SEQUENTIAL CIRCULATOR

Similar documents
SEQUENTIAL CIRCULATOR

SEQUENTIAL CIRCULATOR MODEL 3008

SEQUENTIAL CIRCULATOR MODEL 3008

Multi-Flo Model #1545-KT. Multi-Flo Model #1545-F

Bio Compression s SC-3004-DL

SC-3008-DL SEQUENTIAL CIRCULATOR

Instructions For Use SC-2004-OC, SC-2004FC-OC and SC-2008-OC. Sequential Circulators

Model IC-1545-DL Multi-Flo DVT Combo

Compression therapy device & accessories Model 701A User manual

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

TributeNightTM. user guide

MODEL 7000 SUCTION UNIT

Dyna-Form Air. Alternating Pressure Relief Overlay System

CircuFlow Quick Setup Guide

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

MaxiCompressor. Limited Warranty. High Performance 50 PSI Compressor 501-S

16 OUTDOOR MISTING FAN

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

AIR EXPRESS LAL. P1500 LOW AIR LOSS THERAPY SYSTEM REF C1500 Control Unit REF M1500 Mattress. Operator s Manual P/N /03

The FAWSsit USER CARE GUIDE

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

SAVE THESE INSTRUCTIONS

User Manual standard for Medical Electrical. Control Number 95CG. Classified by. Underwriter s Laboratory Inc. for UL

Food Slicer Visit our website at:

Anti-Decubitus Air Alternating Pressure Mattress System Operation Manual

Antari Low Fog Machine

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A

INSTRUCTIONS FOR OPERATION AND CARE OF

Service Centers: Conair Consumer Products Inc. 156 Parkshore Drive. Brampton, Ontario L6T 5M1

With Remote Control. English

16 Stand Fan with Remote Control Model No: FS3-40R-30

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

CLEAN MIST SMART HUMIDIFIER Instruction Manual and Warranty Information IM0031B READ AND SAVE THESE INSTRUCTIONS

Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss OPERATOR S MANUAL

Digital Fabric Steam Press

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

USER INSTRUCTION MANUAL SAPPHIRE SERIES 800

Note To The User: This product has updated features not yet mentioned in the product manual.

User s Manual. Alternating Air Mattress Model No.: MA-6100

Stand Fan. English. Owner s Guide. Model F R

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Instruction Manual Item No.: V~, 60Hz

Cavitator Ultrasonic Cleaners

AMBIENCE Low Air Loss Mattress Replacement System

CLEAN MIST SMART HUMIDIFIER Instruction Manual and Warranty Information IM0002E READ AND SAVE THESE INSTRUCTIONS

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

User Instruction Manual

Cavitator Ultrasonic Cleaner Instruction Manual

Instructions for Installation and Use

18 INCHES, OSCILLATING STAND FAN

MODEL SF-420. Fabric Steamer. by Top Innovations, Inc. Please read all instructions before use. Mail in your warranty registration card.

Instruction Manual Item No.: V~, 60Hz

The CENTURY. High Performance Oscillating Fan OWNER S GUIDE FOR MODELS 9002X & 9702X

OGCF2002A User Manual

6.6L Stainless Steel Urn. User Manual

Feel Perfect Heated Throw with SleepPerfect Technology Instruction Booklet Please read these instructions carefully and retain for future reference.

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3.

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

10 Table/Wall Mount Fan Model No: FTY-25 Operating Instructions FTY Soleus Air International

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

IMPORTANT SAFETY INFORMATION

Operator s Manual. Wet/Dry Vacuum with Detachable Blower 12 Gallon Model No. VBV1210 FOR YOUR SAFETY

Operating Manual Model BP500 and BP500 IJ Tape Dispenser

CONSTANT SUCTION UNIT

Natural Mist Humidifier. Vicks. (Model V3500) IMPORTANT! READ AND SAVE THESE INSTRUCTIONS. Use and Care Manual

INSTALLATION AND OPERATION MANUAL

Instruction Manual. Head & Eye Massager with Acupressure and Heat Compression.

