Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Similar documents
Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation WARNING SXWS9561. Stainless Steel Panel Shower

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Installation Instructions

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LA90 DISCONTINUED IMPORTANT!

LA45 DISCONTINUED IMPORTANT!

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Terreon Lav Decks WARNING

LA60 DISCONTINUED IMPORTANT!

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Models: FM FM WARNING

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Installation IMPORTANT! Bradley Multi-Station Wall Sink

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

Installation Instructions OBSOLETE

Installation. S Series Navigator Thermostatic Mixing Valve

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

LVSD2 Verge Wash Basin LVS-Series

Installation Instructions

LVQD3 Verge with WashBar Technology LVQ-Series

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

Installation Instructions

Installation S

LVSD2 Verge Wash Basin LVS-Series

PAT BASIN MODEL 9121, 9131, & 9141

LVQD3 Verge with WashBar Technology LVQ-Series

Installation S

Installation S

Installation S

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

LVQD1 Verge with WashBar Technology LVQ-Series

Installation Instructions

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Installation S

Installation Instructions

Installation Instructions

Installation Instructions

MERIDIAN MODEL# 3793

Installation Instructions

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

Installation Instructions

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

Installation & Operation Manual

installation and operation manual for Hunter Ceiling Fans

Owner s Guide and Installation Manual

Package Content. Decor Star 1 2. PL-011-GS Rev. A

INSTALLATION INSTRUCTIONS

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

WELLWORTH /HIGHLINE WITH PEACEKEEPER VITREOUS CHINA TOILET

TSL-Aerofoil. wall mounted basin. installation + maintenance

GRANITE COMPOSITE SINK

ENGINEERED QUARTZ SINK Installation & Care Instructions

TIMES SQUARE TWO-HANDLE THERMOSTAT

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

INSTALLATION AND CARE GUIDE MARCO VANITY FRAME BASE & SINKTOP E E E E052463

INSTALLATION INSTRUCTIONS

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

Features Luxier SP26-GS

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

CAST IRON CLAWFOOT TUB

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

CARE & CLEANING GUIDE. Bathroom & Kitchen Products

Owner s Guide and Installation Manual

Installation & Operation Manual

STAINLESS STEEL OFFSET DOUBLE BOWL SINK

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

REVE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS 现代型分体座便器 CONTEMPORARY TWO-PIECE TOILET K-17178T-S/K-17178T-SP

INSTALLATION INSTRUCTIONS. Downtown Contempo Widespread Faucets Part # s: 8882-****, 8883-***

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Classic 6 & 18 Prep Procedure Tables Owner s Manual

Features Luxier SP21-SS

Owner s Guide and Installation Manual

Features Luxier SP21-SS

MEMOIRS VITREOUS CHINA TOILETS

Decor Star 1. Decor Star PL-037-SS

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

Assembly instructions. Alexandria Pedicare System ALEXANDRIA. Perfect design. Personal service.

Installation & Operation Manual

FL-1H, FL-1L Frequency Lavatory System FL-Series

Transcription:

LVD2 Verge Wash Basin LV-Series with Evero Natural Quartz Material Table of Contents Components...3 4 Supplies Required...5 Dimensions...5 6 Rough-Ins...7-8 Overflow Plug ssembly...9 Drain ssembly...9 Faucets and Optional Soap Valve...10 Bowl Mounting...10 Strainer and P-trap...11 djust Temperature...11 ccess Panel...12 Cleaning and Maintenance...13 215-1850 Rev. ; ECN 17-08-002 2017 Bradley Page 1 of 13 4/17/2017 P.O. Box 309 Menomonee Falls, WI 53052 US 800 BRDLEY (800 272 3539) +1 262 251 6000 bradleycorp.com

LVD2 WRNING Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Debris in supply lines can cause valves to malfunction. Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. Electrical power MUST remain off until installation is complete. Installer's hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out rating of 1,000 pounds. IMPORTNT Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installer. Product warranties may be found under Products on our Web site at www.bradleycorp.com. Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. For standard height mounting, do not exceed the recommended 33.5" distance from the fixture rim to the finished floor. 2 4/17/2017 Bradley 215-1850 Rev. ; ECN 17-08-002

