Electron Microscopy Sciences

Similar documents
Contents. Desiccators. Ice Pan. Carboys. Flask Supports VDR-20/20U/20G/20UG, VDR-25/25U/25G/25UG, VDR-30/30U/30G/30UG

Methods of Desiccation

ISO-9001:2008 DESICCATORS CATALOG. Phone: Fax: Web:

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

OVENS Forced Convection Ovens. Economy Forced Convection Ovens. Vacuum Ovens.

Rycroft Supapac Plate Heat Exchangers

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

STERITITE INSTRUCTIONS FOR USE

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge

INSTALLATION AND OPERATION MANUAL

VWR symphony CO 2 INCUBATORS

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Table of Contents. English

OWNER S MANUAL. Solar Collector DELUXE

Elite. User s Information Manual. Elite and Elite VWH* All Models

AUC Cell Washer. User Manual

Buehler Cast N Vac 1000 Embedding System

AUBREY with MAJOLICA PORTO Operation / Installation manual

User s Guide for the SunDanzer BFRV55

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

SX-300 SX-500 SX-700

MC Series Gas-Fired Heating Appliance

JT-SB116JH-G-NA JT-SB116JH-W-NA

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

Ovens. General Applications. Forced Convection Ovens. Natural Convection Ovens. Vacuum Ovens. Clean Ovens, Class 100

Operation Manual R205BV, R209BV

Electric High-Pressure Washer - Operator s Manual

ASPIRE Laboratory Aspirator

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

Model K 240 plus Part No

Model K 5800 G Part No

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL

Model K 4400 G Part No High Pressure Washer

Model K 330 M Part No

Residential Gas Hybrid Water Heater

ELECTRIC POWERED PRESSURE WASHER

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

High Output Vacuum/Pressure Pump

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

Revolutionary Science RS-IF-202

K 3.97 M. Specifications or visit our website: In USA call: Part No

K Specifications. Max. Water Volume

Universal Fire Tube Boiler Wall Mount Models

Operating Instructions

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

Digital incubating/ refrigerating benchtop shakers

EDR Series. Model. Instruction Manual. Rev 5.0. Thank you for purchasing the EDR Auto Smart.

ICS PACIFIC. Installation Instructions & User Manual. G135L Medical Refrigerator

Desicators & Dry Cabinets

Laboratory Equipment Pty Ltd Instruction Manual Incubator IWJ Page 1

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

4-GALLON MOBILE PARTS WASHER

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

Beer Keg Dispenser User s Manual

READ AND SAVE THESE INSTRUCTIONS

Model K 520 M Part No

Checking the components Safety information Operating the product Other information

Countertop Refrigerator

Operating instructions Page 12. Wine storage cabinet WKt

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Bar Fridge USER MANUAL MB46W

Operating manual ELECTRIC ASPIRATOR 00) : 1) Page 1

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

Technology for Vacuum Systems. Instructions for use

User Manual. Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2

Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Tankless Water Heater

Vertical Gel Systems-Dual CAT NO: EPS-V0011 & EPS-V0012

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

BULL INSTRUCTION MANUAL. Model Number: BC-130 REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Model K 280 M Part No

1700 PSI Electric Pressure Washer

User s Information Manual

K Specifications. Max. Water Volume

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

Important Safeguards. Topic 2 SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS - FOR HOUSEHOLD USE ONLY 3

CR-1730R User s Manual

ACQUITY UPLC HT Column Heater Instructions

Owner s Manual. For Australian refrigerator models: N304.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Installation and User's Manual for Refrigerator Model SCR33

Operating instructions Wine storage cabinet Page 16

Requests for Care and Maintenance

USER MANUAL UN-200V / UN-200VH

BDASL101 BDASL102 BDASL103 BDASL201 BDASL202 BDASL Please have the model number available when you call.

ASSEMBLY & OPERATING INSTRUCTIONS

ELECTRIC ASH CAN Model: CVACASH500 Part No:

Requests for Daily Care and Maintenance

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Unity 180 Premium Whirlpool 180/80/62 cm

Transcription:

Electron Microscopy Sciences INSTRUCTIONAL MANUAL CAT. 71260-10 through 71260-17 Cabinet Style Lab Companion Vacuum Desiccators sgkcck@aol.com P.O. Box 550, 1560 Industry Road, Hatfield, PA 19440

Safety Symbols Defined Please read and follow all instructions and safety notices thoroughly before using the Cabinet Style Lab Companion Vacuum Desiccators. The following safety symbols are used throughout this Manual: DANGER CAUTION NOTICE This alert could cause serious or fatal injury if ignored. This alert could cause serious injury or property damage if ignored. This alert could cause operational problems if ignored. DANGER Ignoring these alerts could cause serious or fatal injury. Never install or use this unit in explosive atmospheres. Never install this unit near flammable or hazardous substances. Never disassemble, modify or repair this unit on your own. Doing so will void the warranty and may result in injuries or product damage. CAUTION Ignoring these alerts could cause serious injury or property damage. Read carefully all the warning labels on the unit. DO NOT remove or damage the warnings labels on the unit. ALWAYS use the molded-in handles to move unit. DO NOT move unit while in operation. DO NOT use unit in moist or wet atmosphere or where water leakage may occur. DO NOT place or store unit in direct sunlight or near any other heat sources. DO NOT use unit where metallic dust exists or in contaminated atmosphere. DO NOT expose inside of unit to organic solvents, corrosives gases, or moisture. DO NOT use chlorine bleach, ammonia, ammonia-based cleaners, abrasives or metal souring pads to clean unit. Use only a clean, soft, damp cloth or a sponge soaked in a dilute, neutral detergent or water to clean unit. Unpacking Desiccator Inspect the package and unit for any damage that may have occurred during shipping. Notify the carrier immediately if any damage has occurred. DO NOT use if damage has occurred. Also, check to make sure all items listed below are are included. If any are missing, please call Customer Service right away at 1.800. 523-5874. 1 Cabinet Unit 1 Vacuum Gauge Port Plug Perforated Shelves 1 3-Way Valve 1 Door Seal 1 Desiccant Tray 1 User Manual

Introduction & Features Thank you for purchasing a Cabinet Style Lab Companion Vacuum Desiccator. This unit is specially designed for high-performance, safety, ease-of-use and long-lasting durability. There are eight models to choose from; 11, 23, 35, and 45 liter internal volume in clear or UV blocking amber. All models feature: Vacuum sustainment of 1 Torr (133 Pa) vacuum for more than 72 hours at room temperature; stays gas-tight without a vacuum, allowing for reliable experiments over longer periods. the unique, unibody construction is a single molded piece (except for door) allows for maximum vacuum retention The polycarbonate body is shock-resistant, has a high tensile strength and, with a 360o transparent view, allows visual observation for any angle. The airtight door is equipped with a special latch that is easy to close under normal pressure and a greaseless vacuum seal that uses a high-quality silicon gasket that allows for quick airtight sealing and vacuum pressure. The 3-way valve that comes with the unit performs consistently with a uniform vacuum draw, vacuum release or gas exchange without having to connect/disconnect pump hoses. Up to four valves can be installed, with valve positioning being easily changes. Since all the units in the series have the same footprint, they are stackable to save lab space. Another space-saving feature is that the cabinet desiccators, being rectangular have a larger usable volume than round desiccators. Depending on unit size, up to 4-6 shelves can be used. (Depending on sized ordered, 2-3 shelves are included.) Accurate, built-in gauges are installed on the front door for ease of checking vacuum levels. A desiccant tray is also included. Cabinet Desiccator Diagrams Front Back Vacuum gauge Door Door latch Groove handle 3-Way valve Valve port plug Non-slip feet Door - Inside Inside & Outside Door seal Shelf rails Perforated Shelves Desiccant tray Stacking groove Groove handle Valve port plug Air inlet/ outlet nozzle

Applications The Cabinet Style Lab Companion Vacuum Desiccator is designed to be used in many applications. It is ideal for: Removing residual solvents or air bubbles Conducting low pressure experiment Cultivating anaerobic microbes Storing moisture-sensitive material such as anhydrides and other hygroscopic compounds as well as materials which are highly reactive with atmosphere Low pressure drying, which minimizes heat effect Drying/cooling stages of biological/materials/food/medical experiments where minimal air exposure and/or re-absorption of humidity is needed Placing and Moving the Desiccator NOTICE DO NOT expose unit to any heat source including direct sunlight. This unit is designed for indoor laboratory use only, under the following conditions: Ambient Temperature range: 5 to 40 o C (41 to 104 o F) Relative humidity: < 80% Altitude: 0 to 2,000m (6,562 ft.) Unit must be placed on a level surface. Unit must be at least 30 cm (approx. 3 ft.) away from other equipment When relocating the unit, use the built-in groove handles instead of holding on to other protruded parts such as the vacuum gauge or 3-Way valves Operating Conditions DO NOT form a vacuum when airtight containers are inside the unit. DO NOT autoclave this unit. When removing the port plug(s) in order to attach other equipment or additional 3-way valves, be sure use proper O-rings and nuts for tight sealing. DO NOT place high-temperature samples inside the unit. First, cool them thoroughly or DO NOT place them in direct contact with the interior of the unit, in order to avoid any damage to the interior. 3-Way Valve Open/Closed Positions When the handle aligns to a nozzle, that nozzle is open and the other nozzle is closed. When the handle is perpendicular (vertical) to both nozzles, both nozzles are closed. When facing the front of the desiccator, the 3-way valve is on the right side of the unit and, in the diagrams below, the nozzle closest to the front of the unit is labeled Front and the nozzle towards the back of the unit is labeled Rear. BOTH Nozzles CLOSED Rear Nozzle CLOSED Rear Nozzle OPEN Front Nozzle OPEN Front Nozzle CLOSED

Potential Hazards Moisture and chemicals from the samples may result in damages to the pump. When the unit is not forming a vacuum, keep the valve handle perpendicular to the nozzles The body of the unit will be damaged if there is direct contact with acetone, benzene, toluene, chloroform, cresol, sodium hydroxide, highly concentrated nitric or sulfuric acid, acetic acids, or strong chlorine-based solvents Strong acids or bases will also destroy the door seal, thereby causing malfunction of the unit. Directions for Vacuum Formation CAUTIONS Ignoring these alerts could cause serious injury or property damage. When forming or releasing a vacuum, turn the valve handle slowly to avoid rapid pressure change. If not, the stored samples can be damaged or dispersed When a vacuum is formed inside the unit, do not apply excessive force to the 3- way valves, the vacuum gauge, or any of their vicinities. Any damages caused by external forces can cause malfunction of the unit. DO NOT impact or drop the unit when a vacuum is formed inside. 1. When using the unit for drying purposes, fill the tray with desiccants and put it inside prior to operation. 2. Place samples inside the unit, firmly close the door by properly locking both latches. There will be an audible click sound when the latch is properly engaged. 3. Install a cold trap in front of the vacuum pump before forming a vacuum. 4. Connect the vacuum pump hose to one of the two nozzles of the 3-Way valve. 5. After vacuum pump activation, turn the valve handle towards the nozzle to open it; read the vacuum gauge to check whether the vacuum is forming properly. 6. Once pre-determined vacuum level is reached, turn the valve handle until it is perpendicular to the nozzle to close it and check the vacuum gauge whether there is any leakage. 7. To release the vacuum and return to normal atmosphere, slowly turn the valve handle towards the opposite nozzle. Trouble Shooting Guide for Vacuum Malfunction CAUSE Contaminated surface between door and body Damaged door gasket CORRECTIVE ACTION Thoroughly clean the surface with a soft cloth using diluted neutral detergent. Replace the gasket Unsuitable room temperature Check to see if the temperature is within the operating range. Misplaced or damaged 3-way valve Damaged vacuum gauge Check to see if the valve is properly set. If damaged, replace it with a new one. Replace the gauge.

Technical Specifications Material Internal Volume 11 L 23 L 35 L 45 L Body/Shelves 3-Way Valve, Latch, Desiccant Tray Vacuum Gasket Polycarbonate (PC) Polypropylene (PP) Silicone Vacuum Gauge Range Max. Permissible Nozzle Diameter Overall (W x D x H) 322 x 285 x 271 mm Analog 0 ~ -0.1 MPa 1.33 x 10-4 1Torr 0.95 mm 420 x 397 x 281 mm 420 x 397 x 381 mm 420 x 397 x 491 mm Dimension Door opening (W x H) 208 x 238 mm 295 x 245 mm 295 x 345 mm 295 x 445 mm Shelf (W x D x H) 202 x 204 x 6.5 mm 289 x 304 x 11 mm Desiccant Tray (W x D x H) 158 x 194 x 24 mm 218 x 268 x 268 mm Net Weight 4.2 kg 8.2 kg 10.8 kg 12.2 kg Shelves Number of Shelves (Standard/Maximum) 2/4 3/5 3/6 Max. Load/Shelf (kg) 3 5 UV Protection Range for the AMBER desiccators only UV A,B,C 100% (200~450nm)

Maintenance CAUTIONS DO NOT use chlorine bleach, ammonia-based cleaners, abrasives, organic solvents, or metal scouring pads when cleaning. Always use a soft cloth. If the unit is contaminated, wear chemicals-resistant gloves before cleaning. Regularly check the 3-way valves, the vacuum gauge, or any of their vicinities for any damage. Regularly check the vacuum seal and the surface where the body and the base are in contact and keep them always clean and undamaged. Make sure to clean the silicone gasket regularly using diluted neutral detergent. For thorough cleaning, detach the seal from the lid. Stacking Units The cubic vacuum desiccators are designed to be easily multi-stacked together by locking the feet of the unit into the stacking grooves located on the top surface of another unit. Storage If this unit is not to be used for an extended period of time, clean it with soft cloth, pack it for extra protection and store it in dry place. Disposing of Unit Disposing of the unit must be done in an environmentally responsible way if it has been potentially exposed to bio-agents or radioactive samples. Failure to follow stringent requirements for appropriate disposal may lead to actions against you and your organization. Follow the policies/procedures of your laboratory or organization for disposal of laboratory equipments and wastes. If necessary, contact local governing body for regulations regarding disposal of laboratory equipment.

Electron Microscopy Sciences For any questions or for ordering information, please contact Customer Service at 1-800-523-5874 Thank you for choosing! sgkcck@aol.com P.O. Box 550 1560 Industry Road Hatfield, PA 19440