retainer 1 3) 30517010 Snap Plug Receptacle 1 9) 43556010 Mounting Bracket, L-shaped 1 4) 02315010 Sheet Metal Screw, 3/8 long 9 10) 43563010 Cord Set Sub-assembly 1 5) 02261030 Grounding Screw, Green 1 11) 30749000 Wire Clamp 1 6) 43565090 Fan Control Switch - Automatic 1 2. Lay the heater on a flat surface and remove the 2 screws from each side and lift cover off. Step 1. remove both screws Phillips Head Screw Step 3. Lift Cover off Step 2. Lift Cover up -2- July 09

3. Attach fan Control Bracket and feed wires through the hole. Terminals Fan control bracket Sheet metal screws 4. Turn the heater over, assemble the cord retainer and insert through the back of the heater. -3- July 09

5. Turn the heater over again, insert the plastic bushing into the L Bracket and attach it to the heater. Plastic bushing Sheet metal screws L Bracket 6. Lay down the blower beside the heater and pass the 3 wires through the plastic bushing. Secure fan control switch wires using wire clamp and screw. Wire Clamp Blower L bracket Plastic bushing 3 wires from blower -4- July 09

7. Make electrical connections shown in the diagram below. WIRING SCHEMATIC DIAGRAM OPTIONAL BLOWER 120V Violet White Blower Motor Fan Control Switch Black Violet If any original wire, as supplied with this appliance, has to be replaced, it must be replaced with #18 gauge, 125ºC, 2/64 insulation or its equivalent. Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. -5- July 09

8. Carefully insert the blower assembly under the lip of the heat shield and rotate into place. Blower assembly Blower case Heat shield 9. Lower the blower into the heater and secure both ends with sheet metal screws. -6- July 09

10. Replace the heater cover. LIGHTING INSTRUCTIONS 1. Stop! Read the safety information above. 2. Set the thermostat (gas control knob) clockwise to OFF position. Piezo OFF HI Ignitor LO 3. Turn off all electric power to the appliance. 4. Wait ten (10) minutes to clear out any gas. Then smell for gas near the heater and at the floor beneath the heater. If you smell gas STOP! Follow B in the safety information above. If you do not smell gas, go to the next step. Electrode Pilot is located in the center below the glass front Pilot Burner Thermocouple 5. Turn knob on gas control counterclockwise to P PILOT. Push in control knob to stop and hold. Piezo OFF HI Ignitor LO 6. Repeatedly push the piezo ignitor button until the pilot is lit (a match can also be used to light pilot buner). Continue to hold the control knob in for about 10 to 15 seconds after the pilot is lit. Release knob and it should pop back up. Pilot burner should remain lit. If it goes out repeat procedure 6. If knob does NOT pop up when released STOP! turn off gas supply and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control clockwise to OFF and call your service technician or gas supplier. 7. When the pilot burner remains lit turn the gas control knob counterclockwise to HI (high) position. 8. Turn on all electric power to the appliance. 9. Thermostat (gas control knob) can be set to desired setting from HI to LO. 10.ATTENTION: Gas control has an interlock latching device. When the pilot burner remains lit a safety magnet is energized and the interlock latching device becomes operative. If the gas control is turned to the OFF position or gas flow to the appliance is shut off DO NOT RELIGHT THE PILOT BURNER until the safety magnet is deenergized (approximately 60 seconds). There will be an audible click when the safety magnet in the control is de-energized. Pilot burner can now be relit by repeating steps 3 thru 6 above. TO TURN OFF GAS TO APPLIANCE Turn the thermostat (gas control knob) clockwise to the OFF position. Do not use excessive force when turning knob. Turn off all electric power to the appliance. P P Step 1 Step 3 Step 4 Step 2 STEP 1. STEP 2. STEP 3. STEP 4. Insert tabs along the top edge of the cover into the slots. Rotate the cover down. Insert the tabs on both sides of the heater into the lower slots. Attach the cover with the original screws. FAN CONTROL Thermostatic (automatic) The automatic fan control switch is a non-adjustable automatic type. The fan control will require approximately five (5) minutes of main burner operation before the fan control "closes" and activates the blower. The blower will continue to run approximately five (5) minutes after the main burner shuts off, before the fan control "opens" and deactivates the blower. See diagram of operating sequence below. Pilot Flame Ignition Thermostat (heater) T0 T1 T2 T3 T4 T5 Gas valve Thermostat (fan) Blower Manual Ignition Heater thermostat ON gas valve open Fan thermostat on after 5 mins, blower ON Heater thermostat OFFgas valve close Fan thermostat off after 5 mins, Blower OFF Legend: Function ON: Function OFF: -7- July 09

CLEANING The blower wheel will collect lint and could require cleaning once a year. If the air output decreases, or the noise level increases, it indicates a dirty wheel. Clean the blower wheel with a vacuum cleaner or apply high-pressure air to the blower wheel. NOTE! Unplugging of blower accessory will not stop the heater from cycling. To shut the heater off, turn the control knob to "OFF". WIRING WARNING Electrical Grounding Instructions This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/NFPA #70- latest edition. DO NOT cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter (which has two prongs and a wire for grounding) can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screws. With this wire completing the ground, the appliance cord can be plugged into the adapter and be electrically grounded. SUNSTAR HEATING PRODUCTS, INC. Post Office Box 36271 (28236) 306 West Tremont Avenue (28203) Charlotte, North Carolina Phone (704) 372-3486 Fax (704) 332-5843 Toll Free (888) 778-6782 www.sunstarheaters.com email: info@sunstarheaters.com -8- July 09