MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

Similar documents
MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

Here we see the list of auto shutoff controls we will cover in the next few slides

TITLE 24 ICONOGRAPHY. Iconography System

Code Review TITLE PRESENTED BY POURIA NIKNAM

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL

MANDATORY MEASURES DAYLIGHTING. (Reference: Sub-Chapter 4, Section 130)

Hospitality Title Solutions

Education Title Solutions

Office Title Solutions

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

Healthcare Title Solutions

Are LED s ready for Prime Time?

WSA120: New Energy Codes and Lighting Controls

California Title Design Guide for Smart Lighting Control and Energy Solutions

ASHRAE October 18, 2013

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Code Compliance Commercial Application Guide

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

What s New in the 2013 Energy Code? Changes to mandatory Title 24 lighting requirements

Note: A summary of the applicable code sections is shown in the CEC _Table100A.

Demand Responsive Lighting Controls

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Codes and Controls Commercial Building Energy Code Requirements for Light Control. Michael Jouaneh, CEM, LEED AP September 20, 2012

Lighting Summary - Interior

Decoding 2016 Title 24, Part 6

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

visual environment technologies etcconnect.com

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Aesthetic, energyefficient. control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS

Wireless Lighting Control Made Easy

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

CA TITLE 24 QUICK SOLUTIONS GUIDE FOR

MANDATORY MEASURES. There are two major steps for exterior spaces to comply with Title 24:

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

WELCOME TITLE 24 REQUIREMENTS & THE MAXLITE PRODUCT LINE. 9/5/14 Webinar Presented by: Greg Murphy

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

Oregon Non-Residential Building Energy Code

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

PRESCRIPTIVE APPROACH

ANSI/ASHRAE/IES

Best practices in lighting design to comply with California s Title 24 energy code

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

August 15, 2013 Page 1 of 19

Lighting Application Guide for K-12 Classrooms

Best practices in lighting design to comply with California s Title 24 energy code

LPCMPIRM65 & LPCMPIRDSI65

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Exit Routes. Introduction/Overview. OSHA Regulations. Exit Route

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

2017 Lighting Incentive

Advances in Lighting Controls and the Impact of ASHRAE Requirements. Rich Rattray, LC OSRAM SYLVANIA

Daylighting Control Design and Application Guide

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

C A L I F O R N I A E N E R G Y C O M M I S S I O N

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

COMcheck Software Version Interior Lighting Compliance Certificate

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

ANSI/ASHRAE/IES

Agency for Health Care Administration

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

LIGHTING CONTROLS

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 26 ELECTRICAL

For additional information regarding R-3.1 residential care facilities please contact (951)

600 Watt Dimmer Install Guide

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) LTG-1-A

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Smart Energy Programmable Thermostat + Energy Monitor. EE542-1Z I User Manual

Analogue Dimming Microwave Presence/Absence Detector

Supporting the Requirements of EPAct 2005 Tax Deductions

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Application Guide to CA Title 24

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

A Guide for Applicants and Lighting Designers

Chapter 17, Initiating Devices

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel

2009 ELECTRICAL CODE REQUIREMENTS

Direct Dim Microwave Presence/Absence Detector

Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group. Technical Product Information

2016 Electrical Supplemental Plan Review List

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Agency for Health Care Administration

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

UC Irvine Environmental Health & Safety TITLE: FIRE WATCH AND OUT OF SERVICE NOTIFICATION

Installation, Start-Up, and Operating Instructions

ICC CODE CORNER 2015 International Fire Code

Advanced Lighting For Office

CHAPTER 7 ALTERATIONS LEVEL

LPC3BSP65 & LPC3BDP65

Transcription:

MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130)

MANDATORY LIGHTING CONTROLS 1. Area Controls: Manual controls that control lighting in each area separately 2. Multi-level Controls: Allow occupants to choose the appropriate light level for each area 3. Shut-off Controls: Automatically shuts off lighting or reduces light levels when illumination is not needed 4. Automatic Daylighting Controls: Adjust electric lighting in response to the presence of daylight 5. Demand responsive controls: Receive and automatically respond to demand response (DR) signals Section 130.1 (a) 10/7/2013 SLIDE 126 SECTION 6 MANDATORY MEASURES

MANUAL ON/OFF CONTROLS An area is a space enclosed by ceiling-height partitions. All lighting in each area must be controlled separately from luminaires in other areas by manual on/off lighting controls that are: 1. Readily accessible 2. Located in the same room or area as the lighting they control and with the lighting in view 3. Able to provide any required dimming or multi-level controls steps in addition to on/off Section 100.1 10/7/2013 SLIDE 127 SECTION 6 MANDATORY MEASURES

