KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Similar documents
DOCUMENTATION IPS640

Tebis application software

DOCUMENTATION IPS640

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

Connections, displays and operating elements C D E G H. Installing the control unit

Protecting you and your home

Movement controller comfort, Flush-mounted (Up) xx, xx

Installer Manual KNX Touchscreen Thermostat

Zone Terminal, 2-fold, FM MT/U , GH Q R0111

Operating instructions

Product and Applications Description

Info-Display xx

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

Technical Manual MDT Motion Detector

Version 1.03 January-2002 USER S MANUAL

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

Smoke Detector and Siren. Manual

Remote alarm unit Art. Nr.:

Synco living. Train the Trainer. Commissioning Safety & Security. Spring 2008 Page 1/21 Train the Trainer - Spring 2008

Use of the application program

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

Connections, displays and operating elements E F. 20s 3min

Sensors SR Programming manual

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

OPERATING INSTRUCTIONS

Tebis application software

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

Description of the application programme for KNX occupancy detectors version 3.1

0701 CO Light, HVAC, Monitoring, Brightness

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

PBI Manual. Paradox to KNX-BUS Interface

Application description

Integration Test Plan

Auro KNX Manual. Auro KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium. 1 / 23 v basalte

CBI-064. User Manual. Caddx to KNX-BUS Interface

2. Safety. 4. Function

KNX / EIB Product Documentation Page: 1 of 81

UP 258E11 OPTISENS OFFICE

KNX/EIB - Product database - Application description

Original operating instructions Safety switch with guard locking AC901S AC902S

Presence detector Komfort attachment Installation Instructions

Contents. Glossary

User manual. KNXpar. version

Product and Applications Description

Consultant Specification AGILE Wireless Fire Detection System

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Radio fire warning panel SRC 3000

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002

SCAN200E USER S MANUAL

Please use authentic SATA hard drive, USB device and battery.

Instruction manual. Remote control electric IR HEATER

Watchguard WGAP864 User Manual

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

AXI LED USER MANUAL (REV. 1.0)

ECO N DATE DESCRIPTION OF CHANGE CHG

GV2 Series Control Panels

Alarm System SECURE AS 302

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

10 Year Smoke Detector and Siren

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

FIB_FGBS-001 Universal Binary Sensor

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

POP_ Smoke Detector

Wireless Keypad GKP-S8M

PowerRouter application guideline

Parameterisable compact fault annunciator with permanent display

JA-63 Profi User manual

POP_ Smoke Detector

Sensors SR Programming manual

2G & 3G GSM Wireless Beam Alarm

Cold chain monitoring technologies. Facility monitoring

Devices for Special Applications

RESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize)

Controller - 4 x 1-10 V outputs - BUS/KNX

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

ADW 535 Line type heat detector

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

Test Unit GTL 100 for Fire Detectors

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Local Control Network - building controls in perfection

DALI SPECIFICATION GUIDE

ModBus DE-1 INSTALLATION AND USER MANUAL

The new detector from Rafiki

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

External Wireless Sounder

Panel Mounted Fault Annunciator Series

Simplex Panel Interface Guide

Tebis application software

Mounting instructions Genius Radio

Added password for IP setup page : Password must be in IP format!

Transcription:

Product definition KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no 2343 00) Art. no 2343 00 Page 1 of 22

Product definition Table of contents 1 Product definition... 3 1.1 Product catalogue... 3 1.2 Accessories... 3 1.3 Application... 3 2 Installation, electrical connection and operation... 4 2.1 Safety notes... 4 2.2 Device design... 5 2.3 Mounting and electrical connection... 6 2.4 Start-up... 7 3 Technical data... 8 4 Software description... 9 4.1 Software specification... 9 4.2 Software KNX module for smoke alarm device Dual/VdS... 10 4.2.1 Range of functions... 10 4.2.2 Information on the software... 11 4.2.3 Object table... 12 4.2.4 Functional description... 18 4.2.5 State of delivery... 19 4.2.6 Parameters... 20 Art. no 2343 00 Page 2 of 22

