NEO XL NEO XL NEO XL POWER SUPPLIES - MADE IN SWEDEN ENGLISH

Similar documents
Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

SITESTAR CABINET DESCRIPTION

Dale Power Solutions Ltd

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

5, SE GÅNGHESTER,

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation.

Installation, Operating and Maintenance Manual

Model 17A00 Expansion Enclosure

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Constant voltage 3-phase rectifier.

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

ANALOX 3000 Carbon Monoxide Monitor

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

Monitoring Devices 11/1

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Constant voltage charger. Type UP 610. »We store the world's energy« Network

EARTH FAULT METER MD-08

Intelligent Security & Fire Ltd

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Original instructions AR

AL800ULADA. NAC Power Extender. Installation Guide

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Commercial and Light Industrial Fire Alarm Control Panel

TECHNICAL DATA OBSOLETE

Conventional Fire Alarm System 2014 V1.2

WARNING FIRE DOOR CLOSING

Rack Mount Series Installation Guide

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Booster Power Supply Manual

Datasheet: K-22 LO Sensor

Model 4001 Series Single Channel Controller

Installation Guide for models:

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

MBZ300. Emergency power control unit. GB Installation instructions MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 MBZ300 PME PME. Reset.

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Multi-Gas-Controller MGC2

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Process Alarm Module RTA 421

AL600ULADA. NAC Power Extender. Installation Guide

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Series. Access Power Controllers. Installation Guide

Installation Guide for models:

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Installation guide for J4 Junction Box for R4 AIS Transponder System

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Operating Instructions. For. Alarm Control Module. Model SSR 500

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Power Supply Display Module PSDM. Installation and Operation Manual

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

Knürr RMS Compact II. Knürr RMS Compact II 2.81

System 57. An advanced World of intelligent gas detection system management

JDDT1 - Single Stage Digital Thermostat

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

LORAIN CIP 4890/48120 DC Power System

/9308 External Battery Chargers Installation Instructions

Excel-EN Conventional Fire Control Panel

4100U City and Relay Cards Installation Instructions

Fire Control Panel FS4000

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

FEC400 Series. Installation Manual

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Kædemotorer. Accessories

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Transcription:

NEO 27 50-XL NEO 27 100-XL POWER SUPPLIES - MADE IN SWEDEN ENGLISH

Milleteknik supplies reserve power which ensures operation. All our products are designed for optimum operational reliability and long service life, for electronics as well as batteries. SAFETY - READ THIS FIRST! Leave 100 mm of free space above and below the unit. The system is intended for use in controlled indoor environments. Only persons with authorization should install and maintain the system. It is the responsibility of the installer to ensure that the system is suitable for the intended use. Documentation that accompanies the system must be stored with the system or in the immediate vicinity. Ventilation must be not be covered. Mains voltage must be disconnected during installation. We reserve the right to make changes to any information whitout prior notice. 2

About the NEO XL series The NEO series is certified according to electrical safety approval EN 60950-1. The series offers high levels of operational reliability, efficiency and simplicity, in combination with most alarm functions as standard. DIN mounted power supply allows the power supply to be upgraded as systems expand. 19 angle brackets are supplied with all NEO Battery backups for mounting in 19 Racks or for wall mounting. The systems can also be expanded with battery box and battery shelves for longer reserve operation times. IP-Class 20. The NEO series is certified according to electrical safety approval: EN 60950-1. Areas of use Entry systems, burglar alarms, magnets, code locks, striker plates and smoke vents. About this document The applicable and most recently published edition of this document can be found at www.milleteknik.se or can be requested via e-mail, info@milleteknik.se (state unit name and serial number). This document's validity cannot be guaranteed because new editions are published without the previous message. Most recent english edition: Senaste svensk version finns här: Norsk versjon er tilgjengelig her: en swe nor Installation This instruction describes the installation and commissioning of the NEO-XL series. 3

Output voltage: 27.30 VDC 27.30 VDC Max. current: 5.0 A 10.0 A Battery capacity: 28 Ah / 45 Ah 28 Ah / 45 Ah Battery types: 2 x 12 V, 28 Ah / 2 x 12 V, 45 Ah Dimensions, (Height, width, depth): Technical data 2 x 12 V, 28 Ah / 2 x 12 V, 45 Ah 495 x 420 x 225 mm. 495 x 420 x 225 mm. Weight (including packaging, excluding batteries): 13 kg 13 kg Output voltage, ripple: Control accuracy: < 150 mvp-p < 100 mv Mains voltage, frequency 230-240 VAC, 47-63 Hz. Efficiency: 80-89 % Current limitation: Type 120 % of rated current. Constant voltage: I/U according to DIN 41773. Battery type/service life: VRLA batteries/rated service life at a temperature of 20 C. Deep discharge protection: Battery pole voltage: 21 V (24 V), 10,5 V (12 V). Alarm (relay switching): Power failure, low battery voltage (during battery operation), overvoltage, undervoltage, battery disconnected at start-up as well as defective power supply. Ambient temperature: 15-30 C Enclosure/Seal: IP 32 - for wall mounting. Testing: CE labelled. Certified according to: IEC 60950-1 (2nd edition) +A1:2009+A2:2013. Meets: EN 50081-1, EN 55011(B), EN 50082-2, EN 55022(B), EN 61000-3-2,-3, EN61000-4,-2,-3,-4,-5,-6,-11, Level 3. 4

