Thank you for choosing the CompX elock refrigerator kit. Quick Programming Guide

Similar documents
Temperature Monitoring

Refrigerator Kit. k Four (4) washers k Two (2) strike cover machine screws k Four (4) housing cover screws k Eight (8) sheet metal mounting screws

CompX elock Instructions

Architectural. Specifications Guide

Instruction Manual. , Keyless Locking 1

Nest x Yale Lock Installation and Programming Guide. Back button Check (Set / Continue) Keypad

Application Version: 2.0 and above Date Written: 03/09/2010. Copyrights , Global Security Devices, All Rights Reserved

Cardax System Comparison

EntryCheck E70 Series

shine TM Manual User guide and installation instructions The global leader in door opening solutions

Installation and Maintenance Manual IM 1038

JOVY SYSTEMS RE User Manual Rev. 1.00

THX-DL Data Logger USER & INSTALLATION MANUAL V

Room Sensor for BACnet VAV Actuator

EC-BOS-602/616 AX Security

CV-350 TCP/IP Access Control System. System Overview

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

Contents Description... 3 AZOR kit contents... 4 Installation... 7 Control Settings System extension Other information...

DIGI*TRAC Annunciator Guide DTA

Auditcon 2 Series Commercial Safe Locks Models 52 / T52 / 252/ 552

Operations Manual TS400. Test Station for G450/G460 Gas Detector

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

Wireless Access Control Light Commercial Lockset. WIACCOCAT - Wireless Access Control Light Commercial Lockset Catalogue_

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

iminiplus PDF User Guide Version 2.0

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

User Manual. Humidity-Temperature Chart Recorder. Model RH520

EUROSCAN RX2-6 / TX2-6

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

User Manual Keep this manual safe for future reference

CD30 Codoor. Instruction Manual

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

Follett Performance Plus

ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

EURO User Manual. For use with EURO 76, MSX 162, MSX 280 software: Version 9.1 or above RINS1527-2

System Manual W A R N I N G. PC6O1O Software Version 2.1

Monitoring Operator Guide. Access Control Manager Software Version

Omniguard 4: Features

TX3 Series TX3-CX-1. Installation Manual

EasyLog Data Logger Series

For more information on Abloy UK visit ACCESS CONTROL

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

NetworX NX-548E Receiver Installation Instructions

Please read and save these instructions. Should you have any questions or difficulty installing your fan, call us first!

INSTALLATION INSTRUCTIONS

G4S SMARTalarm User Guide

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

Operations Manual TS400. Test Station for G450/G460 Gas Detector

FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT!

User Manual YDM The functions and design of this product can be changed without notice for quality improvement. Chinese manual is from 33 page.

L O D G I N G S Y S T E M S

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

Digital & Card Access Control Systems

For ios devices MYQ-G0301 MYQ-G0301C MYQ-G0301-D MYQ-G0301LA

FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F

EURO 46 User Manual. For use with EURO 46 (version 9.1 or above) RINS1531-2

DIGI*TRAC Annunciator Guide

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

Exceptional solutions for key and portable item control. electronic lockers and key cabinets

\ Page 1

DIGITAL. Operation & Installation Guide. Read These Instructions Very Carefully! Home and Office Security Safes MFFS2054DF84DF18DFE0809 ENGLISH

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

ELMTEC. Kattreppeln Königslutter / /

SMARTair Proximity access control

SCAN200E USER S MANUAL

WARNING Important Safety Information

Installation/Owner s Manual Models 1504 / 1506

Alarm Lock A Division of the Napco Security Group 333 Bayview Avenue Amityville, New York Phone (631) Fax (631)

EasyLog Data Logger Series

SIMATIC IPC DiagBase SIMATIC. Industrial PC SIMATIC IPC DiagBase. Introduction. DIAG software components. Quick-Start Guide

SOLO Installation manual STAND-ALONE PROXIMITY ACCESS CONTROL SYSTEM

LineGuard 2300 Program User Manual (FloBoss 107)

ARCHITECTURAL DOOR HARDWARE KEY PADS & CARD READERS CATALOG

MPL3115A2 Sensor Toolbox User s Guide

Aperio Technology Wireless access control - The evolution starts here

Advisor Advanced User Guide

WARNING Important Safety Information

Mechanical to Electrical Making the Jump

Set & $ave. Model Programmable Thermostat. installation and operation manual

Upgrade Your Solution: Mechanical to Electrical

Easikey 1000 / 1000 Plus

TV2 Clean Room Monitor

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE SYSTEM. HANDLE THE EQUIPMENT CAREFULLY.