Product definition 1 Product definition 1.1 Product catalogue Product name: Gira KNX smoke alarm device module Application: KNX connection of smoke alarm device Dual/VdS Design: Installation Order No.: 2343 00 1.2 Accessories Smoke alarm device Dual/VdS Order No.: 2330 02 1.3 Application The Gira KNX smoke alarm device module connects a smoke alarm device Dual/VdS to Instabus KNX lines. It allows several smoke detectors Dual/VdS which are equipped with the Gira KNX smoke alarm device module to be networked. The module enables local alarms to be sent to the KNX bus and alarms to be received via the KNX bus. Alarms which the smoke alarm device receives via the 2-wire bus can be forwarded to the KNX bus via the module and received again and processed by alarm devices networked via KNX. Differentiating between local and remote alarms is possible but not necessarily required, a joint message is performed depending on the parameterisation. Configuring the alarm transmission interval is possible. The Gira KNX smoke alarm device module also enables monitoring the connected smoke alarm device. For this purpose, various pieces of state information from the smoke alarm device are made available via the KNX bus, for example the state of the battery. In addition, a general fault object is provided which can send to the KNX bus in configurable intervals and/or in case of a fault. The Gira KNX smoke alarm device module can also query the values recorded by the smoke alarm device as a temperature sensor and make them available on the KNX bus. For this, the ambient temperature is sent cyclically per day. Using the module, the connected smoke alarm device can be used as a signal transmitter. A signal tone can be triggered by a received KNX telegram. It can then be deactivated again after a defined period of time or by another KNX telegram. Art. no 2343 00 Page 3 of 22

Installation, electrical connection and operation 2 Installation, electrical connection and operation 2.1 Safety notes Electrical devices may only be installed and mounted by a qualified electrician. In doing so, the applicable accident prevention regulations must be observed. Failure to observe the installation instructions can result in damage to the device, fire or other dangers. The Gira smoke alarm device should only be planned, mounted and serviced by a "Certified expert for smoke alarm devices in accordance with DIN EN 14676". Smoke alarm devices which are planned, mounted or serviced improperly represent a risk because ideal smoke detection may not be able to be guaranteed. For this purpose, Gira offers the "Certified expert for smoke alarm devices in accordance with DIN 14676" online course, complete with certificate. It can be viewed online by clicking on the following link: http://akademie.gira.de Please see the operating instructions enclosed with the device for more information. Art. no 2343 00 Page 4 of 22

Installation, electrical connection and operation 2.2 Device design 1 KNX connection 2 Programming LED (red) 3 Programming button 4 Latch Art. no 2343 00 Page 5 of 22

2.3 Mounting and electrical connection Installation, electrical connection and operation Module 1. Connect the KNX bus to the KNX connection of the Gira KNX smoke alarm device module via the connection terminal (1). 2. Connect the 9 V monoblock battery to the battery connection and insert the battery into the battery compartment. The smoke alarm device cannot be latched into the mounting plate or 230 V base when no battery is inserted. 3. Insert the Gira KNX module into the module interface of the smake alarm device. The insert pins must lock. 4. Fasten the smoke alarm device to the mounting plate or the 230 V base for smoke alarm devices. 5. Perform a function test. Art. no 2343 00 Page 6 of 22

Installation, electrical connection and operation 2.4 Start-up The device can be started up after mounting the device and connecting the bus line. (The module can also be started up when not inserted). The following physical address is factory preset 15.15.255 This address has to be reprogrammed in order to be able to use the device. Programming the physical address of the module Programming is done in the programming environment of the ETS (3.0f, 4.0 or higher). An additional KNX data interface is required for programming. Make sure that the bus voltage is switched on. Press the programming button (3). Programming LED (2) lights up red Program the physical address using the ETS. Programming LED goes out after a successful programming process. Make note of the physical address on the device Programming the application programme and configuration data After programming the physical addresses, the application program must be imported to the device. Make sure that the bus voltage is switched on. Parameterise the device accordingly in the ETS Import the software to the device Start-up is complete Art. no 2343 00 Page 7 of 22

Technical data 3 Technical data KNX medium Start-up mode KNX connection Power consumption TP S mode (ETS) Bus connection terminal typ. 0.5 W Ambient temperature -10 C to +65 C Storage temperature -20 C to +65 C Installation width 38 mm Installation height 82 mm Installation depth 30 mm Protection type IP20 (compliant with EN60529) protection class III (compliant with IEC 61140) Test marks KNX, CE Art. no 2343 00 Page 8 of 22

