INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien

Similar documents
GDDEM10 DEHUMIDIFIER

IMPORTANT SAFETY INSTRUCTIONS

Dehumidifier. Instruction Manual. Model DH-320/A

30-pint Dehumidifier User Guide

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

INSTRUCTION MANUAL EPH-121 CONTENTS

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

12L Dehumidifier Model: HG00923

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

OWNER S MANUAL. Portable Dehumidifier: BHD-H Series BHDP-H Series R-410A

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

USER INSTRUCTIONS FOR 0.25 LITRE MINI DEHUMIDIFIER - MODEL NO. DHMD025

This dehumidifier is both compact and lightweight. The casters on the bottom of the unit make it easy to move from room to room.

Ultrasonic Aroma Diffuser AD-SD1-CE

OPERATING INSTRUCTIONS

User s Manual. Electric Kettle Model MJ-EK5AEU (UK) Household Use

Up to 60 Pint Commercial Grade DEHUMIDIFIER

DEHUMIDIFIER USER MANUAL 95 PINT FOR MODEL: 3PAD95. Quick Start Tips on Page 1 COMFORT...BUILT TO LAST

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL

PORTABLE DEHUMIDIFIER

DAIKIN ROOM AIR CONDITIONER. Operation Manual

Air Dehumidification System. Instruction Book CLI-DH8D

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

Outdoor Beverage Center

Bar Fridge USER MANUAL MB46W

Portable Air Conditioner User Manual

INSTRUCTION MANUAL Model: SU3022

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Air always contains a certain amount of water in the form of vapour. This determines the

INDOOR UNIT/OUTDOOR UNIT

THERMO POT MODEL: ETP-D4013(WH)/ ETP-D5013(WH)/ ETP-D6013(WH) Owner s Manual. Please read this manual carefully before operating your set.

WCD-210BK. Water Dispenser OWNERS MANUAL. Read and save these instructions.

SYSTEM Inverter Air Conditioners

THERMO POT MODEL: ETP-C3211(WH) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

NEXXOS INVERTER USER MANUAL

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

INDOOR UNIT/OUTDOOR UNIT

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Inverter Split-type Room Air Conditioner

PORTABLE AIR CONDITIONER

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

PORTABLE AIR CONDITIONER (LOCAL)

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

- website: Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire WR9 0QH, UK

SYSTEM Inverter Air Conditioners

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

Operating Instructions

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

Instruction Manual Lantern / Design by Carsten Jörgensen

DEHUMIDIFIER INSTRUCTION MANUAL. Table of Contents. English. Italiano. Svenska. Features Powerful Dehumidifying Drying inside Easy Dehumidifying

Operating Instructions

SPLIT TYPE. Instruction manual

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer. Vax Careline: AU: NZ: VCWRS700

PUGMILL/MIXER. Instruction Manual NVS-07

Operating Instructions Air Conditioner

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

PDA20DX Air Purifying Dehumdifier Manual

WCD-200W Water Dispenser

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

π H-7147 SANITAIRE EON QUIET CLEAN VACUUM SAFETY uline.com

USER MANUAL. FairWind FWPC6L Pressure Cooker. Contact Us:

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

Local air conditioner

DEHUMIDIFIER USER S MANUAL CFO-12E CFO-20E

Portable Ice Maker User Guide

IMPORTANT SAFETY INSTRUCTIONS

MD2000 Dehumidifier with 2 litre Tank USER MANUAL

Carpet washer. vax.co.uk. W91-RS-B Series W90-RS-B Series. Vax Careline: (UK) (ROI) Vax model number: Version 1.

Installation/Instruction Manual

Owner s Manual Super-Slim Four-Way Cassette

VACUUM CLEANER USER GUIDE

MODEL MC-UL592 MC-UL594 POWER SOURCE. 230V - 240V ~ 50 Hz MAX INPUT 1400 W 1500 W NOMINAL INPUT DIMENSIONS (W x L x H)

Model: AW600. Triple Action Humidifier. Winix Inc. 120 Prairie Lake Road U nit E East Dundee, IL USA

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

AC-12200E Portable Air Conditioner

Warranty: Before operating this product, please read the instructions carefully and save this manual for future use.

