ABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)

Similar documents
ABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)

ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.

Symphony Plus Combustion instruments

COMPACT FLAME CONTROLLER CFC 1000

COMPACT FLAME CONTROLLER CFC 2000

COMPACT FLAME CONTROLLER CFC 100

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

W-FLAME IR/UV FLAME DETECTOR

Flame Monitors BROCHURE

DSF-2010-SB KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!

DSF-2010-SB KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!

S55XB and S55XBE Series Viewing Heads

Eclipse 90 UV Scanner Model A Version 1

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Chemical Processes in the Combustion

Standard Applications Guide

Fireye Flame Safeguard Controls

Standard Applications Guide

55UV5 SCANNER MODEL 1010

FIREYE C9707A ALL FUEL SCANNER

S55XB and S55XBE Series Viewing Heads

Eclipse Self-Check UV Scanner

Products Catalog. Flame Monitoring & Evaluation Systems

Dräger Flame 2100 Flame Detection

U2 Combination Viewing Head and Signal Processors

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

MBCE-110/230UV Flame Sensor Module

Flame Detection Jon Sarfas

EZ-FLAME Detector USER MANUAL

Fireye FLAME SCANNERS

Products Catalog. Flame Monitoring & Evaluation Systems

Distributed By: M&M Control Service, INC

DESCRIPTION AND INSTALLATION

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Dräger Flame 2500 Flame Detection

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

TYPE 105F1-1 Integrated Flame Scanner and Temperature Analyzer

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

Distributed By: M&M Control Service, INC

Product Overview Combustion Technology

FIREYE FLAME SCANNERS

Industrial Flame Monitoring. Engineered For The Toughest Environments

Talentum - Why use our Flame Detectors?

TYPE 95IR/95UV/95DS. Integrated Flame Scanner with Internal Flame Relay TUV SIL2 DESCRIPTION MODEL S1, S2. RoHS Compliant to EU Directive 2002/95/EC

UV - flame detector dual fuel burners for intermittent burner operations

Conspec - Why use our Flame Detectors

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

INDUSTRIAL FLAME SCANNERS

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

Dräger Flame 2350 (UV&IR) Flame Detection

FIREYE FLAME SCANNERS

MBCE-110/230FR Flame Sensor Module

Dräger Flame 2370 (UV&IR) Flame Detection

Product Overview Combustion Technology

Lamp Supply (Recommended)

TYPE 85UVF/IRF Integrated Flame Scanner with Internal Flame Relay

The SharpEye 40/40I (IR3) Flame Detection

Industrial Flame Monitoring

NMC Nozzle Mix Gas/Oil Combination Burners

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Dräger Flame 2100 (UV) Flame Detection

FIREYE FLAME SCANNERS

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Dräger Flame 2500 (IR3) Flame Detection

DESCRIPTION AND INSTALLATION

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

IFD-E Flame Detector User Manual

The SharpEye 40/40M (Multi IR) Flame Detection

Technical Data. Dimensions

talentum Flame detection across the spectrum Range Brochure

Dräger Flame 2700 (Multi-IR) Flame Detection

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

FIREYE FLAME SCANNERS

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

The SharpEye 40/40R (IR) Flame Detection

DESCRIPTION AND INSTALLATION

UV Flame Supervision System

PUV, PIR and PFO Series BROCHURE

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

Gas Turbine Flame Monitoring

Technical Data. Dimensions

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Dräger PIR 3000 Detection of flammable gases and vapours

Talentum Flame Detector User Guide

IFD-E Flame Detector User Manual

Flame Detector User Manual

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

Certification Supplement Manual

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFL Series Burner Flame Safeguard Control

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

FLAME AMPLIFIER MODULE 3001

Dräger PIR 7200 Toxic Gas Detection Transmitter

Transcription:

Flame scanner for gas and oil burners (Rev. B) Application: - Wall fired boilers - Gas and oil burners High sensitive UV tube Continuous self-checking Rugged detector head for harsh environments: - Protection IP66 (NEMA 4X) - Hazardous area EEx-d IICT6 ATEX certified The UR450 is a self checked detector specifically designed to detect individual burner or pilot flames from gaseous and oil fuels The UR450 provides a pulse rates signals proportional to the flame strength, significant of the intensity of the UV radiation detected in the primary combustion zone. The unique algorithm developed in the Uvisor MFD control unit analyzes the flame signal carried from the scanner head, providing reliable detection of the target flame and excellent discrimination against the background and the adjacent burners flame. The UR450 flame scanner is available with aiming accessories and provision for purging air. ABB

TECHNICAL DATA Sensors Spectrum sensitivity Power consumption High sensitive UV tube 190 280 nm 800 mw DC supplied by Uvisor MFD control units Ambient temperature Operating: -10 100 C (14 212 F) T6 classified area: Storage: Max. 60 C (140 F) -40 100 C (-40 212 F) Enclosure IP66 (NEMA 4X) Classification Dimensions Weight Air for lens cleaning Air flow for lens cleaning EEx-d IIC T6, ATEX category G-D CE type examination Certificate CESI 03 ATEX 151 165 x 126 x 126 mm 2.5 kg From clean ambient 115 l/min. (4 SCFM). Excessive contaminant fuels might require up to 400 l/min. (14 SCFM). Minimum cleaning air pressure Mounting connection Cable entry for electrical connection Electrical connections Compatible amplifier unit 20 mm H2O (1" W.C.) above the max wind box pressure measured at the "y" connection inlet. Flanged 3/4" NPT female thread Standard 4 x 0.55 sq.mm (20 AWG) shielded cable. Recommended max. 300 meters (1000 feet) length. Screw type termination. Uvisor MFD series amplifier Approvals CE ATEX FM: FMRC 7610 CSA: CAN/CSA-C22.2 No 199 CAN/CSA E60730-1 (for software) Page 2 of 7

Uvisor UR450 Mod. 5002 UV. Direct view assemblies UR450 Model 5002 UV DETECTOR HEAD Figure A UR450 Model 5002 UV with provision for purging air Figure B UR450 Model 5002 UV with provision for purging air and swivel flange Figure C UR450 Model 5002 UV with provision for purging air, swivel flange and air plug Figure D Uvisor UR450 Mod. 5002. Accessory Flexible air hose Picture 1 Page 3 of 7

Uvisor UR450 Mod. 5002 UV. Dimensional Diagram UR450 Model 5002 UV DETECTOR HEAD Swivel flange and purging air provision Purging air flexible hose Armored hose type 2TE DIN 2021 EN854 ND-19 Temperature 30 to 80 C (-22 to 176 F) Page 4 of 7

Uvisor UR450 Mod. 5002 UV. Electrical Connections 4 conductor cable 20 AWG 4 conductor cable 20 AWG Uvisor MFD connection with two Uvisor scanners type UR450 Mod. 5002 UV Page 5 of 7

FLAME SCANNERS APPLICATION TABLE Fuel Gas (Hydrogen, Propane, NG) Oil (Heavy Oil - steam atom) Low NOx Pulverized Coal Scanners W.F T.F W.F T.F W.F T.F D.S Gas/Lfo Pilot Gas Turbi ne Notes UR600 IR UR600 IR w. FO UR450 UR600 UV UR600 UV-EXT w. FO UR460 UVIR DV (1) Stable signal and excellent target Conventional Lfo pilots and F.O. starting burner can also be supported. Whenever separate scanners for main burner and pilot are required, ABB recommend to approach it with Two-System-in One (2) flame discrimination in corner fired tilting burner installations. ABB recommend to approach opposite burner pair flame scanner equipment with Two- System-in One (2) Stable signal and excellent target Conventional Lfo/gas pilots can also be supported. Whenever separate scanners for main burner and pilot are required, ABB recommend to approach it with Two-System-in One (2) Conventional Lfo pilots and F.O. starting burner can also be supported. Whenever separate scanners for main burner and pilot are required, ABB recommend to approach it with Two-System-in One (2) flame discrimination in corner fired tilting burner installations. ABB recommend to approach opposite burner pair flame scanner equipment with Two- System-in One (2) Stable signal and excellent target UR460 UVIR ER/EF w. FO (1) flame discrimination in corner fired tilting burner installations. Abbreviation and symbols: W.F Wall fired boilers T.F Tangential fired boilers D.S Down Shot boilers w.fo With fiber optic extension 1 2 Only when Specifications call for DUAL SENSOR Uvisor MFD takes advantage of the individual channel Maintenance power-off utility to control two (2) scanner head independently. Individual channel flame relay and flame signal strength analogue output are provided for the Burner Management System and visualization. Acceptable performance Good performance Excellent performance Page 6 of 7

Printed in Italy ORDERING DATA Purchase order must specify the full model number for each component of the system. PRODUCT NAME PART NUMBER ORDERING CODE DESCRIPTION Measure IT Uvisor UR450 Mod. 5002 UV EC-BOM-G009HLA002 84531-S-3250003 Detector head. (Figure A) 84531-S-3250004 Detector head including: Provision for purging air. (Figure B) DIRECT VIEW ASSEMBLIES 84531-S-3250005 Detector head including: Provision for purging air Swivel flange. (Figure C) 84531-S-3250006 Detector head including: Provision for purging air Swivel flange Isolation valve (Figure D) DIRECT VIEW OPTION 84410-S-0400000 Air hose ¾ (Picture 1) ABB For additional information contact: ABB Energy Automation, SpA Via Hermada 6 16154 Genova ITALY uvisor@it.abb.com The Industrial IT word mark and all above-mentioned product names in the form XXXXXXIT are registered or pending trademarks of ABB EC-DOC-G009DS002-B Page 7 of 7