MXL/MXLV 19 Rack Mount Equipment

Similar documents
MXL/MXLV Enclosuress & Equipment Models: MME-3, MBR-MP, MLE-6, MBR-3MP, MDL-1, MDB-1, MDG-1, MHD-1, MHD-2, MHD-3, MHD-4

Fire Safety. Installation Instructions Model PSR-1 Remote Power Supply INTRODUCTION. Figure 1 PSR-1 Remote Power Supply

Advanced Protection System

Fire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS

Fire Safety. Installation Instructions Model D2300CPS Fiber Optic Interface INTRODUCTION MOUNTING ELECTRICAL CONNECTIONS. Figure 1 D2300CPS Module

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS

Operating Instructions MXL Multi-Line Keyboard/Display Panel

MXL-IQ CONTROL PANEL. Operation, Installation, and Maintenance Manual. Siemens Industry, Inc. Building Technologies Division Florham Park, NJ

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Air Duct Housings. Description

Installation Manual For The Mxl Panel READ ONLINE

Marine Fire Detection System Manual MXL Control Panel

Fire Safety. Installation Instructions Model NIM-1W Network Interface Module MXL NETWORK INTERFACE APPLICATIONS OPERATION NIM-1W

Siemens Fire Alarm Panel Xls Operation Manual READ ONLINE

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

FireFinder XLSV Digital Emergency Voice Alarm / Communication System

NETWORK FIRE ALARM CONTROL PANEL. Features

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

INSTALLATION INSTRUCTIONS TALKBACK MODULE

Innovative protection that combines power and flexibility

Cerberus PRO A comprehensive fire-protection system

E3 Series Broadband System

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

SI120 Guarto Easy I. Alarm system. Fire & Security Products

Bosch EVAX System - High-rise Applications

E3 Series Broadband System

Desigo TM Fire Safety System A comprehensive fire-protection system

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fire control panels FC726 FC726-XA

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

FIREFINDER-XLS CONTROL PANEL

SECURE LIFE SAFETY PAGA

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

Public Address Project Combisound System

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

INTELLIGENT FIRE ALARM CONTROL PANEL

Emergency Communications Tower Applications (Solar/Wireless/Surveillance)

EQUIPMENT SPECIFICATION. GAI-TRONICS ADDRESSABLE AMPLIFIED SPEAKER and AUDIO MESSENGER INTERFACE PRODUCTS

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Electrical Inspection Special Electrical

SP40S-D. Kingfisher Company, inc. Features: Description:

The Omni IIe Controller

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

Figure 1. Figure 2. See notes 1 and 2 below.

OmniPro II. Technical Sheet. DESCRIPTION

SAFEPATH Mass Notification System (SPMNS)

FIREFINDER-XLS CONTROL PANEL

CATALOG NUMBER. Features. Description

Inside a typical. Intelligent Voice Communication System. Mounting Diagram. 2 Cerberus PRO. 252 / 504-point Cerberus PRO fire / voice system

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Fire control panels FC360

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Versatile. VM Mid-range Life Safety Solutions. S e e. w h a t ' s p o s s i b l e n o w..

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

Project Name. Date. Cat. Number. Type

Network Display Unit Installation Instructions

NAME OF WORK - IIM AHMEDABAD - LIBRARY BOQ OF ELV WORKS Item #

Project 4: Active Fire Protection Systems Issues. Project 4: Investigation Team

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

Modular Fire Panel 5000 Series Just as flexible as your plans

[DOC] SIEMENS MXL FIRE ALARM PANEL OPERATION MANUAL

ARCHITECT AND ENGINEER SPECIFICATIONS

Cerberus PRO Modular system

Autonomous control unit

Desigo TM Fire Safety System A comprehensive fire-protection system

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

ONYX FirstVision Specification Interactive Firefighters Display

The Standard In Safety

Contents AS100/150/200 TACK SEALER V FOLD. Operating Instructions

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Long Range Radio Alarm Transmitter

