Easy Series Control Panel ICP-EZM2

Similar documents
Easy Series ICP-EZM2. Quick Start Guide

Easy Series ICP-EZM2. System Reference Guide

Easy Series/RADION ICP-EZM2

ICP-EZM2. ICP-EZM2 Release Notes F01U Page Bosch Security Systems, Inc.

2000 Series. Program Entry Guide. Control Panels

Easy Series Intrusion Control Panel. Selection Guide

AMAX Intrusion Alarm Systems System overview

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

First Alert 1200C Installer Notes M. Leuck

Release Notes for Version 7.05 January 2007

Control/Communicator Installation Manual

Series. NX-4-EUR Control Panel. Installation manual

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

Security System. User Guide for the LED Command Center

Control/Communicator

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

RE6100 Series Helix Security and Automation Platform

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

GV2 Series Control Panels

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

AXI LED USER MANUAL (REV. 1.0)

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

D1265. User's Guide. Touchscreen Keypad

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Security System. User s Guide for the Text Command Center

Contents. Glossary

Installation Instructions

Destiny Destiny Owners Manual

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

Contact ID as of 2/2/2015

All tested. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

Property of Monitronics Inc

RUNNER 8/64. 8/64 Zones Control Panel. Program Summary Guide

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Fire Alarm Control Panels FPD-7024

Radionics D4112 Program Sheet

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Property of Monitronics Inc

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

User's Manual VISTA-40 N7003V1 6/97

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

Using Your. Security System With LED Keypad S5030, S5031, S5032

Wireless Keypads LKP(E)S8M Series

PROGRAMMING PROCEDURES (Table 3)

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

Control Panel. Solution 2000 / en Installation Guide

Contact ID as of 11/28/2018

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

DESTINY OWNER S MANUAL

CC408. Quick Reference Guide Solution 880

VISTA-50P VISTA-50PUL

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

LYNXR-2 Series Security System

Watchguard WGAP864 User Manual

Quick Programmer s Manual

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

EVO192 v3.0 Fire and Burglary What s New

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

Solution Ultima 862 Operators Manual ISSUE 1.10

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Solution Ultima Series Operators Manual ISSUE 1.00

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

LYNX Touch L5210 Series Security System

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

LYNX Touch Security System

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

/10 Rev A

P Zone Expandable Hybrid Security System

CC488. Quick Reference Guide Solution Ultima 880

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

Installation Manual Premier 412/816/832. Issue 10

Simon XTi Quick Operation Guide

Summary of Keypad Main User Commands

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

CONTACT ID REPORT CODES

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

VISTA-100 Commercial Fire & Burglary Partitioned System

GEM-P800 Programming Instructions

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

Digiplex LED Keypads User s Manual

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

ELECTRONICS LINE S TECHNICAL SUPPORT DEPARTMENT: (972)

Quick Reference Guide

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

ERS-3600B. PERS-3600B Personal Emergency Reporting System

1. Introduction. 2. Product overview

Transcription:

Easy Series Control Panel ICP-EZM2 en Quick Installation Guide

Easy Series Control Panel Table of contents en 3 Table of contents 1 Install the Enclosure 4 2 Wire the Control Panel 6 3 Configure the System 8 3.1 Configuring with the telephone 8 3.2 Configuring with RPS 8 4 Add/Change Users 10 4.1 Add users 10 4.2 Change users 10 5 System Test and Maintenance 11 6 Installer Telephone Menu 12 7 Appendix 13 7.1 Expert Programming 13 7.2 Country Codes 23 7.3 Default Passcodes 23 Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 02 F.01U.306.216

