PHOTOELECTRIC AMPLIFIER SERIES

Similar documents
SPACEMOTION SERIES SMM 01

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Retroreflective sensor with polarization filter

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

5.0. Photoelectric Sensors. Technical Reference. Introduction

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

General Specifications

Retroreflective sensor with polarization filter

2 General Application Photoelectric Sensors

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Automatic Self-Adjusting General Purpose Sensor

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

2 General Application Photoelectric Sensors

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Series PHOTOSWITCH Photoelectric Sensors. Standard and Timing. Description. Supplied Accessories

BOS 23K. Photoelectric Sensors BOS 23K

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Retro-reflective Sensing range: 0mm to 2000mm

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

English. Series. Installation and Use Manual

Compact Catalog Solar

O P Style Meter with Optical Sensor Switch

Wiring Transmitter and Detectors. mounting hole. A023a. mounting hole. A024a

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

1.7. Insulation fault evaluators EDS460/490 EDS461/491

UNIVERSAL COMPACT SENSORS

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

Ultrasonic Proximity Sensor

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Online data sheet WS/WE45-P260S01 W45 PRODUCT PORTFOLIO

General Specifications. Small size Fast 500µs response time Cable or quick-disconnect options 11 28V DC Operating Voltage Red output LED indicator

2 General Application Photoelectric Sensors

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Sensing light curtain as per DIN 18650/EN 16005

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

R Air flows from high pressure side to low pressure side. This principle can be applied to keep clean-air in the room or, alternatively, not to leak p

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Preventa safety modules

Sensing light curtain as per DIN 18650/EN 16005

FR Series Photoelectric Sensors

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Photoelectric sensors W27-3, Photoelectric proximity sensor, Background suppression

Reflective Optical Beam Smoke Detector User Guide

Laser Collimated Beam Sensor

GEZE AUTOMATIC DOOR SYSTEMS GEZE ACTIVATION DEVICES AND SENSOR SYSTEMS PERFECTLY CONTROLLED AUTOMATIC DOOR DRIVES BEWEGUNG MIT SYSTEM

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Ultrasonic Proximity Sensor

Photoelectric sensors W27-3, Photoelectric proximity sensor, Background suppression

Background suppression photo sensors

E3FA PHOTOELECTRIC SENSORS

Reliable Detection of Transparent Objects

1.7. Insulation fault evaluators EDS460/490 EDS461/491

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

2 General Application Photoelectric Sensors

InductIve SenSorS 2018

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

onlinecomponents.com

E3FA PHOTOELECTRIC SENSORS

SOCH AUTOMATION AND POWER SOLUTION

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

Wind Alarm Instrument


INFRARED MODULATED BARRIERS

OG-Cube Photoelectric Sensors Optical sensing technology

FIRERAY 5000 range USER GUIDE

Insulation fault evaluator EDS460-DG

Monitoring Devices 11/1

Ionisation single-tube smoke detector for duct mounting

A complete line of sensors. Helping make sense of the world around us

GENERAL APPLICATION SENSORS NEW! MINI-EYE. General Application Photoelectric Sensors. Small, Rugged and Powerful... yet Low in Price MINI-EYE 2-55

General Specifications

CAUTIONS ON INSTALLATION

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Wind Alarm Instrument x.x0x

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

E3FA PHOTOELECTRIC SENSORS

MINI-EYE MINI-EYE. 2 General Application Photoelectric Sensors. General Purpose Photoelectric Sensor

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

ST Wiring diagram. Product description. Standard temperature controller. Order number

2 General Application Photoelectric Sensors

S15 SERIES. Ceramics. Beverage & Bottling

Transcription:

PHOTOELECTRIC AMPLIFIER SERIES Telco s photoelectric amplifier series performs as good today as it did when it first appeared almost 25 years ago. But while the simple design of this iconic product has remained the same in all that time, the technology on the inside has been constantly refined so it continues to offer nothing less than the most reliable and powerful performance possible.