SH3020 USER INSTRUCTIONS

SYSTEM Inverter Air Conditioners

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXSQ36MVJU FXMQ36MVJU FXSQ48MVJU. MODELS Ceiling-mounted Duct type. Ceiling-mounted Built-in type

Owner s Guide. Powerhead Canister Vacuum Cleaner

OPERATING INSTRUCTIONS

π H-2268 SANITAIRE UPRIGHT VACUUM SAFETY uline.com

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

Dimplex Air Conditioner DAC 12000R

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD

Dehumidifier Owner s Manual Read and save these instructions before use

Transcription:

INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien 41

INSTRUCTION BOOK Thank you for purchasing our product. Please read this owner s manual carefully before using the unit. It is important that you handle and use the unit according to the instructions, to ensure its long life, and to avoid problems and accidents. After reading this guide, keep it for future reference. Table of contents Before use Safety precautions --------------------------------------------------- 29 Names of parts ---------------------------------------------------------- 33 General precautions ------------------------------------------------ 34 How to use How to operate -------------------------------------------------------- 35 How to drain water --------------------------------------------------- 36 Maintenance and care ---------------------------------------------- 37 Specifications ----------------------------------------------------------- 38 Troubleshooting ------------------------------------------------------- 39 Draining of water directly to waste ---------------------- 40 Disposing of this product ---------------------------------- 40 Notice Ambient temperature will rise whilst the unit is on, due to the heat generated from the unit. During operation, you will get better drying efficiency by minimizing the opening/closing of windows and doors in the room. What is a "Desiccant system"? It is a next-generation, FREON -FREE dehumidification system for minimizing impact on the global environment. Micro pores of special zeolite material absorb moisture from the air and dry air is blown out. Trapped moisture is changed to water drops using heat from the heater, and retained in the water tank. 28

Safety precautions Follow these precautions strictly. This section explains precautions to be observed to prevent injury to user and/or other people and damage to your property. The severity of hazard and damage resulting from ignoring the precautions, or incorrect use of the products, are grouped and explained under the following headings. Warning Caution Sections under this sign indicate "a potentially hazardous situation that could result in death or serious injury". Sections under this sign indicate "a potentially hazardous situation that may result in moderate injury or property damage only". The precautions to be observed are grouped and explained under the following alert symbols. (The following symbols are examples.) This symbol indicates the actions that are prohibited. Warning Do not damage the power cord or plug. * Do not damage, modify, bend, twist, or stretch power cord, or plug-in forcibly. Do not put heavy objects on the plug or the cord. Do not bunch the cord with a cable-tie or wire. Use of a damaged cord or plug may lead to an electrical shock, short-circuit, or fire. * Contact the supplier concerning repair advice if cord or plug are damaged. Avoid use of electrical socket or extension cables outside their rated range, and do not use with a power source other than 230V AC (+/- 10V). * Use outside the rated range can cause heat generation, resulting in a fire. Insert the power plug firmly into the socket until it is securely fitted. * Insecure insertion of the plug may cause electrical shock, or a fire through heat generation. Do not use a damaged plug or loose sockets. Clean off dust from the power cord periodically Dust accumulated on the plug can cause an insulation failure, resulting in a fire.. Pull out the plug and wipe it with a dry cloth.. Remove the plug from the socket when the unit is not in use. Do not switch the unit ON/OFF at the power socket This can cause an electrical shock or a fire through heat generation. 29

Warning Do not put any foreign objects such as pins, wires, or metallic items into the air outlet, or vents in the unit. Such objects may touch electrical parts inside and cause an electrical shock or injury. Do not insert /remove the power plug with wet hands. Wet hands prohibited. This can cause an electrical shock. If anything unusual occurs (such as smell of burning) switch off and unplug the power cord. Heat generation can cause a fire or an electrical shock. * Contact the supplier. Do not insert fingers or long thin objects into the air inlet/outlet, or vents in the unit. Warning: Rotating parts. Heat generation can cause a fire or an electrical shock. * Such objects may touch the fan inside, and cause an injury or electrical shock. Do not place the unit near heating appliances. Inflammables Plastic parts can melt and catch fire. Do not take apart, repair or modify. Taking apart the unit is prohibited Dismantling the unit may cause a fire or electrical shock * Contact the supplier for all repairs. Switch off and unplug the power plug during routine maintenance, in order to avoid the unit switching on unintentionally, and causing an injury or electrical shock. 30