4 en Install the Enclosure Easy Series Control Panel 1 Install the Enclosure Refer to Figure 1.1 for the suggested placement of system components in the enclosure. Notice! Use proper anchor and screw sets when installing the enclosure on non-load-bearing surfaces, such as drywall. Follow anti-static procedures when handling the control panel board. Touch the earth ground terminal on the control panel board to discharge any static charge before working on the control panel board. If you install more than one control center, mount them at least 1.2 m apart. Do not install the RADION receiver within 15 cm (6 in) of the control centers metal enclosure. 5 6 7 1 3 2 4 12 VDC Figure 1.1: System component placement in enclosure Callout Description 1 Port for ICP-EZPK programming key and ICP-EZRU2-V3 Update Key 2 ICP-EZTS Cover and Wall Tamper Switch 2017.01 02 F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH

Easy Series Control Panel Install the Enclosure en 5 Callout Description 3 Ground connection Connect ground wire from enclosure to enclosure door. 4 Module mounting location 5 Module mounting location 6 Status LED ( ) System Test Button ( ) 7 Port for ICP-EZV2 Voice Module Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 02 F.01U.306.216

6 2 en Wire the Control Panel Easy Series Control Panel Wire the Control Panel Refer to Figure 2.1 for an overview of the system components and wiring. 1 IUI-EZ1 + R Y G B 2 RFRC-OPT 3 (+) R Y G B (-) DX2010 (+) (-) R Y G B (-) + (+) 11 9 4 B426 6 R Y G B (+) 10 7 (+) (-) 12 (+) (-) 8 5 B450 (+) (-) (+) (-) (+) (-) R Y G B Figure 2.1: Wiring diagram Callout Description 1 Control Center Mount within 3 m of control panel, Use CAT5 cable (twisted pair) for audio bus, Set data bus address (1-4), up to 4 controls max 2 RADION receiver 1 = Normal Operation 5 = Maintenance Mode 3 DX2010 Point Data bus Adr 102: Points 9-16 Expander Data bus Adr 103: Points 17-24 Data Bus Adr 104: Points 25-32 4 B426 Network Use address 6. Interface Module 2017.01 02 F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH

Easy Series Control Panel Wire the Control Panel en 7 Callout Description 5 B450 Conettix Plug-in Communicator Use address 6. 6 Supervised Points (single EOL) 7 Supervised Points (dual EOL) Normally open and normally closed options (2.2k Ω) Normally closed (2.2k Ω) 8 Keyswitch Options (single and dual EOL) ((2.2k Ω) 9 Prog Output (PO) 1 Options Switched 12v Switched Ground Dry Contact 10 Prog Outputs 2-4 NF A2P requires that sirens have a backup battery. When this siren requires a 14,1V to 14,4V supply, use the optional board EZPS-FRA or the auxiliary power supply IPP-PSU-2A5. Set the output as interior burglary alarm. 11 2-wire Smoke Detector Option 12 4-wire Smoke Detector Option EOL resistor (P/N: 25899) required. EOL resistor (P/N: 25899) and Bosch EOL relay module required Note: The system uses a 12 VDC battery, connected as shown. If using RADION devices: 1. Mount the bases for the wireless devices in the desired locations. Do not attach the wireless devices to the bases at this time. 2. Remove all power from the system. 3. Set the switch on the RADION receiver to normal operating mode = 1. 4. Reapply system power. Wait for the solid green circle to appear on the control center. 5. Enter the Installer Telephone Menu. Refer to Configuring with the telephone, page 8. Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 02 F.01U.306.216