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

Enhance DX. Mattress Replacement System. User Manual

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

LED IMPORTANT SAFETY INSTRUCTIONS

Med-Aire Assure 5 Air + 3 Foam Base Alternating Pressure and Low Air Loss Mattress System

English 1 AIR ALTERNATING PRESSURE MATTRESS REPLACEMENT SYSTEM

Operator s Manual. Floor Vac Model No. VF408 FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

BL Series INSTRUCTIONS

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

HR1-08R-21 Reflective Heater Operating Instructions. Model No. HR1-08R Soleus Air International

OWNER MANUAL PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

MaxiCompressor. evo. High Performance 50 PSI Compressor TH PLACE ADEL, IOWA 50003

User s Manual Warm N Cozy

Sealed Electric Wall & Floor Mounted Towel Warmers. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual.

PARTS AND SERVICE MANUAL FOR. DIMPLEX PURIFIRE ELECTRIC STOVE Model TDS8515

With Remote Control. English. Model

Instruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath

WA A Aqua Sub Bottom-load Water Cooler

USER MANUAL SAVE THESE INSTRUCTIONS

Easy-Lam School Budget Roll Laminator

75th anniversary blender

MS-11 Flat Panel Reflective Heater Operating Instructions. Model No. MS Soleus Air International

DIGITAL FABRIC STEAM PRESS INSTRUCTION MANUAL

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

MANUAL VERSION SERIAL # X-1 MINI PRO OWNER S MANUAL ASSEMBLY & OPERATOR INSTRUCTIONS 1.0

OWNER MANUAL PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE

User Instruction Manual

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

INSTRUCTIONS FOR OPERATION AND CARE OF

Transcription:

SEQUENTIAL CIRCULATOR MODEL SC-3008 120 West Commercial Avenue, Moonachie, NJ 07074 Toll-Free Phone: 800-888-0908 / Phone: 201-939-0716 Fax: 201-939-4503 Web site: www.biocompression.com E-mail: biosystems@biocompression.com U.S. BASED MANUFACTURER 1

Congratulations on the purchasing of your BIO COMPRESSION SYSTEMS MODEL # SC-3008 Sequential 8 Circulator System The durable, high quality material used in the manufacturing of this product will ensure you long lasting performance. On rare incidences when problems occur, you can feel confident that your pump and garment are backed by the best warranty and customer service in the industry! By simply dialing our toll free number for customer service 800-888-0908 warranty repairs or adjustments will be performed in a timely manner with minimal inconvenience to you Should a warranty repair require an extended length of time, if available, a pump from our loaner inventory will be made available to you, so as to prevent any interruption in your treatment schedule. 2

The Model # SC-3008 Sequential Circulator is a manual (not software driven) sequential, pneumatic compression device intended for either primary or adjunctive treatment of primary or secondary lymphedema. The device is also intended for additional or alternate treatment of venous insufficiency and venous stasis ulcers associated with venous insufficiency as well as general treatment for swelling of the extremities. The device is intended for both home and hospital use. CAUTIONS AND PRECAUTIONS CAUTION: Federal law restricts this device to sale by, or on the order of, a licensed physician. CAUTION: High pressure should be set with caution on patients with peripheral arterial occlusive disease. CAUTION: To prevent the potential for reverse pressure and retrograde flow, do not adjust the gradient pressures without physical supervision. CAUTION: If you experience pain or unusual symptoms during use, discontinue treatment and consult your physician immediately. CAUTION: In the event of a power failure, simply unplug the garment from the pump to release any residual pressure in the garment. CAUTION: The system is not intended for use during sleep. SYMBOL DEFINITIONS = REFER TO DOCUMENTATION BEFORE USING AND SERVICING = TYPE B APPLIED PART = CLASS II PROTECTION 3

