S1-CD065T01 Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION SPECIFICATIONS LOCATION CONSIDERATIONS

Similar documents
Model 1730A Compact Dehumidifier Installation Instructions

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

S1-CVD090T01 / S1-CVD135T01 Central Ventilating Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION

Model 1820 Dehumidifier

Model 1750A/ 1770A Dehumidifier Installation Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Safety and Installation Instructions Model 1700

S1-CVD070T01A / S1-CVD095T01A Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION

Model 1870F Dehumidifier Installation and Operating Manual

Model 1870 & 1870W Dehumidifier Installation Instructions

Installation, Safety & Maintenance Manual Model 1750A/1770A

Model 1850F Dehumidifier Installation and Operating Manual

Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

INSTALLATION MANUAL MODULAR VARIABLE SPEED AIR HANDLERS MODELS: MV LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

Automatic Digital Humidifier Control

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

INSTALLATION INSTRUCTIONS Apartment Fan Coil

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

Quest 105, Dry155, and 205 Dual

Installation, Operation and Maintenance Instructions

Installation Instructions

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Quest Dry 105, 155, and 205 Dual

Model 76 Dehumidifier Control Installation Instructions

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

Dehumidifiers. Model 1830/1850/1850F/1850W. OTHER PARTS (Not Shown)

5.0 AIR HANDLER EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM INTERFACE BOARD

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

ZONE PANEL KIT INSTALLATION MANUAL COMMUNICATING ZONE PANEL KIT - (S1-TCZCB01A) ZONE PANEL WITH ZONING TOUCH SCREEN FIRMWARE

Operator: Save these instructions for future use!

Installation Instructions

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Installation Instructions

Model 8120 and 8126 Safety & Installation Instructions

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Installation Instructions / User s Manual NAXA00101DB Communicating Daughter Board

Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions

Installation & Operation Instructions

Read and Save These Instructions

INSTALLATION INSTRUCTIONS Fan Coils FVM2X, FVM4X

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Quest DRY quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest DRY 180:

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F6FP018** - 060** TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0409

Installation & Operation Instructions

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

Desiccant Dehumidifier

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

5.0 AIR HANDLER Comfort Control 2 System INTERFACE BOARD

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

MX Series Indoor Modular Blowers ModuleFlex Electric or Hot Water Heat with available Variable-Speed High Efficiency ECM Motor

Read and Save These Instructions

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Quest Dry Quest Dry 105, 155, and 205

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F*FP LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0209

Installation Instructions WARNING WARNING. Variable Speed High Efficiency Blower Kit for Gas Furnace Applications 3. INSTALLATION

Owner s Manual Ultimate 340

DEALER PARTS LIST DEHUMIDIFIERS. Model 1830/1850/1850F/1850W 17A 17B 17C

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

INSTALLATION INSTRUCTIONS Fan Coils FVM4X B Series

Owner s Manual HI-E Dry Vehere

TrueSTEAM. 1 Mount 2 Hang. 3 Plumb 4 Wire. As Easy as PROFESSIONAL INSTALLATION GUIDE

INTELLIMIST Residential Atomizing Humidifier and Control

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions

Quest 215 DryDual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Installation. Table of Contents. 1. Description/ Application. Form I-CAUA-CC (04-15) Obsoletes Form I-CAUA-CC (Version C.1)

Owner s Manual Phoenix 250 MAX

INSTALLATION INSTRUCTIONS Fan Coils FEM4X, FSM4X, FSU4X, FXM4X

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

DDNECNJ SEQUENCE OF OPERATION This sequence assumes employment of a single enthalpy economizer using a two stage thermostat.

HRV Vertical Unit Ventilators

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

INSTALLATION AND MAINTENANCE INSTRUCTIONS. MCE4 Series. Electric Cooling Package Unit. Save these instructions for future reference

Installation Instructions

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

Installation, Start-Up, and Service Instructions

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

Owner s Manual Phoenix 250 MAX

INTELLIMIST HUMIDIFIER

INSTALLATION INSTRUCTIONS Fan Coils FEM4X, FSM4X, FSU4X, FXM4X

Installation Instructions Owner s Manual

HR150B, HR200B Perfect Window Fresh Air Ventilation Systems

DDNECNJ SEQUENCE OF OPERATION This sequence assumes employment of a single enthalpy economizer using a two stage thermostat.

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Install Guide 3M-10 ENGLISH

Installation, Operating and Maintenance Manual

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

How to add or upgrade residential & commercial equipment without installing new cables. How to test & repair cables.

Model CZ-4. Installation and Operating Instructions. FORM White-Rodgers by Permission B

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

π H-6369, H-6370 DEHUMIDIFIER GENERAL INFORMATION uline.com WATER IN THE BUCKET RECOMMENDED HUMIDITY LEVELS WARM AIR EXHAUST IS NORMAL

DRY 150 Quest PowerDry 1300

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

TrueDRY DR90 PROFESSIONAL INSTALLATION GUID OPTIONAL CONTROLS SOLD SEPARATELY

Transcription:

Johnson ontrols Unitary Products S1-D065T01 entral Dehumidifier Installation Instructions WANING 1. 120 volts may cause serious injury from electric shock. Disconnect electrical power before starting installation. Leave power disconnected until installation is complete. 2. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling ductwork. 3. Dropping may cause personal injury or equipment damage. Handle with care. 4. Do not remove the outlet screen. The screen is required to protect from moving parts and electrical components. AUTION 1. Do not use in pool applications. 2. If unit has been shipped or stored on its side, wait 24 hours before running. 3. Do not use solvents or cleaners on or near the circuit board. SPEIFIATIONS Dimensions: Width: 12.5 cabinet, 13 with doors Height: 14.5 cabinet, 18.5 with leveling feet fully extended Length: 22 cabinet, 27 with collars Weight: 65 lbs. apacity: 65 pints/day @ 150 cfm AHAM DH-1-2003 80 F, 60% H conditions Efficiency: 1.8 Liters per kilowatt hour AHAM DH-1-2003 80 F, 60% H conditions Power: 115VA, 60 Hz, 8A Operating urrent Unit equipped with 8 ft. grounded power cord 15 Amp circuit required Airflow: P ("w.c.) Airflow (cfm) 0 230 0.25 190 0.50 150 Inlet Air Operating onditions: 60 F to 95 F, 30% H to 99% H Installation onditions: 40 F to 140 F, 0% H to 99% H Evaporator Frost Sensor: 25 F +/- 5 F, circuit opens (cut-out) 55 F +/- 5 F, reset temperature (cut-in) Filter: MEV 8, washable LOATION ONSIDEATIONS 1. Install Unit Indoors: Do not expose to elements. 2. Drain Accessibility: If a drain is not located in the installation area, a condensate pump may be required. 3. Power: Outlet within 8 feet of unit. 4. Filter Access: Allow for 12 clearance on one side of the unit for removal of filter. (Figure 1) 5. Inlet: If inlet is not ducted, a minimum of 6 of open space is required from the inlet panel to an adjacent surface. Figure 1 Filter Access learance 90-1426 TOP VIEW FILTE 6" MINIMUM LEAANE FO POPE AI FLOW 12" MINIMUM LEAANE FO FILTE (EITHE SIDE) UNPAKING AND ONTENTS Do not tip unit to remove from carton. 1. Open carton completely using cut line shown along bottom perimeter of carton. 2. emove all cardboard inner pack (top edges and duct collars). 3. See Figure 2 for opening view and contents. a. Installation Manual b. Owner s Manual c. Knob Setpoint Insert Sheet d. Dehumidistat (mounted to inlet panel) e. Bag with Dehumidistat over Plate, Screws (2), Anchors (2) f. Outlet with Back Flow Damper g. 8 ft. Grounded Power ord h. Wiring Access Panel i. ondensate Pan Figure 2 arton Opening & ontents 90-1464 i f g a b c d e h

SET-UP Supply ollar The dehumidifier can be installed as shipped, with the supply collar on the outlet panel, or if space is restricted, the supply collar can be relocated to the top of the unit. Top Mount Supply ollar (Figure 3) 1. emove the four screws securing the supply collar (with backflow damper) and screen to the outlet panel. 2. emove the four screws securing the top mounted outlet cover plate. 3. Attach screen and supply collar with damper to the top of the unit. 4. Attach outlet cover plate to the outlet panel. Figure 3 Top Mount Supply ollar Supply collar mounted to top of unit Dehumidistat Location The dehumidistat mounted to the dehumidifier can remain on the unit or be removed and mounted in the living space. Attic installations require that the dehumidistat be moved to the living space. Note: Any dry contact, normally open humidity control can be used as the controlling device for the dehumidifier, thermostat S1-TTS01 is recommended. For removal and relocation of the dehumidistat or if using a S1-TTS01 thermostat, see the WIING, ONBOAD DEHUMIDISTAT WALL MOUNT INSTALLATION and S1-TTS01 WIING sections. Outlet cover plate moved to outlet panel Wall Mount Location Mount approximately 5 feet above the floor on an inside wall of the living space. Do not locate dehumidistat in the direct path of drafts from open doors and windows. Do not install where operation might be affected by lamps, outside sources of humidity (i.e. shower), fireplace, registers, or radiators. OUTLET VIEW 90-1425 MEHANIAL INSTALLATION Drain un vinyl or pvc tubing from the 3/4 drain outlet on the dehumidifier inlet to a floor drain. Make sure the drain line has a constant downward slope and is not kinked. efer to local codes to determine if a p-trap is required. In attic installations the supplied condensate pan with a field supplied float switch is required. See ondensate Pan and Float Switch section for installation and wiring instructions. Suspended Installation If hanging the unit, use 1/4 threaded rod and two unistruts to support the base just inside the leveling feet. It is recommended that vibration isolators be placed between the unistruts and dehumidifier base. See Figure 4. Do not position threaded rods over filter access doors. There must be a minimum clearance of 12 on one side of the unit to allow for removal of the filter. Figure 4 Suspended Installation FILTE AESS DOO 5-1/8" OUTLET INLET 90-1427 VIBATION ISOLATOS 2-1/8" LEAANE FO LEVELING FEET 2

Ducting The dehumidifier is supplied with two 8 round collars. An integral backflow damper is installed in the outlet collar. In a ducted installation, the dehumidifier pulls air from the living space or HVA return duct and supplies the dehumidified air to the HVA supply duct (See Figures 5, 6 & 7). Ducted Installation Move supply collar to the desired location, if necessary. (See Supply ollar in SET-UP section.) The unit can be ducted to the supply or both the return and supply. The dehumidifier inlet ducting must be a minimum of 6 upstream of the HVA system air cleaner and the outlet must be ducted a minimum of 6 downstream of the cooling coil. An additional option is to duct the dehumidifier inlet and outlet to the return duct. This installation must include wiring the dehumidifier to activate the HVA blower during dehumidification. (See Wiring to HVA System in WIING section.) Use the least amount of ductwork possible. To ensure best performance, do not exceed a total of 50 feet of duct installed in accordance with SMANA Standards. UL approved, 8 diameter, insulated duct is recommended for all connections. All joints and seams must be sealed. Figure 5 Basement Installation Figure 6 Equipment oom/loset Installation DEHUMIDIFIED AI IS SUPPLIED DOWNSTEAM FOM A-OIL TO MINIMIZE EVAPOATION OFF A-OIL SUPPLY DUT A-OIL SUPPLY DUT DEHUMIDIFIED AI IS SUPPLIED DOWNSTEAM FOM A-OIL TO MINIMIZE EVAPOATION OFF A-OIL ETUN DUT A-OIL HVA / FUNAE HVA / FUNAE 115 VA IUIT 115 VA IUIT AI IS PULLED FOM MAIN ETUN DUT NOTE: DO NOT BLOK FUNAE AESS ONDENSATE HOSE (TO OMMON DAIN O OUTSIDE) DEHUMIDISTAT WITH SET POINT KNOB NOTE: DAWS AI FOM LIVING SPAE THOUGH ETUN GILL ONDENSATE HOSE ON (TO OMMON DAIN O OUTSIDE) AUTION Ensure return grill in door is not obstructed so dehumidifier does not pull from HVA system. Figure 7 Attic Installation DEHUMIDIFIED AI IS SUPPLIED DOWNSTEAM FOM EVAPOATO OIL TO MINIMIZE EVAPOATION OFF OIL 115 VA IUIT AI FILTE AESS DOO ONDENSATE PAN AND FLOAT SWITH ELOATE DEHUMIDISTAT TO LIVING SPAE MAIN SUPPLY DUT HVA EVAPOATO OIL HVA/FUNAE SYSTEM SHOWN IN HOIZONTAL OIENTATION ONDENSATE HOSE (TO OMMON DAIN O OUTSIDE) MAIN ETUN DUT Note 1: Attic installations require the following. 1. The dehumidistat must be removed from the unit and relocated in the living space. An insulated cover plate is provided to cover the dehumidistat opening. 2. The dehumidifier must be installed in the supplied condensate pan with a field supplied float switch. Note 2: Vibration isolators placed under the dehumidifier feet are recommended when the dehumidifier is installed on ceiling joists. PINIPAL LIVING SPAE 3

Stand Alone Installation In a free standing installation, the dehumidifier pulls air from the installed space and returns the dehumidified air back to that space. See Figure 8. Place unit in area with drain access and within 8 of an outlet. Unit can also be ducted to pull and return to a single living space. See Figure 9. Figure 8 Stand Alone, Non-Ducted Figure 9 Stand Alone, Ducted ETUN DUT OUTSIDE AI TO HOUSE ETUN DUT OUTSIDE AI TO HOUSE SUPPLY DUT SUPPLY DUT LIVING SPAE HVA / FUNAE 115 VA IUIT DEHUMIDIFIED AI IS SUPPLIED TO INSTALLED SPAE ONTOL 115 VA IUIT ELOATE DEHUMIDISTAT TO LIVING SPAE AI IS PULLED FOM INSTALLED SPAE FLOO DAIN ONDENSATE HOSE (TO OMMON DAIN O OUTSIDE) FLOO DAIN ONDENSATE HOSE (TO OMMON DAIN O OUTSIDE) AUTION Ensure air circulation is maintained in installed space so dehumidifier does not pull from HVA system. Figure 10 Leveling Leveling The feet can be adjusted to level the unit and/or to accommodate a p-trap. Leveling is required to ensure proper drainage from the dehumidifier. See Figure 10. 7/8" MINIMUM 4" MAXIMUM 90-1498 WIING Wiring To HVA System The dehumidifier can be wired to activate the HVA blower during dehumidification. This is recommended because it offers better circulation and balancing of the indoor air conditions. Note: unning the HVA blower during dehumidification does not affect moisture removal efficiency. If the unit is not wired to the HVA system, air is pulled through the unit, dehumidified, and circulated solely by the dehumidifier blower. HVA Wiring Instructions 1. Disconnect power to the HVA system using disconnect switch or fuse/breaker. 2. Unplug the dehumidifier. 3. emove wiring access panel on the dehumidifier outlet panel. 4. un a 3-wire cable from the dehumidifier to the furnace/air handler. 5. Unplug the G-STAT, -HVA, & G-HVA terminals. Make the connections shown in Figure 11. 6. Plug terminals back into circuit board. 7. eplace the wiring access panel when wiring is complete. Figure 11 DEH/HVA Wiring Instructions THEMOSTAT G W Y HVA EQUIPMENT G W Y IUIT BOAD TEMINALS G STAT HVA G HVA 90-1424 4

ONBOAD DEHUMIDISTAT Wall Mount Installation (Figure 12) 1. Gently pull knob (A) from the dehumidistat cover (B). The cover is held in place by snap clips. emove the cover by pulling carefully. Do not touch the sensing element on the dehumidistat (). 2. emove 4 screws in base plate (D) and save for attaching the provided cover plate in place of the dehumidistat. 3. Pull dehumidistat off unit until 4-6 of wire is outside of unit. 4. ut wires and use metal tape to secure leads to inside of unit, preventing contact with blower. 5. emove the gasket from the base plate. This will be used with the insulated cover plate installed in the next step. 6. Using the screws removed in Step 2, install the provided insulated cover plate with gasket over the dehumidistat opening on the unit. 7. emove the wiring access panel on unit outlet panel. 8. Unplug the EMOTE terminals from the circuit board, remove the two wires and cut off bare leads. Once cut, the wires may remain in the unit. 9. un a 2-wire cable (18-22AWG) from the dehumidifier to the wall mount location. 10. onnect cable at the dehumidifier to the EMOTE terminals. Plug terminals into the circuit board and replace wiring access panel. See Figure 13. 11. Use the dehumidistat base as a template to mark mounting holes and wire access location on the wall. 12. Drill two 3/16 holes at mounting locations and a 3/8 hole at desired wire access location. 13. Pull 2-wire cable from the dehumidifier through the wire access opening in the wall. 14. Strip wire ends coming from the dehumidistat and dehumidifier and connect with small, field supplied wire nuts. 15. Push excess wire and wire nuts through the access hole in the wall. Use the supplied screws (E) and wall anchors (F) to attach the base plate (with dehumidistat) to the wall using the top centered hole and bottom centered slot. 16. eassemble dehumidistat cover by snapping in place on base plate and press on knob. Figure 12 Wall Mount KNOB A OVE B BASE PLATE D BASE PLATE D DEHUMIDISTAT ANHO F (x2) SEW E (x2) UT WIES 4-6 LENGTH 90-1466 Figure 13 Dehumidistat to Unit Wiring 90-1465 5

S1-TTS01 WIING 1. epeat steps 1-8 in the ONBOAD DEHUMIDISTAT WALL MOUNT INSTALLATION section. 2. See Figure 14 to wire the S1-TTS01 thermostat and S1-VENTDEH01 to the dehumidifier. Figure 14 S1-TTS01/ S1-VENTDEH01 to Unit Wiring TOUH SEEN OMMUNIATING ONTOL S1-VENTDEH01 VENT ONTOL IUIT BOAD A A OM FLOAT SWITH B B A OPN DEHUM TEMINALS LS OM EMOTE G-STAT -HVA G-HVA B OPN 90-1537 ONDENSATE PAN AND Float Switch If the dehumidifier is installed in an attic or an area requiring leak protection, the unit must be placed the supplied condensate pan with a field supplied normally closed condensate overflow safety switch (float switch). The float switch should be wired to the FLOAT SWITH terminals on the circuit board on the outlet panel. The compressor is disabled when the float switch is open. ONDENSATE PAN INSTALLATION 1. aise the unit so that the bottom of the dehumidifier drain tube is at least 2 off the floor (see Figure 15) and so that the dehumidifier is level front to back and side to side. 2. Install the dehumidifier so that all four sides of the dehumidifier and the drain tube are inside the condensate pan (see Figure 15). Figure 15 Install Dehumidifier in ondensate Pan FLOAT SWITH INSTALLATION AND WIING 1. Install a float switch (field supplied) on any side of the condensate pan. efer to the instructions provided with the float switch for proper installation. 2. The wires from the float switch are to be routed through the wiring access panel in the back of the dehumidifier (see Figure 15). emove the wiring access panel and pull the FLOAT SWITH terminal block off the circuit board. emove the float switch jumper wire and wire the float switch to the FLOAT SWITH terminals. Plug the terminal block back into the circuit board (see Figure 16). MODEL 065 Figure 16 Wiring Float Switch to Dehumidifier ontrol Board TO FLOAT SWITH 2" 2" 2" FLOAT SWITH (FIELD SUPPLIED) ONDENSATE PAN 2" 2" MIN. LEVELING FEET (4) 90-1475 90-1475 6

WIING SHEMATI Figure 17 Wiring Schematic Item Description QTY 1 ompressor Harness 1 2 High Temp utout Switch 1 3 utout Switch, Low Temp 1 4 ontrol Harness 1 Item Description QTY 5 Jumper Wire 1 6 Impeller Jumper Wires 1 7 Transformer 1 ompressor 2 3 ontrol PB Assy un apacitor for ompressor org S red brn red 5 LEDs HVA DEH OMP 4 1 blu 6 brn ylw org brn Humidity ontroller 7 grn/yel brn brn Power ord Screw Gnd to Base grn wht blu blu wht Impeller Screw ground terminal to electrical plate. 10 MFD capacitor On-Off Switch 90-1602 STAT UP/SYSTEM HEKOUT 1. heck the wiring and restore power to the HVA equipment (if applicable). 2. Plug in the dehumidifier and turn on/off switch ON. 3. heck LED indicators located below the wiring access panel. Verify the green LED is on. The green LED is on when power is applied to the system. 4. otate the dehumidistat knob fully clockwise to ON position. 5. If setup is correct, the dehumidifier blower, and HVA fan (if applicable) will turn on. The compressor will turn on after the dehumidifier blower has run for 3 minutes. efer to the TOUBLESHOOTING GUIDE if the dehumidifier blower and/or compressor do not activate. 6. heck LED indicators. Green should remain on. If ed LED is on, refer to the TOUBLESHOOTING GUIDE. The red LED turns on when a fault condition is active. Possible fault conditions include open float switch or open high temperature switch. 7. After verifying operation, rotate the dehumidistat knob counterclockwise to set the dehumidifier to the desired dryness level. Start at 2-1/2 as the initial setpoint for economy, property protection and upper end of comfort range. hange dryness level up or down as desired for comfort or economy. This will vary depending on location and conditions. Moving the knob toward MOE DY will increase the amount of time the dehumidifier runs, making conditions dryer. Moving the knob toward LESS DY reduces the amount of time the dehumidifier runs, allowing for higher humidity levels. See Figure 18 for knob setpoint. Figure 18 Dehumidistat Setpoints 90-1490 7

SEQUENE OF OPEATION The dehumidistat continually measures the humidity of the air in which it is located and controls to the dryness level set on the dial. When the humidity level rises above the dial setting on the dehumidistat, the dehumidifier blower will turn on and the DEH Amber LED on the power board (not visible unless dehumidifier cover is removed, see wiring schematic) will illuminate. The HVA system blower, along with the HVA Amber LED (not visible unless dehumidifier cover is removed, see wiring schematic) will also turn on if the dehumidifier is wired to the HVA system. After three minutes of blower operation, the dehumidifier compressor will turn on along with the OMP Amber LED (not visible unless dehumidifier cover is removed, see wiring schematic). When the humidity level drops below the dial setting on the dehumidistat, both the compressor and dehumidifier blower will turn off. If wired to the HVA system, the HVA blower will also turn off unless the system thermostat keeps it running. To prevent short-cycling, the compressor will turn on 3 minutes after the blower. The dehumidifier is equipped with an automatic defrost feature. When the evaporator coil temperature drops below the cut-out point of the frost sensor, the dehumidifier begins the defrost cycle and the dehumidistat will turn off the compressor and the blower will continue to run. The compressor will remain off until the evaporator coil temperature rises above the cut-in point of the frost sensor. TOUBLESHOOTING GUIDE Technical Support is available Monday through Friday, 8:00 a.m. to 5:00 p.m. ST, at (877) 874-7378. Use the troubleshooting guide to help find and correct system faults. ontact Technical Support before replacing the unit or components or for additional troubleshooting. Symptom ed LED On Blower & compressor not running. ed LED On Blower is on but compressor not running. Dehumidifier blower is running but little or no airflow. Blower is running but compressor is not. Dehumidifier is not draining properly. The dehumidifier does not run. Dehumidifier is loud when operating. Dehumidifier is producing hot air. Form 665507-UIM-A-0311 10009029 B2205176B 3.11 Possible eason/troubleshooting Procedure Open Float Switch If float switch not installed, confirm jumper installed at FLOAT SWITH terminals. If float switch installed, confirm switch is not open. lear obstruction in drain pan/tubing. High System Pressure/High Discharge Line Temperature Due to Lack of Airflow or Excessive Inlet Temperature heck dehumidifier air filter and wash or replace. heck for blocked ductwork and clear. Pressure Drop Across Dehumidifier is Higher than 0.8 w.c. heck dehumidifier air filter and wash or replace. heck for blocked ductwork and clear. heck if back flow damper is blocked or stuck and remove obstruction. oil Frosting Lack of or reduced airflow, check/clean filter. Inlet air conditions too low (below 60 F), turn down dryness setting. Blower 3 Minute Minimum ON Time Wait 3 minutes. ompressor will not start until blower has run for 3 minutes. Incorrect Drain Installation heck drain line for continuous downward slope. Verify there are no kinks, traps or debris in drain line. If drain trap installed, confirm trap is properly installed, clear and primed. Unit is not level, adjust feet. No Power to Unit Green LED Off (15 amp circuit required). heck that the power switch on the dehumidifier is ON. heck if circuit breaker has tripped. Dehumidistat is OFF Turn on dehumidistat. Fan Noise If inlet is not ducted to HVA return, install approximately 2 of 8 flex duct on inlet collar. Vibration Install vibration isolators under dehumidifier feet. This is normal operation. Johnson ontrols Unitary Products 5005 York Drive, Norman, OK 73069