GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Similar documents
ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Cast Iron Boilers. G Series ( kW)

INSTALLATION AND MANINTENANCE INSTRUCTIONS

superrange Super Series 4, Super Plus High efficiency modular boilers kW Commercial & Industrial Boilers

pressurejetrange Buccaneer GTE, Falcon GTS, Harrier GTS, Viceroy GTS, Viscount GTS, Vanguard L Pressure jet boilers kW

Pressure Jet Boilers. Pressure Jet Range. Commercial Heating Solutions.

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Proline GAS HOB Model TCG40IX Instruction Book

Hamworthy. Melbury HE. High Efficiency Steel Shell Power Flame Boilers Gas, Oil, Biofuel or Dual Fuel Burners. Outputs 530kW to 10000kW

Mikrofill Ethos Condensing combination boiler

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550

2 Concord CX - Installation

kw Btu/h Metres Feet l/min. Gal/min C C

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

range W, Plus Condensing boilers kW Commercial & Industrial Boilers

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

IDEAL. Concord CXA INSTALLATION & SERVICING MANUAL. Installers guide to commercial central heating boilers

Osprey 2 CFL

pressurejetrange Buccaneer GTE, Falcon GTE, Harrier GTE, Viceroy GT, Viscount GTE, Vanguard L Pressure jet boilers kW

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

INSTALLATION AND SERVICING

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

Installation and Operating Manual for the EcoStar 500 Oil Condensing Floor Standing Range Output Range kw

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

GENERAL. Note. To obtain gas consumption in l/s, divide gross heat input in (kw) by a calorific value of 37.8 (MJ/m 3 ).

Concord Super Series 4

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

PEGASUS F2 N 2S. CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

MODEL BTI 65 G InsTALLATIOn AnD user InsTRucTIOn united kingdom / IRELAnD HOT WATER storage HEATER

remeha Gas 3c ECO Technical information Fully condensing atmospheric gas boiler kw

Technical information. Remeha P 500. Pressurized boiler. Heat output: kw

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

CAST IRON ATMOSPHERIC BOILERS

SIGMA. Wall Mounted Cast Iron, Gas Fired Boiler for Central Heating Fan Assisted, Room Sealed, Electronic Flame Ignition and Control

Osprey 2 CFL

LAE10 LFE10. Use. Series 02

GAS GRIDDLE INSTRUCTIONS MODEL: PGG6 MODEL: PGG7

Bosch Group. 24CDi OF WALL MOUNTED COMBINATION BOILER FOR CENTRAL HEATING AND MAINS FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS

BAXI BOSTON ALL MODELS FLOOR STANDING OPEN FLUE (OF) CENTRAL HEATING BOILERS INSTALLATION AND SERVICING INSTRUCTIONS. GAS TYPE G20 (Natural Gas)

SIGMA WALL MOUNTED CAST IRON, GAS FIRED BOILER FOR CENTRAL HEATING FAN ASSISTED, ROOM SEALED, ELECTRONIC FLAME IGNITION AND CONTROL

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Sirius FS. Working towards a cleaner future

Light oil - kerosene burner

Installation & Servicing Manual. for the Ultra range of wall mounted fan assisted balanced flue gas boilers

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

A Guide to Commercial Hot Water from Hamworthy. Introducing Hamworthy s Product Ranges for Hot Water Generation:

DOMINA 102 COPPER WALL-MOUNTED COMBINATION, GAS FIRED BOILER FOR CENTRAL HEATING

Boiler Product Range

UBGHFF60W 60cm Gas on Glass Gas Hob

Dovre 250 Cast Iron Gas Stove

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

EDENA CLASSIC E. Model : kw INTALLATION AND SERVICING INSTRUCTIONS. Gas Fired Floor Standing Boiler. Réf. : CH I EN 09/05

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Synergy Grill User & Engineer Installation & Conversion Guide