PHOTOELECTRIC AMPLIFIER SERIES PA 01 Description Operation mode and max sensing range: Thru-beam: 0-45 m Diffuse proximity: 0-3,5 m 230 V ac, 115 V ac or 24 V ac/dc supply voltage Automatic and/or manual sensitivity adjustment Sensor LED-drive Adjustable on/off time delay 1 relay or 1 transistor output STF Signal Tracking Feature Switch selectable light or dark function Switch selectable long or short range Power, output and signal status indicators Test input 11-pole DIN socket connection The PA 01 is a 1-channel photoelectric amplifier, which is to be used in conjunction with a set of remote transmitter and receiver from the series 101, 100, 110 or 120. This amplifier series offers a choice between automatic and/or manual sensitivity adjustment with or without a 0-10 sec on/off time delay via integral potentiometers located on the front panel of the amplifier. can be selected from either a relay or an NPN/PNP transistor output. Light or dark function and long or short range are switch selectable. In automatic mode, set up is required. This is achieved by pressing the teach-in button located on the front panel. This unique feature ensures that the transmitting power level is adjusted according to the application, thus achieving optimal hysteresis and excess gain. Once set up, the system will automatically compensate for moderate misalignment and contamination during operation. In manual mode, the teach-in button allows for an overall manual system test by temporarily disabling the transmitter. The sensor LED drive powers the optional monitor LEDs available on the remote sensors output () and power (). The feature STF allows up to 3 identical systems to operate within a close distance of each other without optical cross talk as each system automatically maintains different transmitter frequencies. Technical Data Supply voltage 115 V ac or 230 V ac 12-30 V ac / 12-36 V dc Voltage tolerance +/ 15 % Current consumption Max. 2,5 VA 1 open / 1 close, 230 V ac / 3 A, 120 V ac / 5 A 100 ma / 36 V dc Yellow LED sensor failure indicator sensor failure indicator Sensor monitor LED drive The green monitor LED on the receiver indicates Power ON The yellow monitor LED on the transmitter indicates PA 01 output activated Hysteresis Approx. 20 % Operation frequency 11 Hz 14 Hz Response time t / t 45 ms / 45 ms ON OFF 35 ms / 35 ms Delay t ON / t OFF PA 01 C 0 10 sec, adjustable Housing material Noryl Environmental Data Temperature, operation 10 to +55 ºC Temperature, storage 40 to +80 ºC Sealing class IP 40 Approvals a REMOTE PHOTOELECTRIC SYSTEMS I 23

PA 01 PHOTOELECTRIC AMPLIFIER SERIES Available Types Model Connection Supply Voltage 12 30 V ac 12 36 V dc 115 V ac 230 V ac Order Reference PA 01 A PA 01 A 519 PA 01 A 511 PA 01 A 510 Automatic NPN and PNP PA 01 A 619 PA 01 A 611 PA 01 A 610 PA 01 B PA 01 B 519 PA 01 B 511 PA 01 B 510 11-pole DIN socket Automatic/Manual NPN and PNP PA 01 B 619 PA 01 B 611 PA 01 B 610 PA 01 C Automatic/Manual on/off delay Note: Remote sensors and 11-pole DIN socket to be ordered separately. PA 01 C 519 PA 01 C 511 PA 01 C 510 NPN and PNP PA 01 C 619 PA 01 C 611 PA 01 C 610 Applicable Remote Sensors and Ranges Series Thru-beam Diffuse Proximity 101 8 m 0,6 m 100 10 m 0,7 m 110 23 m 1,6 m 120 45 m 3,5 m Wiring Diagrams Testinput Testinput Invert Invert C NO NC NPN/PNP 2 10 1 3 4 7 5 6 8 9 11 2 10 1 3 7 5 6 8 9 11 output output Dimensions and Descriptions Dip switch selection for: Light/dark mode Long/short range Dip switch selection for: Light/dark mode Long/short range Manual switch and sensitivity adjustment MAN AUTO Teach in RESET/TEST Teach in RESET/TEST 35 13 74 35 13 78 PA 01 A PA 01 B Dip switch selection for: On/off delay Long/short range Note: dark/light selection via 11 pole socket when pin 11 is shorted to 7 On/off delay adjustment Manual switch and sensitivity adjustment TIME MAN AUTO Teach in RESET/TEST 35 13 78 PA 01 C Telco reserves the right to change specifications without notice. 24 I REMOTE PHOTOELECTRIC SYSTEMS

PHOTOELECTRIC AMPLIFIER SERIES PA 09 Description Operation mode and max sensing range: Thru-beam: 5 m Diffuse proximity: 0,4 m 12 or 24 V dc supply voltage 1 relay output acc. to UNI 8612 Power and output indicators Screw terminals connection The PA 09 is a 1-channel photoelectric amplifier, which is to be used in conjunction with a set of remote transmitter and receiver from the series 101. This amplifier series is low cost, designed especially for the elevator and door industries, offering a relay output, designed according to the UNI 8612 standard whereby 2 relays are mounted in series. Technical Data Supply voltage 12 V dc or 24 V dc Voltage tolerance @ 12 V dc 10 / +20 % @ 24 V dc 15 / +20 % Current consumption Max. 2 VA relay 24 V dc / 2A Yellow LED sensor failure indicator sensor failure indicator Sensor monitor LED drive Hysteresis Approx. 30 % Operation frequency 10 Hz Response time t ON / t OFF 50 ms / 50 ms Delay t ON / t OFF Housing material Polystyrene Environmental Data Temperature, operation 10 to +50 ºC Temperature, storage 40 to +80 ºC Sealing class IP 40 Approvals a REMOTE PHOTOELECTRIC SYSTEMS I 25

PA 09 PHOTOELECTRIC AMPLIFIER SERIES Available Types Model Connection Supply Voltage 12 V dc 24 V dc Order Reference PA 09 B Screw terminals PA 09 B 504 PA 09 B 503 Note: Remote sensors to be ordered separately. Applicable Remote Sensors and Ranges Series Thru-beam Diffuse Proximity 101 5 m 0,4 m Wiring Diagrams Black Red Shield Yellow 1 relay C 2 relay NC 3 relay NO 4 power 5 power + 6 7 8 9 } } output Dimensions and Descriptions 5 5 22 73 Ø 3 52 C NC NO Power Power + Black Red Shield Yellow 1 2 3 4 5 6 7 8 9 10 Ø 3 45 52 PA 09 B Telco reserves the right to change specifications without notice. 26 I REMOTE PHOTOELECTRIC SYSTEMS

PHOTOELECTRIC AMPLIFIER SERIES PA 10 Description Operation mode and max sensing range: Thru-beam: 0-60 m Diffuse proximity: 0-4 m 230 V ac, 115 V ac, 24 V ac or 24 V dc supply voltage Manual sensitivity adjustment 1 relay or 1 transistor output Switch selectable light or dark function Switch selectable long or short range Power and output indicators 11-pole DIN socket connection The PA 10 is a 1-channel photoelectric amplifier. The PA 10 A is to be used in conjunction with a remote transmitter and receiver from series 101, whilst the PA 10 B is intended for use with series 100, 110, and 120. This amplifier series offers manual sensitivity adjustment via an integral potentiometer located on the front panel of the amplifier. can be selected from either a relay or an NPN/PNP transistor output. Light or dark function and long or short range are switch selectable. Technical Data Supply voltage 24 V dc, 24 V ac, 115 V ac or 230 V ac Voltage tolerance +/ 15 % Current consumption Max. 3,2 VA 1 open / 1 close, 250 V ac / 3 A, 120 V ac / 5 A 40 ma / 30 V dc Signal level indicator sensor failure indicator sensor failure indicator Sensor monitor LED drive Red LED Hysteresis Approx. 40 % Operation frequency Response time t / t 50 ms / 50 ms ON OFF 40 ms / 40 ms Delay t ON / t OFF Housing material 10 Hz 12 Hz Noryl Environmental Data Temperature, operation 10 to +50 ºC Temperature, storage 40 to +80 ºC Sealing class IP 40 Approvals abd REMOTE PHOTOELECTRIC SYSTEMS I 27

PA 10PHOTOELECTRIC AMPLIFIER SERIES Available Types Model Connection Supply Voltage 24 V dc 24 V ac 115 V ac 230 V ac Order Reference PA 10 A PA 10 A 513 PA 10 A 512 PA 10 A 511 PA 10 A 510 11-pole DIN socket NPN and PNP PA 10 A 613 PA 10 A 612 PA 10 A 611 PA 10 A 610 PA 10 B PA 10 B 513 PA 10 B 512 PA 10 B 511 PA 10 B 510 NPN and PNP PA 10 B 613 PA 10 B 612 PA 10 B 611 PA 10 B 610 Note: Remote sensors and 11-pole DIN socket to be ordered separately. Applicable Remote Sensors and Ranges Series Thru-beam Diffuse Proximity 101 (only PA 10 A) 11 m 0,9 m 100 (only PA 10 B) 15 m 1,1 m 110 (only PA 10 B) 35 m 2 m 120 (only PA 10 B) 60 m 4 m Wiring Diagrams C NO NC NPN/PNP 2 10 1 3 4 7 5 6 8 2 10 9 11 7 5 6 8 output output Dimensions and Descriptions Sensitivity adjustment Long/short range Light/dark switch 35 13 78 PA 10 A/B Telco reserves the right to change specifications without notice. 28 I REMOTE PHOTOELECTRIC SYSTEMS

