INSTRUCTION MANUAL HEAT DISTRIBUTION / TV KIT N A T U R A L LY V E N T E D [ ]

Similar documents
C44 INSTRUCTION MANUAL HEAT DISTRIBUTION / TV KIT N A T U R A L LY V E N T E D [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

C Series. Cool Surface System INSTRUCTION MANUAL SIDE VENT [ ] PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

GAS. F I R E P L A C E s

Manufactured by Sherwood Industries Ltd Victoria, BC, Canada enviro.com Printed in Canada, April 2017

designed to heat. built to last. GAS FIREPLACES

City Series CV40E Gas Fireplace

WOOD FIREPLACE INSERTS

designed to heat. built to last. GAS FIREPLACE INSERTS

City Series CB40E Gas Fireplace

P P Gas Fireplace. P See Thru

TCWS54STODK FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

City Series CC40RE Gas Fireplace

Cooktop Chimney Ventilation Hoods

DaVinci Heat Exchanger Touch-Screen Version

Greenfire GF950L Gas Fireplace

C44 OWNER S MANUAL DIRECT VENT FIREPLACE - NOVA WARRANTY REGISTRATION enviro.com/warranty

G39G. DIRECT VENT FIREPLACE - nova OWNER S MANUAL

DaVinci Heat Exchanger

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

WALL MOUNTED ELECTRIC FIREPLACE HEATER. Model # : Onyx Ivory Mirror OWNER S MANUAL. AC V 60Hz 1500W

VERTICAL POWER VENT KIT

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Installation Instructions

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

Installation Manual EF5000 AUS & NZ

for architects & designers

Pellet Stove. Flex Pipe. Appliance Connector

Installation Instructions

X-593 SOLID FUEL HEATING QUESTIONNAIRE

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

PelletVent Multi-fuel venting system. UL 641.

C44I OWNER S MANUAL DIRECT VENT FIREPLACE - IPI WARRANTY REGISTRATION enviro.com/warranty

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

The Sherwood Home Collection

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Ventis Direct Vent. Installation Instructions

CARLTON 46 & CARLTON 39

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual.

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Corn Flame Energy Corn Stove Model 3000

CARLTON 46 & CARLTON 39

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

INSTALLATION INSTRUCTIONS MANUAL STEEL GAS STAR COOKTOPS 30" MODELS: SGS304, SGSX304 36" MODELS: SGS365, SGSX365 45" MODELS: SGS456, SGSX456

Intrigue 42 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL: UF0100 GAS FIRED DIRECT VENT FIREPLACE S/N AND UP

tççç= ÜÉ~íáåÖ çéíáçåë

Installation and Operation Manual

WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.

O-T L. Installation and Operation Manual BAYPORT-41 GLASS

INSTALLATION AND OPERATION INSTRUCTIONS FOR

OWNERS MANUAL FOR MEC 300E ATA

BAYPORT 41 & BAYPORT 36

Regency Horizon HZO60 Outdoor Gas Fireplace

LINEAR GAS FIREPLACES. enviro.com

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION AND OPERATING MANUAL

DANGER. Installation and Operation Manual CARLTON-39

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

EMPIRE UNIVERSAL FIREBOX FOR ALL VENT-FREE LOG SETS. Deluxe Vent-Free Universal Fireboxes MODELS

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

BAYPORT 41 & BAYPORT 36

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

NOTICE CAUTION DANGER DANGER WARNING

napoleonfireplaces.com WOOD BURNING WOOD BURNING FIREPLACES

Heat-N-Glo. Installers Guide. Model: 8000TVC

INSTALLATION INSTRUCTIONS

Installation Manual Installation and Appliance Setup

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

ZC Kit AGP Pellet Insert

WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.

SURE HEAT MANUFACTURING

INSTALLATION AND OPERATING MANUAL

carlton 46 & carlton 39

36 Elite Installation Manual

Installation Manual EF5000 NZ

Xtreme 6020 Fireplace

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

564 Cleanface (SS) GSR2 Fireplace

Installation Instructions

Installation Electric Dryers Instructions 01

DANGER. Installation and Operation Manual SPRINGFIELD 36

Owner's Manual Residential Factory Built Fireplace Operation Maintenance Installation ORACLE2

WARNING INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

The Monterey (PENNINSULA) MODEL PN36 3-SIDED, WOOD-BURNING FIREPLACE

6015 HO GSR2 (with screen) Installation Manual

3615 HO GSR2 (with screen) Installation Manual

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT

INSTALLATION AND OPERATING MANUAL

INSTALLATION GUIDE Dual Fuel Ranges

Custom Series In-Wall and In-Ceiling Loudspeakers

Owner s Guide and Installation Manual

Transcription:

