Dehumidifiers. Model 1830/1850/1850F/1850W. OTHER PARTS (Not Shown)

Similar documents
DEALER PARTS LIST DEHUMIDIFIERS. Model 1830/1850/1850F/1850W 17A 17B 17C

Model 1820 Dehumidifier

Model 1870F Dehumidifier Installation and Operating Manual

MODEL 1830/1850/1870 DEHUMIDIFIER APPLICATION QUICK START GUIDE

Model 1850F Dehumidifier Installation and Operating Manual

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 1870 & 1870W Dehumidifier Installation Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

Humidifiers Dealer Parts List Model 400/400M Humidifiers

Humidifiers Dealer Parts List

Humidifiers. Model 400/400M Humidifiers NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO.

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Safety and Installation Instructions Model 1700

S1-CVD070T01A / S1-CVD095T01A Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION

Installation, Safety & Maintenance Manual Model 1750A/1770A

Model 1750A/ 1770A Dehumidifier Installation Instructions

Air Cleaners Dealer Parts List

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest 105, Dry155, and 205 Dual

Quest Dry 105, 155, and 205 Dual

Model 76 Dehumidifier Control Installation Instructions

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Installation and Operation Manual

Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

Steam Humidifier Fan Pack Installation & Maintenance Instructions

Read and Save These Instructions

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Owner s Manual Phoenix 200HT

Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions

Owner s Manual Phoenix 250 MAX

S1-CD065T01 Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION SPECIFICATIONS LOCATION CONSIDERATIONS

Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions

DRY 150 Quest PowerDry 1300

Installation, Operation and Maintenance Instructions

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions

Hoshizaki America, Inc.

READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Installation & Operation Instructions

Safety & Installation Instructions

Owner s Manual Phoenix 250 MAX

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R175 LGR Dehumidifier. Installation, Operation & Service Instructions

Model 1730A Compact Dehumidifier Installation Instructions

Read and Save These Instructions

Dehumidifiers. Product Guide. Smaller. Quieter. Smarter.

Quest 215 DryDual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Installation & Operation Instructions

Model 8120 and 8126 Safety & Installation Instructions

Quest DRY quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest DRY 180:

Owner s Manual HI-E Dry Vehere

Parts List. Modular Crescent Cuber. Models KM-340MAJ, MWJ. hoshizakiamerica.com

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

Quest Dry Quest Dry 105, 155, and 205

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R250 LGR Dehumidifier. Installation, Operation & Service Instructions

Model 65 Humidifier Control Owner s Manual

Parts List. Low-Profile Modular Crescent Cuber. Models KML-325MAJ KML-325MWJ. hoshizakiamerica.com

Parts List. Modular Crescent Cuber. Models KM-515MAJ, MWJ, MRJ. hoshizakiamerica.com

INSTALLER S & OWNER S MANUAL

Parts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Owner s Manual Phoenix Arctic Max

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R175 LGR Dehumidifier. Installation, Operation & Service Instructions

Owner s Manual Phoenix R125 LGR Dehumidifier

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

Safety & Installation Instructions

Safety & Installation Instructions

(EE1500, EE2000, EE2500, EE3000)

DRY 150 Quest PowerDry 1300

Safety & Installation Instructions

Safety & Installation Instructions

Parts List. Low-Profile Modular Crescent Cuber. Models KML-500MAJ KML-500MWJ. hoshizakiamerica.com

Owner s Manual Phoenix 200 MAX

INSTALLER S & OWNER S MANUAL

Installation, Operating and Maintenance Manual

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R200 LGR Dehumidifier. Installation, Operation & Service Instructions

Installation & Operation Instructions

Installation & Operation Instructions

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

Model 75 Dehumidifier Control Owner s Manual

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

DSR SERIES DEHUMIDIFIERS ENGLISH GENERAL INFORMATION EXPLODED VIEWS DSR-20 DSR-12 PARTS LISTS ATTENTION!

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

Shelleybasic. Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 2016

REPLACEMENT PARTS MANUAL

Installation & Operation Instructions

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

Steam Humidification Light Commercial Applications. Better technology means better business.

REPLACEMENT PARTS LIST O4 Series Oil Furnace

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

Owner s Manual Ultimate 340

INSTALLER S & OWNER S MANUAL

Owner s Manual AF365

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

Transcription:

Effective Date: April, 0 Dehumidifiers Model 0/0/0F/0W A B 0 A B Filter, 0 x x EZK (0 & 0)* Filter, x x EZK (0F Only) Internal Control Board User Interface Assembly Wiring Access Door UI Control Hole Cover * Filter Access Door 0/0 Outlet Duct Panel * 0 Backflow Damper * Inlet Duct Panel * Outlet Cover * 0 Pint Dehumidifier Fan Pint Dehumidifier Fan Transformer and Wire Harness * Not Compatible with 0F **Drain tube only included with 0F 0 A B C 0A 0B Low Temperature Sensor High Temperature Sensor Leveling Foot* Compressor Run Capacitor, 0pt/pt, MFD, 0VAC Fan Run Capacitor, MFD, 0VAC, used on Models 0 and with Serial Number before 0A0 Fan Run Capacitor, MFD, 0VAC, used on Models 0 and with Serial Number 0A0 or later Fan Run Capacitor, MFD, 0VAC, used on Models 0(F)(W) and RH & Temp Sensor Drain Tube + Fittings** Compressor Overload Switch, 0pt Compressor Overload Switch, pt OTHER PARTS (Not Shown) Low Profile Condensate Pump Basement Kit (-0 N/O Dampers, -0 N/C Dampers & Transformer) Digital Dehumidifier Control (for all current dehumidifiers) Living Space Duct Kit ( of insulated flex duct with quick install grilles and reducers) Dehumidifier Hanging Kit 0 0 P.O. Box Madison, WI 0- Phone: 00/-0 Fax: 0/- www.aprilaire.com Form No. 0B. Printed in the U.S.A 0 Aprilaire Division of Research Products Corporation

Model 0/0F/0W A B 0 Filter, x x EZK (0) Filter, x x EZK (0F) Internal Control Board, Deh User Interface Assembly, Deh Wiring Access Door, AA Deh Hole Cover, UI Ctrl, Deh Door, Filter Access, AA Deh Outlet Duct Panel, Deh Backflow Damper, 0, Deh Inlet Duct Panel, AA Deh Cover, Outlet, AA Deh 0 0 A B 0 Fan, 0pt Deh, with 0MFD Capacitor (0) Wire Harness, Power, Deh Sensor, Low Temperature, Deh Sensor, High Temperature, Deh Leveling Foot, Deh Capacitor, 0MFD, 0VAC Capacitor, 0MFD, 0VAC Capacitor, MFD, 0VAC RH Sensor, Deh Drain Tube + Fitting Compressor Overload Switch 0

Model 0A with R0A A B 0 Dehumidistat Control Assembly Digital Dehumidifier Control Backflow Damper Impeller with Bracket (Blower Assembly) Leveling Foot Control PCB Assembly High Temperature Cutout Switch Low Temperature Cutout Switch Filter Access Door Assembly Dehumidistat Hole Cover Outlet Cover Plate Air Filter Inlet/Outlet Screen Duct Collars Auxiliary drain pan Capacitor, µf Compressor Overload Switch Condensate Drain Hose Assembly 0VA Transformer with Wire Harness Capacitor, 0MF for Impeller OTHER PARTS Low Profile Condensate Pump (Condensate pump with 0 condensate hose) Living Space Duct Kit ( of insulated flex duct with quick install grilles) Living Space Duct Kit ( of insulated flex duct with quick install grilles and reducers) Part No. replaced by Part No. replaced by 0 0 0

Model 0A/0A/0A

PART NO. A B 0 A B A B Filter Drain Trap/Collars/Manual Backflow Damper * Blower/Motor Assembly, 0A/0A and 00/0/0 Blower/Motor Assembly, 0A and 0/0 Power Supply Board Power Supply Board (new style without integrated transformer) Control Board Kit *** Sensor Board Duct Collars Drain Trap and PVC Elbow Filter Door ** Condensate Drain Hose Assembly (included with Model 0A only) LED Control Door 0 VA Transformer Capacitor, 0µF (Model 0A only) Capacitor, µf Daughter Board High Temperature Cutout Switch Compressor Overload Switch, 0A/0A Compressor Overload Switch, 0A Frost Sensor OTHER PARTS External Control **** Convertible Installation Kit (-N/O Damper, -N/C Damper and Transformer) Distributor and nozzle, 0A/0A Low Profile Condensate Pump (condensate pump with 0 condensate hose) Living Space Duct Kit ( Of Insulated Flex Duct With Quick Install Grilles) Living Space Duct Kit ( of insulated flex duct with quick install grilles and reducers) Identifying Type of Control by Terminal Block Model 0A/0A/0A Model 00/0/0/0/0 0 See Table Below * The backflow damper (Part No. ) is compatible with all Models 0A, 0A, but only with Model 0A with Serial Numbers greater than 0AA0. ** Part is the blue/gray door; the almond colored doors are no longer available. *** If control board being replaced is currently used with a Model 0 Control, the control must be replaced with a Model Control. **** Only use a Model 0 Control to replace an existing Model 0 control with units produced before Serial Number 0AAXXXXXX. NO. PART DESCRIPTION Compatible With QTY/CTN PART NO. A Power Supply Board Control Board without DH Terminal B Power Supply Board (new style without integrated transformer) Control Board with DH Terminal 0 DH Terminal implemented on all units with Serial Number 0AAXXXXXX or later. 0 0 0 P.O. Box Madison, WI 0- Phone: 00/-0 Fax: 0/- www.aprilaire.com Form No. 0B. Printed in the U.S.A 0 Aprilaire Division of Research Products Corporation