Software specification 4 Software description 4.1 Software specification ETS search paths: Configuration: Security / smoke alarm devices S-mode standard Applications: No. Brief description Name Version 1 Gira KNX smoke alarm device KNX module for smoke alarm device Dual/VdS 1.0 Art. no 2343 00 Page 9 of 22

Range of functions 4.2 Software KNX module for smoke alarm device Dual/VdS 4.2.1 Range of functions Networking smoke alarm devices Monitoring the state of smoke alarm devices Art. no 2343 00 Page 2 of 22

Information on the software 4.2.2 Information on the software The Gira KNX smoke alarm device module can be parameterised for ETS 3.0f or higher. The Gira KNX smoke alarm device module is protected against importing an invalid application version. Art. no 2343 00 Page 3 of 22

Object table 4.2.3 Object table Number of communication objects: 19 Number of addresses (max): 36 Number of assignments (max): 36 Dynamic table management: no Maximum table length: 36 Alarm function Combine local and wired alarm = yes Send message cyclically Send alarm 0 Send Alarm 1-bit ETS4 1,002 C, R, T 1-bit object for signalling an alarm. Only visible when the "Combine local and wired alarm" parameter is set to "yes". This is triggered by a local heat alarm, a local smoke alarm and an alarm received via the networking terminal. A "1" is sent when the alarm has been triggered. Sent cyclically when "Alarm repetition" is activated. Alarm function Parameter: Combine local and wired alarm = no 0 Send Local alarm 1-bit ETS4 1,005 C, R, T 1-bit object for signalling a local alarm. Only visible when the "Combine local and wired alarm" parameter is set to "no". This is triggered by a local heat alarm, a local smoke alarm, and a local test alarm. A "1" is sent when the alarm has been triggered. Sent cyclically when "Alarm repetition" is activated. Art. no 2343 00 Page 4 of 22

Object table Alarm function Parameter: Send message cyclically Send alarm Combine local and wired alarm = no 1 Send Wired alarm 1-bit ETS4 1,005 C, R, T 1-bit object for signalling an alarm which was signalled via a 2-wire line. A "1" is sent when the alarm has been triggered. Sent cyclically when "Alarm repetition" is activated. Alarm function status output 2 Send Smoke alarm status 1-bit 1,002 C, R, T 1-bit object for signalling a local smoke alarm. A "true" is sent when the alarm has been triggered. Alarm function status output 3 Send Heat alarm status 1-bit 1,002 C, R, T 1-bit object for signalling a local heat alarm. A "1" is sent when the alarm has been triggered. Alarm function status output 4 Send Status alarm via wire 1-bit 1,002 C, R, W 1-bit object for signalling an alarm which was signalled via a 2-wire line. A "1" is sent when the alarm has been triggered. Alarm function input 5 Receive Auxiliary unit alarm 1-bit 1,003 C, R, W, A 1-bit object for activating an alarm. When a "1" is assigned to the object, the smoke detector emits an alarm. Simultaneously the state is transferred to the communication object 6 "Status alarm via KNX". This only works when the smoke detector is inserted. Smoke alarm devices are networked with one another via KNX using this communication object. Depending on the object value, the alarm is also activated via the 2-wire bus. Art. no 2343 00 Page 5 of 22

Object table Alarm function status output 6 Send Status of alarm via KNX 1-bit 1,002 C, R, T 1-bit object for signalling an alarm which was signalled via the auxiliary units communication object. A "1" is sent when the alarm has been triggered. Alarm function input 7 Receive Test alarm 1-bit 1,003 C, R, W, A 1-bit object for activating a test alarm. When a "1" is assigned to the object, the smoke detector emits a test alarm. Simultaneously the state is transferred to the communication object 7 "Status test alarm". This only works when the smoke detector is inserted. Alarm function status output 8 Send Status test alarm 1-bit 1,002 C, R, T 1-bit object for signalling a test alarm which was signalled via the test alarm communication object. A "1" is sent when the test alarm has been triggered. Signal transmitter function input / output Parameter: Switch-on duration signal tone 9 Receive Signal transmitters 1-bit 1,001 C, R, W, T 1-bit object to activate the signal transmitter. When a "1" is assigned to the object, the signal transmitter is activated. An assigned "0" deactivates the signal transmitter. It is automatically deactivated after the duration set in the "Switch-on duration signal tone" parameter and sends a "0" in this case. If the switch-on time is parameterised to "unlimited", the signal can only be deactivated by a telegram. The alarm signal (test alarm) of the smoke alarm device is used as the signalling tone. Art. no 2343 00 Page 6 of 22

Object table Temperature function Parameter: Send temperature cyclically 11 Send Temperature 2-byte 9,001 C, R, T 2-byte object which provides the temperature measured by the smoke alarm device. The "Send temperature cyclically" parameter can be used to define a transmission interval or transmission condition. If the condition "per day" is set, the temperature is send once a day. The function is deactivated when "Send temperature cyclically" is parameterised to "no". Error monitoring Parameter: Send message cyclically Send fault 12 Send Fault 1-bit 1,002 C, R, T 1-bit object for signalling a fault. If a "true" is sent, there is a fault on the smoke alarm device. This object is activated in case of the following faults: Defective smoke chamber Defective temperature sensor Weak battery 230 V error (if parameterised accordingly) Dirty smoke chamber Smoke chamber difference signal too low Smoke chamber electricity too high Smoke chamber has too many compensation pulses Smoke chamber loading time too high Temperature sensor 1 too warm Temperature sensor 1 too cold Temperature sensor 2 too warm Temperature sensor 2 too cold The value can be sent cyclically. The "Send message cyclically" and "Send fault" parameters are used to set this. Sending the message is deactivated when the fault is eliminated and "Fault acknowledgement" has been received. A "0" is sent in this case. Art. no 2343 00 Page 7 of 22

Object table Error monitoring 13 Receive Fault acknowledgement 1-bit ETS4 1,016 C, A 1-bit object for acknowledging a fault. Communication objects 11 and 14 to17 maintain their "1" value as long as the error is cleared and in addition this communication object is assigned a "1". Error monitoring 14 Send Battery fault 1-bit 1,002 C, R, T 1-bit object for signalling a battery fault. The message is triggered when the smoke alarm device signals "Weak battery". A "1" is sent if there is a fault. When the fault has been eliminated and a "1" is received on the " Fault acknowledgement" communication object, the object is set to "0". Error monitoring Parameter: Report 230 V fault = Yes 15 Send 230 V fault 1-bit 1,002 C, R, T 1-bit object for signalling a fault on the 230 V connection. The object is only visible when the "Report 230 V fault" parameter is parameterised to "yes". The message is triggered when the smoke alarm device signals a 230 V error (failure). A "1" is sent if there is a fault. When the fault has been eliminated and a "1" is received on the "Fault acknowledgement" communication object, the object is set to "0". Error monitoring 16 Send Smoke chamber fault 1-bit 1,002 C, R, T 1-bit object for signalling a smoke chamber fault. The message is triggered when the smoke alarm device signals a smoke chamber defect. A "1" is sent if there is a fault. When the fault has been eliminated and a "1" is received on the "Fault acknowledgement" communication object, the object is set to "0". Art. no 2343 00 Page 8 of 22

Object table Error monitoring 17 Send Temperature sensor fault 1-bit 1,002 C, R, T 1-bit object for signalling a fault of the temperature sensor. The message is triggered when the smoke alarm device signals a temperature sensor defect. A "1" is sent if there is a fault. When the fault has been eliminated and a "1" is received on the "Fault acknowledgement" communication object, the object is set to "0". Error monitoring 19 Send Alarm device fault 1-bit 1,002 C, R, T 1-bit object for signalling a communication fault between the KNX module and the smoke alarm device. A "1" is sent when there is a communication fault (even if the module is not inserted in a smoke alarm device). When the fault has been eliminated and a "1" is received on the "Fault acknowledgement" communication object, the object is set to "0". *The default values are specified. Art. no 2343 00 Page 9 of 22

