LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Similar documents
WATCHMAN AREA VOLTAGE DETECTOR

V-WATCH PERSONAL VOLTAGE DETECTOR

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

TAG MR VOLTAGE DETECTORS AND ACCESSORIES. Instruction & Operation Manual

MaxLite LED MICRO-T PANEL

MaxLite LED Vapor Tight Linear Fixture

Compact Equipment Warranty Policy

ion Genesis Pump Controller

MaxLite LED Round Pendant Highbay Series

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

BACKUP BATTERY INSTALLATION INSTRUCTIONS

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Blade Series Heat Exchanger Operation and Installation

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

Duct Mount. Installation Instructions

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

View the expanded manual: GEN5

Design Criteria. Installation

TrueClean ToteCleaner

Air Pump Up to 800 gallons

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

TrueClean ToteCleaner

Owner s Manual. PIR-1 IR Learner

INSTRUCTION MANUAL HS-229G

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

VX SERIES Wireless Thermostat with Occupancy Sensor

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

Remote Relay Module (RRM)

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

6502B RF Distribution

MaxLite LED High Bay Fixtures

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

CD6102 / CD6102 OC / CD6102-2

IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Projection Alarm Clock USER GUIDE

Clean Steam Generators

Multiple Boilers Electro TS Series Application EB-C-STG5

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

Spy Jeepmeter ope rati ng instructions

Instruction Manual WARNING

MN908 No. 282C Replaces 282B LB7013

(HSTAT Series) Instruction Manual

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Installation & Operation Manual

CONDENSING WATER BOILERS. (Models VLT , Q VX ,

- User Brochure Programmable Thermostat 510

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

MGC Dock User s Manual

Controllers. Instruction Manual WARNING

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

First Year Limited Warranty for Residential Use Condensing Water Boilers (Includes Heat Exchanger and Component Parts)

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

HotPoly Tote Tank / IBC Heaters (TTH Series)

Installation and Operations Manual

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

DUST FREE CARBON Whole House Air Purifier

Power Pack Service Manual

Remote Vehicle Control System

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

INSTRUCTION MANUAL P Heating and 1 Cooling

User s guide RUH series Economical unit heater Replacement component list included

OPERATION & INSTALLATION MANUAL

To get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer.

PAD100-6DB & PAD100-4DB PAD100-PD

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

OWNERS MANUAL MODEL 451 (-101 & -201)

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Integra Family. Operations Manual. Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Serial Number:

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

Technical Data Approvals UL Listed and FM Approved. Refer to Tables 1, 2, and 3, as applicable.

EQUIPMENT Operation Manual

Owner & Operator s Manual. Table of Contents

YOUR PORTABLE AIR PURIFIER

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

Light Construction Equipment Consumer Warranty Policy

User s Manual and Operating Instructions

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

PROFESSIONAL SERIES PENDANT SPEAKER PS-P63T

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Transcription:

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories Operating & Instruction Manual 1475 Lakeside Drive Waukegan, Illinois 60085 U.S.A. 847.473.4980 f a x 8 4 7. 4 7 3. 4 9 8 1 w e b s i t e : w w w. H D E l e c t r i c C o m p a n y. c o m

2

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories Operating & Instruction Manual DESCRIPTION.............................................................................4 IMPORTANT SAFETY INFORMATION......................................................4 HOW TO USE IT............................................................................5 BATTERY REPLACEMENT..................................................................5 TECHNICAL SPECIFICATIONS.............................................................7 ACCESSORIES.............................................................................7 LIMITATION OF WARRANTY AND LIABILITY...............................................8 3

DESCRIPTION The LV-5 is a hand held low voltage detector for testing exposed metallic surfaces and conductors for the presence of low voltage 50/60Hz AC. This Detector is designed to be hand held as shown and to detect AC voltage on any metallic surface or conductor that is in direct contact with the metallic tip of the Detector. The presence of AC voltage greater than 5 volts is indicated by a flashing red light. The LV-5 is always on and ready to detect voltage. IMPORTANT SAFETY INFORMATION CAUTION: The Detector should be hand held as shown. Keep hands and fingers behind the hand guard at all times. This device can be used to detect voltages up to 600VAC. Do not exceed 600VAC with direct contact. This Detector is designed for use by trained professionals. Use caution before contacting any equipment or conductor on which AC voltage is detected. The voltages detected by this Detector may be lethal. WARNING: This Detector does not detect DC. Flashing light indicates AC voltage. Do not use the LV-5 Detector or LV-PT Tester except as directed. Do not use the Tester with equipment other than the LV-5. Contacting voltage above 600V with the Detector or applying the Tester to energized circuits or equipment may lead to electric shock, severe injury or death. Refer all servicing to the factory. 4