LVD2 Components Drain dapter Prepack (S45-2480) O-Ring (125-111) Drain dapter LVD2BO Contact your Bradley Representative for color options Packing Washer #10-24 Screw Drain Cap (111-140) Drain Cap Spacer (269-2540) Trough Strainer (173-039) Trough Strainer Screw (160-353) ccess Panel Bracket (140-1172) #10 ccess Panel Thumb Screw (160-536) ccess Panel Security Screw Option (S45-2880) ccess Panel (186-1912) Wall Bracket (140-1128) Individual Rough-In Option Chrome P-trap (S29-094) Plastic P-trap (269-1697) TMV Supply Connections Plastic Hose TMV Valve (1/2" NPTM Outlet) (S45-2701) Tempered Supply Connections Supply Fittings (S45-2511) Plastic Hose Plastic Hose Supply Fittings (S45-2510) Stainless Steel Hose Hose Prepack (S45-2731) Hose Prepack (S45-2730) Bradley 215-1850 Rev. ; ECN 17-08-002 4/17/2017 3

LVD2 Components IR-DCD Faucet (S53-336) Plug-In Transformer Option (PT) for IR-DCD Faucet (S53-337) IR-DCG Faucet (S53-350) Plug-In Transformer Option (PT) for IR-DCG Faucet (153-486) *dapter included with faucet (TMV: S45-2872, TL: S45-2871) *dapter included with faucet (TMV: S45-2872, TL: S45-2871) CP-DC Faucet (S53-334) **dapter S45-2873 included with faucet Plug-in transformer option (PT) includes Transformer (S53-338), dapter (S53-339), and Grounding Kit (S53-349) for CP-DC Faucets Battery Box for CP-DC Faucets Optional Transformer 6315-KT0000 Soap Dispenser 6324-68 Soap Dispenser 6334 Soap Dispenser 4 4/17/2017 Bradley 215-1850 Rev. ; ECN 17-08-002

LVD2 Supplies Required (6) ³ ₈" fasteners and wall anchors for bowl and wall bracket (minimum pull-out rating of 1,000 lbs.) (4) ¼" fasteners and wall anchors for access panel brackets (minimum pull-out rating of 100 lbs.) ½" hot/cold or tempered stub-out 1½" NPT drain stub-out(s) OPTIONL: (2) 110 volt GFCI protected electrical outlets for 100 120 VC plug-in transformers only Screen filter(s) as needed, if not included with faucet(s) Drill Phillips screw driver Crescent wrench Flat head screw driver Tape Measure Level Dimensions Top View (shown with CP-DC faucet and 6315 soap) 15" (381mm) 5" (127mm) 6" (152mm) 6" (152mm) 15" (381mm) 2-1/2" (64mm) 21" (533mm) 14-3/8" (366mm) 56-7/8" (1444mm) 1-5/8" (40mm) Front View 3-3/4" (95mm) 59-3/4" (1518mm) 20" (509mm) 60" (1524mm) 50" (1270mm) Bradley 215-1850 Rev. ; ECN 17-08-002 4/17/2017 5

LVD2 Dimensions Side View 14" (357mm) 21" (534mm) 2" (50mm) 3-3/4" (95mm) 20 7-1/2" (191mm) 20" (508mm) B 7-1/2" (190mm) C D/TS Standard Height D/TS Juvenile Height (Children 6-12 years) CS Standard Height Dim 33-1/2" (851mm) 30-1/2" (775mm) 33-1/2" (851mm) Dim B 27" (686mm) 24" (610mm) 29-29/32" (760mm) Dim C 13-1/2" (343mm) 10-1/2" (267mm) 13-1/2" (536mm) 6 4/17/2017 Bradley 215-1850 Rev. ; ECN 17-08-002