CONTRAINDICATIONS INFECTIONS IN THE LIMB WITHOUT APPROPRIATE ANTIBIOTIC COVERAGE, INCLUDING CELLULITIS THE PRESENCE OF LYMPHANGIOSARCOMA DEEP VEIN THROMBOSIS (DVT) INFLAMMATORY PHLEBITIS OR EPISODES OF PULMONARY EMBOLISM CONGESTIVE HEART FAILURE GENERAL EQUIPMENT SPECIFICATIONS Model # SC-3008 - Segmental 8 Circulator Segmented, Sequential Pneumatic Compression Device with Calibrated Gradient Pressures DIMENSIONS: H X W X D in INCHES 5.5 x 12 x 8 WEIGHT: 8 lbs INFLATION: 44 SECONDS DEFLATION: 5.5 SECONDS CYCLE TIME: 5.5 SECONDS / CHAMBER ( Electrical Specifications under separate section) PACKAGING, SHIPPING & STORAGE The Model# SC-3008 is shipped in a specially designed (275 test) corrugated reusable carton with protective end-caps which envelope each end of the pump, thereby suspending the pump on all four sides within the carton. This packaging design prevents damage to the pump (which would ordinarily be sustained) when the carton is thrown or handled roughly by the carriers. NOTE: The carton and end-caps should be saved for re-use each time the pump is either transported or shipped. When transporting, for added convenience, the carton is equipped with a fold-up handle assembly The device should be stored in a secure area, ideally 60 to 80 degrees (F), however, short term storage or shipping with exposure to temperatures of 20 F to +110 F will not harm the unit. To maximize the unit s life, however, time should be allowed for temperature adjustment prior to use, when moving to areas of contrasting temperature. It is also advisable to avoid extreme heat ( +110 F) or cold (-20 F) when long term storage is contemplated. 4

CONTROLS & INDICATOR PUMP 3 2 1 4 5 6 7 CONTROL DESCRIPTIONS 1) LIGHTED ON/OFF SWITCH 2) PRESSURE ADJUSTMENT KNOB, LOCKING To prevent against involuntary changes in the pressure setting due to inadvertent movement of the Pressure Adjustment Knob, a locking Pressure Adjustment Knob has been implemented on all model pumps to provide for safer, more effective therapy. After the pressure has been set, simply by turning the smaller inner locking knob clockwise to tighten, the pressure adjustment knob will now remain secure in place. Turning the inner knob counter -clockwise will enable the pressure adjustment knob to again turn free without resistance. CAUTION: CARE MUST BE TAKEN NOT TO OVER-TIGHTEN THE INNER LOCKING KNOB AS ONLY MINIMAL FORCE IS REQUIRED TO LOCK PRESSURE SETTING IN PLACE. NOTE: CHANGING THE INNER KNOB TO A 1/2 x 8/32 ALLEN HEAD SET SCREW WILL UPGRADE THIS FEATURE TO TAMPER PROOF. 3) PRESSURE GAUGE ( mmhg) 4) AIR SUPPLY PORTS (NUMBERED) PORTS #1-#4 PORTS #5-#8 5) AUXILIARY RECEPTOR PORTS FOR LATCH CONNECTOR BAR. 6) CAPPED AIR SUPPLY PORTS FOR LATCH CONNECTOR BLOCKER BAR PORTS #1-#4 PORTS #5-#8 7) ADJUSTABLE GRADIENT PRESSURE OVERRIDE (Located on Underside of Pump) 5

UPPER EXTREMITY GARMENT WITH TUBING PLUGS ATTACHED 8 8 BILATERAL TREATMENT APPLICATION When bilateral treatment is required, remove the Latch Connector Blocker Bar from Auxiliary Air Supply Ports (#6 under controls & indicators) and attach the Latch Connector Bar in the same manner. ADJUSTABLE GRADIENT PRESSURE NOTE: When a pressure adjustment is made to any individual chamber, one must be conscious of the overall gradients across all chambers so as not to create reverse gradients. 8. LATCH CONNECTOR BAR (Numbered/White Circle (O) 6

