Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Similar documents
Frost Protection Thermostat

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Duct Temperature Sensors

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Frost Units for air temperature monitoring

Electronic timeswitch

1592P01. for liquids in piping DN

Use. For 2-pipe fan coils

Room Temperature Controllers

Semi flush-mount room thermostats

Room thermostat with 24-hour time switch and large LCD

Room thermostats with LCD RDD100..

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Room Temperature Sensors

Wireless room thermostat with LCD

Room Temperature Controller

RVL479. Heating Controller. for use with a partner unit

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Flush-mounted room thermostat

Wall-mounted room thermostat with LCD

Duct Temperature Sensors

Room thermostat with independent DHW control

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Flush-mounted room thermostats

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

for relative humidity and temperature

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Room thermostat with Auto Timer, independent DHW

QAW70. Room Unit. Building Technologies. for use with heating controllers

Output module (230 V)

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

FDM273 Radio manual call point Mounting

Heating Element. Building Technologies HVAC Products

RAB21 RAB21.1. For two-pipe fan coils

Mimic display driver, LED ribbon cable

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Immersion Temperature Controller

Multi line separator module

Room thermostat with Auto Timer, Option External Input

Input module, input/output modules

Room thermostat with Auto Timer, Option External Input

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Room Temperature Sensors

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

for relative humidity and temperature

Series A28 Two stage Thermostats. Feature and Benefits

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Thermostatic Actuators

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

DT1101A / DT1102A / DO110xA Automatic fire detectors

FDCL221-M Multi line separator module

DM1131 / DM1133 / DM1134 Manual call points

Input module, input/output module

DOW1171 / DCW1151 Radio fire detection system

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Room thermostat with Auto Timer, Option External Input

Radio fire detection system

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Temperature Sensor TRG Original Installation Instructions English

C Note! LGI16... Burner Controls. Building Technologies

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

DF1151-Ex Infrared flame detector

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

ASA linear smoke detector

Self-learning Room Temperature Controller

Capillary & Bulb Thermostatic Control & Fail-Safe Limit

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

FDCW241 Radio gateway Mounting

Semi flush-mount room thermostat

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

REA22 Room Temperature Controller

FDOOT221, FDO221, FDT221

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

for relative humidity and temperature with calibration certificates

Room Air Quality Sensors

THERMASREG TR 040 THERMASREG TR 060

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

y Small dimensions. Easy to install in refrigerated counters or cold rooms

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

OH720, OP720, HI720, HI722

Duct Air Quality Sensors

Interbases. Sinteso FDSB221, FDSB228, FDSB229

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDBZ290 Air sampling smoke detection kit

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

Control Products & Systems OEM

Room Temperature Sensor

Transcription:

1 202 Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597 RAK-TW.1..H RAK-TW.1..H.. Use Function Changeover switch (S.P.D.T.) 2-position thermal reset limit thermostat with single-pole changeover microswitch Switching capacity contact connection 1-2: 16 (2.5) A, AC 250 V contact connection 1-3: 6 (2.5) A, AC 250 V Time constant conforming to DIN EN 14597 3 mounting choices: pipe, pocket or wall mounting Adjusted switch-off temperature can be checked through the viewing window in the housing IP43 and IP65 protection class available Push-in terminals for fast installation Typical applications: Heat generation plant (supervision of the boiler temperature; mandatory in open heating systems) For general use in heating, ventilation and air conditioning plant When the adjusted switch-off temperature is reached on rising temperature, contact connection 1-2 changes over to contact connection 1-3. When the temperature of the medium falls by the value of the switching differential, the thermal reset limit thermostat (TW) reverts to contact connection 1-2. If the probe has cooled down to a temperature below approx. -20 C, the control current circuit opens, however, automatically closes again, when the temperature rises. CE1N1202en 2017-10-25 Building Technologies

