VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Similar documents
VIESMANN. Operating instructions VITODENS 100-W. for the system user

VIESMANN. Operating instructions VITODENS 111-W. for the system user

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN. Operating instructions DIGITAL TIME SWITCH. for the system user. Digital time switch for the Vitodens 100-W, type WB1B

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

VIESMANN. Installation instructions VITODENS 200-W. for contractors

VIESMANN. Installation instructions. Extension AM1. Safety instructions. for contractors. Part no

VIESMANN. Installation instructions VITOCROSSAL 200. for contractors. Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner

Baxi Maxflow Combi WM

Operating instructions Oil condensing boiler

GB24 & GB30. User Manual

Baxi Maxflow Combi FS

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

VIESMANN. Operating instructions VITOTRONIC 200. for the system user

Operating instructions

User's Instructions. Alpha CB50

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

Operating instructions

USERS GUIDE. LOGIC+ Combi 24, 30, 35

VIESMANN. Installation instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CM3 Gas condensing boiler with MatriX radiant burner

Operating instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

Logic+ Combi

Operating instructions

ir-range 8G /03.15 Changes reserved.

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

VIESMANN. Operating instructions VITODENS VITOLADENS VITOPEND. for the system user

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Operating instructions

The guarantee on this appliance is valid for 12 months from the first day of installation.

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

USERS GUIDE 24, 30. For installation guide see reverse of book

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

VIESMANN. Installation and service instructions VITODENS 111-W. for contractors

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

/2010 US/CA

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

VIESMANN. Installation and service instructions VITODENS 100. for heating engineers

VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

USER GUIDE VOGUE MAX SYSTEM

E-COMBI EVO E-SYSTEM EVO

USER GUIDE LOGIC HEAT H

VIESMANN. Installation and service instructions. EHE immersion heater. for contractors. EHE immersion heater

Open Vented Condensing Boilers

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

MURELLE EV HE 25/55-30/55

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

WHE 2.24 / WHE 2.24 FF

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

VIESMANN. Service instructions VITODENS 200-W. for contractors

VIESMANN. Service instructions. MatriX radiant burner. for contractors

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

Operating Instructions

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

24CDi, 28CDi & 35CDi II COMBI

DOMESTIC HOT WATER Follow operational sequence

2 Minimiser SE - User's

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

User manual. Logano GC 124 II. Gas boiler

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Operating Instructions VITOCROSSAL 300 WARNING WARNING IMPORTANT. Read and save these instructions for future reference. for use by heating contractor

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Operating instructions

Transcription:

Operating instructions for system users VIESMANN Heating system with control unit for constant temperature operation VITODENS 100 2/2005 Please keep safe

Safety instructions For your safety Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained! Danger This symbol warns against the risk of injury. Important information This symbol warns against the risk of material losses and environmental pollution. Note Details identified by the word "Note" contain additional information. Target group These operating instructions are designed for heating system users. Danger Incorrect work on the heating system can lead to life-threatening accidents. & & Electrical work carried out must be by a person qualified to work to Part P of the building regulations. & Work on gas appliances must only be carried out by a CORGI registered gas engineer. & If you notice the smell of gas contact your heating installer or TRANSCO immediately. Danger Escaping gas can cause explosionswhichmayleadtoserious injury. & Do not smoke. Prevent naked flames and sparks. Never operate light switches or those of electrical equipment. & Open windows and doors. & Shut off the gas supply at the meter control. & Remove all personnel from the danger zone. & Observe the safety regulations of your local gas supplier, found on the gas meter. If you smell flue gas inside the property Danger Flue gases may lead to lifethreatening poisoning. & Shut down the boiler. & Ventilate the boiler room. & Closealldoorsleadingtothe living space. 2

Safety instructions For your safety (cont.) If you notice fire from the appliance call the fire brigade. Do not attempt to extinguish the fire unless competent to do so. Danger Fire causes a risk of burns and explosion. & Shut down the boiler. & Close the fuel line shut-off valves. & Use a tested fire extinguisher, class ABC. Installation area conditions! Important information Incorrect ambient conditions canleadtodamagetothe heating system and put safe operation at risk. & Ensure ambient temperatures are higher than 0 ºC and lower than 35 ºC. & Prevent the air becoming contaminated by halogenated hydrocarbons (e.g. as contained in paints, solvents or cleaning fluids) and excessive dust (e.g. through grinding/polishing work). & Avoid continuously high humidity levels (e.g. through frequent drying of washing). & Never close existing ventilation apertures. Ancillary components, spare and wearing parts! Important information Components which are not tested with the heating system may damage the heating system, or affect its functions. Installation or replacement must only be carried out by qualified personnel. 3

Index Index Introduction Initial start-up... 5 Your heating system is pre-set at the factory... 5 General Description... 5 Where to find the controls Summary of controls and indicators... 6 & Opening the control unit... 6 & Control and display elements... 6 & Display indication... 7 Changing room temperature... 7 Start-up and shutdown Heating system start-up... 8 Settings Operating modes... 9 & Heating mode... 9 & DHW heating - combi... 9 Heating... 9 DHW (combi boiler only)... 10 DHW (system boiler only)... 10 Displays Heating water temperature and system pressure... 11 Switch OFF Switching OFF Vitodens with frost protection... 12 Heating system shutdown... 12 What to do System characteristics... 13 Fault messages in the display... 15 Repairs Cleaning... 16 Inspection and maintenance... 16 Energy saving tips... 17 Keyword index... 18 4