ELECTRICAL SPECIFICATIONS The Model # SC-3008, Sequential Circulator s electrical pump and components are double insulated and thus do not require a protective ground. As a result, the Model SC-3008 is equipped with an 18 gauge, 2-wire, 10 ft. power cord, secured through the pump casing with a Heyco strain relief bushing. Affixed to the rear exterior of the pump is a 3 x 3 Foil Label containing the Electrical Specifications printed in contrasting black type. These specifications are printed in both English and French and contain the following: ELECTRICAL RATING: 120 VAC, 60Hz, 0.5 A CARACTERISTIQUES ELECTRIQUES: 120 V c.a., 60 Hz, 0, 5 A When servicing, use only identical replacement parts. Do not remove cover. Refer to qualified service personnel. Lors des reparations, utilisez, exclusivement des pieces de re change identiques. No retirez pas le couvercle. Consultez un tech niciaen qualifie. WARNING: REPLACE FUSE WHERE MARKED ADVERTISSEMENT: REMETTRE LE FUSIILE A L ENDROIT INDIQUE Fuse rated 3 Amps Time Delay, 250 VAC Fusible de 3 A a retardemente, 250 V c.a. Continuous Operation with Intermittent Loading TYPE B APPLIED PART CLASS II Pie ce Applique e Type B CLASSE II ETL 9801681 CONFORMS TO CONFROM A Authorized service personnel, in addition to possessing proper tools and testing equipment have access to electrical schematics, calibration criteria and an inventory of identical replacement parts. 7

CLASSIFICATION 1.) Class of protection against electrical shock.. CLASS II EQUIPMENT 2.) The degree of protection against electric shock.. APPLIED PART TYPE B 3.) Mode.. CONTINUOUS OPERATION WITH INTERMITTENT LOADING 4.) According degree of protection against ingress of water.. IPXO FUSE REPLACEMENT Occasionally power surges, etc. or normal age can result in a blown outer safety fuse located in the rear of pump, adjacent to the power cord. The safety fuse may be replaced by the user or caregiver, provided it is replaced with an identical type (T3AL 250V). Prior to removal of fuse, disconnect power cord from socket. While pushing inward on fuse cap, turn counter clockwise to release cap and remove fuse. After placing new fuse in cap slot, push cap and fuse inward and turn clockwise to lock in place. NOTE: The outer safety fuse is the only item serviceable by someone other than a Bio Compression Systems technician at the factory. Bio Compression Systems technicians have been trained specifically for the manufacturing and repair of all Bio Compression Systems products. NOTE: Having no electromagnetic or radio frequency signal sensitive type components, this device neither generates, nor is it affected by any of this of interference. Further, its accuracy remains consistent in the presence of such devices emitting this type of interference. PUMP ENCLOSURE The pump enclosure is constructed of Cycolac which is a trademark of General Electric. UL FLAME RATING: Under file #E47016, The UL Test method of UL 94, @ 23 C, resulted in a Flammability Rating of (2.3 VO) 8

UNPACKING EQUIPMENT SEQUENTIAL CIRCULATOR By laying carton on its side, slide pump out with protective end caps still attached. After removing pump from carton, protective end caps may be detached by gently pulling off each side. NOTE: Be sure to SAVE carton and end caps for future transporting or shipping. When transporting, the carton is equipped with fold-up handles for easy carrying. SLEEVE/GARMENT Remove sleeve from package and unroll tubing section which is permanently attached to garment with tubing plug attached to the end. TUBING: The garment tubing is produced in pleural form consisting of two groups of 4 Tubes bonded together and color coded with 3 tubes in blue and 1 tube in black. This color coding prevents attachment of both tubing bundles to the pump is reverse order. The tubing is 80A durometer PVC with each tube measuring.281 x.187 with a Tolerance of +/-.005. OPERATING INSTRUCTIONS Having familiarized yourself with the controls and features of this equipment, you are now ready to begin your treatment according to your physician s prescribed course of therapy. 1. Make sure that your circulator is plugged into a safe, properly secured, 110 V, AC outlet. 2. Place unit on a sturdy table or other type surface close to where you will be sitting. The unit has non-slip-rubberized feet on the bottom, however placing paper or other items underneath may defeat that purpose, causing unit to slide off of surface. 3. The Model #SC-3008 operates at a faster inflation cycle per chamber which allows less time for setting or adjusting the pressure in chamber #1 (the only chamber in which the pressure should be set). Once the pressure has been set, the pump automatically adjusts for slightly lower pressures in each chamber as it sequentially inflates each chamber in a distal to proximal direction. In preparation to adjust or set the pressure, to maximize available time, you should first loosen the inner locking knob so that the pressure adjustment knob can immediately be adjusted without resistance. Observing the gauge needle will enable you to set the desired pressure (turning the knob clockwise to raise the pressure and counter clockwise to lower it. 9