420 mm 595 mm 495 mm 225 mm Note - the dimensions are not to scale 325 mm 5

Installation LEAVE 100 MM OF FREE SPACE ABOVE AND BELOW THE UNIT. Also leave 100 mm of free space behind the rack when mounting on the wall. The cabinet comes with: Documentation and any documentation for options. Battery fuses and terminals. Bracket and screws for mounting in 19 rack. Keys for lock. 420 mm etc. 19 rack 6 360 mm

Brief description P1 F6 D14 F4 F1 F2 F3 SW2 JU1 D1 Fan P2:1-2 P2:3-4 P2:5-6 P2:7-9 P2:10-12 J25 D3 D4 P1 Incoming power supply: JU1 Jumper for setting alarm level. Phase/Neutral/PE, earth. F6 Fuse Power supply (T2.5 A). D1 Indication LED. D14 The indication LED lights when J25 Connection to external fuse. F6 is intact and there is a power supply. F4 Battery fuse (T16 A). FAN Connect to fan. D3 Indication LED lights when fuse F1 and F2 are intact. F1 Output fuse Load 1 +. P2:1-2 Load output 1, + / - to load. F2 Output fuse Load 1 -. P2:3-4 Load output 2, + / - to load. F3 Output fuse Load 2 + / Unrated load 3 +. P2:5-6 Load output 3, + / - to unrated load, (max. 5 A). Over load output 2 + fuse. SW2 Pushbutton to start the system in battery mode, without routed mains supply. Only for function check. D4 P2:7-9 P2:10-12 Unrated load indication. The indication LED lights when F3 is intact and (sum) alarm is not triggered. Alarm terminal for mains power failure. Alarm terminal for: Charger fault/ battery fault/low battery voltage/ batteries disconnected at start-up. 7

Connection Power supply (wiring): Connect power supply wiring through the cable grommet on the underneath of the cabinet. P1: Power supply: Use the terminals supplied to install the power supply cables. F=Phase. N=Neutral. PE= Protective Earth. Connect terminal to P1 on the F P1 N PE circuit board. P2: 1-6 Load outputs: P2: 1-2 - Load: Load output 1, + / -, 2 pole, fused. P2: 3-4 - Load: Load output 2, + / -, 1 pole, fused. P2: 5-6 -Unrated load: Load output 3, + / -, (max 5 A). Common fuse with Load 2 +. P2: 7-12 Alarm: P2: 7-9 Power failure alarm. P2: 10-12 Alarm can be connected to alarm terminal that gives an alarm for: Function fault. Alarm in the event of low battery voltage during battery operation. Alarm in the event of battery fault at start-up. P2 P2:10-12 P2:7-9 P2:5-6 P2:3-4 P2:1-2 8

SAFETY Only persons with authorisation should install and maintain the system. Mains voltage should be disconnected when connecting batteries. Connecting Batteries Battery wiring is installed on circuit board at delivery. Note - the image only shows how wiring is to be connected. 1. Place the batteries in the cabinet with the battery poles outward, towards the cabinet door. 2. Connect the battery wiring from the circuit board as illustrated. 3. Turn on automatic fuse. When installing batteries in external shelf/box, see separate installation instructions. Connected in series: 24 V. 2 x 12 V, 28 Ah. 2 x 12 V, 45 Ah. + - + - If possible, cut mains voltage at battery replacement. 9

Commissioning/Testing The system is working normally when D1 lights green continually. D1 gives the same signals as the indication LED on the outside of the cabinet door. System test: 1. Turn on incoming mains voltage. 2. Indication LED, D1, lights green, normal operation. 3. Cut mains voltage to check that the unit works in battery mode and alarms. 4. Indication LED, D1, lights yellow for alarm type, see panel. 5. Turn on incoming mains voltage. Indication LED, D1, lights green, normal operation. SW2 : Only when power supply is not connected. Enables start-up in battery mode before power supply is connected to the system: Press SW2 to start the system. Resetting: Reset the system by disconnecting the battery cables and mains voltage and reconnecting after 5 seconds. Questions? +46 31-340 02 30 support@milleteknik.se Panel description and Alarm settings Panel. The system is working normally when the indication LED on the cabinet door lights green continually. The indication LED gives the same signals as D1. See panel on cabinet door for description of indication. 24 V (12 V) 27,3 V (13.65 V) 26,7 V (13,15 V) JU 1 = 24,5 V (12,25 V) Alarm levels in the event of dropping voltage: 24 V (12 V) Alarm. The system gives an alarm in the event of a function fault, power failure, low battery voltage, battery disconnected at start-up or defective power supply. Alarm levels. Jumper JU1 controls alarm level. If JU1 is not installed an alarm is given, when the voltage drops below 26.7 V, (13,15 V for 12 V), immediately during battery operation. If JU1 is installed, an alarm is given at 24.5 V, (12, 25 V for 12 V), alarm given when approx. 50% of the battery has discharged. 10

