Weighing whole with Dini Argeo indicator + Dini Argeo JBxxx Atex junction box + zener barriers + Dini Argeo Atex load receptor (s/n )

Similar documents
Declaration of conformity

DB5 Intrinsically Safe Sounder Type DB-5

Fixed Gas Detection System/Meridian CERTIFICATION

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

IECEx Certificate of Conformity

IECEx Certificate of Conformity

ATEX, NOMENCLATURE AND CODING

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

IECEx Certificate of Conformity

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

Certificate of Compliance

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

SET-2000 Oil/Sludge 12 VDC

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

Manual Isolating Barrier D461R1 (Revision 01)

Operating Instructions Edition 02/2007

4) Intrinsic Safety Certification

ATEX, NOMENCLATURE AND CODING

Product Information to the manual

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Installation and Operating Instruction

INSTRUCTION MANUAL (ATEX)

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

TRASCO ATEX Couplings

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Installationsmanual GWSL1100/2100, GWML3100

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

ANNEX GD-CERT-EX-EN SIT

Manual Isolating Barrier D461 (Revision 05)

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

official distributor of Newson Gale Ltd.

Certificate of Compliance

Annubar Flowmeter Series

Exp, pressurized systems

FDOOT241-A9-Ex Multisensor fire detector

EU DECLARATION OF CONFORMITY

IECEx Certificate of Conformity

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Technical Data. Dimensions

SET-2000 Hi Level/Oil

14300 MAINS SEPARATOR ALARM MANUAL

Instruction manual 640 Securiterre

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

SET Installation and Operating Instructions. Level switch for one sensor

Manual Power relay SR853

Rosemount 702 Wireless Discrete Transmitter

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.

ATM Lighting sp. z o.o

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

IECEx Certificate of Conformity

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

METALDRIVE ATEX Couplings

PROTECT SRB 200EXi-1A

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Universal Tank Alarm Type Installation, Operation & Maintenance

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.

FDCL221-Ex Line adapter (Ex)

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

User s Manual YTA610 and YTA710 NEPSI Certification

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

ATM Lighting sp. z o.o

Tank Gauging System Special Safety Instruction

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

IECEx Certificate of Conformity

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

国家级仪器仪表防爆安全监督检验站 National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation (GYJ ) (Attachment Ⅰ) Attachm

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

AND INSTALLATION MANUAL

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

OOH740-A9-Ex Multi-sensor fire detector

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

OOH740-A9-Ex Multisensor fire detector

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS

OPTIBAR P 1010/2010 C Supplementary instructions

Transcription:

Weighing whole with Dini Argeo indicator + Dini Argeo JBxxx Atex junction box + zener barriers + Dini Argeo Atex load receptor (s/n 123456) Description of the system The system is made up of the following parts: 1. a Dini Argeo weight indicator; 2. a kit of three ATEX certified zener barriers; 3. an ATEX certified JBxxx junction box; 4. a Dini Argeo Atex load receptor and relative accessories; 5. one or more ATEX certified Dini Argeo load cells. This document is made in order to verify the connection of these parts, without considering further risks, in accordance with the EN 60079-25:2004 / IEC 60079-25:2003 norm. Composition 1) A Dini Argeo weight indicator which belongs to one of these series: TRI, DFW, DGT, 3590, CPW, TRS, and which must be positioned in a safe zone. 2) A PEPPERL+FUCHS Z996.H zener barrier for the excitation cable of the load cells; and two PEPPERL+FUCHS Z961.H zener barriers for the reference and the load cell signal cables; Dini Argeo MB4 code of the whole system of these three zener barriers. ATEX certificate: BAS01ATEX7005 - Issue 7 II (1) GD [Ex ia] IIC (-20 C Ta +60 C) [Ex iad] Ex data: Z966.H Z961.H Uo= 24 V Uo= 17,4 V Io= 164 ma Io= 25 ma Po= 0,98 W Po= 0,05 W Co= 0,125 µf Co= 0,346 µf Lo= 0,33 mh Lo= 14,8 mh 3) Atex SRL JBxxx junction box. ATEX certificate: CEC 08 ATEX 019 1131 II 2G Ex ib IIC T6 1131 II 2D Ex td A21 IP65 T115 C Ex data: Uo=Ui= 24V Io=Ii= 174mA Co=Ci=0mF Lo=Li=0mH or: Uo=Ui= 12V Io=Ii= 3,33A Co=Ci=0mF Lo=Li=0mH 4) Dini Argeo Atex load received and relative accessories: - Electronic weighing platforms: T, RPLC, ET, EL, LP, PW, BP - Accessories: CSP, TSNC, TTNC, TQNC, TMNC, TLNC, ETATF, ETMTF, ETBTF, ETDTF, ETETF, ETFTF, ETHTF, ETLTF, ETAR, ETBR, ETDR, ETER, LPER, LPFR, ETPFI, ETPFIM20 Via della Fisica, 20-41042 Spezzano di Fiorano (MO) -