SETTING THE PRESSURE The physician is required to prescribe these settings, but general guidelines are listed below: 60mmHG is the general rule of thumb for most patients. However, other circumstances may require adjustments to the compression used. Presence of fibrotic tissue may require as much as 80mmHG in order to break up the fibrotic tissue and achieve reduction. Once the tissue is soft, the compression can be readjusted to 60mmHG. Patients with a history of Congestive Heart Failure, which is controlled with medication should never be in a flat position while pumping. They should be in a reclined position with elevated legs during treatment. Their treatment regimen duration may be divided into twice a day 30 minutes per treatment. Patients with a history of Deep Vein Thrombosis with or without a filter may require less compression. These patients will generally tolerate 40mmHG. These patients with a filter may need to divide their treatment into twice a day, 30 minutes per treatment. It is suggested that the provider obtain a Negative Doppler study from the physician for their records. All compression settings should be discussed with the physician. It is ultimately his/her responsibility to prescribe the setting and it should be written on the prescription upon referral. Every patient is unique and communication with the physician is important when setting pressures. NOTE: Remember, the pressure adjustment must be made before the pump cycles to chamber #2. Should this occur, the pump must be re-set to inflation of chamber #1. 4. Take the LATCH CONNECTOR BAR which is located at the end of the tubing on your garment. Holding in one hand with the numbers facing up, squeeze ends together to line up (1 to 1) & (4 & 4) to Air Supply Ports (#4) then push onto AIR SUPPLY PORTS (#4). You should hear a click when fully engaged. 5. Repeat the previous steps to attach the LATCH CONNECTOR BAR (#8) to remaining AIR SUPPLY PORTS (#4) if using more than one garment. 10

6. Unzip sleeve/garment gently down to bottom stop (zipper does not separate). Place garment onto arm or leg and zip up to top of garment. 7. Press PUMP SWITCH (#1) up to the ON position. Allow two to three complete inflation / resting cycles before the garment reaches its pre-set therapeutic pressure. 8. As each chamber of the garment inflates, the PRESSURE GAUGE (#3) will dip down momentarily then return to reflect the actual pressure in each chamber. This will continue as each chamber becomes pressurized with each cycle. INTERNAL ONE HOUR TREATMENT TIMER The Model #SC-3008 Sequential Circulator is equipped with a one hour internal treatment timer which automatically begins at the start of your treatment with the pump/controller shutting off once the one hour treatment time has been reached. After taking a full one hour treatment, the pump/controller will automatically shut itself off. Note that although the switch light will go out, the switch itself will remain in the On position. As a result, prior to taking your next treatment, you must first flip the On/Off switch down to the Off position, wait at least 10 seconds (enabling the pump to again re-set itself for another one hour treatment cycle), then flip the switch up again to the On position, at which time you will note that the switch will light as you begin your next treatment. END OF TREATMENT When your treatment time is completed, press the PUMP SWITCH (#1) down to the OFF position. As noted earlier, although the pump shuts off, the switch may remain lighted until the timer completes it cycle, at which time it will automatically shut off. Unplugging the power cord at this point will cut total power to device. Once the light has shut off, it is also safe should you desire, to remove the garment. 1. Squeeze Latch Connector Bar (#8) and pull outward to remove garment from pump. 2. First gently bend your arm or leg (depending where garment is located) to release some air from chambers. 11

3. Continue to assist in the evacuation of air from garment, working from top to bottom. 4. Once the garment feels loose enough, you can unzip the garment all the way to bottom and remove. NOTE: Repeat above steps if bilateral garments are used! ADJUSTING GRADIENT PRESSURES 1. Model # SC-3008 Sequential Circulators provide total Calibrated Gradient Pressure. 2. All gradients have been carefully calibrated at the factory resulting in the highest pressure in chambers #1 & #2 graduated down to the lowest in chambers #7 & #8. 3. The main PRESSURE ADJUSTMENT KNOB (#2) sets the pressure for sections #1 & #2 of the sleeve. As it is adjusted, it will also raise or lower in proportion, the remaining sections. 4. In the unlikely event you would wish to change the gradient settings calibrated at the factory, it is possible to do so by using the over-ride adjustments (#8) on the underside of the pump. (See Overriding Pre-set Gradient Pressures next page) 5. We described earlier how the Pressure Gauge responds to filling pressures with a brief dip before raising back up to the actual pressure. NOTE: Repeat above steps if bilateral garments are used! 12