HOW TO USE IT TEST THE LV-5 DETECTOR with the LV-PT Tester before and after each use. The Tester supplies a non-lethal low voltage AC signal to the metal button in the center of the clear plastic cone. To test the LV-5 Detector, hold the Detector as shown and press the to tip of the LV-5 into the metal button of the LV-PT Tester. If the LV-5 will be used with a gloved hand, this testing shall be performed while the hand holding the Detector is wearing the same glove that will be used while performing the actual stray voltage test. A red light on the Tester indicates the battery is OK. A flashing red light on the Detector indicates voltage is detected. Note that for best test results, the holster should be worn as shown. The hand on the Detector and the placement of the holster on the user are part of the test circuit and can affect test results. If the holster is not used as shown, similar body contact must be maintained between the Detector and the Tester. For example, the hand of the user can be placed behind or around the body of the Tester while the other hand holds the Detector, as shown on page 4. TEST FOR VOLTAGE Test for voltage by touching the metal tip of the LV-5 Detector to an exposed metal surface of the equipment or conductor to be tested. Hold the Detector by hand as shown above. The hand of the user is part of the detection circuit. A flashing red light indicates voltage of 5 volts or more. OPERATIONAL IMPAIRMENT If the LV-5 is used in a manner not described in this instruction manual, the protection and effective operation of this equipment may be impaired. BATTERY REPLACEMENT INSTRUCTIONS To replace the LV-5 batteries, unscrew the tip, remove and dispose of the old batteries, replacing them with two fresh, new alkaline or lithium type AA batteries. For the LV-PT, remove the four screws and replace the 9V battery with a fresh, new 9V alkaline or lithium type. 5

TECHNICAL SPECIFICATIONS Model LV-5 includes LV-5 Stray Voltage Detector. Model LV-5/K01 Kit includes LV-5, LV-PT Tester and LV-HS Holster. Optional accessories include LV-EH Extension Handle and LV-GS Ground Shield. See page 7 for details. DIMENSIONS: 10.5 in. L x 3.8 in. W x 2.3 in. H (26.7 cm x 9.7 cm x 5.8 cm) WEIGHT: 1.25 lb (570 g) BATTERY: LV-5 Detector: 2 x AA alkaline ANSI-15A, IEC-LR6 or lithium ANSI 15-LF, IEC-FR6 LV-PT Tester: 9V alkaline ANSI 1604A, IEC 6LR61 or 9V lithium ANSI-1604LC THRESHOLD DETECTION VOLTAGE: 5VAC, 50/60Hz Nominal, capacitively coupled MAXIMUM APPLIED VOLTAGE: 600VAC ENVIRONMENTAL CONDITIONS: Indoor and outdoor use ALTITUDE: Up to 6,566 ft. (2000M) OPERATING TEMPERATURE: -20 F to +140 F (-29 C to +60 C) HUMIDITY: 95% to +60 C (non condensing) POLLUTION DEGREE: PD4 MEASUREMENT CATEGORY: Classification Rating (CAT IV) Product is intended for use with test and measuring circuits up to 600 VAC connected to the circuits/wiring outside of a building installation, including transmission lines. OVERVOLTAGE CATEGORY IV ENCLOSURE MATERIALS: LV-5: Outer grip ENSOFT SL 300-60A TPE, handle WONDERLITE PC-110 polycarbonite, tip Zytel ST801AHS nylon. LV-PT: ABS UL 94-HB PRINTED CIRCUIT BOARDS: FR-4 UL 94-V0 CLEANING INSTRUCTIONS - To clean the LV-5, LV-PT, LV-EH and LV-GS wipe with a damp cloth with water. Do not use harsh chemicals or solvents. DAMAGE - If you suspect any mechanical or electrical damage, do not use the LV-5 or LV-PT and arrange for repair by returning to the factory. CALIBRATION & TESTING - Regular calibration is not required. There is no calibration adjustment. REPAIRS - All repairs are performed at HD Electric Company. If any damage is found please contact HD Electric Company at 847-473-4980 to arrange for service. MANUFACTURING LOCATION HD Electric Company Waukegan, IL. 60085, USA 6

ACCESSORIES LV-EH EXTENSION HANDLE The LV-EH Extension Handle extends the reach of the LV-5 Detector. Insert the LV-5 into the open end of the LV-EH. Test the assembled LV-5 Detector and LV-EH Extension Handle before use with the LV-PT Tester, as shown on the right. If gloves will be worn while using the LV-EH, use those same gloves while performing this test. LV-GS GROUND SHIELD The LV-GS Ground Shield prevents nearby strong electric fields from affecting the LV-5 Detector. Use the LV-GS while using the LV-5 in or around high voltage substations, under overhead distribution or transmission lines or near other high voltage energized equipment. The LV-5 Detector is inserted into the open end of the LV-GS. Test the assembly of the LV-GS and LV-5 using the LV-PT Tester before each use. The alligator clip should be connected to a driven ground or other known good ground (not supplied). 7

