TECHNICAL INSTRUCTIONS

Similar documents
TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

VENTING APPLICATION GUIDE

TECHNICAL INSTRUCTIONS

PIPING APPLICATION GUIDE

Keysight 85025/85026 Detector Exchange Program - All Serial Numbers

AMP SUPERSEAL 1.5 SERIES Connectors

Inline Heater for Solvent or Gas. Installation and Operation Manual

SYSTEM CONTROL KIT Model: CK-41P

SmartPlate. Water Heaters. AERCO.com

Desiccant Tank Retrofit Kit for CD100/CS101 dehumidifying dryers

AM Rapid Recovery Water Heaters

User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

CO2 Sensor User and Installation Guide

COOPER POWER SERIES. S.T.A.R. TM Fiber optic cable installation instructions. Fault Indicators MN320004EN. Fiber optic fitting (To led display)

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

Induction Cooktop 30 inch & 36 inch

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Specification Status: Released

Quad Watch Winder

USER MANUAL (1 of 2)

Syclone Amalgam Separator Installation and operating guide

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

INSTALLATION TOOLS & ACCESSORIES

Specification Status: Released

COMBUSTION AIR SYSTEM

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

TrueClean ToteCleaner

NWA300 Field-Based Analog 4-20mA DC Current Meter User's Manual OM

Advanced Test Equipment Rentals ATEC (2832) Installation Note

Model R060 Installation - Operation Manual


ADMS. AERCO Digital Mixing Station. AERCO.com

User s Guide Home Automation Wall Socket for IWATCHALARM (Add-On) Model: SM-001SK

Hg5 Amalgam Separator Installation and Operations Manual

Heater Installation Kit

XT Series Thermostats

Technical Bulletin April Opticom Infrared System. Optical Preemption Detector Identification Guide

USER MANUAL (1 of 2)

FW-RA-LED Remote Multiplex Annunciator Panels

Specification Status: Released

MFC Series Boiler Vent and Combustion Air Guide

TrueClean ToteCleaner

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

WDB2 Series Bearing Temperature Sensor

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

BOILER APPLICATION GUIDE for:

Expanded Backup Control Installation & Operator s Instruction Manual

COOPER POWER SERIES. Types R, W, WV and RV reclosers, KA869R and KA835W series trip coils replacement instructions. Reclosers MN280020EN

Deluxe Discharge Alarm

Home Theater Interface Plate INSTALLATION INSTRUCTION

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

User s Manual and Operating Instructions

Washable HEPA Air Cleaner with PlasmaWave Technology

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

User s Manual For Model Aero-551 (Rev. Orig.)

120 VAC SYSTEM CONTROL KIT

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

INSTRUCTION MANUAL HS-229G

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

WIRING MODEL 20 Low Water Cut-Off and Pump Control MAXIMUM PRESSURE: 20 PSI INTERNAL WIRING BLUE WHITE UPPER PROBE (FEED OFF) FEED PROBE (FEED ON) ALL

Bridge to Splice Presser 710-BSP


Model PT-05 Model PT-06

Clean Steam Generators

USER MANUAL (1 of 2)

Raychem Link Boxes. Cable Services Limited. Powering the UK

DUST FREE CARBON Whole House Air Purifier

Z-PACK TinMan 85 ohm Connector Overview

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

COMBUSTION AIR SYSTEM Model: CAS-3

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

MaxLite LED Round Pendant Highbay Series

Viessmann B1HA Boiler Series

MaxLite LED MICRO-T PANEL

For information on any of these products, please contact your heating and air conditioning contractor or feel free to write or call us.

Service Parts, Kits and Accessories

Transcription:

TECHNICAL INSTRUCTIONS AERCO Serial Number & Code Plate Locations This document provides instructions for finding the serial numbers and code plates on AERCO products. Serial Number Sample Benchmark Code Plate Disclaimer The information contained in these instructions are subject to change without notice from AERCO International, Inc. AERCO makes no warranty of any kind with respect to this material, including, but not limited to, implied warranties of merchantability and fitness for a particular application. AERCO International is not liable for errors appearing in this manual. Nor for incidental or consequential damages occurring in connection with the furnishing, performance, or use of this material. 01/09/2014 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 1 of 5

Indirect Fired Heaters When facing the rear of the unit, the code plate is located near the top of the heat exchanger, within a cut-out portion of the insulation wrap. Modulex Family of Boilers The serial number and code plate information can be found on a sticker located at the top, right corner on the front panel of the unit. Remove the front panel to view the code plate. KC1000 Boilers & Water Heaters Remove the cap. When facing the rear of the unit, the code plate is located at the top of the insulation wrap. The label on the front includes the unit s serial number. 01/09/2014 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 2 of 5

Benchmark Family of Boilers On all Benchmark boilers and Innovation water heaters, the serial number is included on the code plate, and on a sticker label somewhere inside the enclosure (the same number is on both). The sticker and code plate locations are described below. It is generally easier to read the serial number off the sticker label. Find it on the code plate only if the sticker has become unreadable. Benchmark 1.5 Low NOx Boiler The serial number sticker is on the inside of the front door panel. The code plate is located on the rear of the heat exchanger, and is visible below the rear panel. Benchmark 2.0 Low NOx & Benchmark 2.0 Boiler inside of the front door, above the dimensional drawing. The code plate is located on the lower right side of the heat exchanger, near the rear of the unit. It is visible from the rear of the unit, but is easier to see if the right side panel is removed. 01/09/2014 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 3 of 5

Benchmark 3.0 Low NOx Boiler The serial number sticker is located on the inside of the front door panel. These units have two code plates, one on each heat exchanger: FRONT Heat Exchanger The code plate is at the front of the heat exchanger. BACK Heat Exchanger The code plate is at the rear of the heat exchanger. Note: Enclosure panels must be removed. Benchmark 750/1000 Boiler inside of the front-left vertical frame. exchanger, near the bottom. Remove the front panel to view the code plate. Benchmark 1500/2000 Boiler inside of the front-left vertical frame. exchanger, near the bottom. Remove the front panel, as shown on the left, to view the code plate. 01/09/2014 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 4 of 5

Benchmark 2500/3000 Boiler inside of the front-left vertical frame. exchanger nearer the bottom. Remove the front panel to view the code plate. Benchmark 6000 Boiler inside of the front-left vertical frame. exchanger, near the bottom. Remove the front panel to view the code plate. Note that, unlike the other Benchmark code plates, it is silver color, not red. Innovation Water Heaters control panel, visible once the front panel is removed. exchanger, below the gas train. 01/09/2014 AERCO International, Inc. 100 Oritani Dr. Blauvelt, New York 10913 Phone: 800-526-0288 Page 5 of 5