Presentation On Industrial Boiler Operation And Maintenance

Similar documents
Boiler. Fire tube Boiler:

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

AIM OF THE EXPERIMENT:- Study of boilers (fire tube, water tube) APPARATUS REQUIRED: - SL.NO NAME OF THE APPARATUS SPECIFICATION QUANTITY 01 Fire tube

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202

BASIC BOILERS NAME :- DATE :-

MODEL ANSWER FOR ELEMENTS OF MECH.ENGG.(17413) 1) steam boiler- It is a closed vessel in which steam is produced from water by combustion of fuel.

Adca Training. Part 2

Boiler Basics. Design and operation

CHAPTER 2: PROPERTIES OF STEAM AND STEAM POWER

THERMAL ENGINEERING & GAS DYNAMICS ME-6002

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Diocese of Cleveland Facilities Services Corporation

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

Solution of I Mid Term Steam Engineering 6ME5A

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

Math & Physics. Complete combustion requires an Air-FuelRatio of 14.7 to 1 for combustion.

Development of Boiler Design

DH-Direct Fired Poultry Farm Diesel Heater

WHE 2.24 / WHE 2.24 FF

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

1. GENERAL SAFETY RULES

POWER VENTER. Model: PVE Series

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

ST 40 Oil Burner. Installation & Maintenance Manual

User s Information Manual

Baxi Maxflow Combi FS

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

DIRECTIVE NO: D-B

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

Steam Fundamentals. (in heating & processing applications)

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

Steam and Gas Power Systems Prof. Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee

INSTALLATION AND OPERATION MANUAL

USERS MANUAL FOR GAS BOILERS

Boiler Mountings. Engr. Omar Sadath, Maritme Lecturer & Trainer, Bangladesh

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

Steam and Gas Power Systems Prof. Ravi Kumar Department of Mechanical and Industrial Engineering Indian Institute of Technology - Roorkee

PVE SERIES POWER VENTER SYSTEM MANUAL

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

GOLD. User s Information Manual. Water Boiler Series 4

User s Information Manual

INSTRUCTION MANUAL FOR OIL BURNER MODELS

SULPHUR RECOVERY UNIT

Low pressure boiler* inspection and maintenance

Baxi Maxflow Combi WM

Owner s Guide Installation & Operation

SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.)

Rapid Response Series (RR e & RR i) OPERATING MANUAL

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

User s Information Manual

Operating instructions

User s Information Manual

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Installation & Maintenance Manual

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

ToThePOINT. Best Practices. Best Practice No. 1: Have your boiler inspected regularly by an authorized inspection agency. LOSS CONTROL SERVICES

RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS

EL195DFE SERIES GAS FURNACE WARNING

TECHNICAL INSTRUCTIONS USE AND MAINTENANCE

INSTRUCTION MANUAL FOR OIL BURNER MODELS

User s Information Manual

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM

User s Information Manual

Knowledge Objectives (2 of 2) Fuel Gas Systems. Skills Objectives. Introduction. Fuel Gas Systems (1 of 6) 12/20/2013

ML180UH SERIES GAS FURNACE WARNING WARNING

Chapter 2.3: Steam System

G61MPV SERIES GAS FURNACE WARNING

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

EL195UH SERIES GAS FURNACE WARNING

CRU-S Series Stainless Steel Condensate Recovery Unit

F900 SERIES BOILING PAN G9781. User, installation and servicing instructions. Read these instructions before use T REV.

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

WARNING FIRE OR EXPLOSION HAZARD.