LVD2 Structural Rough-Ins Mounting for Standard, D and TS height shown. Points, B and C require sufficient backing compliant with local building codes. WRNING Ensure bowl is completely seated in the wall bracket and securely fastened to the wall at point. Wall Bracket 36-1/2" (927) 25" (635) C L 25" (635) Secure bracket to wall using min. (2) 3/8" anchor bolts to the left of C/L and min. (2) 3/8" anchor bolts to the right of C/L. The (2) anchor bolts to the right of C/L must be min. 16" apart from the anchor bolts to the left of C/L. When mounting is complete, check to ensure the bracket is level. See Step 1: Bracket Mounting for more information. (mm) 33-1/2" (851) 31-1/2" (800) 25-1/4" (640) B C C B 3/4" (19) 13-1/8" (333) 28-1/8" (723) Bottom of Bracket 24-1/8" (612) 27-5/8" (701) 24-1/8" (612) 27-5/8" (701) CODE DESCRIPTION QTY. Install (1) 3/8" wall anchor with a minimum pull-out force of 1,000 lbs. per local codes at locations shown 2 B Provide structural backing compliant with local building codes. 2 C Install wall anchor with a minimum pull-out force of 100 lbs. per local codes at locations shown 4 RIM HEIGHT VERTICL HEIGHT DJUSTMENTS FIXTURE STYLE 33½" No djustment Standard Height, D, TS and CS 30½" Subtract 3" Juvenile, D and TS Bradley 215-1850 Rev. ; ECN 17-08-002 4/17/2017 7

LVD2 Plumbing and Electrical Rough-Ins Mounting for Standard, D and TS height shown. C L (mm) 4-1/2" (114) 25" (635) E E 33-1/2" (851) H C 24-1/8" (613) 17-1/2" (444) Min 1" (25) 2-1/4" (57) Finished Floor CODE DESCRIPTION QTY. 1½" NPT Drain, Stub-out 2" from wall 1 H,C ½" Nominal (⁵ ₈" O.D. Comp.) Hot/Cold supplies, Stub-out 2" from wall 1 E 110V GFI protected electrical outlet 2 8 4/17/2017 Bradley 215-1850 Rev. ; ECN 17-08-002

LVD2 1 Bracket Mounting Typical installation is shown. It may be necessary to repair the wall after mounting. The fixture may not cover all of the wall modifications. Mounting height per structural rough-in dimensions. 16" (406mm) min. Install wall bracket to wall per structural rough-in dimensions. Check to ensure the bracket is level. Example anchor locations shown. C L 2 Drain ssembly For ease of drain installation, lay the bowl on its back. O-Ring Drain dapter Packing Washer #10-24 Screw ssemble the remaining components as shown and thread the four screws through the drain adapter and into the basin inserts. Ensure the screws compress the drain adapter evenly onto the basin. Bradley 215-1850 Rev. ; ECN 17-08-002 4/17/2017 9

LVD2 3 Faucet For ease of drain installation, lay the bowl on its back. Other basin models may be shown for faucet mounting visual. Install the faucets and optional soap valves according to the manufacturer's instructions. 4 Bowl Mounting (to Bracket and Wall) WRNING Ensure bowl is completely seated in the wall bracket and securely fastened to the wall at point. CUTION Bracket is not intended to support the weight of bowl for an extended period of time. Be sure to secure the bowl to the wall using appropriate fasteners. CUTION Positioning bowl onto bracket may require two people. Position bowl above wall bracket. Press firmly on the back of the bowl to seat the bowl flange into the wall bracket lip. Ensure bowl is level. Secure the bowl to the wall anchors using fasteners per the structural B rough-in requirement (supplied by installer). 10 4/17/2017 Bradley 215-1850 Rev. ; ECN 17-08-002

H LVD2 5 Strainer and Drain Cap 1 station shown, 2 station similar. Faucet and soap removed for clarity. Note ngle of Drain Cap Drain cap is labeled front and back. Be sure front is facing the user. Top surface of drain cap should be sloped away from user. Front Position drain cap over trough strainer, aligning tabs into drain. Push drain cap down until drain cap is flush with basin. Grommets should hold drain cap securely against drain tough walls. To remove drain cap, carefully slip flat screwdriver into left or B right hand corner of drain cap and gently lift upwards. 6 djust Temperature with Water Running WRNING This valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in excess of 110 F (43 C) may cause scalding. Loosen Cap Screw about 1/4" (4-6 turns) and lift up cover (do not remove). B Using cover, turn cartridge gently until desired water temperature is reached. Do not turn past stops as this may damage unit. Push cover down and tighten screw. C Bradley 215-1850 Rev. ; ECN 17-08-002 4/17/2017 11