- Carts: TB, TA - Raising frames: SGAQ, SGAX - Load cell assembly kit: KSPOT, KSPOC, KSB, KDSBN, KCPN, KRCK, KST AETF01 technical file Dep.n CEC-04/2036-ADF088 II 2 GD c IIC T6 85 C 5) SRL Atex load cells which belongs to one of these series: SOT SPSE - IBM3 - BM3 - SBX - STD - HM9B - IBM2 - BM2 - SPSC CS CSI CF - CFI STFC - SBCW SBK -SBC CFLI - CP SPSB - IBM1 - BM1 FXC -STG IBM - BM - SBK- 1KL - SBK-1K SBK5000-1KL -CSG CSGI - CCI RCK - CBC CBCI - DSBI - STFU SPGS - SBH SBCS - RSB - SBU SPO SPBC SPH SPG - CB17 - TH1042 - L6E - CZL6 - L6G - L6F - PW12C - SBZ. ATEX certificate: CEC 07 ATEX 093 X rev1 - II 1G EExia IIC T6 (Ta -20 +40 C) TX (Ta -20 +65 C) - II 1D td A20 TX C (Ta -20 +40 C) TX C (Ta -20 +65 C) Ex data: - Ui= 24V, Ii= 174mA, Ci= trascurabile/negligible, Li= trascurabile/negligible - Ui= 12V, Ii= 3,33A, Ci= trascurabile/negligible, Li= trascurabile/negligible Cable features between the zener barriers connection to the JBxxx Atex junction box: LY02506 manufacturer code (6x0,25mmq), Dini Argeo code LCCB Conforms to the following norms: CEI 20-22 III cat. C; CEI 20-29, IEC 60228, CEI 20-11, CEI 20-35, IEC 60332.1, CEI 20-22 II, IEC 60332.C, CEI 20-37, IEC 60754, CEI 20-52 R max a 20 C = 75q/Km Cc= 115 pf/m Cs= 258,3 pf/m Lc= 1,33 mh/km Cond./cond. test voltage= 2000 V x 5 minutes Cond./shield test voltage= 2000 V x 1 minute Rated voltage= 300/500 V Operating temperature= -10/+70 C The verification of the Ex parameters of the whole has been executed, taking into consideration a maximum length of the cable between the zener barriers connection to the JBxxx Atex junction box of 50 m. Via della Fisica, 20-41042 Spezzano di Fiorano (MO) -

Electrical connection CAREFUL The barriers and the weight indicator must be installed outside of the hazardous area! The safety requirements are respected only with a grounding of the zener barriers, Atex load cells, JBxxx Atex junction box, load cell shieldings, Atex load receptor, and of all the other parts of the whole Atex system (indicator holder column, etc.). See the supplied instructions manual of all the parts which make up the whole atex system. Conclusions This whole of components does not produce and added risk. The whole Atex system resulting from this union can be used in a hazardous area, with the sole limitation of each single element and the Atex marking of the whole system (see Atex declaration of the whole system at the end of this document). Via della Fisica, 20-41042 Spezzano di Fiorano (MO) -

WARNINGS The use of the whole in hazardous areas requires a particular attention and precautionary measures both during use and maintenance. Do not install and use the various components in environments different than those provided for. The installation, maintenance, and repair of the components must be executed by competent and authorised personnel. The safety of the explosion-proof whole is guaranteed only if the system is installed, used, and taken care of following the instructions in this manual and in the relative manuals of the single components. Avoid accumulations of electrostatic charges; therefore, in order to operate in a hazardous area, the operator or maintenance person must wear adequate work clothing. Do not cover the single components with coverings made of materials which could be electro statically charged. It is forbidden to modify or repair the Ex components with components which are non conforming to the relative certifications; this action could compromise the safety of these (with subsequent loss of the Ex approval) and the voiding of the product warranty. It is forbidden to connect modules not listed in this document; this action could compromise the safety of the whole (with subsequent loss of the Ex approval). Contact Dini Argeo srl for further details. Be very careful during the use: eventual sparks could cause an explosion. Read the documents of all the devices which make up the whole system (zener barriers, junction boxes, load cells, etc.) and carefully follow the various instructions. INSTRUCTIONS FOR INSTALLING IN A HAZARDOUS AREA This Atex whole must be installed and maintained, according to the applicable norms relative to the installations in a hazardous zone (different from the mines) classified for the presence of gas as ZONE 1, and/or the presence of dusts like ZONE 21, for example: EN 60079-14:2008 / IEC 60079-14:2007, EN 60079-17:2007 / IEC 60079-17:2007, EN 1127-1:2007 and all the norms applicable in the zone and in the installation environment. Ground the zener barriers, the weight indicator, the Atex load cells, the Atex JBxx junction box, the cable shieldings, the Atex load receiver, and of all the other parts of the whole atex system (indicator holder column, etc.). WE DECLINE ALL RESPONSIBILITY FOR DAMAGES CAUSED BY THE UNOBSERVANCE OF THESE WARNINGS Via della Fisica, 20-41042 Spezzano di Fiorano (MO) -

CE DECLARATION OF CONFORMITY We Srl, Via della Fisica, 20 41042 Spezzano di Fiorano - MODENA - ITALY We declare under our responsibility that the whole described in this document conforms to the following directives: - ATEX 94/9/EC The conformity is showing by observing the following norms: - EN 60079-0:2006 - EN 60079-11:2007 - EN 60079-25:2004 / IEC 60079-25:2003 - EN 61241-0:2007 - EN 61241-1:2006 - EN 61241-11:2006 - EN 1127-1:2007 - EN 13463-1:2009 - EN 13463-5:2003 Markings: - II 2GD IIC T6 T125 C (Ta -20 +40 C) X Spezzano di Fiorano, 12/01/2012 Signature Marco Bertoni President Via della Fisica, 20-41042 Spezzano di Fiorano (MO) -