ENERGY TOP. Condensing boiler solutions

Alpha CD13R,18R and 24R

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

INSTALLATION GUIDE, OPERATION AND SERVICE MANUAL

Heating Equipment. gas boilers RX GB. installation and servicing instructions

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

DOMINA 102 DGT INSTALLATION, SERVICING AND USER INSTRUCTIONS G.C. NO: Appr. nr. B99.06 A - CE 0461 AU /1-07/2001

INSTALLATION AND OPERATION MANUAL

FALCON COPPER WALL-MOUNTED COMBINATION, GAS FIRED BOILER FOR CENTRAL HEATING

CONDENSING COMBINATION BOILER. Installation, Servicing and User Instructions

FERROLI F30 INSTALLATION, SERVICING AND USER INSTRUCTIONS G.C. NO: Appr. nr. B99.06 A - CE 0461 BM /0-07/2001


INSTALLATION INSTRUCTIONS WALL MOUNTED, FANNED, ROOM SEALED, COMBINATION BOILER

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Installation and Servicing Instructions. Alpha CD50S and 70S. Wall Mounted, Fan Assisted, Gas Fired, High Efficiency Condensing System Boilers

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

installation and servicing

Glow-worm 56/3e Back Boiler Unit

Assessment Schedule - TS.6

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Installation, operating and servicing instructions

TECHNICAL MANUAL MULTI-ELEC STANDARD BOILER 09/2011 CODE:

SPECIFICATIONS - NIKE

E1808, E1838, E1848 DEEP FAT FRYER INSTALLATION, SERVICING and USER INSTRUCTIONS

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

ES 140/H ES 160/H ES 180/H ES 200/H ES 220/H ES 260/H ES 300/H ES 340/H ES 380/H

Condensing Boilers. Floor Mounted - Evomod, Imax Xtra & Imax Plus III. Commercial Heating Solutions.

THESE INSTRUCTIONS TO BE LEFT WITH THE END USER

ES 140/H ES 160/H ES 180/H ES 200/H ES 220/H ES 260/H ES 300/H ES 340/H ES 380/H

This appliance must be installed and serviced by a competent person as stipulated by the Gas Safety (Installation & Use) Regulations.

Jetaire. Automatic & Manual (Propane) Heaters Operating and Maintenance Manual Models - LG 90M -150M/A - 280M/A - 350A

Transcription:

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION 51-102 kw

GENERAL DESCRIPTION 900 D a3 1000 762 672 E 222 The PEGASUS F2 range of atmospheric natural gas-fired boilers are constructed of cast iron finned sections joined by steel nipples and tie rods. Boilers are delivered to site fully assembled and incorporate an integral draught diverter giving all models a low profile silhouette. PEGASUS F2 boilers are designed for use with fully pumped indirect heating systems up to a maximum working pressure of 4 bar and flow temperature of 82 C. Standard controls and instruments include control thermostat, limit (manual reset) thermostat, lockout indicator lamp, ON/OFF switch, combined thermometer and altitude gauge. The PEGASUS F2 boiler is a fully automatic ignition version that provides flame rectification monitoring. All gas, flow and return connections are situated at the rear of the boiler. For ease of maintenance all cleaning of the flueways and burner servicing is carried out from the front of the boiler, which means that the side clearances are kept to a minimum making this boiler particularly suitable for modular installations. The system electrical and associated controls should be installed so that the boiler is never allowed to fire when there is no demand for heat. An LPG version is also available. For further details please contact Ferroli commercial boilers sales office. TECHNICAL DATA BOILER MODEL OUTPUT INPUT kw DIMENSIONS (mm) CONNECTIONS WEIGHT WATER kw BTU/h Nett Gross A B C D E F a1 a2 a3 kg Content lt PEGASUS F2 51 51 174,000 56.0 62.2 550 96.5 180 43 35 900 1 1/2 1 1/2 3/4 260 22 PEGASUS F2 68 68 232,000 74.8 83.0 640 96.5 180 46 38 900 1 1/2 1 1/2 3/4 305 26 PEGASUS F2 85 85 290,000 93.5 103.8 720 160.5 200 44 36 900 1 1/2 1 1/2 3/4 350 30 PEGASUS F2 102 102 348,000 112.0 124.3 800 106.5 200 42 34 900 1 1/2 1 1/2 3/4 395 34 MODULAR APPLICATIONS This boiler range, is particularly suited for modular applications since all servicing and flue cleaning is carried out from the front, so that side clearances are kept to a minimum. For further details please contact FERROLI commercial boiler sales office. INSTALLATION REQUIREMENTS The PEGASUS F2 boilers should be installed in accordance with the relevant requirements of the building Regulations, Health and Safety Executive Regulation PMS, IEE Regulations and the Byelaws of the Local Authority and the local water company. Only Corgi registered installers should fit the PEGASUS boilers. British Standard Codes of Practice CP341.300-307: Central heating by low pressure hot water. CP341.342: Part 2 Centralised hot water supply. CIBSE Guide: Reference sections B7, B11 & B13. IGE/UP/2: Gas Installation pipework, boosters and compressors on Industrial and Commercial premises. BS6644: Installation of gas fired hot water boilers rated inputs above 60 kw but not greater than 2 Mw. BS5410: Part 2 oil-fired installation of 44 kw and above. BS5440: Part 2 2001 up to 70 kw. WATER FLOW RATES The system design must ensure that adequate circulation takes place whist the boiler is firing or during a pump over-run period. MODEL F2 51 F2 68 F2 85 F2 102 Flow rate at t 11 C l/sec 1.1 1.47 1.83 2.2 Flow rate at t 20 C l/sec 0.61 0.81 1.01 1.21 The use of shunt pump is recommended where the minimum flow rate at t 20 C cannot be maintained together with the provision of a pump over-run device.