8 en Configure the System Easy Series Control Panel 3 Configure the System Configure the system using one of the methods described in this section for your control panel type. 3.1 Configuring with the telephone Refer to Installer Telephone Menu, page 12 for the complete programming menu. Basic Programming: 1. Enter the Installer passcode (default: 4-digit 5432, 6-digit 543211). 2. Press [3] to enter the Basic Programming menu to make the following changes: Modify point types [1][2]. Record point descriptions [1][1]. Enter an account number [2][1]. 3. Press [#][#][#] to exit Basic Programming. 4. Press [1] to enter System Maintenance to configure wireless devices. 5. Select Wireless Configuration [6] from the System Maintenance menu. 6. After the system prompt, enter the point number (1 to 32) that you want to configure. The control panel announces the point number and the point type. If the point number is not currently assigned to a Wireless ID: To set Point Type, press [1]. To add a device, press [2]. Press [#] to exit. If the point number is currently assigned to a Wireless ID: To set Point Type press [1]. To replace a device, press [3] To delete this device, press [4]. Press [#] to exit. 1. Press [#][#] to exit to the main menu. 2. Press [2] to enter the User Menu to change the installer passcode. 3. Press [1] and change the Installer Passcode. 4. Press [#][#] to exit the User Menu. 3.2 Configuring with RPS In addition to the Installer Phone Menu, you may use RPS to configure an Easy Series control panel with RADION support. To configure RADION wireless points, specify the following information for each point: Device Type Point Type Wireless Point ID Wireless Alarm Inputs Since Wireless Alarm Inputs is only available in Expert Mode, you must use Expert Mode to properly configure the Easy Series control panel for RADION wireless devices. The following table shows the correlation between the current RPS Device Type values and the RADION Device Types. 1. Once the device type has been selected in RPS, enter the Wireless Point ID and Point Type via the wizard dialog. 2. Enter the RFID for the point as specified in the product packaging. 2017.01 02 F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH

Easy Series Control Panel Configure the System en 9 3. Select the desired Point Type from the drop-down menu. 4. Enter an appropriate value in the Wireless Alarm Inputs column. When setting up an Easy Series control panel to use RADION transmitters, only select from the RPS device types listed in the table below. RPS device type RADION transmitter Wireless alarm inputs PIR motion detector PIR detector (RFPR-12) PIR curtain detector (RFPR- C12) Motion Dual motion detector Motion detector (RFDL-11) Motion Wireless device type 3 Repeater (RFRP) None Smoke detector Smoke detector (RFSM) Smoke Door Window contact sensor Universal transmitter (RFUN) Wired or magnet Glass break sensor Glassbreak detector (RFGB) Glass break Wireless Recessed Point Recessed door/window contact (RFDW-RM) Magnet Wireless Bill Clip Bill trap (RFBT) Magnet Mini-Door-Window contact Door/window contact (RFDW- SM) Magnetic Notice! Do not use any other RPS device types when specifying RADION transmitter configurations. The columns labeled Wireless Sensor Sensitivity and External Power Input have no effect on the Radion Wireless Receiver/Transmitter configuration. These fields are not used by the Easy Panel Radion configuration. Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 02 F.01U.306.216

10 en Add/Change Users Easy Series Control Panel 4 Add/Change Users Enter the User Telephone Menu 1. Connect to the phone test posts or use the house phone. + 2. Hold down the test button for 10 seconds. 3. Enter the Master Passcode default 1234(55). 4.1 Add users Add Users 1. Enter the User Telephone menu. 2. Enter the Master User (User 1) passcode 3. Press [4] to enter the user menu. 4. Press [1] to add a new user 5. Repeat step 4 for additional users. Press [#] to return to the User Menu, or [#][#][#] to exit completely. 4.2 Change users Change Users 1. Enter the User Telephone Menu. 2. Enter the Master User (User 1) passcode. 3. Press [4] to enter the User Menu. 4. Press [2] to change a user. Press [2] repeatedly until the system speaks the desired user number. 5. Repeat Step 4 in Add Users. 6. Press [#] to return to the User Menu, or [#][#][#] to exit completely. 2017.01 02 F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH

Easy Series Control Panel System Test and Maintenance en 11 5 System Test and Maintenance Test the system for proper operation when installation and configuration are complete. 4 Press the System Test button on the control panel board for one sec. The system provides instructions throughout the test. Follow all instructions. 4 Contact the central monitoring station (CMS) to verify that all necessary test reports were received, including test reports from all installed input and output devices. Notice! After system installation and any control panel programming, perform a complete system test. A complete system test includes testing the control panel, all devices, and communication destinations for proper operation. Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 02 F.01U.306.216

