The new standard. The best solar absorber tubes. The highest performance collector. Efficient modular assembly system

Similar documents
The new standard. The advanced solar absorber tube. The collector for every budget. Efficient modular installation system

2 Safety valve. 3 Pressure gauge. 4 Thermometer. 8 Ball valves

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

Solar. domestic hot water systems. Using the sun s energy to provide hot water

Heat Pumps and Public Swimming Pools, a Perfect Match

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors

Dedicate To be The Creator of High-quality Solar Energy Utility In The World PRODUCTS PROMOTION

Better Buildings By Design 2013 Building the Renewable Energy Ready Home Solar Thermal Lessons Learned and Results

PERFECT ORIENTATION ZONE 40 E 40 W GOOD GOOD ORIENTATION ZONE ORIENTATION ZONE

INDIRECT SYSTEM FOR FROST LOCATIONS

CHART PERUVIAN TECHNICAL STANDARDS

ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES

LOW IMPACT DEVELOPMENT GUIDANCE MANUAL AND LID WORKING GROUP ACTIVITIES. Powerpoint Templates. MS4 Statewide Stormwater Summit June 18, 2013

The perfect duo. ROTEX thermal store ROTEX solar system

Solar collectors. Speaker

Frequently Asked Questions Solar Collector G24

VENTAL V80 EXTERNAL LOUVRE BLINDS External Aluminium Louvre Blinds for Sunshading through Glazed Surfaces V80

Solar Heating Solutions

Heat Recovery Systems PTG, SWT Series.

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

SOLAR TECHNIQUE ATTACK SOLARTHERM, VAKUUMTHERM

SOLAR WATER HEATING DIRECT SYSTEM FOR FROST-FREE LOCATIONS DOMESTIC SOLAR WATER HEATERS, SOLAR COLLECTOR PANELS & SOLAR VACUUM TUBES

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Storing excess daytime solar energy to heat greenhouse at night!

SOLAR TUBE COLLECTORS

Dehumidification: Energy Efficiency Comparisons

GRAIN STORAGE AERATION PRESENTED BY: BRENT BLOEMENDAAL AERATION EXPERT

Heat recovery systems. For hot air and hot water applications.

So far, we have covered the basic concepts of heat transfer and properties.

The types BK 20 to BK 100 convincing power

TREATMENT AND CONDITIONING OF DISMANTLED MATERIAL AND OPERATION WASTE IN EWN OVERVIEW. Rohde, Mathias

QUALITY. Task Force. Shifting from Corn Drying to Corn Storage. Dirk E. Maier, Agricultural Engineering. Average Temperature F

Performance of Solar Water Heating Systems in the United States

COMMUNITY OPEN HOUSE. March 28, 2012

Maximizing Vine Crop production with Proper Environmental Control

Hot Water Generation for Commercial and Industrial Applications. Paul Marsden Specification Sales Manager

Solar Heat Pumps Domestic Range

Solar thermal systems

THE HEAT PUMP CHOICE OF PROFESSIONALS

SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS

Heat recovery. Heat recovery. Gas heating 280 up to 54,000 /year. Oil heating 284 up to 54,761 /year. Electrical power consumption

LIQUID CHILLER HEAT PUMP kw 30RB/30RQ - R410A. A Multi-Talented Performer

Cork County Energy Agency

The Remodeling Market

Thermal equalization is the obvious answer to the situation. But, how is "thermal equalization" achieved?

COMPACT TECHNOLOGY AND INNOVATION ENCOMPASSED IN A COMPACT FORM

Lifestyle Electric Thermal Radiator

Lifestyle Electric Thermal Radiator

WLAC Facilities Committee Meeting. September 18, 2017

Remodeling Market. Kermit Baker. Remodeling Futures Conference November 9, Harvard University JOINT CENTER FOR HOUSING STUDIES

Compact and efficient.

Glass Roof Upgrades. The Pilkington Activ Range. The clear choice for conservatories and orangeries.

