EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

Similar documents
SPECIFICATIONS. Contents List

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Addendum for STI-6406 with Dual Access Control

Installation and ZONES: Operation Manual. Model: ON STI-34108

Illuminated Stopper Station Push Button

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Stopper II Heated Enclosure

Stopper II SERIES ADA. We protect the things that protect you

Product Catalog. For specs & details go to sti-usa.com 1

Product Catalog. For specs & details go to sti-usa.com 1

Go Smart. Go Wireless.

Enclosures, Covers & Cages. Vandalism & Theft. Buttons & Switches. Home & Work Series. Wireless Products. Fire Safety Products

MANUAL RESET ALARM RELEASE

COMPANY PROFILE PROTECTING THE THINGS THAT PROTECT YOU

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Over 25 years working around the clock, around the world

Owner s Guide and Installation Manual

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

180 Degree Ceiling Mounted Occupancy Sensors

DS160/161 Request To Exit PIR sensors Installation Instructions

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

MANUAL RESET ALARM RELEASE

DS160/DS161 Request To Exit PIR sensors Installation Instructions

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

Installation Instructions

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

TS93 EMF SERIES. INSPK NO Rev.03/10

Go Smart. Go Wireless.

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Operating Instructions. Temperature and Humidity EC Control. Model 35YV93

SP-1000X. Panic Device Power Controller Installation Guide. Rev

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

Installation Guide for models:

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

E-PLEX 5x70 Series Stand-Alone Access Controller. Installation Instructions

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

installation and operation manual for Hunter Ceiling Fans

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

MODEL /4" Conduit. (By others) Terminal Strips Companion unit (without electronics) not shown. Approximate Preload

AND ARCHITECT SPECIFICATIONS

ENERVEX RSV CHIMNEY FAN

CM800 Emergency Call System

INTRODUCTION / TABLE OF CONTENTS

ZC450-IB-09/13-01 US. Instruction Booklet. Zonecheck 450

Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

Owner s Guide and Installation Manual

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Installation Guide for models:

Figure 1. Figure 2. See notes 1 and 2 below.

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

FLT93 Installation, Operation and Troubleshooting Guide

Cat No. 099A. Digital Programmable Thermostat for Weekday/Weekend Setting. User Maunal

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

TotalPac 3 Firecyle III Deluge Remote controlled system

Power Supply Display Module PSDM. Installation and Operation Manual

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

DETCON MODEL AV2-C1D2C Hazardous Duty Class I. Div 2, Continuous Tone Alarm Station

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

Field Configurable Horns and Strobes

T874 Multistage Thermostat and Q674 Subbase

HORIZONTAL AGITATOR ASSEMBLY

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

ISIS SAFETY SYSTEM Installation guide

Motion Detector User Guide

Owner s Guide and Installation Manual

Conventional Releasing Control Panel

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

DH100ACDCI Ionization Air Duct Smoke Detector

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor

INSTALLATION INSTRUCTIONS

ELECTRO-FENCE TM. Fence Protection System. Installation Manual. EF_Install_V2

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

Drywall Screwdriver INSTRUCTION MANUAL

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Owner s Guide and Installation Manual

FMR Installation Instructions. Addressable Fire System Controller

Conventional Smoke Detectors KFAPO

21-light Remote Annunciator. Owner s Manual

Transcription:

EPO STATION EPO Station with push to activate, turn to reset button complete with a clear cover to help prevent accidental activation and a bold "EMERGENCY POWER OFF" label. Color: White Shell Phrase: EMERGENCY POWER OFF Button Activation: Push to Activate and Turn to Reset Stainless steel backplate. Integrated clear cover molded from thick, tough UV stabilized polycarbonate material. Station housing is molded of super tough UV stabilized polycarbonate. Button has two (2) Form "C" contacts rated 10 amp @125/250 VAC, 1/2 HP 30 VDC, 6A. Quality features include 1 ¼" contact depth which fits into a standard 1 ½" deep electrical single gang box. Patented design dramatically helps stop accidental activation. Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). Options: Horn. Emits a 65 or 85 db alert sound when the cover is lifted to gain access to the button. Includes lithium battery (estimated battery life is 5 years with normal use). 1.5 Depth white polycarbonate backbox for surface mount applications. Key to reset. (not a stock option) www.etechnologies.com 800 387 2537