Introduction Initial start-up The initial start-up and matching of the control unit to local conditions and the structural characteristics of the building must be carried out by your heating contractor. Your heating system is pre-set at the factory Your combi boiler is ready to provide both central heating and hot water after installation. Your system boiler will provide both heating and hot water providing a cylinder is installed. Your heating system is ready for use. You may change the factory settings in accordance with personal requirements. Note All data is saved in case of power failure. The Vitodens 100 is certified to comply with the requirements of the relevant European Directives (90/396/ EEC, 73/23 EEC and 92/42/EEC) for use in Great Britain and Ireland with gas category I2H (G20 with a governed gas supply at 20 mbar (8 in.wg) inlet pressure). The appliance classification is either C13x or C33x depending upon whether a horizontal or vertical flue terminal is used. General Description The Vitodens 100 is a fully automatic, wall mounted, fan assisted balanced flue gas combination or system boiler for use with natural gas (G20) at 20 mbar (8 in.wg) supply on sealed systems only. The unit provides central heating at outputs between 8.0 kw to 24.0 kw/ 30.0 kw. If required, the central heating heat output can be range rated to suit the system requirements. Heat output is automatically controlledaccordingtodemand(inboth domestic hot water and central heating mode). Note that hot water is always given priority. 5

Wheretofindthecontrols Summary of controls and indicators Opening the control unit Controls and indicators are located behind the hinged front cover. Control and display elements The control unit is preset at the factory for standard operation. Your heating system is ready for use. A Time switch (accessory) B tw Rotary selector"dhw temperature" (Combi boiler only) C tr Rotary selector "heating water temperature" D Display, fault and reset button. E Display 6

Wheretofindthecontrols Summary of controls and indicators (cont.) Display indication A Display value or fault code B Heating mode C DHW heating D Burner in operation E Current burner output F Boiler primary water temperature in C (combined with display value) G Fault H System pressure (combined with display value) K Emissions test switch (only for qualified personnel) Changing room temperature In addition to the boiler control unit, a separate room temperature controller must be installed in one of the living rooms to comply with part L of the building regs if the heating system is to be regulated in accordance with the required room temperature. Make adjustments using the appropriate operating instructions. Please also note: It ist not recommended that thermostatic radiator valves are intalled in the same room as the controller. If thermostatic radiator valves are installed in the room where the controller ist fitted they mus be fully open. 7

Start-up and shutdown Heating system start-up The initial start-up and matching of the control unit to local conditions and structural characteristics of the building, must be carried out by your heating contractor. Before you switch ON a heating system which has been switched OFF for longer periods, it would be advisable to contact your local heating contractor. 1. Switch ON the mains power. Your heating system and, if installed, your room temperature controller Vitotrol 100 or similar programmable room thermostat are now ready to operate. 2. Control the pressure of the heating system by setting the rotary selectors to"tw "and"tr" to"9". The system pressure is displayed. Minimumsystempressure1.0 bar. Please contact your heating contractor if the system pressure is too low. Information regarding topping up the system can be found in the installation and service instructions. 8

Settings Operating modes Vitodens can be operated in the following modes: "heating" or "hot water". Heating mode If the room temperature controller Vitotrol 100, or similar programmable room thermostat, is connected, then the room temperature is controlled from there. Observe the separate operating instructions. Should the room temperature controller not produce sufficient heat (e.g. when it's very cold), the heating temperature can be changed at the rotary selector "tr". DHW heating - combi In the event of a demand for hot water, the appliance will detect water flow and initiate the ignition sequence. The fan (and pump) will start and the boiler will light. If the hot water demand is near to the maximum design flow rate the boiler will run continuously at full output until the tap is closed or the flow rate is reduced, the heat input will be reducedtomaintainasteadypreset temperature at the tap. Hot water is available almost instantaneously from the boiler, but the final outlet temperature and the delay in reaching full temperature will depend ontheflowrateandthedistancefrom the boiler to the tap. When the tap is closed, the boiler will return to heating mode if there is a demand for heating, otherwise the boiler will shut down until the next demand for heating or hot water. Heating Switching ON: Set rotary selector "tr" tothe desired heating temperature. The display "r" indicates when room temperature has been reached. Switching OFF: Turn heating rotary selector"r" to "r". 9

Settings DHW (combi boiler only) Operation with integral instantaneous water heater: Select the DHW temperature in accordance with your personal preferences (e. g. for showers). Switching ON: Set rotary selector "tw" tothe desired DHW temperature. The display "w" indicates when DHW temperature has been reached. Switching OFF: Turn DHW rotary selector"r" to "r". DHW (system boiler only) When in operation with separate a DHW cylinder, DHW temperature is regulated at the temperature control on the DHW cylinder. 10