LIMITED WARRANTY AND LIMITATION OF LIABILITY This warranty applies to all products sold by HD Electric Company (the "Products"); provided, however, that the term Products does not include any third party products purchased through HD Electric Company, for which no warranties are made (the "Third Party Products"). Third Party Products may be subject to a separate manufacturer's warranty; [should you have any question regarding whether a separate warranty applies, please contact HD Electric Company]. NOTICE: READ THIS LIMITATION OF WARRANTY AND LIABILITY BEFORE BUYING OR USING THE PRODUCTS CONTAINED HEREIN. It is impossible to eliminate all risks associated with the use of the Products. Risks of serious injury or death, including risks associated with electrocution, arcing and thermal burns, are inherent in work in and around energized electrical systems. Such risks arise from the wide variety of electrical systems and equipment to which Products may be applied, the manner of use or application, weather and environmental conditions or other unknown factors, all of which are beyond the control of HD Electric Company. HD Electric Company does not agree to be an insurer of these risks, and shall have no liability for any claims arising from such risks. WHEN YOU BUY OR USE THESE PRODUCTS, YOU AGREE TO ACCEPT THESE RISKS. HD Electric Company warrants to the original purchaser that the Products (excluding any third party products purchased through HD Electric Company, for which no warranties are made) will be free from defects in material and workmanship, under normal use and regular service, and preventative maintenance for a period of one (1) year (ten (10) years for HDE Capacitor Controls) from the date of shipment (the Warranty Period ). Should any failure to conform with this warranty be found during the Warranty Period, you must notify HD Electric Company of your claim within thirty (30) days of discovery, and within the Warranty Period. Your failure to give notice of claims of breach of warranty within the Warranty Period shall be deemed an absolute and unconditional waiver of claims for such defects. HD Electric Company will have no responsibility to honor claims received after the date the applicable Warranty Period expires. Upon notice of your claim, HD Electric Company will provide a return authorization number, and further instructions on how to return the product for service. You must follow HD Electric Company s instruction. You are responsible for all Product removal, handling, re-installation, and shipping (both to and from HD Electric Company). Products returned for repair, as well as repaired or replacement Products shall be sent postage / freight prepaid. After receipt of a product which HD Electric Company determines is defective, HD Electric will, at its option, either (1) repair (or authorize the repair of) the Product or (2) replace the Product, subject to the following: The Products are made using parts sourced from a variety of manufacturers. Due to the rapidly changing technology environment, parts may become obsolete / unavailable over time (end of life). In the event that a Product cannot be repaired or replaced due to unavailability of parts, HD Electric Company will use commercially reasonable efforts to obtain substitute parts or conduct work around design, but cannot guarantee its ability to do so. Items not found defective will be returned at your expense, or failing receipt of instruction from you on return of such items within five (5) business days of our notice to you that the product is not defective, HD Electric may dispose of the product at its discretion and with no liability to you. HD Electric Company s determination of defects is final. Products repaired or replaced during the Warranty Period shall be covered by the foregoing warranties for the remainder of the original Warranty Period or ninety (90) days from the date of delivery of the repaired or replaced Products, whichever is longer. LIMITATIONS: This warranty is void in the event of misuse, alteration, faulty installation, or misapplication of the product. This warranty does not cover failure of product or components due to any ACT OF NATURE; lightning, floods, hurricanes, tornadoes or any other such catastrophic events. HD Electric Company does not warrant any third party products or associated hardware or their performance or suitability for use and application. Such items are provided as-is. All repairs must be authorized by HD Electric Company. Unauthorized repairs will not be reimbursed under any circumstances. HD Electric Company is not required to make replacement or loaner equipment available while Products are being repaired or replaced, or to compensate you for any in/out labor charges or expenses associated with removal, handling or re-installation of the Products. TO THE MAXIMUM EXTENT PERMITTED BY LAW, THIS WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. HD ELECTRIC EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY AND NON-INFRINGEMENT. IN NO EVENT SHALL HD ELECTRIC COMPANY BE LIABLE FOR ANY INDIRECT, INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM THE USE OR HANDLING OF THESE PRODUCTS. THIS SHALL INCLUDE BUT, NOT LIMITED TO, LOST PROFITS OR REVENUE, LOSS OF USE OF THE PRODUCTS, COST OF SUBSTITUTE PRODUCTS, FACILITIES OR SERVICES, OR DOWNTIME. IN NO EVENT SHALL HD ELECTRIC COMPANY HAVE ANY LIABILITY FOR ANY THIRD PARTY PRODUCTS OR ASSOCIATED HARDWARE, OR CUSTOMER-OWNED SYSTEMS, EQUIPMENT OR SOFTWARE. HD Electric Company must have prompt notice of any claim so that an immediate product inspection and investigation can be made. Buyer and all users shall promptly notify HD Electric Company of any claims, whether based on contract, negligence, strict liability, or other tort or otherwise be barred from any remedy. HD Electric Company is committed to ongoing review and improvement of its product lines, and thus reserves the right to modify product design and specifications without notice. HD Electric Company products are available through HDE sales representatives worldwide. Printed in U.S.A. HD Electric Company 2016 Bulletin No. LV-5 IM-200b