Installation and Service Instructions STOPPER STATION SERIES 2000 PUSH BUTTON SAFETY NOTICE TO INSTALLERS AND USERS INSTALLATION NOTE: This push button has been tested according to UL2017. It is important to read, understand and follow all instructions provided with this product. Non-fire alarm initiating devices are listed in UL category UEHX. It is the installer s responsibility to comply with NFPA72 and 101, NEC, mounting specifications according to ADA and other applicable fire and electrical codes. To avoid electrical shock, DO NOT attempt to install this product when power is on. To avoid possible confusion with fire alarm initiating devices, do not mount a red stopper station near a manual fire alarm initiating device. ADA mounting compliance requires the operable part of the initiating device shall not be less than 1.1m (3 1/2 ft.) or greater than 1.37m (4 1/2 ft.) above finished floor service. After installation and testing are complete, provide a copy of this manual to all personnel responsible for testing and maintenance of this product. I. GENERAL Product Dimensions See page 7 Switch Rating SS-2XX5/LT MODELS, FORM C CONTACTS ON TIMER, 2 Form C contacts 125/250 VAC, 10 A, 1/2 HP 30 VDC, 6 A RATED 30 VDC 3A II. CONTENTS LIST QTY. DESCRIPTION 1 Button and Switch Assembly 1 201009 Reset Key 1 19001 Allen Head Screw #8-32 x 3/8 in. 1 19015 Allen Wrench 3/32 in. 4 19068 Screw 3.5mm x 13mm 2 19060 Screw #6-32 x 1 in. 1 19021 Ground Screw 4 19039 #6 x 1 1/4 in. SS SMS 4 19018 Plastic Screw Anchor 1 71100A Surface Backbox 1 Warranty Card III. INSTRUCTIONS Housing Removal... Page 2 Backbox Preparation... Page 3 Wire Connections... Page 4 Installation... Page 5 Key Reset Procedure... Page 6 Product Dimensions... Page 7-1 -

HOUSING REMOVAL BUTTON AND SWITCH ASSEMBLY 10271 SWITCH HOUSING AVAILABLE IN RED, GREEN, YELLOW, WHITE OR BLUE 19001 SCREW ALLEN HEAD #8-32 X 3/8 in. (1) PROVIDED 19015 WRENCH (1) PROVIDED REMOVE SCREW. PULL BOTTOM OF HOUSING OUT AND LIFT UP UNTIL TABS ARE RELEASED FROM SLOTS IN BUTTON AND SWITCH ASSEMBLY. - 2 -

BACKBOX PREPARATION (NOT INCLUDED WITH FLUSH MOUNT COVERS) DRILL POINT LOCATIONS PROVIDED TOP AND BOTTOM FOR 1/2 in. CONDUIT FITTINGS. DRILL AS NEEDED FIELD DRILLING FOR CONDUIT ENTRY IS REQUIRED. LOCATIONS SHOWN ALSO APPLY TO OPPOSITE, PARALLEL SIDE. J J H SWITCH BACKPLATE MOUNTING HOLES J BOX MUST BE INSTALLED WITH ARROWS POINTING UPWARD H THESE HOLES MUST BE J DRILLED OUT USING A 5/32 in. DRILL BIT - 3 -

WIRE CONNECTIONS COM NC NO CONTACT SET 1 THIS SIDE CONTACT SET 1 THIS SIDE CONTACT SET 2 COM NC NO CONTACT SET 2 COM NC NO STRIP 3/8 in. (9mm) CORRECT METHOD OF INSERTING MULTIPLE LEADS (1 WIRE EACH SIDE OF SCREW) INCORRECT METHOD OF INSERTING MULTIPLE LEADS (BOTH WIRES ON ONE SIDE OF SCREW) - 4 -