Checkout Procedure Manual

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at

Access CONTROL. MANAGEMENT Software

Table of Contents. What to Expect with. Mounting Options. Tools Needed

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

Installation & User Manual V1.1

Uplink Remote Installation Guide 5500EZ

Transcription:

Thank you for choosing the CompX elock refrigerator kit. CompX elock is a highly engineered lock with a motor-driven latch. Its uncompromising lock control electronics include a non-volatile memory that stores 250 user / supervisor codes and audit trail. With optional LockView audit trail software, CompX elock remembers 1500 access attempts. Programming is simple with numeric keypad or Windows TM based LockView software. Numeric Keypad Magstripe / Keypad Dual System Prox Reader / Keypad Dual System Magstripe Card Quick Programming Guide 1. GETTING STARTED: a. The unit is shipped with no user / supervisor codes b. Press and hold until the beeping stops c. Input the new PIN (4 digit min) and press or present new card d. This PIN / Card is now a supervisor in slot #001 2. ADD A USER: c. Input the new user PIN (4 digit min) and press or present new card 3. ADD A SUPERVISOR: c. Press and hold again until beeping stops d. Input new supervisor PIN (4 digit min) and press or present NEW supervisor card 4. DELETE A USER OR SUPERVISOR: c. Input the PIN to be deleted and press or present existing card to be deleted 5. ADD A USER WITH A SPECIFIC SLOT ASSIGNMENT: c. Enter slot number that will be assigned to user and press (example: to program slot 6 type 006 ) d. Input the new user PIN (4 digit min) and press or present NEW card Prox Reader 6. DELETE A USER WITH A SPECIFIC SLOT ASSIGNMENT: c. Enter slot number to be cleared and press (example: to clear slot 6 type 006 ) d. Enter slot number to be cleared again and press (example: to clear slot 6 type 006 ) See programming guide included with optional LockView software for advanced programming instructions. What's in the box? 8 - #8 tamper resistant.5 screws 2 - #8 tamper resistant 3/8 screws 1 - strike plate 1 - strike plate cover 1 - CompX elock instruction sheet 3 - double-sided tape 7.5 X 1 1 - complete elock refrigerator kit (batteries not included) 1 - series of serial code stickers (keep in a safe place) 1 - factory reset card (magstripe or prox units only) What's needed? k T15 pin-in-head torx tool k 6 - AA batteries k tape measure (or ruler) k drill (if doing drilling installation) 1

Installing the Refrigerator Kit 1: Install the strike Note: The end of the metal strike needs to curve up. There are two main parts of this installation: installing the strike and installing the elock assembly. The strike and the elock assembly can be mounted either with foam tape or by drilling holes and using screws. It is important to note that mounting the strike and the elock assembly are independent of each other. One can be foam tape mounted, and one can be drill mounted if desired. The two do not need to be mounted using the same method. Mount the strike at least 3.5" from Non-hinged edge of the refrigerator. Foam Tape Installation Please note that if foam tape installation of the strike is used, the strike will not be adjustable once it's put in place. a. Clean top of both the refrigerator and the strike with rubbing alcohol. Wait for the alcohol to dry. b. With a pencil, mark refrigerator 7-1 16" from the front of the door and at least 3.5" from the non-hinged edge. Measure from this line to the front of the cabinet (dim. A ); cut a piece of tape this length. c. Remove tape backer and affix to end of strike. The upward curve should be on top. Apply tape to the opposite side. Remove backer. Line up strike with line on refrigerator; apply pressure to seal it on. Drilling Installation a. Before drilling, verify that there are no refrigerant lines inside the top of the refrigerator. b. Drill a 9/64" hole, 6-1 16" from the edge of the front of the refrigerator and at least 3.5" from the non-hinged edge of the refrigerator. 2: Secure the strike and attach the strike cover (if strike was mounted using foam tape, ONLY do b.) a. Screw one tamper resistant sheet metal screw into the center of the strike's slotted area. Note: The end of the metal strike needs to curve up. b. Place the plastic strike cover over the metal strike. If strike was mounted using foam tape, please proceed to 3. c. Attach with one tamper resistant machine screw. 2

Installing the Refrigerator Kit continued 3: Mount the main CompX elock body to the refrigerator door The CompX elock assembly (body) can be mounted to the front of the refrigerator either by using foam tape or by drilling holes. Foam Tape Installation Please note that if foam tape installation of the strike is used, the main CompX elock will not be adjustable once it's put in place. a. Install one piece of double-sided tape on each side of the CompX refrigerator elock assembly. b. Remove liner from double-sided tape. c. Carefully press CompX elock onto the center of the strike. Drilling Installation a. Click CompX elock onto strike. b. Push assembly up and center it on the strike. c. Drill six 9/64" holes through the housing into the refrigerator door for the mounting screws. Secure with screws. Note: Top two screws may be omitted if they interfere with door handle access. Note: If foam tape was used to mount the strike, the CompX elock refrigerator kit installation is COMPLETE. The CompX elock may now be used. Finish installation of the strike (ONLY if drilled installation of strike was used) 4: a. Remove the plastic cover from the strike plate. Drill 9/64" hole in second opening of strike. b. If adjustment of strike is needed, loosen up the first strike screw and adjust the strike. Tighten up the screw. c. Drill hole for second screw and install second screw. d. Reattach the plastic strike cover and attach with two tamper resistant machine screws. 3

CompX elock Accessories SUPERVISOR HID Prox User, Supervisor Card EL-2004-PC (no logo) EL-2004-PC-S (CSP logo) Magstripe User, Supervisor Card EL-2004-MSC (no logo) EL-2004-MSC-S (CSP logo) LockView Software Kit (provided with 7 ft., 6-pin RJ11 cable, 1-USB dongle, 1 LockView CD) EL-2004-LV HID Prox Tag EL-2004-PT Screwdriver EL-DRV-15 Bit EL-BIT-15 HID is a trademark of HID Corporation. LockView 3.0 Software q Add, edit, view and delete users / supervisors and their credentials q Add, edit and delete CompX elocks q Assign access rights between users / supervisors and CompX elocks in the database q USB connection required q Download, view, save, print, archive and delete audit trails * These items are offered as Service / Replacement Parts only. q Dual credential access available q Set real time clock q Time based access restrictions q Create user groups q Windows TM based q View Temperature Logs q View Temperature Graphs q Edit Temperature Settings NOTE: Don't forget to fill out and return your warranty card! LockView is a Registered Trademark of CompX International. Windows is a trademark of the Microsoft Corporation. Specifications may vary based on user application. 864.297.6655 compx.com elock@compx.com PO Box 200 Mauldin, SC 29662 4 Part #: 331634-0000-00 Rev B Copyright 2009 CompX Security Products

CompX elock Warranty Card These stickers are included with each CompX elock unit. Please review the information and keep the stickers in a safe location as they may be needed to reset or identify a specific elock unit. The codes shown here are not real codes. They are representations of what the stickers will look like. Sticker #1 2d bar code. Provides the same information as sticker number three, but a 2d laser scanner is needed to decode the information. Sticker #2 Sticker #3 1d bar code. Place this sticker on or around the CompX elock unit to help identify which codes to use if resetting the lock is necessary. Keep this sticker in a safe location. Serial #: Needed to identify CompX elock units Passcode: Unique to lock. Needed for LockView. Prevents unauthorized LockView use User Rst: Allows administrator or owner to erase all user codes from elock unit but keep supervisor codes Fact Rst: Erases all codes from elock, including settings. elock unit will need to be set up again after a Factory Reset (see page 2) (SAMPLE) CompX elock Registration card Company Phone# ( ) - Address Authorized Contact Position Serial # Pass Code User Reset Code Factory Reset Code Sticker #3 NOTE: Don't forget to fill out and return your warranty card! Affix one copy of sticker #3 to the CompX elock registration card and return to CompX Fort at address shown on the other side of the registration card. 5