LVD2 7 ccess Panel Make all connections before installing access panel. Install access panel brackets to wall using #10 fasteners (supplied by installer) as shown in rough in drawing. Install top screw into slot. Do not install bottom screw until Step C is complete. Insert #10 thumbscrews into front bowl apron as shown. Thumbscrew in B vertical position is closed. Thumbscrew in horizontal position is open. #10 Thumb Screw #10 Top Screw CUTION For applications where children are present or for applications subject to vandalism, order security screw option S45-2880. Shown in closed position. Rotate 90 to Open Hang access panel onto mounting brackets attached to wall on the left and right sides. Rotate panel up and check fitup between thumbscrews and panel slots. C Rotate access panel down and make adjustment to brackets if necessary. Install bottom #10 fastener into brackets. ttach P-trap to drain adapter D and waste outlet. E F Rotate access panel up and secure by rotating thumbscrews to the closed position To open access panel, rotate thumb screw, slightly push panel up and swing access panel down. Do not remove thumbscrews. 12 4/17/2017 Bradley 215-1850 Rev. ; ECN 17-08-002

LVD2 Cleaning and Maintenance for Evero Material Description: Evero Natural Quartz Material is made of bio-based resin, natural quartz and other materials to resist chemicals, stains, burns and impact. Variations in the natural stone color, pattern, size, shape and shade are inherent. Due to these unique characteristics, please expect subtle shade variations when units are installed adjacent to each other. Routine Cleaning: For regular cleaning, use mild neutral base cleaners. Stubborn Stains: Remove tough stains, with non abrasive cleaners and pads such as a white Scotch Brite pad or Magic Eraser. Test on inconspicuous area prior to using the suggested products. Protecting the Surface: To optimize material performance in high use areas, it is recommended to apply DryTreat Stain-Proof Original or equivalent as needed. Repair Kits: Evero repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing. Repair kits are made to order and have a shelf life of 30 days. NOTICE! Do not use strong acid or alkaline chemicals and cleansers to clean Evero. If these chemicals come in contact with the surface, wipe them off immediately and rinse with soapy water. void contact with harsh chemicals such as paint remover, bleach, acetone, chloride based cleaners, floor cleaners, etc. void contact with hot pans and objects. Cleaning and maintenance instructions for stainless steel Material Description: Stainless steel is extremely durable, and maintenance is simple and inexpensive. Proper care, particularly under corrosive conditions, is essential. lways start with the simplest solution and work your way toward the more complicated. Routine cleaning: Daily or as often as needed use a solution of warm water and soap, detergent, or ammonia. pply the cleaning solution per the manufacturer s instructions and always use a soft cloth or sponge to avoid damaging the finish. Stubborn Stains: To remove stains from stainless steel use a stainless steel cleaner and polish such as Ball stainless steel cleaner or a soft abrasive. lways follow the manufacturer s instructions and apply in the same direction as the polish lines. NOTICE! Never use ordinary steel wool or steel brushes on stainless steel. lways use stainless steel wool or stainless steel brushes. Special Situations for Material Fingerprints and Smears: To remove fingerprints or smears use a high quality stainless steel cleaner and polish in accordance with the manufacturer s instructions. Many of these products leave a protective coating that helps prevent future smears and fingerprints. Grease and Oil : To remove grease and oil use a quality commercial detergent or caustic cleaner. pply in accordance to the manufacturer s instructions and in the direction of the polish lines. Precautions: void prolonged contact with chlorides (bleaches, salts), bromides (sanitizing agents), thiocyanates (pesticides, photography chemicals, and some foods), and iodides on stainless steel equipment, especially if acid conditions exist. NOTICE! Do not permit salty solutions to evaporate and dry on stainless steel. The appearance of rust streaks on stainless steel leads to the belief that the stainless steel is rusting. Look for the actual source of the rust in some iron or steel particles which may be touching, but not actually a part of the stainless steel structure. NOTICE! Strongly acidic or caustic cleaners may attack the steel, causing a reddish film to appear. The use of these cleaners should be avoided. Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named are regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that all products should be used in strict accordance with package instructions. Bradley 215-1850 Rev. ; ECN 17-08-002 4/17/2017 13