OVERRIDING PRE-SET GRADIENT PRESSURES 1. A small screw driver is the only tool needed to adjust the gradient pressures. 2. If you turn the pump on its side, you will notice underneath, three screw ports labeled #3&4, #5&6 and #7&8, each having a directional arrow indicating the way in which the pressure is increased. 3. It only takes a very small turn of the screw to adjust as you are adjusting (mmhg) as reflected on the gauge. 4. With the pump on its side and while running, observe the gauge needle to set the desired pressure. WARRANTY INFORMATION You can feel confident that your product is backed by the best warranty in the industry covering any and all malfunctions (including parts and labor) resulting from component and/or manufacturing defects. Compression Pumps = 3 years from date of purchase / invoice Sleeves/Garments = 1 year from date of purchase / invoice NOTES: Serial Number: Date Purchased: Local Representative/Dealer: REPAIR SERVICE 1-800-888-0908 BIO COMPRESSION SYSTEMS, INC. 120 West Commercial Ave., Moonachie, NJ 07074 www.biocompression.com 13

MAINTENANCE AND STORAGE Exterior Pump Case Cleaning Instructions: 1. Clean the exterior case and tubing with a damp (not wet) cloth using mild soap and water solution once per month or as needed. WARNING! Only an authorized technician may open the pump Before cleaning, unplug power cord from electrical outlet GARMENT CLEANING/DISINFECTING INSTRUCTIONS: Disconnect garment from device. 2. Open garment to expose all sides either by separating Velcro type hook and loop or by unzipping (depending on type of garment). WARNING! Do not allow liquids to enter the pump, as this can present an electrical hazard Always allow the pump to dry before using Do not use bleach on the pump 3. Cleaning solution should consist of 1/3 cup of laundry detergent per 1 gallon of warm tap water. Use either a large sink or plastic tub able to hold enough solution (depending on size and quantity of garments) to completely submerge the garment leaving the latch connector bars out of the water. 4. Garment should be soaked for 30 minutes with mild agitation every 5 to 10 minutes while keeping it below water surface. 5. Thoroughly rinse garment with warm tap water and allow to air dry. WARNING! Never allow the Latch Connectors to be submerged into the water. If water enters the inside of the garment, damage may occur to the device. 6. Harder to remove soil on surface of garment may require additional washing by hand with a clean towel while submerged. Avoid using any abrasive materials such as scrubbing pads or chemicals that could cause damage to the exterior surface of garment. 7. Re-Submerge garment for 30 minutes (with exception of tubing connectors) in solution consisting of 1 cup of bleach per 1 gallon of warm tap water, again agitating garment every 5 to 10 minutes while keeping garment below water surface. Rinse garment thoroughly with warm tap water and allow to air dry. This completes the disinfecting step. WARNING! DO NOT place garment in washing machine. WARNING! DO NOT use the tubing or valves as handles for carrying, handing or storing garment. 14

OTHER BIO COMPRESSION SYSTEMS PRODUCTS ALSO AVAILABLE: SEQUENTIAL CIRCULATOR MODEL 2004 & 2004-FC SEQUENTIAL CIRCULATOR MODEL 3004 & 3004-FC SEQUENTIAL CIRCULATOR MODEL 2008 THE BIOCRYO SYSTEM MULTI-FLO DVT COMBO PROPHYLAXIS SYSTEM BIOARTERIAL PLUS (ARTERIAL BLOOD FLOW ENHANCEMENT SYSTEM) COMPRESSION THERAPY GARMENTS INCLUDING OUR CUSTOM GARMENTS 15

O r g a n i z a t i o n Bio Compression Systems, Inc. 120 West Commercial Avenue Moonachie, NJ 07074 Toll-Free Phone: 800-888-0908 / Phone: 201-939-0716 Fax: 201-939-4503 E-mail: biosystems@biocompression.com Website: www.biocompression.com Emergo Europe Prinsessegracht 20 2514 AP, The Hague The Netherlands L006 Rev C 16