WATERSIDE PRESSURE DROPS Waterside pressure drops, to assist with selection of pumps the table indicates the hydraulic resistance (mbar) at t 11 C. MODEL F2 51 F2 68 F2 85 F2 102 mbar 95 110 105 110 GAS REQUIREMENTS BOILER MODEL MAIN BURNER INJECTOR PILOT INJECTOR GAS RATE INLET PRESSURE mbar BURNER PRESSURE mbar Nat Gas LPG Nat Gas LPG Nat Gas m 3 /h LPG kg/h Nat Gas LPG Nat Gas LPG Min Max PEGASUS F2 51 3.5 2.15 0.4 0.24 5.9 4.34 15 23 37 13.3 36 PEGASUS F2 68 3.5 2.15 0.4 0.24 7.9 5.79 15 23 37 13.3 36 PEGASUS F2 85 3.5 2.15 0.4 0.24 9.9 7.24 15 23 37 13.3 36 PEGASUS F2 102 3.5 2.15 0.4 0.24 11.8 8.68 15 23 37 13.3 36 VENTILATION Total gross input Position of Air vent areas Safe, efficient, and trouble-free operation of conventionally flued gas boilers is vitally dependent on the provision of adequate supply of fresh air to the room in which the appliance is installed. Ventilation by grilles communicating directly with the outside, air is required at both high and low levels. The minimum free areas of these grilles must be in accordance with the table shown. The use of an extractor fan in the same room as the boiler (or in an adjacent room in communication) can, in certain conditions, adversely effect the safe operation of the boiler. Where such a fan is already fitted, or if an extractor fan is likely to be installed at later date, then advice of the gas supplier should be obtained. Tests for spillage of products from the draught diverter when the extractor fan is running and all doors and windows are shut should be carried out after installation. If spillage is detected, the area of permanent ventilation must be increased. rating of boilers Air vents (Air direct from outside) 270 cm 2 plus 2.25 cm 2 Up to 2 MW High Level per kw in excess of 60 kw total rated input 540 cm 2 plus 4.5 cm 2 Up to 2 MW Low Level per kw in excess of 60 kw total rated input For further detailed recommendations consult BS5440 Part 2 2001 up to 70 kw and BS6644 for the 68 and above. WIRING AND CONNECTION DIAGRAMS - Electrical connections should be performed according to the diagrams shown here. - Connect the boiler to a single-phase, phase neutral, 230V-50Hz power supply through a standard terminal block or outlet with 2A max, fuses connected between the boiler and the power support. Remember that the boiler should always be provided with a good earthing. IMPORTANT - The manufacturer disclaims any liability for damage to property or persons caused by failure to earth the boiler correctly. General wiring diagram for mod. 51-68 Electrical connections diagram for mod. 51-68 24 Spark electrode 25 Pilot burner 32 Pump (not supplied) 49 Limit thermostat (manual reset) 63 Boiler control thermostat 82 Ionization probe 83 Ignition PCB 92 Flue gas thermostat 98 Boiler ON/OFF switch 114 Water flow pressure switch (not supplied) 116 Gas pressure switch 117 Main gas valve 118 Pilot light gas valve 129 Ignition lockout re-set botton 144 Timer 160 Auxiliary contact 169 Suppression filter 24 Spark electrode 25 Pilot burner 32 Pump (not supplied) 49 Limit thermostat (manual reset) 63 Boiler control thermostat 82 Ionization probe 83 Ignition PCB 92 Flue gas thermostat 98 Boiler ON/OFF switch 114 Water flow pressure switch (not supplied) 116 Gas pressure switch 117 Main gas valve 118 Pilot light gas valve 129 Ignition lockout re-set botton 144 Timer 160 Auxiliary contact