EGRESS LIGHTING Up to 0.2 watts per square foot of lighting may remain on during occupied hours only for emergency egress. This lighting must be designated for emergency egress on building plans. When controls are required to shut off all lighting in a building, this includes emergency egress lighting. Draft Measure Information Template Egress Lighting Controls, 2013 California Building Energy Efficiency Standards, California Utilities Statewide Codes & Standards Team, March 2011 Section 130.1 (a) 10/7/2013 SLIDE 128 SECTION 6 MANDATORY MEASURES

SEPARATELY CONTROLLED LIGHTING SYSTEMS General lighting must be controlled separately from all other lighting systems in an area. Display lighting must each be separately controlled on circuits of 20 amps or less. For example, window displays must be controlled separately from wall displays, which must also be controlled separately from case displays. When using track lighting: General, display, ornamental, and special effects lighting must be separately controlled. Section 130.1 (a) 10/7/2013 SLIDE 129 SECTION 6 MANDATORY MEASURES

PUBLIC RESTROOMS Any public restroom with two or more stalls may use a manual switch that is not accessible to unauthorized personnel. All other lighting controls are still required. Section 130.1 (a)2 10/7/2013 SLIDE 130 SECTION 6 MANDATORY MEASURES

MIXED-USE BUILDINGS For some mixed-use buildings, (e.g. high-rise residential, hotels, and motels) the common areas must comply with the Nonresidential Lighting Standards, while dwelling units must comply with the Residential Lighting Standards. Photo: UC Davis 10/7/2013 SLIDE 131 SECTION 6 MANDATORY MEASURES

MULTI-LEVEL LIGHTING CONTROLS Title 24 sets a minimum number of control steps and illuminance uniformity requirement for most major luminaire types in TABLE 130.1-A. These requirements are required in addition to any manual, daylight, shut-off or demand response controls. These criteria apply only to general lighting for enclosed areas that: Are at least 100 square feet in size Have a connected lighting load over 0.5 watts per square foot Has more than one luminaire or more than two lamps Section 130.1 (b) 10/7/2013 SLIDE 132 SECTION 6 MANDATORY MEASURES

MULTI-LEVEL LIGHTING CONTROLS Each luminaire must meet every step of the multi-level control requirement. Controlling alternating luminaires or rows of luminaires does not meet this requirement. 50% 100% Section 130.1 (b) 10/7/2013 SLIDE 133 SECTION 6 MANDATORY MEASURES

TABLE 130.1-A Section 130.1, page 138 10/7/2013 SLIDE 134 SECTION 6 MANDATORY MEASURES

AUTOMATIC SHUT-OFF CONTROLS Automatic shut-off controls turn off the lights when a space is unoccupied. All lighting must be controlled by one or more of the following: 1. Occupant sensing control 2. Automatic time-switch 3. Building Energy Management System 4. Other control capable of automatically shutting off all lights for vacant periods Photo: Lutron Section 130.1 (c) 10/7/2013 SLIDE 135 SECTION 6 INDOOR LIGHTING CONTROLS

AUTOMATIC SHUT-OFF CONTROLS Space parameters Each room needs to be separately controlled. A single control may not monitor more than 5,000 square feet of floor area (20,000 square feet in malls and single-tenant retail spaces). Applications The following types of lighting must be separately controlled: 1. General 2. Display 3. Ornamental 4. Display case Section 130.1 (c) 10/7/2013 SLIDE 136 SECTION 6 INDOOR LIGHTING CONTROLS

AUTOMATIC SHUT-OFF CONTROLS Countdown timer switches are usable only in: 1. Single-stall bathrooms smaller than 70 square feet 2. Closets smaller than 70 square feet 3. Lighting in sever rooms smaller than 500 square feet If time-based controls are used, occupants there after hours must be able to activate lighting as needed: Manual switch Temporary override Occupancy-based control Section 130.1 (c) 10/7/2013 SLIDE 137 SECTION 6 INDOOR LIGHTING CONTROLS

AUTOMATIC SHUT-OFF CONTROLS Adaptive controls in secondary spaces Controls for lighting in the following spaces must be capable of partially reducing lighting power during hours of operation in addition to providing full shut-off functionality when the building is vacant. Section 130.1 (c) 10/7/2013 SLIDE 138 SECTION 6 INDOOR LIGHTING CONTROLS

AUTOMATIC SHUT-OFF CONTROLS Warehouse aisles and open areas 1. Each aisle must be independently controlled 2. Minimum automatic 50% reduction in lighting power when vacant Section 130.1 (c) 10/7/2013 SLIDE 139 SECTION 6 INDOOR LIGHTING CONTROLS