Displays Heating water temperature and system pressure Checking the heating temperature During operation, heating water temperature is constantly displayed. Checking the system pressure 1. Turn both the rotary selectors"tr" and "tw" fully "9" anti-clockwise. The display now shows the actual system pressure, for instance 1.0 bar. 2. Return both rotary selectors to their original positions. Note The display will flash if the system pressure falls below 0.6 bar. In this instance, please notify your heating contractor. Information regarding topping up the system pressure can be foundintheinstallationandservice instructions. 11

Switch OFF Switching OFF Vitodens with frost protection Switch OFF the equipment if you don't want to use the boiler for a few days. Turn both rotary selectors to "9". Boiler frost protection is active. Heating system shutdown Shut down your heating system completely, if it will not be needed for longer periods of time (several months). Before you switch your heating system OFF for longer periods, it would be advisable to contact your local heating contractor. Your heating engineer will take any necessary measures, e.g. for frost protection of the system or to preserve the heating surfaces. 1. Close the main gas shut-off valve and safeguard against unauthorised reopening. 2. Switch OFF the mains power. Now the system is idle. Please note that the system is no longer frost protected. 12

What to do System characteristics What to do if... Cause Solution... the heating system doesn't come on Fuse has triggered (either at the fuse board or in the controls)... the boiler does not switch on (or switched on infrequently) System switch switched off System controls including room thermostats not calling for heatknob "tr" issetto"9" Knob "tr" issetto"9" Contact your heating engineer No gas Control fault Switch on System controls to create demand. 9 Set required heating water temperature (see page 9) Contact your gas utility supplier or heating engineer Read off the fault codes in the display. Contact your heating engineer and report fault codes. 13

What to do System characteristics (cont.) What to do if... Cause Solution... the burner doesn't ignite, the fault symbol "U" is displayed and "Reset" flashes red... the heating system doesn't come on... the burner doesn't ignite, display shows fault symbol "U" the burner switches off although the desired room temperature hasn't been reached 14 False start Low system water pressure System controls including room thermostats not calling for heat Control fault Fault in air supply or in the flue Heating water temperature or room temperature is set too low Press "Reset" button. If this attempt to start is also unsuccessful contact your heating engineer. The system pressure will flash in the display. Contact your heating engineer. It is possible to recharge system via the filling loop. Note: Care must be taken to ensure the fill valve is not left turned on. Viessmann Ltd will not be liable for incorrect use of the filling loop, if in doubt contact your heating engineer. Information re topping up can be found in the installation an service instructions. Switch on system controls to create demand. Read off the fault codes in the display. Contact the heating engineer and report fault codes. Contact your heating engineer. Increase heating water temperature by turning knob "tr" (seepage9) or increase desired room temperature (see Vitotrol 100 manual).

What to do System characteristics (cont.) What to do if... Cause Solution... the rooms are cold, even though the burner is working the temperature of the hot water is too low Hot water priority Fault on Vitotrol 100 or similar programmable room thermostat The hot water temperature is set too low or knob "tw" isseton"9" Stop using hot water Contact your heating engineer. Set desired hot water temperature Fault messages in the display Any faults in your heating system are indicated on the display by a flashing fault symbol "U". Read off the fault code in the display and report it to your heating engineer. 15

Repairs Cleaning The appliance casing can be cleaned usingadampclothandamilddetergent. Do not use abrasive cleaners. Inspection and maintenance To ensure continued efficient operation of the appliance, it is recommended that it is checked and serviced at regular intervals. The frequency of servicing will depend upon the particular installation conditions and usage but in general once a year should be adequate. It is the law that any service work must be carried out by a competent CORGI registered engineer. 16

Energy saving tips Energy saving tips Along with using a modern heating system, you can save additional energy by your own actions. For this, the following measures will help you: & Correct ventilation. If windows are left open A close thermostatic radiator valves B to prevent incorrect heat demand. & Do not overheat. Endeavour to reach a room temperature of 20 ºC; every degree of room temperature reduction saves up to 6 % of your heating bills. & Close roller shutters (where installed) at dusk. & Adjust thermostatic radiator valves B correctly. & Do not cover radiators C or thermostatic radiator valves B. & Utilise the setting options offered by control unit D. & Controlled DHW consumption: A shower generally uses less energy than a full bath. 17

Keyword index Keyword index C Cleaning... 16 Commissioning... 5 Controls... 6 D DHW temperature... 10 Display... 7 F Factory settings... 5 Faults... 13 Fire... 3 Frost protection... 12 G General Description... 5 H Heating and DHW... 5 Heating water temperature... 9 I Indicators... 6 M Maintenance... 16 O Opening the control unit... 6 P Pressure display... 11 R Room temperature... 7 S Safety information... 2 Smell of flue gas... 2 Standard room temperature (day temperature)... 5 Switching ON... 8 System pressure... 11 18

19

Printed on environmentally-friendly, chlorine-free bleached paper Your contact Contact your local heating contractor if you have any questions regarding the maintenance and repair of your heating system. You may, for example, find local heating contractors on the internet under www.viessmann.com. 20 Viessmann Limited Hortonwood 30, Telford, TF1 7YP, GB Subject to technical modifications