FC724 Fire control panel

Call stations and extensions

FC722 Fire control panel

DS7400Xi Addressable Control/ Communicator

SAFEPATH SAFEPATH. Emergency communications system

STATEMENT OF WORK. System Description:

WIRELESS CONTROLS & DETECTORS

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

I NSTALLATION M ANUAL

SOUTH AFRICAN NATIONAL STANDARD

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

CX/CXB Self-Managed Ethernet Switches N-664 Network Appliance Data and Alarm I/O Device MX Series Multi-Port Switches

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

Change History Log. Rev Revision Sections Affected Description of Change /22/08 All Initial Version

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

Spectronics Fire Alarm System Manual READ ONLINE

Essentials Series 4.0

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

Transcription:

MXL/MXLV 19 Rack Mount Equipment Models: MXL-RK1, ACM-RK, MKB-RK, MMB-RK, MOM-RK, MPS-RK, TSP-RK, VSM-RK, CABLES-RK, MKB-3 ENGINEER AND ARCHITECT SPECIFICATIONS Standard 19 Rack Mounting for MXL and MXLV System Modules Rack Mount Sheet Metal Adapter Brackets Use Standard MXL/MXLV Modules 19 Rack Enclosure Shipped Complete NO Assembly Required Listed Description The RK Series of adapter plates provide the option of standard 19 rack mounting of MXL and MXLV system modules. The MXL-RK1 is a 70 inch high standard 19 wide x 18 deep rack package supplied complete with UL 864 listing directly from Cerberus Pyrotronics. The MXL-RK1 is supplied assembled with all side, back and top panels. The front door comes with a lock assembly using the same key as other Cerberus Pyrotronics enclosures. The door comes with a clear, fire rated plexiglass lens installed. MXL-RK1 also comes with a battery tray and all necessary mounting hardware. This equipment is approved for operation over the temperature range of 0 C to 49 C. All MXL modules require one or more of the following 19 rack mount adapter plates to mount inside the MXL-RK1. MXL and MXLV modules must be ordered seperately, the following are mounting plates: ACM-RK Voice Module Mounting Plate The ACM-RK mounting is 17½ high by 19 wide and has mounting space available for (1) ACM-1 Audio Control Module, (1) MMM-1 Master Microphone Module, (1) TMM-1 Telephone Master Module, (1) TBM-2 Terminal Block Module, and (1) PIM-1 Peripheral Interface Module. CATALOG NUMBER ACM-RK 5057

MKB-RK MXL/V Display and Control Keypad Mounting Plate The MKB-RK Mounting Plate is high by 19 wide and has space available for (1) MKB-3 MXL Display and Control Keypad Module and (1) PIM-1 Peripheral Interface Module. MMB-RK MKB-RK MKB-3 MXL/V 19 Rack Mount Display and Control Keypad The MKB-3 is a fully functional MXL/V system display and control keypad module. The MKB-RK is required to mount the MKB-3 in the MXL-RK1 standard 19 wide rack mount enclosure. Only the MKB-3 is designed for use in the MXL- RK1 enclosure. MKB-3 should be ordered in place of other MXL/V model displays (MKB-1, MKB-2, MKB-4) for 19 rack mount use. The MKB-3 is configured via the MXL/V custom software generator program - AccuLINK and is addressed via a dipswitch on the MKB-3 s ANN-1 circuit board. MOM-RK MXL Expansion Module Cardcage Mounting Plate The MOM-RK mounting plate is 17½ high by 19 wide and has mounting space available for up to 3 MXL/V Expansion cardcages (MOM-4, MOM-2, OMM-1 or OMM-2) in any combination. The MXL-MPFO mounting plate may also be mounted on the MOM-RK to allow mounting of D2300CP Fiber Optic Interface Modules or CCU/M Pager Interface Modules. By using the MOM-RK with the appropriate cardcage the following MXL/V modules may be mounting in the MXL-RK1 rack: MOM-4 / MOM-2 ALD-2I CSM-4 CZM-4 CMI-300 CRM-4 NET-7/7M NIM-1R REP-1 XLD-1 OMM-1 / OMM-2 OCC-1 / BTC-1 ASC-1 ASC-2 PLC-4/PL864-25A/PL864-25S/PL864-70A RCM-1 ZC1-8B ZC2-8B ZC2-4AB ZC3-4AB ZCT-8B ZAC-30 MKB-3 MMB-RK MMB and PSR Mounting Plate The MMB-RK mounting plate is high by 19 wide and allows mounting for either (1) MMB MXL Main Mother Board or (1) PSR Remote Power Supply Module. MOM-RK MPS-RK MXL/V Power Supply Mounting Plate The MPS-RK mounting plate is 8¾ high by 19 wide and allows mounting for up to (2) MPS-6 or MPS-12 Power Supplies.