General wiring diagram for mod. 85-102 Electrical connections diagram for mod. 85-102 24 Spark electrode 25 Pilot burner 32 Pump (not supplied) 49 Limit thermostat (manual reset) 63 Boiler control thermostat 82 Ionization probe 83 Ignition PCB 92 Flue gas thermostat 98 Boiler ON/OFF switch 114 Water flow pressure switch (not supplied) 116 Gas pressure switch 117 Main gas valve 118 Pilot light gas valve 129 Ignition lockout re-set botton 144 Timer 160 Auxiliary contact 169 Suppression filter 24 Spark electrode 25 Pilot burner 32 Pump (not supplied) 49 Limit thermostat (manual reset) 63 Boiler control thermostat 82 Ionization probe 83 Ignition PCB 92 Flue gas thermostat 98 Boiler ON/OFF switch 114 Water flow pressure switch (not supplied) 116 Gas pressure switch 117 Main gas valve 118 Pilot light gas valve 129 Ignition lockout re-set botton 144 Timer 160 Auxiliary contact WATER TREATMENT Water contained in all heating and indirect hot water systems, particularly open vented systems, requires basic treatment. It is wrong to assume that because boilers are operating in conjunction with what is an apparently closed circuit, an open vented system will not under normal circumstances allow damage or loss of efficiency due to hardness salts and corrosion once the initial charge of water has been heated several times. One millimetre of lime reduces the heat conversion from flame via metal to water by 10%. In practice the accumulation of these salts is liable to cause noises from the boiler body or even premature boiler failure. Corrosion and the formation of black iron oxide sludge will ultimately result in premature radiator failure. Open vented systems are not completely sealed off from the atmosphere because it is necessary to provide a tank open to atmosphere if proper venting and expansion of system water is to be achieved. The same tank is used to fill the systems with water and it is through the cold feed pipe that system water expands into the tank when the boiler passes heat into the system. Conversely, when the system cools, water previously expanded is drawn back from the tank into the system together with a quantity of dissolved oxygen. Even if leakage from the heating and hot water system is eliminated there will be evaporation losses from the surface of the tank. Depending on ambient temperature these may be high enough to evaporate a large portion of the system water capacity over a full heating season. Corrosion will always occur within a heating/hot water system to a greater or lesser degree irrespective of water characteristics, unless the initial fill water from the mains is treated. Even the water in closed systems will promote corrosion unless treated.

PRODUCT RANGE BOILERS WALL-MOUNTED BOILERS With or without water production, these high performance, electronic and fully modulating systems are suitable for both hot water and heating applications. Models with outputs from 6 kw to 35 kw. CAST IRON BOILERS ATMOSPHERIC GAS FIRED High performance, with or without hot water production; models with outputs from 10 kw to 289 kw. CAST IRON BOILERS PRESSURE JET OIL AND GAS FIRED High performance, with or without hot water production, some models operate at low temperature. Models with outputs ranging from 17 kw to 650 kw. HOT WATER STORAGE CALORIFIERS From 100 to 500 litre capacity. WELDED STEEL BOILERS High performance models with outputs ranging between 87 kw and 10,465 kw for hot water, superheated hot water and steam up to 15 bar. SOLID FUEL BOILERS These units are ideal for burning wood chips and fluid fuels (2 fuels) with output ranging between 174 kw and 6,990 kw for production of hot water superheated hot water and steam up to 15 bar. AIR-CONDITIONING A complete range of products for air-conditioning ranging from mobile units, single and multisplit units, with chillers up to 143 kw. WHIRLPOOL BATH An exclusive range of whirlpool and showers complete with accessories are available in 4 colours. ALL FERROLI BOILERS ARE CE APPROVED AND CONFORM TO THE RELEVANT EUROPEAN STANDARDS.