MINIMED 670G SYSTEM CHANGING THE QUICK-SET INFUSION SET QUICK REFERENCE GUIDE

Similar documents
MINIMED 670G SYSTEM CHANGING THE MINIMED MIO INFUSION SET QUICK REFERENCE GUIDE

MINIMED 670G SYSTEM CHANGING THE MINIMED SILHOUETTE INFUSION SET QUICK REFERENCE GUIDE

Administration of AMBISOME Using the GemStar Pump

BAXTER: FACTOR VII 600 IU (Plasma Derived)

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

Printer Startup and Demo Build The purpose of this section is to execute the following:

FACSCalibur Startup Procedures

Compact Refrigerator. User Manual Model 3590A

MODEL MC-UL592 MC-UL594 POWER SOURCE. 230V - 240V ~ 50 Hz MAX INPUT 1400 W 1500 W NOMINAL INPUT DIMENSIONS (W x L x H)

MC-CL481K MC-CL483K. Operating Instructions. Vacuum Cleaner. Model No.

HW-17 Record Cleaning Machine Setup and Instruction Manual

Table of Contents. What to Expect with. Mounting Options. Tools Needed

MODEL COMPRESSOR SERVICE KIT For use on Midmark Power Air Oil-less Compressor Models P21, P22 & P32

ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE

ALLERGEN MIXING ASSISTANT

Installation. Leveling

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

ULTRASONIC HUMIDIFIER WITH ANTIBACTERIAL TANK & BASE Instruction Manual and Warranty Information IM0012A READ AND SAVE THESE INSTRUCTIONS

Read the instructions and keep them safe. If you pass the iron on, pass on the instructions too. Remove all packaging, but keep it till you know the

MC-V Vacuum Cleaner. Specifications are subject to change without notice for further improvement.

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

Prizmatix UV Torch. User Manual

INSTALLATION GUIDE HIGH PRESSURE CLEANER (1800C) If there is any question during using, please feel free to contact us by

Installation Instructions

Upright Freezer 048-GM-48307

Installation Instructions

FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units

Operating Instructions ADA Glassware Washer

Security + Automation Made Easy QUICK START GUIDE

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

DISPLAY ALARM SYSTEMS

INSTALLATION. Glass Panel Doors (select models) CAUTION

Fillmore Small Pendant Assembly and Installation Instructions

Operating Instructions Undercounter Glassware Washer

Temperature/Humidity and Leak Detection Sensor Installation Manual for E-1W Sensors

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

PrimePour TM Operation Manual

CLEAN MIST ULTRASONIC HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0040A

ImPress IRONING STATION

Bravo II. High Performance Multi-Purpose Speaker

Your Pope Simple Set Automatic Tap Timer

Bathroom furniture installation instructions. Contents. Fitting of wall hung brackets 05. Getting started 02. Plumbing recommendations 05

HUMIDITY MANAGEMENT MODULE TYPE H122 Digital USER INSTRUCTIONS

THE MW-1 Cyclone RECORD CLEANING MACHINE

Portable Air-conditioner Use and Care Manual

START HERE. Set up. Your smart phone Receiver Sensor. Transmitter

Life Changing, Life Saving. The Vibby. User and Installation Guide

CEILING FAN OWNER S MANUAL

Mopit 4 Operator s / Service Manual

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

SRI 8610C GC for PCB in Transformer Oil Analysis November 2014

CEILING FAN OWNER'S MANUAL

Portable Air-conditioner

Home Medical Equipment Oxygen

Premium Micro Desoldering station

Speed switch moves up or down to adjust speed. Fast. Medium

TS40 Product Assembly & Service Information Manual

30-YEAR LIMITED WARRANTY

Smoke Sensor w/escape Light. Do not use this sensor in hazardous (classified) locations or life safety applications.

Apnoea Alarm. Information for parents and carers. MR 10 Respiration Monitor - Apnoea Alarm. Please read this leaflet carefully.

PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE.

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Table of Contents. Ceiling Bracket Installation

Multi-Mode Electrode pro

Owner s Guide and Installation Manual

original your automatic choice Socorex The Socorex original models Twin syringe = extended programme

CLEAN MIST SMART HUMIDIFIER TABLETOP & FLOOR STANDING WITH REMOTE CONTROL. Instruction Manual and Warranty Information

PERIOD ARTS FAN CO. Customer Service M-F 8am - 4pm (PST)

Margo Moo TM and Digger Dog TM Steam Inhaler Guidebook

DANGER Any appliance is electrically READ ALL INSTRUCTIONS BEFORE USING

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

ONTIME TIMER SPECIFICATION

EZ Bleed Solenoid Installation & Troubleshooting Guide

Glovebox Usage Manual v1.4. When you enter the lab walk straight to the log book. Enter all information including N2 and O2/H2O levels.

ULTRASONIC DIGITAL HUMIDIFIER Instruction Manual and Warranty Information IM0002A READ AND SAVE THESE INSTRUCTIONS

PORTABLE DOG BATH TOOL

Installation Instructions

INSTALLATION, OPERATION AND SERVICE MANUAL AERATION SYSTEMS FEATURING AIR COMPRESSOR AND AIR ELIMINATOR TANK

Table of Contents. 1 M /08/ Hunter Fan Company. What to Expect with. Preparation. Tools Needed.