Caution Grip the plug, not the cord, when removing the power plug from the socket, to avoid damage to the cord, or short-circuits, which may cause a fire or electrical shock. Place the unit on a level and stable surface. If the unit falls over, and water is spilled, it may wet household goods, and may cause a fire or electrical shock. * If the unit falls over, stand it up immediately. Do not use the unit in a very small area, such as a cupboard. Poor ventilation can cause overheating or fire. Do not use the unit near water supplies. Exposure to water prohibited This may cause a fire or electrical shock. Do not use the unit where oil or inflammable gas may leak. Gas leak, and vapour around the unit, can cause fire. Do not use the unit in direct sunlight, wind or rain. A fire or electrical shock may be caused by overheating. Do not use the unit for protecting works of arts, old manuscripts or other materials requiring specialist protection. The quality of valuable and sensitive objects may deteriorate. Do not use heaters with open burners in the direct air flow from the air outlet of the unit. This can cause incomplete combustion and could cause carbon monoxide to be given off. Do not use the dehumidified water for drinking, or feeding pets. It may damage health. 31

Do not wash the unit with water. Exposure to water prohibited It can cause electric leakage, resulting in an electrical shock. Do not place containers of water, such as a vase, on the unit. If water enters the unit it can cause poor electrical insulation, which may cause a fire and electrical shock. Do not obstruct the air inlet and outlet of the unit with fabrics or bedding. Bad ventilation can cause overheating or fire. Do not step or sit on the unit. This may result in a fall and injury. Switch off and drain the water tank before moving the dehumidifier. Any spillage will make possessions damp, and may cause a fire or electrical shock. Particular care must be taken in the following circumstances: -When the dehumidifier is used in the presence of infants, children, old people or others who cannot operate the unit by themselves. -Heat generated from the unit when switched on will raise the room temperature. Sitting in the direct air flow from the dehumidifier for extended periods may cause dehydration and discomfort. Do not use the unit where pharmaceuticals/chemicals are handled. (In hospitals, factories, laboratories, beauty salons, etc.) Chemicals and solvents in the atmosphere can damage the dehumidifier, and water may make items damp. 32

Names of parts Humidity setting lights (AUTOMATIC OPERATION) Operation status lights Operation OFF/ON button Humidity setting buttons Warning light Lights up when the appliance is not running properly Full Tank light Lights up when the tank is full, or is not properly installed. Dehumidification switching button (SELECT button / CONSTANT OPERATION Air filter Prevents dust from entering the unit Handle Air outlet Use the Carbon Filter together with Air Filter Lid Remove transit tape. Tank cap. Tank Cap - See p. 40. 33

General precautions Before use When Installing Follow these instructions to ensure your unit operates properly. - Do not place any objects within the distances shown below: - Place the unit at least 1m away from TV, and radio receiver, etc.. (to prevent interference with reception.) Keep a distance of at least 1 m to prevent interference. When switched on ensure: Room temperature is between approximately 1 o C - 40ºC, and that humidity is 20% or more. When room temperature is other than the range indicated, safety devices may operate to switch-off and protect the unit. - As humidity in a room decreases, the rate of dehumidification drops. Do not knock or tilt the unit. If the unit falls over, stand it up immediately. Even after dehumidifcation, condensation, or mould growth may still occur on window panels exposed to outside air, or in unventilated places (such as behind furniture). Caution Do not obstruct the air inlet and outlet of the unit with fabrics etc. - Bad ventilation can cause overheating or fire. If a power cut occurs when the unit is switched on -The dehumidifier will switch off. Turn ON again by pressing the Operation OFF/ON button after the power is restored. 34

How to operate Air outlet Humidity setting buttons 2 Dehumidification switch (SELECT button) 1 Operation OFF/ON button Warning light 3 Full Tank light Start Press 1 (Operation OFF/ON button) The unit will start MID operation. (MID Light turns ON.) Press the button again to switch off. (All lights turn OFF) SELECT button /For CONSTANT operation Press 2 SELECT Every time you press the button, the operation switches sequentially between HI (Lights up)-> MID -> LO. For rapid dehumidification ------------Select HI For quiet operation --------------------Select LO When tank is full or not in place 3 (Flashing) Unit switches off automatically When the tank is emptied and returned to the unit, the unit will restart in the same mode as before. ( Full Tanklight turns OFF) AUTOMATIC Operation with humidity setting Press 4 Press 5 Press 6 40% light ON 50% light ON 60% light ON When using the AUTOMATIC function you select the desired maximum humidity level. The unit will automatically switch between HI and LO in order to achieve this level. Normally it will run on HI if the humidity level is 10% or more higher than the set level. If the humidity level in the room falls below the set level it will revert to a Fan Only mode to conserve energy but will not switch off completely. This indicates the actual humidity is 50% or more with the 40% setting selected. SELECT Note Before unplugging or switching off at the power socket Be sure to wait for approximately 3 minutes after turning OFF the unit before unplugging the power. (A fan continues to run to cool down the heater for approximately 3 minutes after the unit is turned OFF) Operation OFF/ON button and SELECT button click when pressed. This is normal. 35

How to drain water You need to drain water The unit switches off automatically when the water tank is full. (approximately 5.5L) Tank Full light flashes. (All the other lights turn OFF) Tank Full indicator (flashing) When tank is full How to remove tank Pull out the tank slowly. Hold the drawer handle and pull out the tank carefully. How to install the tank 1. Replace the lid Insert the front first. Drawer pull 2. 2. Insert the tank slowly until it stops. Insert slowly and securely until properly in place. 2. Remove the lid and drain water Drawer pull Note Always replace the lid on the tank, or water will leak. Do not touch parts inside the unit when the tank is removed. This may cause failure of the unit. Insert the tank slowly and securely until it is fully in place. The unit may not switch on if the tank is inserted forcibly, or not replaced securely. If necessary, remove the tank, and re-insert with care. 36

Maintenance and care 1. Switch off (Turn OFF by pressing Operation OFF/ON switch) 2. Unplug the power cord Main unit (Monthly) Wipe off dirt with a soft cloth that has been dipped in lukewarm water or mild kitchen detergent, diluted with water, and wrung out. Then wipe the unit dry with a clean cloth. Clean the air inlet and outlet using the suction nozzle of a vacuum cleaner. Note Do not lay the unit down. This can cause water to leak. Do not pour water directly on to the unit. This can cause an insulation failure, rust, and electrical shock. Do not use cleaning agents, as shown above right. Use of these can cause damage to and/or discoloration of the unit. When you intend to use a chemically treated cleaning cloth, first read and then follow the directions. Water Tank, Lid, Float (About every two weeks) Tank and lid Rinse a few times with clean tap water. If the dirt is heavy, wash with mild kitchen detergent diluted with water. Float Remove slime on the float, without detaching it. Also remove dirt around the shafts (this prevents malfunction of the float) Float Shafts Note Always replace lid on the tank, or water may leak. The inside of the tank can turn brownish due to dirt dissolved into dehumidified water, depending on the conditions in the room. Insert the tank slowly and securely until is fully in place. The unit may not switch on unless the tank is replaced securely. Note Never detach the float. (The unit will not run when detached. Improper installation can also cause water to leak.) Do not remove the Styrofoam in the float. If detached, the unit will not switch off even when water reaches Full, and water may leak. (Tank Full detection does not work.) If the float comes off refit the shafts into the appropriate size hole. (See the figure above) 37