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE C Series HEAT DISTRIBUTION / TV KIT N A T U R A L LY V E N T E D [ 5 0-3 3 9 5 ] INSTRUCTION MANUAL 4001609 This Heat Distribution Kit has been tested for compliance to Standards: ANSI Z21.88-2014 and CSA Z2.33-2014. This Heat Distribution Kit has been approved for use on the ENVIRO C34/44/60 Direct Vent fireplaces only and must be installed at the time of fireplace installation. The following instructions must be followed in conjunction with the fireplace installation instructions to comply with the standards and allow safe operation of the installed fireplace. Version Française: www.enviro.com/fr.html 50-3306

General Information The purpose of this optional Heat Distribution Kit, or HDK, is to naturally re-direct the convective heat from the fireplace. Using this HDK lowers the temperatures of the front wall for installations where a TV, artwork etc. is desired directly above the 2 fireplace. The outlet of the HDK can be 1 raised higher up the front wall, within 4 of the room s ceiling, or ducted into a different room for a cleaner front wall. 4 Note: Dual Convection Fan Kit (50-3212) may not be used in conjunction with HDK. 5 3 Prior to installation of the HDK make sure the desired location is large enough to comply with the combustible clearances of both the HDK and the fireplace (see Owner s Manual for fireplace installation instructions). Refer to the Framing and Clearances section of this manual for the required installation dimensions of the HDK. Please refer to Figure 1 to ensure that all HDK parts are accounted for and have not been damaged. 6 Item Description Item Description 1 Main Duct Body 4 Outlet Trim Bezel 2 Right Standoff 5 Vent Collars 3 Left Standoff 6 Hi-Limit Switch Figure 1. Heat Distribution Kit - Parts Diagram Dimensions 9 3 8 " (23.8 cm) 2 3 4 " (7 cm) Standoff 11 7 8 " (30.2 cm) 2 1 2 " (6.6 cm) Standoff 40" (101.6 cm) 45" (114.3 cm) 31 3 4 " (80.6 cm) 1 2 " (1.3 cm) 3 1 2 " (8.9 cm) 2 5 8 " (6.7 cm) 7 5 8 " (19.4 cm) 25" (63.5 cm) 5" Vent Collars 2 1 8 " (5.4 cm) 7 3 8 " (18.7 cm) Figure 2. Heat Distribution Kit - Overall Dimensions 2

Framing & Clearances Framing & Rough Opening: Refer to Figures 3 & 4 for the minimum allowable framing and rough opening of the HDK. HDK Outlet Min. Top and Bottom standoff = 2⅝ (6.7 cm) *All C Series* C34 45" (114 cm) 7 1/2" (2.5 cm) 2 x 4 (On Edge) 2 x 4 (On Edge) 37 1/4" (94.6 cm) Min. Height Steel Stud 3 Figure 3. C34 - HDK Framing & Rough Opening

Framing & Clearances C44 & C60 Figure 4. C44/60 - HDK Framing & Rough Opening 4

Minimum Clearances - minimum vent: Framing & Clearances Shown below in Figure 5 are the minimum framing and clearances for the HDK when the fireplace is installed with the minimum allowable vent length: Min. Ceiling Clearance from top of HDK outlet = 4 (10.2 cm) Min. Ceiling Clearance in wall from top of HDK Body = 5⅝ (14.3 cm) HDK Body Min. Rear standoff = 2¾ (69.8 cm) 4" (10.2 cm) 5 5 8 " (14.3 cm) 80 (203 cm) Min. Ceiling 2 3 4 " (69.8 cm) Min. Vent 73 1 4 " (174.9 cm) Side Brace Min. Height 39 (99 cm) Min. Length 5 dia. flex vent (not supplied) 20" (50.8 cm) Min. Depth 5 Figure 5. HDK - Min. Framing & Clearances