Carbon Monoxide Safety Information

GWC. User s Information Manual. Gas-Fired Water Boilers. Model

TECHNICAL MANUAL ASGX

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

Document Code: 1 (15) Issuing date: Status:

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

User s Information Manual

DEVRON SERIES MULTI FUEL FIRED GASIFICATION HOT WATER BOILERS DEVRON-30, DEVRON-40 OPERATION, USE AND MAINTENANCE MANUAL

Good Ideas For Propane Safety

Operating instructions

User s Information Manual

Incident Summary (II )

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Assessment Schedule - TS.6

Eclipse Self-Check UV Scanner

Transcription:

Presentation On Industrial Boiler Operation And Maintenance Supervised By: Engr. Poresh Kanti Das GM-MAL RIP, Mulgoan, Kaligonj, Gajipur

Boiler fundamental. Assessment On Heat recovery Boiler. Boiler Operation. Boiler Maintenance Boilers risk factors & Safety Operators gap on operation system of boiler. Boiler license and its operational gap

Boiler: A boiler is an enclosed vessel made of steel in which water is heated by combustion of flue gases or exhaust and circulated, either as hot water, steam, or superheated steam for the purpose of heating, powering, and/or producing electricity. Generally Boiler Two Types- 1. Fire tube or smoke tube boiler 2. Water tube boiler The steam boiler may also be classified according to the source of heat supplied for producing steam. These source may be the combustion of solid, liquid or gaseous fuel, hot waste gas as by-products of others plant. In our Group, normally we use fire tube boiler- 1. Gas/ diesel boiler 2. EGB(Exhaust Gas Boiler)/ HR boiler 3. Rice husk fired boiler

Fire tube boiler: In fire tube steam boilers, the flames and hot gases, pass through the tubes which are surrounded by water. Fire tube boilers are generally used for relatively small steam capacities and low to medium steam pressure. As a guideline fire tube boilers are completive for steam rates up to 12000kg/h and pressures up to 18 kg/cm².fire tube boilers are available for operation with oil, gas or solid fuel. Example: Cochran boiler, Locomotive boiler, Scotch marine boiler, Velcon boiler, simple vertical boiler. In our factory we use 3 pass gas boiler & single pas HR boiler.

Water tube boiler: In Water tube boilers, the water is contained inside the tubes which are surrounded by flames and hot gases from outside. The steam capacity of boiler range 4500-120000kg/h at very high pressure Example: Babcock and Wilcox boiler, Stirling boiler, La Mont boiler, Benson boiler.

EGB: An Exhaust Gas Boiler is a type of heat recovering system which allows the exhaust heat of the main engine, such as hot flue gases from a DG/GG to produce steam while going out in the atmosphere.

Advantages Of EGB: 1. Decrease the costs of fuel and energy consumption needed for that process. 2. Thermal and air pollution will dramatically decrease since less flue gases of high temperature are emitted from the plant. 3. As Fuel consumption reduces so the control and security equipment for handling the fuel decreases. 4. Reduction in equipment sizes means another reduction in the energy fed to those systems like filters, fans,...etc. Disadvantages of EGB: 1. The capital cost to implement a waste heat recovery system may outweigh the benefit gained in heat recovered. 2. Often waste heat is of low quality (temperature). Heat exchangers tend to be larger to recover significant quantities which increases capital cost. 3. Need to shutdown the exhaust generating like GG or DG unit which create major breakdown of plant.

Quality: Higher temperatures = Higher quality = Lower heat recovery costs Quantity: The amount of recoverable heat can be calculated as: Q = V x x Cp x T Q = heat content in kcal V = the flow rate of the substance in m3/hr = density of the flue gas in kg/m3 Cp = the specific heat of the substance in kcal/kg oc T = the temperature difference in oc Cp (Specific heat of flue gas) = 0.24 kcal/kg/oc

Money saving from Heat Recovery: Saving Money by recovering heat from Generator Exhaust Gas Heat saving (Q) is: Q = m x Cp x (kcal/hr) Where, m= V x =Exhaust gas flow rate, kg/hr Cp= (Specific heat of flue gas) = 0.24 T= Exhaust inlet- Exhaust outlet= 530-180 = 0.49 ( exhaust inlet 530 C and out let 180 C) Equivalent Oil saving=q/calorific value of 1 ltr oil, Ltr Money saving/ yr=equivalent Oil saving(ltr) x price of fuel(tk)x 6000 hr., Tk