Solar technology VITOSOL 100-F VITOSOL 200-F VITOSOL 200-T

The Ed Roberts Campus Berkeley, CA

The Ultimate Solution for Electric Central Heating. Fusion. Comet

Run On Sun Australia Pty Ltd. ABN No P.O Box 34 Deepwater, N.S.W Ph

The sunny side up. NARVA vacuum tubes. high performance. long lifetime. intrinsic safety heat pipe

Compact and efficient

Daikin Altherma Selection Report

OFFICINE MINUTE VILLORBA - TREVISO

THREADING TURNING MILLING BROACHING RUBBING HONING SPINNING LAPPING HOBBING DRILLING

Hot water circulation system WZS 100

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

Kills bills. How Vaillant technologies reduce home heating bills

COMPRESSORS. Heat recovery. For hot air and hot water applications.

GEA Air Handling Units Modular configuration. Integrated refrigeration with optimized energy efficiency GEA CAIRplus.

Heating and Hot Water

Solar Combi Systems Trans-solar Workshop Romania, Bucurest

Ultra Low Cost Solar Water Heater. Concept Generation and Selection Document

SUPERTHAL. Heating Modules for Customized Furnaces and Heaters

Equipment ATA 12 April 2016

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81)

SAFETY AND ENVIRONMENTAL EDUCATION FOR DEVELOPMENT SEED

Level 6 Using Physics: Investigate how physics knowledge is used in a technological application.

Sweden s leading air source heat pump

The complete heating system

ELIMINATE THE BIGGEST ENERGY CULPRIT

BOA-Systronic. KSB Know-how, Volume 2

ZEMOS SOLAR ENERGY POWERED WATER BOILERS

Adelaide Homes Design Guide 4 - Winter warming

Gas condensing boiler (wall mounted) TopGas

Development of TRNSYS Models for Predicting the Performance of Water-in-Glass Evacuated Tube Solar Water Heaters in Australia

Transfer of Thermal Energy

Go Solar. Go Green. About YogiSun

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

DK-HEAT RECOVERY FOR TRANSCRITICAL CO 2 REFRIGERATION SYSTEMS

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

LATENTO Solar system. All-year solar systems Plastic storage tanks Vacuum tube collectors Solar - regulation Accessories

EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

Solar Thermal Planning Worksheet Date: / /

INDEX. Ⅰ. Company Overview. Ⅱ. Business Line. Ⅲ. Business Planning. Ⅳ. Appending - Certificates

Water Heater Innovations Marathon Water Heater Limited Warranty Policies & Procedures

Olymp Werk GmbH c/o Grouped Renewables Ltd. PO Box 7180, Montrose DD10 0WX Tel: +44 (0) Web:

Technical documentation Solar technology

Design and Performance Analysis of One Ended Evacuated Tubes at Different Air Flow Rates Nitin Panwar 1

SOLAR HOT WATER AND HEAT PUMP BOOSTER ENERGY CALCULATION METHODOLOGY

Annual environmental performance evaluation of light and heat in daylight harvesting systems using Radiance and NewHASP

Solar Technology. CPC and Sunnyline. collectors. makes you independent. Pelletskessel.

Transcription:

The new standard The best solar absorber tubes The highest performance collector Efficient modular assembly system Intelligent OPC system technology

1 The new standard OPC the new standard in the utilization of thermal solar energy Pioneer of 360 absorber technology recognized 10 years ago the advantages yielded by spatially designed absorbers. That 360 absorber vacuum tube technology was awarded the gold medal in 1987 at the international inventor fair in Geneva was the logical consequence of an ingenious conversion. OPC collectors distinguish themselves through maximum output at low structural mass. It has been proven that only 360 tube collectors achieve highest energy yields throughout the entire service life. With OPC collectors, loss of vacuum, i.e. power loss, is a thing of the past. OPC collectors are developed and produced in Switzerland. Quality is oriented to the Euro quality standard (Euro Norm). At the International Fair of Installation Technology and Industry (March 28 31 2006) in Poznan (Poland) OPC15 Edition EU21 has won the gold medal for a technical innovative development AMK SOLAC Systems AG provides optimized installation systems for any possible use (slanted roof, flat roof, facades, interlocked metal roofing, Eternit roofing, installation of the collectors in the open). In this way small as well as large facilities are able to be realized simply, without problem and costefficiently. Optimization also pertains to existing objects for which a solar facility is later installed or for which an existing facility is to be replaced or expanded. As regards output, quality, ease of installation and flexibility, the OPC collectors represent a new standard. OPC collector technology is protected by patent. optimized parabolic collector Application areas for AMK collectors include < Standard preparation of hot water < Heating support with high degrees of coverage < Process heat generation < Cold production for air-conditioning aided by absorption refrigeration technology < For single occupancy houses, multifamily residences, hotels, industrial and commercial premises eading through experience