CABLES-RK 19 Rack Mount Extended Interconnect Cables The CABLE-RK kit contains (4) extended length MXL and MXLV interconnection cables. It contains: (1) ACM to TMM-1 24 Cable (1) ACM to ANN-1 24 Cable (1) MMB to Battery 60 Cable (1) MMM-1 to ACM-1 6 Cable Ordering Information MPS-RK TSP-RK Internal Strip Printer Mounting Plate The TSP-RK is a 12½ high by 19 wide mounting plate set for mounting (1) TSP-40 Internal Thermal Strip Printer in the MXL-RK1 19 rack mount enclosure. The TSP-RK comes with a U-shaped plate with mounting studs for the TSP-40 printer. It is also supplied with a dress plate and clear lens. Model Description Part Number MXL-RK1 70 Inch High Vertical 19 Rack 500-69347 ACM-RK Voice Module Mounting Plate 500-89304 MKB-RK MKB-3 MXL Display Mounting Plate (for MKB-3) MXL 19 Rack Mount Display/Control Keypad 500-89304 500-89350 MMB-RK MMB/PSR Mounting Plate 500-89304 MOM-RK MOM/OMM Mounting Plate 500-89305 MPS-RK MPS-6/MPS-12 Mounting PLate 500-89304 TSP-RK TSP-40 Mounting Plate 500-89304 VSM-RK VSM/VLM/VFM/VSB Mounting Plate 500-89304 CABLES-RK Rack Mount Expansion Cables 500-89304 Installation Instructions 315-09340 TSP-RK VSM-RK MXL/V VSM-1/VLM-1/VFM-1/VSB-1 Mounting Plate The VSM-RK mounting plate is 7 high by 19 wide and provides mounting space for any combination of up to (6) VSM-1 Voice Switch/LED Module, VLM-1 Voice LED Module, VFM-1 Fan Control Module or VSB-1 Blank Plates. VSM-RK

Mounting Diagram 12 17½ 17½ 7 70 7 9 MXLV (with Voice) Mounted on 19 Rack

12 17½ 70 9 MXL (without Voice) Mounted on 19 Rack

NOTICE: The use of other than Cerberus Pyrotronics detectors and bases with Cerberus Pyrotronics control equipment will be considered a misapplication of Cerberus Pyrotronics equipment and as such void all warranties either expressed or implied with regards to loss, damage, liabilities and/or service problems. Cerberus Pyrotronics 8 Ridgedale Avenue Cedar Knolls, NJ 07927 Tel: (201) 267-1300 FAX: (201) 397-7008 Website: www.cerbpyro.com 4/97 10M CPY-IG Printed in U.S.A. Cerberus Pyrotronics 50 East Pearce Street Richmond Hill, Ontario L4B, 1B7 CN Tel: (905) 764-8384 FAX: (905) 731-9182 April 1997 Supersedes sheet dated 12/96