Functional description 4.2.4 Functional description Alarms The module enables alarms to be sent and received using a KNX-TP connection. In this context, it is possible to differentiate between local and remote alarms or report them via a joint communication object. Settings are made using the "Merge local and wired alarm" parameter. Alarms can be sent in cyclical, configurable intervals. The corresponding settings can be made using the "Send report cyclically" and "Send alarm" parameters. State monitoring The state of the smoke alarm device can be monitored via the module. A general fault communication object is available for this purpose, as well as various communication objects for individual faults such as "Weak battery". The general "Fault" communication object for faults can be set to cyclical transmission. The "Send message cyclically" and "Send fault" parameters are used for this purpose. Temperature measurement The module can query the temperatures measured by the smoke alarm device and make them available on the KNX bus. Vie the "Send temperature cyclically" parameter the condition per day can be set (temperature is send once a day). The specific send time depends to the initialization of the KNX module. Signal tone The module enables a smoke alarm device to be used as a signal transmitter. A signal tone on the smoke alarm device can be activated and deactivated using a communication object. In addition, it is possible to have the signal tone deactivated automatically after the time period defined via the "Switch-on duration signal tone" parameter. Important: Due to the external triggering (e. g. test alarm) of the signal tone the battery lifetime of the smoke alarm device is drained faster. Art. no 2343 00 Page 10 of 22

State of delivery 4.2.5 State of delivery Physical address 15.15.255 Device name Gira KNX smoke alarm device Art. no 2343 00 Page 11 of 22

Parameters 4.2.6 Parameters Values: Comments: Gira KNX smoke alarm device Merge local and wired alarm Send message cyclically Yes No No Per minute Per hour Per day This parameter determines whether there is a joint communication object for the signalling of alarms triggered locally and via wire, or whether there are two individual objects. Local and wired alarms are combined via the "Alarm" communication object. The "Local alarm" and "Wired alarm" communication objects become invisible. The "Local alarm" and "Wired alarm" communication objects become visible. The "Alarm" communication object becomes invisible. This parameter defines the transmission cycle for faults and alarms. For both types of messages, a separate parameter can be used to set whether cyclical transmission or event-controlled transmission should be used. Messages are sent only in case of change. In this case, the "Send alarm" and "Sent fault" parameters cannot be changed. The messages are sent at a preset interval as long as the "cyclical" setting has been selected in the "Send alarm" or "Send fault" parameter. In addition, the messages are sent immediately in case of change. The messages are sent at a preset interval as long as the "cyclical" setting has been selected in the "Send alarm" or "Send fault" parameter. In addition, the messages are sent immediately in case of change. The messages are sent at a preset interval as long as the "cyclical" setting has been selected in the "Send alarm" or "Send fault" parameter. In addition, the messages are sent immediately in case of change. Art. no 2343 00 Page 12 of 22

Parameters Send alarm Send fault Report 230 V fault Only in case of change Cyclical Only in case of change Cyclical No Yes This parameter determines whether alarm messages should only be sent in case of change or cyclically. Alarm messages are sent only in case of change. Alarm messages are sent at the interval set with the "Send message cyclically" parameter and in case of change. Only available when the "Send message cyclically" parameter is not set to "no". This parameter determines whether fault messages should only be sent in case of change or cyclically. Fault messages are sent only in case of change. Fault messages are sent at the interval set with the "Send message cyclically" parameter and in case of change. Only available when the "Send message cyclically" parameter is not set to "no". The message of a 230 V fault can be activated or deactivated using this parameter. Activation is only advisable when a 230 V base is used. A 230 V fault is not sent and the 230 V fault is not evaluated by the "Fault" communication object. A 230 V fault is sent and evaluated by the "Fault" communication object. Art. no 2343 00 Page 13 of 22

Parameters Send temperature cyclically No Per day This parameter determines whether the temperature is sent to the KNX bus and when transmission should occur. The temperature is not sent to the KNX bus. The temperature is sent at the set interval. The specific send time depends to the initialization of the KNX module. Compare internal temperature sensors +0.0 C -10.0 C to +10 C (In steps of 0.5) If the temperature measured by the module consistently deviates from the actual value, it is possible to compensate this deviation using this parameter. The measured temperature is corrected by the configured value. Switch-on duration signal tone This parameter defines the maximum switch-on duration of the signal tone. Unlimited The signal tone can only be deactivated by a telegram. 1 s to 24 s The maximum switch-on duration of the signal tone corresponds to the configured value. Art. no 2343 00 Page 14 of 22