AUTOMATIC SHUT-OFF CONTROLS Corridors and stairwells 1. Sensors/controls should be activated from all potential entrances 2. Minimum automatic 50% reduction in lighting power when vacant Section 130.1 (c) 10/7/2013 SLIDE 140 SECTION 6 INDOOR LIGHTING CONTROLS

AUTOMATIC SHUT-OFF CONTROLS Spaces that are exempt from automatic shut-off controls requirements: 1. Buildings with lighting in continuous use 24 hours per day, 365 days per year 2. Areas where partial on/off controls are required instead of shut-off controls (ex: stairwells and corridors) 3. Electrical equipment rooms 4. Emergency egress lighting Section 130.1 (c) 10/7/2013 SLIDE 141 SECTION 6 INDOOR LIGHTING CONTROLS

AUTOMATIC DAYLIGHTING CONTROLS Automatic daylight controls adjust electric lighting power when daylight is available. Automatic daylighting controls are required for luminaires that: 1. Provide general lighting 2. Are at least half in a skylit or sidelit area 3. Are in an area where the total installed general lighting power exceeds 120 watts Photo: Lutron 4. Are located in an area which has more than 24 square feet of glazing Photo: Lutron Section 130.1 (d) 10/7/2013 SLIDE 142 SECTION 6 INDOOR LIGHTING CONTROLS

AUTOMATIC DAYLIGHTING CONTROLS Automatic daylighting controls requirements: 1. If the controlled lighting has a lighting power density greater than 0.3 watts per square foot, controls must provide multi-level lighting in accordance with Table 130.1-A. 2. The combined illuminance from the controlled lighting and daylight must be at least as much as would be provided by the controlled lighting when no daylight is present. 3. When the light received from daylight is more than 150% of the design illuminance of the general lighting system at full power, the general lighting power in that space must be reduced by at least 65%. Section 130.1 (d) 10/7/2013 SLIDE 143 SECTION 6 INDOOR LIGHTING CONTROLS

DEMAND RESPONSE When the demand for electricity threatens to exceed supply, the power grid becomes less stable and the risk of outages increases. Demand response (DR) programs allow end users to temporarily reduce their electricity use in response to a notice or automated signal sent from a utility, independent system operator (ISOs) or other power provider. This flexibility in what time power is consumed helps reduce peak demand and maintain grid stability. Currently, participating customers also receive financial incentives. Section 130.1 (e) 10/7/2013 SLIDE 144 SECTION 6 INDOOR LIGHTING CONTROLS

DEMAND RESPONSE How DR Works In traditional, non-automated DR programs, a local service provider sends notification of a pending DR event to facility managers, via e-mail, phone call or text message, requesting a reduction in electricity consumption for a limited period of time. Automated demand response (ADR) programs make use of energy management technologies and controls to respond to DR events quickly. The provider issues an automated DR signal to energy management control systems enrolled in ADR programs. The systems then automatically respond by reducing electricity use according to pre-programmed load shed strategies. Section 130.1 (e) 10/7/2013 SLIDE 145 SECTION 6 INDOOR LIGHTING CONTROLS

DEMAND RESPONSE Lighting is extremely well-suited to DR 1. Peak demand periods typically coincide with daylight hours (noon to 5 p.m., particularly during summer months) 2. Research indicates illuminance levels can be reduced by as much as 20% without impacting end-user comfort. 3. Light levels can be immediately restored when DR events end Buildings larger than 10,000 square feet must be capable of responding to a DR signal by reducing building lighting power at least 15% while maintaining the uniformity requirements of Table 130.1-A. Spaces that use less than 0.5 watts per square foot and non-habitable spaces, such as storage closets, are exempt from demand response requirements and cannot be counted towards compliance. Section 130.1 (e) 10/7/2013 SLIDE 146 SECTION 6 INDOOR LIGHTING CONTROLS

SUMMARY OF MANDATORY LIGHTING CONTROLS DISCUSSION: What types of controls will retail spaces typically require? 1. Manual switches (what needs to be switched separately?) 2. Automatic shut-off controls (where are they required?) 3. Automatic daylighting controls (which lighting systems must comply?) 4. Demand responsive controls (how large does a building need to be?) 10/7/2013 SLIDE 147 SECTION 6 INDOOR LIGHTING CONTROLS

CHECK YOUR UNDERSTANDING: DEMAND RESPONSE An 18,000 square foot building is being constructed that will contain ten retail tenant spaces that are 1,000 square feet each. Do these tenant spaces need to comply with demand response signals? 10/7/2013 SLIDE 148 SECTION 6 INDOOR LIGHTING CONTROLS