Alarm description Power failure alarm, P2:7-9. In the event of a power failure, the indication LED ( D1 ) on the board lights yellow and the panel also lights yellow continually, alarm is given on P2:7-9. Check that mains voltage is connected and that fuse F6 is intact. Overvoltage alarm, P2:10-12. In the event of an overvoltage alarm, the indication LED ( D1 ) on the board lights red and the panel also lights red continually, alarm is given on P2:10-12 and out on buzzer alarm. In the event of overvoltage, the system charge voltage exceeds 28.5 V. This can mean that the batteries or load are/is damaged. This may be due to incorrectly calibrated or defective power supply. Undervoltage alarm/low battery voltage, P2:10-12. In the event of an undervoltage alarm, the indication LED ( D1 ) on the board lights red and the panel also lights red continually, alarm is given on P2:10-12 and out on buzzer alarm. In the event of undervoltage alarm, the charge voltage falls below 26.7 V, (13,15 V for 12 V), if JU1 is installed an alarm is given at 24.5 V, (12, 25 V for 12 V). An undervoltage alarm indicates that the power supply cannot supply enough high voltage, may be incorrectly calibrated or defective. When installing new batteries, the system voltage may drop temporarily. The batteries then need charging. It can take up to 24 hours before the voltage increases to the correct level and the alarm stops. Disconnected batteries, P2:10-12. If the batteries are not correctly connected at start-up; the batteries are defective; if the fuses have tripped, the indication LED ( D1 ) and panel light red continually, alarm is given on the buzzer. NOTE! If the batteries are disconnected after start-up, no alarm is triggered (for disconnected batteries). 11

Maintenance 100% 80% 50% The system, with the exception of batteries, is maintenance free for installations in indoor environments. Batteries Batteries generate electricity via a chemical process and there is therefore a natural degradation of capacity. The main factor for battery service life is temperature. The greater the temperature, the shorter the service life. An ideal temperature is 20 C. 40 C 30 C 20 C 0% 1 år 2 år 3 år 4 år 5 år 6 år The illustration shows how the battery loses power, over time, when the temperature increases. Actual degradation varies. The date of manufacture that is stamped on the battery and the service life (stated by the battery manufacturer) applies to a completely unused battery. Thus, the actual service life varies. Batteries should be replaced after HALF the indicated service life for safe operation. Batteries purchased via Milleteknik have a service life of between 10-12 years, with a recommended replacement interval of 5-6 years. Battery replacement (For units with separate battery shelf or battery box; refer to the manual.) If possible, cut mains voltage at battery replacement. Battery replacement: 1. Remove the fuse from between the batteries. Turn off any automatic fuse. (Remove any battery fuse from the circuit board). 2. Note the position of the battery cables before removal. 3. Insert and secure the new batteries. 4. Connect the battery cables in the same way as before. 5. Reinstall the fuse on the circuit board, fuse(s) between the batteries and turn on any automatic fuse. 6. Turn on mains voltage. The indication LED may light red for a few hours until the batteries have charged. 7. Test the system by temporarily disconnecting the mains voltage, (= the load is powered by the batteries), and then turn the mains voltage back on. Battery recycling Recycle all batteries. Return old batteries to the manufacturer or take them to a recycling station. 12

This page is intentionally left blank. 13

This page is intentionally left blank. 14

This page is intentionally left blank. 15

Milleteknik's products supply reserve power which ensures operation for: Entry systems, (emergency exits), hold magnets, CCTV, smoke vents, spoken evacuation, external alarms, integrated security systems, burglary alarms *, fire alarms ** etc. Our product series meets the demands for small and large battery backup installations for all types of security systems. Find more information about us at www.milleteknik.se Circuit Kretskort board AC DC Transistor F N Extra EMC Filter PROTEC- SKYDD TION Övervakning Monitoring Load Last 1 Deep Djupurladdningsskydd discharge protection Load Last 2 etc. Transistor Load Last 3 Effektmotstånd Power resistor 350-007 User instructions in original. Milleteknik AB Ögärdesvägen 8 B SE-433 30 Partille SWEDEN POWER SUPPLIES - MADE IN SWEDEN +46 (0) 31-340 02 30 info@milleteknik.se www.milleteknik.se - 180123 Rev.1.2