Type summary Product No. Stock number Degree of protection Temperature setting range Capillary tube length Scope of delivery Pocket length 1) RAK-TW.1000HB S55700-P115 IP65 15...95 C Pocket (for 100 mm RAK-TW.1200HP S55700-P118 IP65 40...120 C RAK.B and P) / Clamping band for 100 mm RAK-TW.1200B-H S55700-P117 IP43 40...120 C max. pipe dia. 100 mm RAK-TW.1000S-H S55700-P116 IP43 15...95 C 700 mm 100 mm (for RAK B) / Cable ---- RAK-TW.1200S-H S55700-P119 IP43 40...120 C gland M16x1.5 mm / Mounting instructions ---- 1) Pocket ALT-SB100, brass, PN10 Accessories Ordering Refer to Data Sheets N1193 and N1194. When ordering, please give type reference according to Type summary (standard set). If the accessories required are not those included in the standard set, they can be ordered separately according to the type references given in Data Sheets N1193 and N1194. Mechanical design Housing Notes The base of the thermostat is made of PC (reinforced) and is designed for pipe, pocket or wall mounting; the electromechanical thermal reset limit thermostat uses a capillary type sensing element. The cover is made of PC and has a viewing window. The cable gland is M16x1.5 mm. The PC plastic is especially designed to be flame resistant, UV protected and flexible against high temperatures and tough against chemical and biological impacts. Mounting aid Mounting location Pipe mounting Pocket mounting Wall mounting with sensing element in the pocket Temperature setting Wiring Max. AC 250 V Installation Instructions are enclosed in the package. It must be ensured that there is sufficient clearance above the thermostat for seeing through the viewing window, for adjusting the limit temperature and for removing and replacing the thermostat, if required. The clamping band should be properly tightened to ensure the entire length of the sensing element is in close contact with the pipe s surface. Mount the pocket and adjust the hexagon as required. Immerse the capillary sensing element in the pocket and secure the base to the pocket by means of the screw. To prepare for wall mounting, knock out the fixing holes in the housing and pull out the capillary tube until the required length is reached. After immersing the capillary sensing element in the pocket, secure it with a clamp (mounting accessories). The limit temperature must be adjusted only by qualified personnel. The appliance must be wired by the installer only. The cables used must meet the insulation requirements for mains voltage. Wire the thermostat according to the connection diagram and in compliance with local regulations. Caution: prior to opening the housing, disconnect the thermostat from the mains supply. Earth connections must be made in compliance with the regulations. 2/6

Disposal The devices are considered electronics devices for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic waste. Dispose of the device via the channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Technical data Switching mechanism Directives and Standards Environmental conditions Calibration Switching capacity Nominal voltage Nominal current I (I M ) contact connection 1-2 contact connection 1-3 External fuse Life expectancy at nominal rating AC 24 250 V 0.1...16 (2.5) A 0.1 6 (2.5) A 16 A min. 100'000 switching cycles Safety class I to EN 60 730 Degree of protection: IP43 and IP65 to EN 60 529 Temperature setting range (with tool) RAK-TW.1000HB RAK-TW.1200HP RAK-TW.1200B-H RAK-TW.1000S-H RAK-TW.1200S-H Thermal switching differential 15...95 C 40...120 C 40...120 C 15...95 C 40...120 C 6 K (range dependent) Product standard EN 60730-x DIN EN 14597 (TW1197) 1) EU Conformity (CE) CE1T1206xx 1) Radio interference protection click rate N 5 to EN 55 014 Operation Max. temperature on bulb Ambient temperature at the housing Humidity Mechanism Storage and transport Ambient temperature Humidity class 3K5 to IEC 60 721-3-3 switch-off temperature + 25 K max. 80 C (T80) < 95 % r.h. class 3M2 to IEC 60 721-3-3 class 2K3 to IEC 60 721-3-2-25 +70 C < 95 % r.h. Max. temperature socket 125 C Degree of pollution 2 to EN 60 730 Controlled medium Water, oil, air Influence of the ambient temperature -0.25 C/ C Calibration temperature 80 C Manufacturing deviation ±3 C Drift after life expectancy < ±5 % Calibrated for ambient temperature at the switching mechanism and capillary tube 22 C to DIN EN 14597 Time constant in: water oil air <45 s to DIN EN 14597 <60 s to DIN EN 14597 <120 s to DIN EN 14597 3/6

Connections General data Electrical connections Earth connection Cable gland External wiring flexible cord Housing colors Dimensions of sensing element Capillary length Min. bending radius of capillary Construction Carrier of switching mechanism Capillary tube and sensing element Diaphragm Weight of standard set: RAK...B RAK...S Push In 2) terminals for wires 6 x 0.75...2.5 mm² Push In 2) terminals for wires 2 x 0.75...2.5 mm² M16 x 1.5 mm designed to be connected with unprepared conductors or prepared conductors, e.g. ferrules base RAL 7001 (dark-grey) cover RAL 7035 (light-grey) 6.5 mm dia. x 65 mm 700 mm R min. = 5 mm plastic copper stainless steel 0.33 kg 0.27 kg 1) The documents can be downloaded from http://siemens.com/bt/download. 2) Push In is a patented connection technology designed by Weidmüller, Germany s leading manufacturer of electrical connection technologies. Connection diagram < 1186A01 1 3 2 E 3 E 2 L1 N Dimensions 4/6

5/6

Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 58-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2005 Delivery and technical specifications subject to change 6/6