User Manual. Compact Bagged Vacuum Cleaner. Dog & Cat W2000

Syringe Pump. User Manual

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

Replacing All Seals. This procedure explains how to replace all seals in the pump head assembly of the Alliance 2695 and 2795 Separations Modules.

FIREPLACE INSTALLATION

Hello. Classic. User s manual

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

Operator's Manual. LIGHTNING 2 Laser Detector

, '0''/).''$ /*'( 1'%* 00) ',))% *)) $ 3:36;$ !"## $%& '()*+,,,( '()*

Owner s Manual STAINLESS CONICAL CHIMNEY HOOD CONTENTS

DynamoPower. vax.com.au vax.co.nz DYNAMIC POWERFUL PERFORMANCE, FOR TOTAL HOME CLEANING LET S GET STARTED. TOTAL HOME VX54

Load Chicken: Refer: Africa Product, Oil Management

shine TM Manual User guide and installation instructions The global leader in door opening solutions

Installation Instructions

Installation Instructions

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

DESIGNED FOR HEAVY DUTY, OUTDOOR CLEANING

Electrician Installation Manual Majestic Madagascar Ceiling Fan

rlrm MOflel S DE-BY-SIDE REFRIGERATOR Always consult the Use & Care Guide for more operating information.

Transcription:

START HERE Wash your hands. Press. Select Options. Select Reservoir & Tubing. Select New Reservoir. Remove the infusion set you have been using by loosening the adhesive and pulling away from body. 6 Remove the used reservoir from the pump. Select Rewind. FILL RESERVOIR & CONNECT TO THE INFUSION SET TUBING Follow the next steps to fill reservoir with insulin and connect to the infusion set tubing. rod Reservoir Transfer guard Transfer guard Insulin vial Remove from package. Make sure insulin vial is at room temperature to reduce the risk of air bubbles. Pull plunger down to the amount that you plan to fill with insulin. Wipe vial with alcohol. Place vial on table. Firmly press the blue transfer guard onto vial. Push and hold plunger down.

WARNING If insulin or any liquid gets inside the tubing connector, it can temporarily block the vents that allow the pump to properly fill the infusion set. This may result in the delivery of too little or too much insulin, which could cause hyperglycemia or hypoglycemia. Insulin vial 6 7 8 With your thumb still on the plunger, flip over so vial is on top. thumb and pull plunger down to fill with insulin. Tap the reservoir to move air bubbles to top of reservoir. Push plunger up to move air into vial. If needed, pull plunger back down to amount of insulin needed for - days. To avoid getting insulin on the top of the reservoir, turn vial over so it is upright. Hold transfer guard and turn reservoir counterclockwise and remove from transfer guard. CONNECT RESERVOIR TO INFUSION SET You will place the tubing connector onto the end of the infusion set to the filled reservoir. Quick-serter Tubing connector Quick-set Connector Tubing slot Blue hub Hub handle Remove infusion set from package. Remove the paper that holds the tubing together. Gently push the tubing connector onto reservoir. Turn clockwise until locked. You will hear a click. If you see air bubbles, tap reservoir to move them to top. Push plunger just a bit to move them into tubing. Twist plunger counterclockwise to loosen and remove. THE BACKLIGHT MAY HAVE TURNED OFF Press any to turn the screen back on. Press to open the menu. If the pump is locked, you will need to unlock the pump after pressing. Select Load Reservoir from the menu. Select Next.

PLACE RESERVOIR INTO PUMP Now place the filled reservoir into the reservoir compartment of the pump. Place reservoir into pump. Turn clockwise until you feel reservoir lock into place. Select Next. LOAD RESERVOIR AND FILL TUBING Follow these steps to load the reservoir and fill the tubing. Select Load and keep holding. When you see this screen, select Next. INSERT INFUSION SET Next, follow the steps to insert the infusion set into your body. Blue hub Drops at end of tubing Select Fill and keep holding until you see drops at the end of tubing, then let go. After you see drops, press and select Next. Tubing slot Be careful not push or hold release Place blue hub into serter, placing the handle in the tubing slot. Holding the serter with one hand, gently press infusion set to secure. Be careful not to push all the way into serter. Do not hold or press on the blue.

Adhesive 6 Holding needle guard, pull off the paper that covers the adhesive. Pull green handle down until you hear it click. Choose an insertion site from the shaded areas shown here. Wipe with alcohol or other antiseptic. Turn to loosen needle guard and pull. 7 8 9 0 Hold serter against cleaned site. s Press the two green side s at the same time. Press down the release to unlock. Pull serter away from body. Press adhesive against skin. Hold infusion set. Pull blue handle straight out to remove needle. Fold blue handle until locked.

FILL CANNULA You will now fill the cannula, the little tube under your skin, with insulin. NOTE: Your pump will remember the Fill amount that you used last. Always verify that the Fill amount is correct. If it is correct, press to Fill Now and press. If it is incorrect, press. Change to correct amount and press. Select Fill Now. Select Fill. Select Fill Now. Select Fill amount and enter : 0.00 if using 6mm cannula 0.00 if using 9mm cannula Then press. The Home screen displays the insulin as it fills the cannula. NOTE: Select Stop Filling if you need to stop, for example, if you notice the Total amount is incorrect. This should rarely happen if you have verified the Fill amount on the previous screen. Your infusion set change is now complete! 90M60-0 0700 07 Medtronic MiniMed, Inc. All rights reserved.