12 en Installer Telephone Menu Easy Series Control Panel 6 Installer Telephone Menu 1. Connect to the phone test posts or use the house phone. + Installer Passcode 1 System Maintenance 2 User Menu 3 Basic Programming 1 2. Hold down the test button for 10 seconds. 3. Enter the Master Passcode default 1234(55). Set date and time 2 Full system test 3 System test menu 4 Event history 5 6 # Reset system Wireless configuration Exit 1 Change installer passcode 2 1 Most recent events 2 Events by date 3 Last alarm event 4 Last 10 events # Exit Change master user (User 1) passcode # Exit user menu 1 Points 2 Report configuration 3 Outputs 4 Country code 1 Record point description 2 # Exit Set point type 1 Select output function # Exit 1 Warning device test 2 Battery test 3 Communication test 4 5 6 Control center test Point test Operate Outputs # Exit 1 Set point type 2 Add a device 3 Replace a device 4 Delete a device 7 Expert diagnostic menu # Exit 1 Enter account number 2 Configure report destinations 3 Remote programming success # Exit 1 Signal level summary 2 Messages and packets received 3 Signal level in percentage 4 5 Filtered ambient signal level in percentage Realtime ambient signal level in percentage # Exit # Exit 4 Enter programming item, enter selection. Expert Programming 5 Two-Way Voice Session 6 Custom Messages 7 Programming Key # Exit 1 Talk to person at control center 2 # Exit Listen to person at control center 1 Record site description 2 Record Call for Service message # Exit 1 Send data from key to control panel 2 # Exit Send data from control panel to key 2017.01 02 F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH

Easy Series Control Panel Appendix en 13 7 Appendix 7.1 Expert Programming System Programming s Programming 102 Country Code 00 to 99(see Country Codes, page 23) 103 Enclosure Tamper Enabled 0 = Disabled 1 = Enabled 107 Fire Bell Cut-Off Time 0 to 90 min 108 Intrusion Bell Cut-Off Time 110 Intrusion Abort Window 111 Fire Alarm Cancel Window 112 Intrusion Cancel Window 0 to 90 min 15 to 45 sec 0 to disable, 1-10 min 5 to 10 min 114 Chime Tone Select 1, 2, or 3 115 Chime Mode Operation After System Off 116 Automatic Test Frequency Report 119 EN50131 Level 4 Access Code 0 = Off 1 = On 2 = Follows previous setting 0 = Off 1 = Daily 2 = Weekly 3 = Monthly 6-digit numerical passcode (0-9) 121 Daylight Saving Time 0 = Off 1 = North America (pre 2007) 2 = Europe & Asia 3 = Tasmania, Australia 4 = Rest of Australia 5 = New Zealand 6 = Cuba 7 = South America & Antarctica 8 = USA (post 2006) 122 Installer Passcode Override 0 = Disabled 1 = Enabled Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 02 F.01U.306.216

14 en Appendix Easy Series Control Panel System Programming s Programming 124 Point Alarm Verification 125 Faulted Points Allowed Threshold 0 = Off 1 = Cross Zone 2 = Intelligent Threat Assessment 3 = Confirmed Alarms 1 (initial entry door) 4 = Confirmed Alarms 1 (token, key fob, or keyswitch) 0 to 8 126 Exit Delay 0 to 255 sec 127 Entry Delay 0 to 255 sec 129 Recent Close Enabled 0 = Report not sent 1 = Report sent 131 Swinger Bypass Count 0 to disable, 1-15 133 System On Order Options 1 to 6 134 Cross Zone Timer 0 to 3600 sec 136 Clear Alarm Memory 0 = By any user 1 = By master user only 140 Demo Mode 0 = The system only speaks all telephone messages over the phone. 1 = The system speaks all telephone messages over the phone and at all control centers connected to the system. 2 = During telephone programming, press the [i] button to turn message announcements on or off at the control center. 142 Restrict Installer Passcode 151 Wireless Device Supervision Interval 162 Missing Wireless Device Conditions 0 = Master user not needed 1 = Master user needed 1= 1 Hour 2= 2 Hours 3= 4 Hours 4= 12 Hours 5= 24Hours 6= 2.5 Hours 0 = Missing conditions create a tamper condition (meets EN50131). 1 = Missing conditions create a trouble condition. 2017.01 02 F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH

Easy Series Control Panel Appendix en 15 System Programming s Programming 163 Silence Trouble Tones 0 = All trouble tones beep at the control center. 1 = Only Fire and 24-Hour trouble tones beep at the control center. 164 System Inactivity Time (Hours) 165 System Inactivity Time (Days) 166 System Inactivity Time (Weeks) Enter the number of hours (0-255) that the system must be off before it sends the System Inactive report. Enter the number of days (0-255) that the system must be off before it sends the System Inactive report. Enter the number of weeks (0-255) that the system must be off before it sends the System Inactive report. 167 Force Arm/Exit Error 0 = Off-normal points create an exit error at the end of Exit Delay 1 = Off-normal points are force-armed at the end of Exit Delay 168 Audio Verification Command Set 0 = Use SIA Standard Audio Verification commands (AV-01-1997.11) 1 = Use alternate audio verification command set 601 Enable Keyfob Duress 0 = Wireless keyfob does not send a Duress event 1 = Wireless keyfob sends a Duress event Audio Verification Commands SIA Standard Audio Verification Commands ( 168 = 0) Phone Button Command [1] Talk to premises. [3] Listen to premises. [6] Listen to premises. [7] Restart 90-second timer. [9][8] Terminate session with call back. [9][9] Terminate session without call back. [0] Listen to all microphones. [#] Cancels first digit of command. Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 02 F.01U.306.216

16 en Appendix Easy Series Control Panel SIA Standard Audio Verification Commands ( 168 = 0) Phone Button Command Alternate Audio Verification Commands ( 168 = 1) Phone Button Command [#] Talk to premises. [*] Listen to premises. [7] (any number 1 to 9) Restart 90-second timer. [0] Terminate session without call back. Route Destination s Programming 100 Account Number 4- or 6-digit number 201 Phone Line Supervision 0 = On 1 = Off 202 PSTN, IP or Cellular Connection 0 = PSTN telephone line 1 = B426, B450 205 Dial Tone Detect 0 = On 1 = Off Phone Number/IP Address for Route Destination: 206 Route 1 Primary 32 digits maximum 207 Route 1 Backup 0-9, B-F allowed.. = [*] (. between each IP address 208 Route 2 Primary notation). 209 Route 2 Backup Exit with save = [#] Exit without save = [#][#] 210 SMS Service Provider Disable phone number = [0][#] Disable IP address = 240.0.0.0 Format for Route Destination: 211 Route 1 Primary 0 = Disabled 212 Route 1 Backup 1 = Contact ID 2 = SIA 213 Route 2 Primary 3 = Voice 214 Route 2 Backup 4 = SMS 5 = Fast Format 6 = Network 215 Call Waiting Disable 3 or 4 digits * = [*][*]; # = [*][#] 216 Emergency Call Override 3-digit number 2017.01 02 F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH

Easy Series Control Panel Appendix en 17 Route Destination s Programming 217 Emergency Call Override Delay 0 to 60 min 218 Auto Detect Pulse Dial 0 = Tone dialing 1 = Pulse dialing 222 Phone Answer Ring Count 1 to 255 rings Alternate Communication s Programming Port Number for Route Destination: 241 Route 1 Primary 0 to 65535 242 Route 1 Backup 243 Route 2 Primary 244 Route 2 Backup Heartbeat for Route Destination: 281 Route 1 Primary 0 = Disabled; 1 to 65535 min 282 Route 1 Backup 283 Route 2 Primary 284 Route 2 Backup Acknowledge Wait Time for Destination: 285 Route 1 Primary 5 to 255 sec 286 Route 1 Backup 287 Route 2 Primary 288 Route 2 Backup Anti-Replay for Route Destination: 289 Route 1 Primary 0 = Disabled; 1 = Enabled 290 Route 1 Backup 291 Route 2 Primary 292 Route 2 Backup Heartbeat Attempt for Route Destination: Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 02 F.01U.306.216