Minimum Clearances - vertical vent: Framing & Clearances The HDK has been designed to allow for installations where a vertical run of vent is required without having to jog the vent pipe around the HDK (see Figure 6). The horizontal vent shield supplied with the fireplace is not required (see Owner s Manual) when vertically venting and the vent pipe can simply be run straight up through the cut out in the HDK. Minimum Clearances - Adjoining Room: The HDK may also be installed to discharge into another room for a cleaner installation on the fireplace side of the wall (see Figure 6). As stated in the previous section, the vent pipe can be ran straight up through the cut out in the HDK. The minimum clearances stated in Figure 6 must be maintained as well as the minimum distance between the fireplace and the HDK (see figures 3 & 4). 4" (10.2 cm) 80 (203 cm) Min. Ceiling Warning: HDK MUST NOT discharge outdoors or into a garage. HDK is only approved for horizontal installation and MUST NOT be installed in a floor or ceiling. 73¼" (174.9 cm) Side Brace Min. Height 74¼" (188.6 cm) Min. Height to bottom of outlet When installing the HDK in an adjoining room the 5 dia. flex venting cannot exceed a vertical run of 12 (3.65 m). The flex venting also cannot exceed a horizontal run in excess of 8 (2.5 cm) for every 12 (30.5 cm) of vertical rise, up to a maximum of 8 (2.4 m). 20" (50.8 cm) Min. Depth Figure 6. HDK - Adjoining Room 6

Finished Opening: Framing & Clearances Combustible wall material i.e. drywall, shiplap etc. is permitted around the outlet of the HDK with a 3/8 (.95 cm) air gap required around the outside perimeter of the outlet. This creates a finished opening approx. 40¾ x 2⅞ (103.5 x 7.3 cm) in size (Figure 7). 2 7 8 " (7.3 cm) 3 8 " (1 cm) 40 3 4 " (103.5 cm) Figure 7. HDK - Outlet Finished Opening The supplied Outlet Trim Bezel, once installed, covers the air gap for a clean finished install (Figure 8). The Trim Bezel can be adjusted to accommodate finished walls ½ -1 (1.3-2.5 cm) thick and be painted to match the colour of the wall if desired (must be hi-temperature rated). Figure 8. HDK - Outlet with Trim Bezel 7

TV Installation Considerations: Installation Installation and service must be performed by a qualified installer, service agency or the gas supplier. If you are planning to mount a TV above your fireplace some considerations must be made to ensure it is protected from the heat. During testing temperatures did not exceed 120 F (49 C) midway up the front wall (Figure 9). There is no guarantee that these temperatures will not harm the longevity of your TV. Make sure to consult your TV manufacturer s specifications to find the maximum allowable operating temperature. Since every home and installation is unique, temperatures should be verified at the time of install if possible. If desired, front wall temperatures can be lowered further with the use of a mantle (Figure 10). Refer to Owner s Manual for full mantle clearances. A TV should not be installed if temperatures exceed the manufacturers maximum allowable temperature. 2 1 2 " (6.4 cm) Min. 2 (5 cm) gap 1 1 2 " (3.8 cm) Min. air gap behind TV (Typically provided by wall mount) Min. 3/4 (1.9 cm) Mantel Thickness See Mantle Instructions in Owner s Manual for further information Figure 9. HDK - TV Clearances Figure 10. HDK - TV Clearances 8

Installation Hi-Limit Switch: (For Use with IPI Fireplaces Only) Supplied with the HDK is a Hi-Limit switch assembly that must be installed if the HDK is being used on an IPI equipped fireplace. Installation of the Hi-Limit switch is easy and only takes a couple minutes. Step 1: Prior to installation of the fireplace, remove the safety screen assembly. Next, remove the front cover using a T20 screwdriver (see Figure 11). Step 2: Using a T20 screwdriver, loosen the left mounting screw of the IFC and slide the Hi-Limit Switch Bracket onto the IFC as shown. Next, retighten the left mounting screw (see Figure 12). Note: Placement of the Hi-Limit switch is not arbitrary and must be correct for proper operation. When correctly installed, the bracket should contact both the mount flange and left side of the IFC (Figure 12). Figure 11. Front Cover Removal Long Wire Figure 12. Hi-Limit Switch - Correct Placement Short Wire Figure 13. Hi-Limit Switch - Correct Wiring Step 3: Using a small flat-blade screwdriver, loosen the terminals on the IFC ON/OFF plug (X4 on IFC) and remove the jumper wire (see Figure 13). Next, insert the wires from the Hi-Limit Switch and retighten the terminals. There is no polarity to the wires so they cannot be wired backwards. Step 4: The Hi-Limit Switch installation is now complete. The front cover and safety screen may now be re-installed on the fireplace. Note: In rare circumstances, when the HDK is installed in an adjoining room, a large difference in room pressure may temporarily cause the HDK to reverse flow. If this occurs over a prolonged period of time the Hi-Limit Switch will automatically turn off the fireplace to protect the IFC. Once the fireplace has cooled sufficiently (approx. 10-15 minutes) it will automatically re-start and continue normal operation. 9

Installation Duct Collars: Prior to fireplace installation, the two supplied duct collars must be attached to the top of the fireplace as shown in the steps below: Step 1: Using a T20 screwdriver, remove the inner and outer cover plates from the fireplace as shown (Figure 14). Each cover plate has four (4) mounting screws. Both sets of cover plates are no longer required and can be recycled. Retain eight (8) of the removed mounting screws to secure the duct collars. Outer Cover Plate (x2) Inner Cover Plate (x2) Duct Collars Figure 14. Cover Plate Removal Step 2: Attach the supplied duct collars to the top of the cabinet as shown (Figure 15). Secure the collars by re-using the eight (8) screws saved in the previous step. The fireplace is now HDK ready! Figure 15. Duct Collars Installed Side Supports / Standoffs: Prior to installation of the HDK the supplied set of side support/standoffs need to be attached to the sides of the main duct body. The side supports also incorporate the rear standoff as shown in figure 16. Side Support / Standoff Rear Standoff Using a T20 screwdriver and the supplied screws 6 screws (3 per side), attach the left support as shown in figure 16. Repeat for the right side support. Figure 16. HDK - Side Supports 10

Installation Heat Distribution Kit: Step 1: Frame in the rough opening for the HDK as shown in Figures 3 & 4 (Pages 3,4) in the desired location following all required clearances as stated in the Framing & Clearances section. Note: Light coloured ceilings may slightly discolour near the outlet when it is installed at minimum clearance (4 / 10.2 cm). Increasing the ceiling clearance will help prevent this. Step 2: Using a T20 screwdriver, remove the screw on each side of the HDK outlet retaining the Outlet Trim Bezel and remove the Bezel (Figure 17). Step 3: Insert the assembled HDK into the framed rough opening by rotating it down slightly to allow the outlet and standoffs to pass through. When installed correctly the front flange of the top standoff should be up against the front face of the top stud (Figure 3 & 18). Step 4: Confirm the HDK is centered within the rough opening and secure in place using screws or nails through the four (4) holes along the top edge of the top standoff. Figure 17. Outlet Trim Bezel Screw Step 5: Secure the rear standoffs to support the remainder of the HDK ensuring it is level. If left unlevel, the outlet of the HDK will be out of square causing possible fitment issues with the Outlet Trim Bezel. Step 6: Install the fireplace in the desired location as directed in the Owner s Manual. Leave the front wall open for installation of the flex venting. Note: Flex venting must be non-insulated and listed to UL 1777 and ULC S635 standards Step 7: Connect the required lengths of 5 dia. stainless steel Figure 18. HDK - Top Standoff or aluminium flex vent (not supplied) between the collars on the fireplace and HDK. Secure the venting to the collars using either sheet metal screws or band clamps. Both collars on the HDK must be connected to the fireplace via 5 dia. flex vent. Secure the flex venting where necessary to maintain standard venting clearances: Table 1. Flex Vent - Minimum Clearances Vertical Pipe to the Side Walls Horizontal Pipe to the Sides & Bottom Above an Elbow Above the Unit Above an Elbow Not Above the Unit Above Horizontal Vent Pipe 1 (25.4 mm) 1 (25.4 mm) 3 (76.2 mm) 3 (76.2 mm) 2 (51 mm) 11

Installation Step 8: Finish the front wall around the fireplace and HDK outlet as desired. Ensure the finished opening around the HDK outlet is as specified in the Finished Opening section of this manual. Step 9: Finally, install the Outlet Trim Bezel by sliding it into the outlet until the backside 1 4 " (6.4 mm) Warning: HDK outlet MUST NOT be covered or blocked in any way by drapes, furniture etc. contacts the finished wall surface. Next, reinstall the two (2) screws removed in Step 2 to secure the Outlet Trim Bezel in place. When installed correctly there is a ¼ (6.4 mm) standoff between the back side of the Bezel and finished wall (Figure 19). Figure 19. Outlet Trim Bezel - Standoff Installation of the Heat Distribution Kit is now complete and the remaining fireplace installation can be completed as directed in the Owner s Manual. 12

Replacement Parts 2 1 4 3 Item Description Part Number 1 HDK Instruction Manual 50-3306 2 Outlet Trim Bezel 50-3307 3 Hi-Limit Switch (IPI only) 50-3308 4 Vent Collars (Set of 2) 50-3309 13

Notes 14

Learn more about our products at Detailed Product Lineup Model Photo Galleries Downloadable Manual PDF s Unit Comparison Charts Youtube Burn Example Videos Online Brochures Dealer Locator Tool 15

MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.enviro.com April 3, 2017 C-15118