1. Boiler shell: It is made up of steel plates bent into cylindrical from reverted or welded together. 2. Combustion chamber: It is the space generally below the boiler shell, meant for burning fuel in order to produce steam from the water contained in the shell. 3. Gate: It is the platform in the combustion chamber, upon which fuel is burnt. The surface are of the gate over which the fire takes place is called gate surface. 4. Furnace: It is the space above the gate and the boiler shell in which the fuel is actually burnt the furnace is also called fire box. 5. Heating surface: It is that part of boiler surface which exposed to the fire. 6. Mountings: There are the fittings which are mounted on the boiler for its proper functioning. A boiler cannot function safely without mountings. 7. Accessories: These are the devices which form an integral part of a boiler but are not mounted on it. It may be noted that the accessories help in controlling and running the boiler efficiency

.

(a) Water indicator: It is an important fitting which indicate the water level inside the boiler. (b) Pressure gauge: A pressure gauge is used to measure the pressure of the steam boiler. (c) Safety valves: There are the devices attached to the steam chest for preventing explosions due to excessive internal pressure of steam.

(d) Stop valve: It is the largest valve on the steam boiler. It is used to control the flow of steam from boiler to the main steam pipe. (e) Blow off cock: It is fitted to the bottom of a boiler drum and Its function is to empty the boiler whenever required and to boiler bottom discharge the mud, scale or sediments. (f) Feed check valve: It is a non-return valve fitted to a screwed spindle to regulate the lift.

(g) Fusible plug: It is fitted to the crown plate of the furnace or the fire. Its object is to put off the fire in the furnace of the boiler when the level of water in the boiler falls to an unsafe limit and thus avoids the implosion which may take place due to overheating of the furnace plate. (h) Blow down valve: It is fitted to the lower side of the boiler. Its function is to reduce the impurities of the boiler.

(a) Feed pump: A feed pump needed to deliver water to the boiler. The pressure of feed water is 20% more than that in the boiler. The feed pump may be classified as simplex, duplex, triplex pumps according to the number of pump of cylinder. (b) Super heater: A super heater is an important device of a steam generating unit. Its purpose is to increase the temperature of saturated steam without raising its pressure. It is generally an integral part of a boiler and is placed in the path of hot flue gases from the fluency. The heat given up by these flue gases is used in super heating the steam.

(c) Economizer: An Economizer preheater is used to recover heat from the exhaust flue gases. It is installed between the economizer and chimney. The air required for the purpose of combustion is drawn through the air pre-heater where its temperature is raised. There is an increase of about 2% in the boiler efficiency for each 35-40% raise in temperature of air.

The type & size of a boiler depends on following factors- The power required Working Pressure required as per use point Required Steam flow rate. Water available. The type of fuel to be used.

Best Practices for Boiler operation SOP Daily Check List Log Sheet Water Treatment Boiler Blow down

As with all systems where water is heated there will be a potential for scaling. This can lead to a loss of efficiency or, in extreme cases, premature failure of the boiler due to either scale build-up on the internal surfaces or debris from corrosion collecting in the bottom of the boiler. Water quality within the boiler must be maintained to reduce the risk of overheating, corrosion, water carryover causing destructive water hammer and build-up of solids. Water Quality can be maintained by 1. Water treatment by softener. 2. Adding chemicals.

Following water parameter needed to maintain SN Particular Soft water from WTP(std) Feed water (std) Blow down water(std) Remarks 1 TDS 150 ppm 105-180 ppm 3500 ppm 2 Hardness 5.0 ppm 5.0 ppm 0.00 ppm 3 PH 6.5-7.5 7.5-9.5 (10.5-12) Operator must ensure no existence of salt with feed water by mouth feel test after every regeneration which is also major cause of boiler tube damage.

SN Chemical Name Qty Remarks 1 Ion exchange 2586 500gm All mix together and 2 Ion Exchange 1155 200gm dosing accordingly 3 Water 60 ltr INDION 2586 & 1155 : is designed to prevent scale and corrosion on water surfaces of medium and low pressure boilers using un-softened feed water. It is a blend of chemical softening agents, sludge conditioners and oxygen scavengers which protect the feed lines and the boiler from scale and corrosion.

Blowing down the boiler to maintain these TDS levels s hold help t o ensure t hat reasonably clean and dry steam is delivered to the plant. The following Table provides some broad guidelines on the maximum permissible levels of boiler water TDS in certain types of boiler. Above these levels, problems may occur.

Water use without treatment. Improper Blow down. Improper chemical use. Improper combustion of fuel. Lack of Maintenance.

1. Boiler Fails to Meet System Load: (a)cause: the boiler thermostat is set incorrectly. Corrective action: is to check the thermostat setting. (b)cause: poor combustion. Corrective action: check flue, flame, and assess combustion quality. 2. Boiler and System Overheat: (a)cause: system controls are faulty. Corrective action: is to check voltage, temperature settings, and safety switches. (b) cause: The control thermostat failed and high-limit thermostat activated, or both controls may have failed. Action: to be taken is to check temperatures if they are higher than the high-limit set point, replace the high-limit thermostat.

(b) Cause: is inadequate airflow for combustion. Action: inspect the boiler, chimney, and boiler room fresh air intake for the source of the blockage. (c) Cause: test holes in the flue that are unsealed or flue leakage. Action: To correct, cover the holes and check for leakage. 4. Boiler Does Not Ignite (a) cause: Check for a boiler internal controls failure. Action: Investigate this possibility and reset or replace. (b) cause: The boiler may have previously overheated and the overheat cut-out has not reset. Action: Determine the cause of the overheat condition. Once it has been corrected, reset. (c) cause: The supply fuse may have blown or the supply isolated. Action: Establish the cause of the blown fuse and replace.

(d) cause: There may no pilot flame. Possibilities for this condition are: (1) a dirty or incorrectly installed pilot nozzle (2) insufficient gas supply to pilot (3) pilot flame ignites but becomes faulty (4) thermocouple voltage is too low 5. Boiler Fires Continuously (a) cause: is a thermostat fault. Action: Investigate and either repair or replace the thermostat. (b) cause: There could be a wiring fault. Action: Check the wiring and make the required repair. (c) cause: control valve that is faulty or sticking. Action: Replace the valve. 3. Fumes in Boiler Room (a) cause: incorrect combustion. Action: Perform a combustion analysis and correct.

6. Boiler Overheats and Is Noisy (a) cause: There could be poor circulation in the primary circuit. Action: Vent the system. (b) cause: low shunt-pump discharge pressure. Action: open a piping joint and check for foreign materials. There may be an air pocket in the line; purge the system. 7. Boiler Starts but Flame Goes Out Soon After (a) cause: is flue blockage. Action: : Check the flue for blockage. Check dilution fan operation. (b) cause: is primary low-pressure hot water (LPHW) circuit failure. Action: Check operation of the high-temperature cut-out. 8. Fault in Flue Gas System (a) cause: may be that the flue gas fan does not run during the start sequence. Action: Check the control circuit. (b) cause: fan has stopped during operation. Action: Check the fan, make any necessary fixes, and restart.

Boiler Hydraulic test: It is required once in a year to check the boiler stability by using 1.5 times pressure of Boiler design pressure. Boiler Over Heating: An overheating boiler may exhibit the following conditions: A discharging safety relief valve. Pressure and/or temperature readings above the maximum allowed for the boiler. Low or no water in boilers equipped with water-level gage glasses. Scorched or burning paint on the skin casing. Precaution: Do not try to relieve the pressure. Do not add cool water into the vessel. Do not try to cool the vessel with water. Let the vessel cool down naturally.

A boiler operator must have a certificate from Govt. for operating the boiler. All boiler must have to know how to operate the boiler within the permit limits. At the beginning of each shift, Operator make sure the equipment is operating properly Boiler operators should be familiar with the boiler s operating and maintenance manual Regular Activities should be performed on schedule and recorded Operating records and inspection records should be reviewed regularly by Engineer to ensure compliance.