18 en Appendix Easy Series Control Panel Alternate Communication s Programming 293 Route 1 Primary 1 to 99 294 Route 1 Backup 295 Route 2 Primary 296 Route 2 Backup 297 Extend Heartbeat Period 0 = Disabled; 1 to 255 min RPS Configuration s Programming 118 RPS Passcode 6 digits required, using 0 to 9 and A to F. 224 RPS Automatic Call In Frequency 0 = Never; 1 = Daily 2 = Weekly; 3 = Monthly 225 RPS Automatic Call In Time (Hours) 226 RPS Automatic Call in Time (Minutes) 227 RPS Automatic Call in Time (Day of Week) 228 RPS Automatic Call in Time (Day of Month) 229 RPS Automatic Call in Phone Number/IP Address 0 to 23 0 to 23 0 to 6, where 0 = Sunday and 6 = Saturday 1 to 28 Refer to Numbers 206-209 for allowed entries. 245 RPS Automatic Call in Method 0 = Phone number; 1 = IP address 246 RPS Port Number 0 to 655353 Point Report and Restoral Routing Programming Programming 301 Point Reports and Restorals(all) 326 Intrusion Zone Bypass 307 Intrusion Alarm 327 Intrusion Zone Bypass Restoral 308 Intrusion Alarm Verified 328 Fire Trouble 309 Intrusion Alarm Unverified 329 Fire Trouble Restoral 310 Intrusion Alarm 24-Hr 331 24-Hour Trouble 2017.01 02 F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH

Easy Series Control Panel Appendix en 19 Point Report and Restoral Routing Programming Programming 311 Intrusion Alarm 24-Hr Restoral 332 24-Hour Trouble Restoral 312 Intrusion Alarm Restoral 335 Supervisory Alarm 313 Duress 336 Supervisory Alarm Restoral 315 Fire Alarm 371 Fire Cancel 316 Fire Alarm Unverified 388 Point Tamper 317 Fire Alarm Restoral 393 Cross Zone Trouble 318 Panic 394 Alarm Recent Close 323 Cancel 399 Panic Restoral 324 Intrusion Trouble 400 Cross Zone Trouble Restoral 325 Intrusion Trouble Restoral : 0 = Neither Route, 1 = Route 1 only, 2 = Route 2 only, 3 = Both routes System On and Off (Open and Close) Report Routing Programming Programming 302 System On and Off Reports (all) 341 Open 314 Exit Error 342 Open Keyswitch 330 Recent Closing 343 Open Remote 337 Close (System On) Unoccupied 338 Close (System On) Occupied 344 Close (System On) Custom 386 Open by Guard Code 339 Close Keyswitch 403 Partial Close (System On) 340 Close Remote : 0 = Neither Route, 1 = Route 1 only, 2 = Route 2 only, 3 = Both routes System Report and Restoral Routing Programming Programming 303 System Reports and Restorals (all) 358 Low Battery 319 User Emergency 359 Low Battery Restoral Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 02 F.01U.306.216