Air filter (About every two weeks) A clogged air filter will impair dehumidification, increase electricity costs, and cause problems. If running the unit without fitting the air filter, dust will accumulate inside and may cause problems. Air filter must be; Cleaned with the small nozzle of a vacuum cleaner. If the dirt is thick, wash out the filter with mild kitchen detergent diluted with water, and dry. Tab How to detach Pull out the filter. How to refit Hold the tab of the filter endways and insert it into the slot in the unit Tab slot When not using for a long period 1. Leave the unit for one day after switching off and then drain the water from the tank completely. 2. Clean the main unit, tank, and air filter. 3. Cover the main unit with a plastic bag or other cover. 4. Store in an upright position, in a dry and well-ventilated place. Note Store the unit in an upright position on a level and stable surface. Tilting or laying down the unit can cause problems, or leakage of any water remaining inside. If the unit falls over, stand it up immediately. Specifications Model DH 600 Power source 230V +/- 10V, AC 50Hz Rated dehumidification capacity 5.5L/day at 20 C and 80 % RH / 5.1L/day at 5 C and 60% RH Power consumption 0.435 kw. Working noise level (db) HI MID LO (Quiet mode) 4 5 40 29 Drainage water tank capacity Approx. 5.5L (Automatic stop) Product weight 7.0 Kgs Product Dimensions 545H x 20OW x 430D (mm) Length of power cord 2.O m Accessory Carbon filter Rated dehumidification capacity indicates the amount of dehumidified water extracted per day when the room temperature and relative humidity is maintained at 20 C and 80% respectively. 38

Troubleshooting Before sending for repair Check the following points before sending for repair. Problem Check I Corrective action Does not switch on. Is the power plug properly in the socket? Has the fuse blown? (replace the fuse - 3 amp rating) Is the Tank full light blinking? Has the tank been replaced properly? Is it out of place? Tank Full/No Tank light Flashes, even though the tank is Was the tank forcibly re-fitted? Was it inserted fully to the end? -> Remove the tank and carefully re-fit it. not full. Is the float out of place? Reference Page 35 33,35 33,36 33,36 37 Abnormal, loud sound when on. Is the air filter clogged up? Is the unit standing on a firm and stable base? Is the floor unstable? 38 3 3 Water leakage. Has the unit tilted or fallen over? Has the unit been moved with water in the tank? Is the float detached? 3,32 37 Water is collecting very slowly. (Unusually low dehumidification rate) Is the air filter clogged up? Is the air inlet or outlet obstructed? Is the room temperature /humidity low? ->As the room temperature / humidity drops, the extraction and collection of dehumidified water decreases. 38 32,34 34 ' Humidity does not decrease. Is the room too large? Are the windows/ doors being opened/closed too often? Is there a source of humidity, such as an LPG Heater? 38 28 If the unit has fallen over/ been knocked. Stand the unit up immediately (to minimize the amount of water leakage) -> The Warning light flashes. Unplug the power cord and check the equipment. 3,37 If warning light is ON Unplug the power cord and check the equipment according to the instructions. Indicated symptom Check points Reference Page Warning light on Warning light on and all other lights are flashing Is the air filter clogged up?-> Clean the air filter. Is the air outlet obstructed?->remove obstruction from the outlet. Has the unit fallen over?->. Unplug the power cord 2. Stand the unit up. 3. Wipe off water spilled from the tank and splashed on the unit. 4. Plug in the power cord again. Is the humidity in the room too low?->the lowest room humidity for the unit to operate effectively is approximately 20%. Contact your supplier 38 32 34 34 39

Symptom Yes, it s all right Reference Page Ambient temperature rises during running This product does not have a cooling function, and is designed to generate heat when on. Since windows and doors are normally closed while in use, other heat sources can also create a temperature increase. Thus, the room temperature may rise approximately 3-8 C, or even more. 28 If a problem persists, contact the supplier. DRAINING OF WATER DIRECTLY TO WASTE Your dehumidifier can be set up to drain the waste water via a tube directly into a sink or drain. Procedure: Remove the cap on the back of the unit.(snap off using a blunt, flat blade) Gently pull back the sealing arm exposing the drain pipe. Fit a 2 to 4 mm diameter drainage tube (not supplied) on the outlet pipe. Test the connection to detect and rectify possible leaks. If you want to close the opening, please use the cap supplied. WARNING: The drainage tube should always be fitted so that the water from the unit can flow freely down, by gravity, to waste. DISPOSING OF THIS PRODUCT This Product and its packaging should be disposed of responsibly, check with your Retailer or Local Authority as to appropriate methods of disposal. It does not contain any refrigerant. Please ask your retailer for replacement carbon filter pads once cleaning becomes impractical. 40