2 The best solar absorber tubes The tubes for any weather the year round Our 360 absorber tube utilizes solar energy the year round in the most efficient way and provide the house with free energy even in gloomy weather. Compared with other collectors, the absorbers, thanks to the 360 technology, absorb direct and diffuse radiation in a much greater mass. In concert with the vacuum insulation, heretofore unknown rates of efficiency have been achieved with our 360 absorber tubes. Even at sub-zero temperatures this construction prevents heat loss. The vacuum between the mutually fused glass tubes cannot be destroyed. The insulating effect remains unchanged. This enables the 360 absorber tubes to provide constantly high performance data for the entire life of the tube. From the sun to the 360 absorber tube... Solar radiation direct and diffuse permeates the outer glass tube and is captured on the outside of the inner glass tube by the 9-fold coated black absorber. Technical OPC OPC Data 10 15 length: 1700 1700 mm width: 850 1250 mm height (incl. frame): 97 97 mm gross surface: 1.45 2.13 m 2 active absorber surface 360 : 1.67 2.50 m 2 aperture surface: 1.15 1.72 m 2 weight: 32 45 kg absorber/glass: 360 360 borosilicate 3.3 frame: aluminium coating: 9-fold aluminium nitrite/alu/steel connections: 6 x 3/4" total capacity: 2.1 3.1 liter allowed working pressure: 10 10 bar flow rate recommended: 0.8 1.1 l/min/module Double plus, higher yield of solar energy for the whole year Vacuum insulation and the large 360 absorber surface take care of 100% solar energy coverage in the transition periods as well. Inefficient heating systems need not be run. When it gets down to it, this combination brings high-utility energy from the sun at sub-zero temperatures in winter and when overcast or raining. 100% solar share for hot water/heating...and from the tube to the solar cycle The 360 absorber tube is completely separate from the solar cycle. The captured energy is transmitted to the flush-contact aluminium shield and the copper lines filled with heat transfer medium. Very large contact surfaces assure the fastest transfer of energy. 100 90 80 70 60 50 40 30 20 10 energy requirement OPC collectors + + flat collectors Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Added value from OPC collectors Adva < The absorber is a uniform body of glass. No metal-glass compounds. < Top vacuum capacity is maintained for the whole service life. < All round absorber for the greatest possible energy-collecting surface; utilizes up to 80% of the diffuse radiation. < A consistently high rate of efficiency is maintained for the service life because the insulation and the absorber layer do not break down with time. < The tube can only be damaged mechanically. Even a tube with vacuum loss which doesn t exhibit any visible glass breakage is immediately recognizable by the white, water vapor cloudiness. A gradual decrease in yield is impossible. < 9-fold aluminium nitrite coating

3 The highest performance collector Minimum energy loss with integrated hydraulic system and vacuum insulation The patented, fully integrated 3/4 collector hydraulics minimize energy loss. No external lines, in- and outlet for the solar water cycle on one side. The 3/4 hydraulics make the largest possible facilities possible with the least loss of pressure. The fully integrated 3/4 collector hydraulics assures full flexibility in the hydraulic system. Easy connection under conditions of pressure equilibrium. Flow and backflow connection either on same side or on alternate sides. Line loss is minimized with the OPC because the lines are already integrated into the collector. 3/4 three-tube system for facilities large and small lowest pressure loss preinstalled sensor socket Integrated collector hydraulics no external lines best possible insulation Tichelmann principle integrated Shortest possible installation time one-sided connection one-sided in-/outlet only one roof penetration Maximum energy recovery with 360 absorber tube and parabolic reflector OPC s optimized tube spacing and coordinated reflector enable the greatest exploitation of energy from direct and indirect solar radiation. No irradiation problem long daily periods of energy use The correct collector geometry of tube spacing and reflector makes it possible. From early morning to late afternoon the absorber is always optimally irradiated. And the optimized parabolic reflector enables the reflection of direct and indirect solar radiation to the back of the absorber tube. ntages < Maximum yield at small dimensions < Certified in accordance with yield and quality < High tube density and reflector technology < No optical linear contraction due to oblique irradiation mornings and afternoons < High year-round utilization ratio < High daily utilization ratio < High utilization ratio for the entire service life < High material quality and workmanship: aluminium, borosilicate glass 3.3 / aluminium nitrite-coated, copper, steel EPDM/silicon, fibre glass reinforced plastic, glass wool < Usable for water heating, heating support, process heat, cold production < Collector connection with standard tools, no soldering, no welding < Flexible system sizes, from small- to largescale with guaranteed high performance < All materials recyclable < Suitable for new building, renovation or backup for existing facilities < Solar calculation program: Polysun, T-Sol

4 Efficient modular assembly system OPC the collector with the cost-saving, simple installation A roof is a roof! That s why OPC collectors are not built into the roof but on it! OPC collectors don t win you over through top quality alone, but also through top design. With a height of only nine centimeters they look at the same time elegant and functional on every roof. Even large OPC collector fields need only be installed on one side; in this way the roof surface only has to be penetrated at one single spot for the lines into the house. No external lines on the roof are normally necessary. OPC naturally has a mounting system for flat roofs as well, and also for Eternit and wall mounting. For a flat roof, the OPC collector becomes a carrier channel with flexible angle adjustment possibilities; faster installation than for a tile roof is even possible. Multifunctional gliding channel sections make installation of the OPC collectors extremely simple. At the same time the hydraulic connection to screwed down with standard tools. No soldering, no welding, no special parts. All parts and procedures are self-explanatory, and the flexible the collectors is also taken into account. Newly developed high-temperature and pressure-proof steel compensators are installation technique practically makes the need for the installer to take measurements unnecessary. < Mounting the collectors for water heating is possible in less than half-a-day < Rule of thumb for warm water facilities: Advantages 1 person = 10 tubes = 100 l reservoir < Shortest possible installation time < No constructional changes necessary < Removable at any time < Self-explanatory installation technique < Standard tools can be used < Subsequent functionality already guaranteed at installation < Light, very easy to handle materials < Modular, flexible installation technique

5 Intelligent OPC system technology The OPC collector brings more advantages to the user Our OPC collectors, when properly integrated into the house technology, provide energetic high efficiency. Burners and heating systems are relieved by the OPC collectors, they last longer, are less prone to disturbances and need less servicing, because the inefficient stop-and-go running of the burner is no more. More financial benefits on all levels: lower operating costs and higher energy savings, longer service life and therefore less investments. floor heating CW WW warm cold Oil/gas heating and OPC collectors Switch off the oil/gas burner for half a year! In the transition periods and in winter the burner will then run much more efficiently. Service expenditures, investments and oil/gas consumption sink. expansion tank expansion tank Wood heating and OPC collectors The ideal system combination: With wood heating, a useful reservoir for solar energy is already on hand. Moreover, firewood consumption sinks sharply, which also simplifies operations. Heat pumps and OPC collectors Solar facilities and heat pumps make even better use of the electrical energy. In summer the heat pump isn t necessary, and in winter it is reinforced by the solar facility. That pays doubly. And your OPC combination? OPC collectors optimize your household technology. They can be combined with all conventional and new regenerative energy systems, e.g. also with controlled ventilation systems. Take advantage of the benefits of OPC system combinations! < High savings in fossil fuels by optimizing the solar facility < Much lower maintenance costs for the burner through longer running times < Optimized burner run times enable the burner to last longer < OPC solar facilities are suitable for new buildings and energy systems redevelopment < OPC solar facilities are becoming the main item in modern household technology < OPC solar facilities can be combined with all new technologies into systems with more customer utility < OPC solar systems take care of the solar energy supply the year round; higher facility utilization ratio thanks to the most advanced of technologies Advantages AMK-SOLAC Systems AG Bahnweg Nord 16 CH-9475 Sevelen / SG Phone: +41 81 750 17 17 Fax: +41 81 750 17 18 www.amk-solac.com The manufacturer reserves the right to make changes to the product at any time that serve technical progress. MAXIMUS General Services Maracineni DN2 / E85 Nr.134, Buzau, Romania Tel: +4(0) 745 021 755, +4(0) 745 047 317 www.maximusenergy.ro OPCFlyerENG050606