Weishaupt WG10 and WG20 gas burners LN (Low NO x ) version 2/2002 CA

Similar documents
Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

product WM 20 oil, gas and dual fuel version Weishaupt monarch WM20 burners compact and powerful Information on oil, gas and dual fuel burners

product WM 30 oil, gas and dual fuel version Weishaupt monarch WM30 burners highly efficient and versatile

RIELLO 40 GS/M SERIES

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Power Flame Incorporated

Bosch Uni 7000F Cast Iron Hot Water Boiler

MONOBLOCK NG SERIES GAS BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

Light oil burners. One stage operation

Power Flame Incorporated

Forced draught gas burner

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

LOW NOx MODULATING GAS BURNERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

RS /E-EV C01 SERIES

R-Series Oil Burners. Riello Burners a world of experience in every burner we sell. Reliable Combustion Solutions

Oil burners Brûleurs fioul Stookoliebranders

STEAMPAK Series BurnerPAK BMS Burner Management Systems

HCLEARFIRE. High-efficiency, modular steam boiler HP

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

product Ultra Low NO x emissions WM-G10 ZM-PLN and WM-G20 ZM-PLN monarch burners (290 10,240 MBH) Information on Ultra Low NO x gas burners

Zantingh Burner systems. Reliable energy-saving and environmentally friendly heating solutions

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Complete burner management in a compact, affordable system

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

Control Products & Systems OEM

DIVISION FINNED WATER-TUBE BOILERS

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Burner control unit BCU 370

New Features RIELLO ARRAY. v2.0. High Efficiency Condensing Boiler MBH.

Forced draught gas burner

TWO STAGE HEAVY OIL BURNERS

MONOBLOCK GAS BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Max-3 Steel Shell Boiler

DIVISION FINNED WATER-TUBE BOILERS

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Advanced Heating and Hot Water Systems

info The Weishaupt programme Burners Heating systems Solar technology Heat pumps Information on Weishaupt products

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

RS /E-EV C01 SERIES

Complete burner management in a compact, affordable system

Quickheat 30 weather compensated boiler control

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev.

WATER-TUBE POOL HEATERS

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

Indirect gas-fired air heater

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

Industrial Applications

1 - High-velocity gas burners

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

PCH/new Series. High performance, total flexibility

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

The mechatronics of EVE 05

INSTRUCTION MANUAL FOR OIL BURNER MODELS

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Suggested Specifications Prestige Excellence 110

Parts Available from

DIVISION FINNED WATER-TUBE BOILERS

Gas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

FINNED WATER-TUBE POOL HEATERS

FAMILY PRO SIMPLY THE BEST

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Boilers Variable Fire Boilers

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Control Products & Systems OEM

Burner control unit BCU 370

LFL Series Burner Flame Safeguard Control

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Concrete Applications

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

INSTRUCTION MANUAL FOR OIL BURNER MODELS

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Forced draught natural gas/propane burner

MERIT SERIES Downflow

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Service life twice as long (6,000 operating hours). Automatic altitude adjustment of the Hydronic M10 / M12 up to 3,500m.

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

Now Available with PVC & Polypropylene Vent Configurations

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

ENERGY TOP. Condensing boiler solutions

Transcription:

Weishaupt WG0 and WG20 gas burners LN (Low NO x ) version 2/2002 CA

New W series capacity range The Weishaupt WG0 and WG20 gas burners join the WG5, WG30 and WG40 to complete the line-up of products successfully introduced over the course of the last few years. As with all new W series Weishaupt burners, the WG0 and WG20 burners also use the latest microprocessor technology for the control and monitoring of all burner functions. As a result not only do they offer improved precision and ease of use, but they also represent fantastic value for money. Mixing head An outstanding detail of the low-emission LN burners is the specially developed mixing head. The specific way in which combustion air and gas are introduced leads to intensive flue gas recirculation. Various tests and results from the field have shown that the NO x limit of 40 ppm (calculated as NO 2 ), which is required in many countries for natural gas, can be improved upon as long as certain combustion chamber conditions are adhered to. With corresponding combustion chamber conditions, figures of 58 ppm can be achieved with LPG. Economical The best technology, functional design and proven quality have always been the hallmarks of Weishaupt products. With the WG0 and WG20 gas burners, we are introducing new burners that continue this tradition in an exemplary fashion. They fulfil the demand for economical and environmentally friendly operation combined with a low purchase cost. Fully automatic operation The burners function fully automatically. They reliably cater for multifarious heat exchangers for heating and hot water. Compact construction All of the new burner type s components are brought together into a compact space. The fuel and air regulating components are clearly laid out and easily accessible. The mixing head can be accessed from behind and completely removed. The burner can be hung on the left hand side of the casing during servicing. This enables easy access to the fan in particular. An easily removable cover protects all the components and electrics. Noteworthy points: The radial fan, the sound absorbing air inlet housing, the air damper for suction side air regulation and the microprocessor controlled combustion manager. The W-ZG 0 electronic ignition unit, which has replaced the ignition transformer on all W series Weishaupt burners, provides reliable ignition. Error-free plug connection Coded plug connections ensure the correct electrical connection of all components. Gas multi-function assembly The newly conceived multifunction assembly comprises the following components/functions: Servo controlled gas regulator for a constant gas pressure 2 solenoid valves Low gas pressure switch If the gas pressure drops too far the low gas program is initiated. Operational safety and reliability. Proven technology makes the new gas burners safe and reliable. The individual components as well as the completed product are comprehensively tested, guaranteeing safe operation for many years. Test procedures The WG0 and WG20 gas burners comply with European and North American applicable standards, including: UL std 795-999 CGA std 3.4-973 CAN/CSA std C22.2 No.3-988 CGA std 3.0-968 Fuels The following fuels can be fired: Natural Gas as well as Liquid Petroleum Gas. In standard version, the burners and gas train are only suitable for indoor operation. 2

Single and two stage operation with W-FM 0 combustion manager Gas butterfly valve Air stepping motor (linked to gas butterfly) W-FM 0 combustion manager Single and two stage operation W-FM 0 combustion manager The W-FM 0 combustion manager independently monitors and controls all of the burner s functions. Digital combustion management makes communication with other systems possible. The BUS connection allows the engineer to monitor the sequence of operations and diagnose any fault conditions. The main details: Microprocessor controlled combustion manager for single and two stage operation Identical for both oil and gas burners Ionization flame monitoring 7 and 4 pole connection plug integrated into burner housing Electrical remote reset BUS connection Prepurge time can be set by computer via the BUS Safety via two microprocessors (reciprocal monitoring) Multi color LED annunciation to indicate operational stage and fault conditions Suitable for hot water plant, including continuous operation (After 24 h operation a necessary short shutdown takes place automatically) Suitable for air heaters and steam boilers 3

Sliding two stage and modulating operation with W-FM 20 combustion manager Air stepping motor W-FM 20 combustion manager Gas stepping motor Sliding two stage and modulating operation W-FM 20 combustion manager The W-FM 20 combustion manager independently monitors and controls all of the burner s functions. Digital combustion management makes communication with other systems possible. The BUS connection allows the engineer to monitor the sequence of operations and diagnose any fault conditions. The main details: Identical construction for oil and gas burners Automatic recognition of gas or oil burner Easy operation via a key on the display panel LCD display to show the following Operating mode with ratings setting Information mode Hours run - Number of burner starts - Measured fuel consumption with corresponding gas meter - Unit number - Software version - Date of manufacture Service mode - Burner setting values - Error message display Parameter mode - Air damper setting at burner shutdown - Post purge time - BUS address Error messages Electronic compound fuel/air regulation to given characteristics Control of stepping motors Multifunctional Bus connection to: PC for presentation of the operational sequence and setting of function parameters Remote monitoring and diagnosis via self-dialling modem Interfacing with other components of the heating plant (e.g. controller or DDC unit) 4

Installation, setting and service: Easier, quicker and more precise than ever before Time is money Weishaupt burners of this rating are also easy to install. It is possible for one person to mount the burner on the boiler. Optimum accessibility Optimum accessibility becomes apparent the moment the cover is removed. All the components are clearly laid out, electrical connection is unmistakable. The components are also easily accessible for servicing. The mixing head can be matched to the required rating with the setting screw. It can be accessed from behind and completely removed with ease. This state of the art technology is typical of Weishaupt products. The motor block can be removed and placed into a service position for servicing the fan. Every service engineer benefits from this accommodating construction. Easy removal of the mixing head The service position allows good access to the fan. 5

Technical Data Capacity graph: WG0.../-C gas burner Capacity graph: WG20.../-C gas burner WC Burner type Combustion head Rating WG0.../-C WG0-C 85 375 MBTU/h* WC Burner type Combustion head Rating WG20.../-C WG20-C 20 685 MBTU/h* 0.8 0.6 0.4 0.2 0-0.2-0.4 MBTU/h 00 50 200 250 300 350 400 Depending on the altitude of the installation, a reduction in capacity of approx. % per 328 ft. above sea level must be taken into consideration. Model Overview Burner type Version Mode of operation Gas train Order number Rating size MBTU/h* WG0 Natural Gas WG0 N/-C Z-LN Single or two stage 3/4 232 3 24 85 375 WG0 N/-C ZM-LN Sliding two stage or modulating 3/4 232 6 24 85 375 LPG WG0 F/-C Z-LN Single or two stage 3/4 233 3 24 85 375 WG0 F/-C ZM-LN Sliding two stage or modulating 3/4 233 6 24 85 375 WG20 Natural Gas WG20 N/-C Z-LN Single or two stage 232 23 34 20 685 WG20 N/-C ZM-LN Sliding two stage or modulating 232 26 34 20 685 WG20 N/-C Z-LN Single or two stage 232 23 44 20 685 WG20 N/-C ZM-LN Sliding two stage or modulating 232 26 44 20 685 LPG WG20 F/-C Z-LN Single or two stage 3/4 233 23 24 20 685 WG20 F/-C ZM-LN Sliding two stage or modulating 3/4 233 26 24 20 685 Optional equipment WG0/-C, ZM WG0/-C, Z WG20/-C, ZM WG20/-C, Z Order number Order number Order number Order number Hours run meter, inbuilt 230 008 0 230 008 0 Solenoid valve for air pressure switch test on continuous running fan or post purge 230 007 98 230 003 29 230 007 98 230 003 29 Head extension Natural Gas by 4 (00mm) 230 008 49 230 008 49 230 007 80 230 007 80 by 8 (200mm) 230 008 50 230 008 50 230 007 8 230 007 8 by 2 (300mm) 230 008 5 230 008 5 230 007 82 230 007 82 LPG by 4 (00mm) 230 008 52 230 008 52 230 007 83 230 007 83 by 8 (200mm) 230 008 53 230 008 53 230 007 84 230 007 84 by 2 (300mm) 230 008 54 230 008 54 230 007 85 230 007 85 DLU digital ratings convertor 230 007 06 230 007 06 Remote reset 230 007 97 230 007 97 230 007 97 230 007 97 integrated into W-FM 20 combustion manager on ZM version * The burner ratings are based on lower calorific value 0.8 0.6 0.4 0.2 0-0.2-0.4 MBTU/h 00 200 300 400 500 600 700 Minimum 275 MBTU/h rating at high fire for WG20. 6

Technical Data Burner type Combustion Motor Stepping Ignition Air pressure Display Burner Gas Flame manager motor unit switch weight train sensor WG0../-C Version Z-LN W-FM 0 ECK 03/F 2/ STD 4.5 * W-ZG 0 AA-A2-4-5 without 30 lbs. 3 lbs. Ionization Version ZM-LN W-FM 20 0 V, 60 Hz STE 4.5 ** AM 20.02 (approx) (approx) 0.3 kw, cap. 4 µf WG20../-C Version Z-LN W-FM 0 ECK 04/F 2/ STD 4,5 * W-ZG 0 AA-A2-4-5 without 44 lbs. 3 lbs. ➀ Ionization Version ZM-LN W-FM 20 0 V, 60 Hz STE 4,5 ** AM 20.02 (approx) 5 lbs. ➁ 0.2 kw, cap. 8 µf (approx) * Operational runtime: max. 50 s across full setting range / min. 25 s across reduced setting range / approx. to 2 s during prepurge ** Operational runtime: approx. 3 s across full setting range / < 3 s across reduced setting range / approx. 3 s during prepurge Gas train layout Explanation of designation P 7 W G 20 N.../-C LN F 2 4 5 6 LN = Low NO x Index N = Natural gas F = LPG Size G = Gas burner Weishaupt W series burner 3 P Ball valve 2 Additional gas pressure regulator (optional) 3 Gas pressure switch 4 Gas valve 5 Gas pressure regulator 6 Gas butterfly valve 7 Burner * The burner ratings are based on lower calorific value 7

Dimensions Scope of delivery WG0.../-C burner dimensions Scope of delivery 3/4 Burner with sound absorbing inlet housing.0 3.7 6.6 4.3 6.5 3.9 Housing with burner motor and fan wheel Flange with servicing bracket, fixing screws and gasket Air regulation housing with servomotor controlled air damper 3.7 5.5 5.9-6.7 4.3 3.0 LN (LowNOx) mixing head with diffuser and ignition and ionization electrodes Combustion head 6.5 W-ZG 0 electronic ignition unit with shielded ignition line.2 4.5 WG20.../-C burner dimensions 6.4 45 M8 Sensor line (ionization) equipped with test point Microprocessor controlled W-FM 0/W-FM 20 combustion manager with integrated plug console and externally accessible 7 + 4 pole BUS connection Cover.2 0.8 3.8 4.7 7. 4.8 Complete gas train For further detailed information please refer to the technical documentation provided with the burner 5.6 5.5 4.0 6.7 5. 7..3 6.2 7.0 45 M8 Weishaupt Corporation 6280 Danville Road Mississauga, ON L5T 2H7, Canada Tel: (905) 564 0946 Fax: (905) 564 0949 Email: sales@weishaupt-corp.com www.weishaupt-corp.com 8 Print No. 8320326, February 2003 Printed in Germany. All rights reserved.