PHOTOELECTRIC AMPLIFIER SERIES PA 11 Description Operation mode and max sensing range: Thru-beam: 0-70 m Diffuse proximity: 0-5 m 230 V ac, 115 V ac, 24 V ac or 24 V dc supply voltage Manual sensitivity adjustment Sensor LED-drive Automatic sensor test Adjustable on/off time delay 1 relay and 1 transistor output or 2 transistor outputs Switch selectable light or dark function Switch selectable long or short range Power, output and signal level indicators 11-pole DIN socket connection The PA 11 is a 1-channel photoelectric amplifier, which is to be used in conjunction with a set of remote transmitter and receiver from the series 100, 110 and 120. This amplifier series offers manual sensitivity adjustment via integral potentiometers located on the front panel of the amplifier. can be selected from either a relay and NPN or NPN and PNP transistor outputs with or without a 0-10 sec on/off time delay. Light or dark function and long or short range are switch selectable. The microprocessor controlled sensor test ensures that the system will automatically detect and indicate a faulty transmitter or receiver cable break or electrical failure during operation, through the relevant LED located on the front panel. The sensor LED drive powers the optional monitor LEDs available on the remote sensors output () and power (). Technical Data Supply voltage 24 V dc, 24 V ac, 115 V ac or 230 V ac Voltage tolerance +/ 15 % Current consumption Signal level indicator sensor failure indicator sensor failure indicator Sensor monitor LED drive Max. 3,5 VA 1 open / 1 close, 250 V ac / 3 A, 120 V ac / 5 A 60 ma / 30 V dc Yellow LED Red LED Red LED The green monitor LED on the receiver indicates Power ON The yellow monitor LED on the transmitter indicates PA 11 output activated Hysteresis Approx. 45 % Operation frequency 14 Hz 20 Hz Response time t / t 35 ms / 35 ms ON OFF 25 ms / 25 ms Delay t ON / t OFF PA 11 A 0 10 sec, adjustable Housing material Noryl Environmental Data Temperature, operation 10 to +50 ºC Temperature, storage 40 to +80 ºC Sealing class IP 40 Approvals a REMOTE PHOTOELECTRIC SYSTEMS I 29

PA 11 PHOTOELECTRIC AMPLIFIER SERIES Available Types Model Connection Supply Voltage 24 V dc 24 V ac 115 V ac 230 V ac Order Reference PA 11 A and NPN PA 11 A 303T PA 11 A 302T PA 11 A 301T PA 11 A 300T On/Off delay 11-pole DIN socket NPN and PNP PA 11 A 403T PA 11 A 402T PA 11 A 401T PA 11 A 400T PA 11 B and NPN PA 11 B 303T PA 11 B 302T PA 11 B 301T PA 11 B 300T NPN and PNP PA 11 B 403T PA 11 B 402T PA 11 B 401T PA 11 B 400T Note: Remote sensors and 11-pole DIN socket to be ordered separately. Applicable Remote Sensors and Ranges Series Thru-beam Diffuse Proximity 100 18 m 1,1 m 110 40 m 2 m 120 70 m 5 m Wiring Diagrams Supply Voltage C NO NC Load Supply NPN Supply Voltage NPN Load Supply PNP 2 10 1 3 4 9 7 5 6 8 2 10 9 1 3 7 5 6 8 output output Dimensions and Descriptions On delay adjustment Off delay adjustment Sensitivity adjustment Long/short switch Light/dark switch / sensor test indicator Sensitivity adjustment Long/short switch Light/dark switch / sensor test indicator 35 13 78 35 13 78 PA 11 A PA 11 B Telco reserves the right to change specifications without notice. 30 I REMOTE PHOTOELECTRIC SYSTEMS