INSTALLATION 19018 ANCHOR (4) PROVIDED 71100A RED SURFACE BOX DRILL (4) 3/16 in. DIA HOLES 19039 SCREW #6 x 1-1/4 in. (4) PROVIDED 19060 SCREW #6-32 x 1 in. (2) PROVIDED 19021 GROUND SCREW BUTTON AND SWITCH ASSEMBLY 19021 GROUND SCREW TYPICAL FLUSH MOUNT SINGLE GANG OUTLET BOX BUTTON AND SWITCH ASSEMBLY 19060 #6-32 x 1 in. SCREW (2) PROVIDED - 5 -

KEY RESET PROCEDURE (#2 BUTTON) KEY-TO-RESET SLOT LOCATED UNDER BUTTON VIEW IN DIRECTION OF ARROW A PART #18061 ALIGN SLOT IN KEY (CONCAVE SIDE UP) WITH 2 SLOTS UNDER BUTTON PUSH IN UNTIL BUTTON POPS UP. SWITCH IS NOW RESET TURN-TO-RESET PROCEDURE (#9 BUTTON) TO RESET, TURN BUTTON IN DIRECTION OF ARROW UNTIL BUTTON POPS UP. - 6 -

INSTALLATION NOTE: ADA mounting compliance requires the operable part of the initiating device shall not be less than 1.1m (3 1/2 ft.) or greater than 1.37m (4 1/2 ft.) above finished floor service. 3.25 in. (82mm) 1.62 in. (41mm) 1.25 in. (32mm) PUSH 4.87 in. (124mm) NO COM NC PRODUCT DIMENSIONS ALL MODELS WITHOUT BACKBOX 3.25 in. (82mm) 1.62 in. (41mm) 4.87 in. (124mm) 1.56 in. (40mm) PRODUCT DIMENSIONS ALL MODELS WITH BACKBOX 3.18 in. (81mm) - 7 -

Safety Technology International, Inc. 2306 Airport Road Waterford, Michigan 48327-1209 Phone: 248-673-9898 Fax: 248-673-1246 Toll Free: 800-888-4784 E-mail: info@sti-usa.com Web: www.sti-usa.com Safety Technology International (Europe) Ltd. Unit 49G Pipers Road Park Farm Industrial Estate Redditch Worcestershire B98 0HU England Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 Freephone: 0800 085 1678 (UK only) E-mail: info@sti-europe.com Web: www.sti-europe.com ERMINALS S ONLY) A STOPPER STATION SHEILD SHIELD PIVOT VOLUME JUMPER BUTTON LEVER COVER MOUNTING SLOTS PCB GUIDE 123A LITHIUM BATTERY SOUNDER PCB HIGH LOW OFF VIEW A INSTALLATION INSTRUCTIONS 1. Rotate the button lever clockwise to the stop (as shown) so it is pointed toward the inside of the Stopper Station Shield. 2. With shield rotated to open position (approximately 90 to cover), insert shield pivots into slots on Stopper Station cover. 3. Place the volume jumper to desired sounder volume (see above). 4. Insert PCB fully into PCB guides. 5. Rotate cover to closed position. 6. Rotate cover to fully open position then back to closed position to ensure the Button Lever is pressed down onto the button. (If not, remove PCB and repeat steps 4 and 5.)) 7. Pull off the plastic battery tab with the battery remaining installed (sounder is now active). 8 Mount cover with shield onto contact assembly. 9. Install bottom screw to hold cover to contact assembly. STOPPER STATION COVER SCREW STOPPER STATION CONTACT ASSEMBLY INSTALLATION OF STI-6517S STI STOPPER STATION SHIELD AND SOUNDER All specifications and information shown were current as of publication and are subject to change without notice. 6517S JAN2011