20 en Appendix Easy Series Control Panel System Report and Restoral Routing Programming Programming 320 User Fire 364 Phone Line Fault Restoral 321 User Fire Restoral 372 Firmware Updated 322 User Panic 375 ROM Fault 345 AC Fail 376 Bell Trouble 346 AC Fail Restoral 377 Bell Restoral 347 Auto System Test Normal 378 Walk Test End 348 Auto System Test Off- Normal 379 Walk Test Start 349 Auxiliary Power Fault 380 Bus Device Missing 350 Auxiliary Power Restoral 381 Bus Device Missing Restoral 351 Communication Fail 382 Battery Missing 352 Communication Restoral 383 Battery Missing Restoral 353 Control Center Supervision Fail 354 Control Center Supervision Restoral 384 RAM Checksum Failed 385 System Inactive 355 Control Center Tamper 391 Passcode Tamper 356 Control Center Tamper Restoral 392 Watchdog Reset 357 Local Programming Success 410 Date/Time Changed 362 Communication Test Manual 413 Network Fail 363 Phone Line Fault 414 Network Restoral : 0 = Neither Route, 1 = Route 1 only, 2 = Route 2 only, 3 = Both routes Global Report Routing s Programming 304 Communicator Disable 0 = Enable reporting 1 = Disable reporting 305 Route Attempts 1 to 20 306 Send Report During Walk Test 0 = No 1 = Yes 2017.01 02 F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH

Easy Series Control Panel Appendix en 21 User Programming s Programming 861 Passcode Length 4 or 6 digits 862 User 22 Configuration 0 = User 22 is disabled 1 = User 22 is a duress user 2 = User 22 is a guard user 7001 Installer Passcode (User 0) 1111 to 555555 7011 Master User Passcode (User 1) Control Center Programming s Programming 888 Fire Button Alarm [1] key 0 = Disabled 889 Medical Button Alarm [1][2] keys 1 = Enabled 890 Panic Button Alarm [2] key 0 = Disabled 1 = Audible alarm 2 = Silent alarm 891 One Button Arming 0 = Disabled 1 = Enabled 892 Invalid Passcode Attempt Limit 3 to 8 893 Control Center Lockout Time 1 to 30 min Point Programming s Programming Point Type Point 01 = 9011 Point 32 = 9321 Circuit Style Point 01 = 9012 Point 32 = 9322 0 = Disabled 1 = Perimeter 2 = Interior 3 = Perimeter Instant 4 = 24-Hour Trouble 5 = Fire Verified 6 = Fire Instant 7 = Panic 8 = Interior Walkthrough 9 = Perimeter Exit Cancel 11 = Momentary Keyswitch 12 = Maintained Keyswitch 13 = 24-Trouble 14 = User Emergency 0 = Dual 2.2 kωalarm and tamper circuit 1 = Single 2.2 kωalarm circuit Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 02 F.01U.306.216

22 en Appendix Easy Series Control Panel Point Programming s Programming Alarm Verification Point 01 = 9016 Point 32 = 9326 0 = Disable audio alarm verification 1 = Enable audio alarm verification Programming Factory Default 9999 2017.01 02 F.01U.306.216 Quick Installation Guide Bosch Sicherheitssysteme GmbH

Easy Series Control Panel Appendix en 23 7.2 Country Codes Country Code Country Code Country Code Argentina 01 Germany 18 Norway 38 Australia 02 Greece 19 Poland 41 Austria 03 Hong Kong 20 Portugal 42 Belarus 62 Hungary 21 Romania 43 Belgium 04 India 22 Russian Federation 44 Bosnia 65 Indonesia 23 Spain 51 Brazil 05 Ireland 24 Sweden 52 Bulgaria 06 Israel 63 Taiwan 54 Canada 07 Italy 25 Thailand 55 China 08 Japan 26 Turkey 56 Croatia 10 Lithuania 29 Ukraine 62 Czech Republic 12 Luxembourg 20 United Arab Emirates 65 Denmark 13 Malaysia 32 United Kingdom 57 Egypt 14 Mexico 34 United States 58 Finland 16 Netherlands 35 France 17 New Zealand 36 7.3 Default Passcodes Passcode Default Installer Passcode (User 0) 5432(11) Master User (User 1) 1234(55) Guard Code (User 22) 1111(11) Bosch Sicherheitssysteme GmbH Quick Installation Guide 2017.01 02 F.01U.306.216

Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA www.boschsecurity.com Bosch Security Systems, Inc., 2016 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany