Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Similar documents
Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Rosemount 752 Remote Indicator

Rosemount 4600 Oil & Gas Panel Pressure Transmitter. Quick Start Guide , Rev GA September 2017

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 705 Wireless Totalizing Transmitter

Rosemount 3144P Temperature Transmitter

Rosemount 3144P Temperature Transmitter

Quick Start Guide , Rev HA January Rosemount 248 Temperature Transmitter

Rosemount 2051G Pressure Transmitter

Rosemount 3051HT Hygienic Pressure Transmitter

Rosemount 4088B MultiVariable Transmitter with Bristol Standard Asynchronous/Synchronous Protocol (BSAP)/MVS Protocol

Rosemount 4600 Oil & Gas Panel Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Rosemount 2090F Hygienic Pressure Transmitter

Quick Start Guide , Rev CB May Rosemount 3144P Temperature Transmitters with FOUNDATION fieldbus Protocol

Rosemount 2088, 2090F, and 2090P Pressure Transmitter

Emerson Wireless SmartPower Solutions

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Rosemount 644H Temperature Transmitters

Rosemount 644 Temperature Transmitter

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Rosemount 3144P Temperature Transmitters with FOUNDATION Fieldbus Protocol. Quick Start Guide , Rev DA June 2016

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Rosemount 644H Temperature Transmitters

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series MultiVariable Flowmeter

Rosemount 248 Temperature Transmitter

Rosemount 248 Temperature Transmitter

Quick Start Guide , Rev DA June Rosemount 644H (Device Revision 7 or Previous) and 644R Smart Temperature Transmitters

Rosemount 702 Wireless Discrete Transmitter

Rosemount 2051 Pressure Transmitter and Rosemount 2051CF Series Flowmeter

Rosemount 3051 Pressure Transmitter and Rosemount 3051CF Series Flowmeter

Annubar Flowmeter Series

Rosemount 644H Temperature Transmitters

Rosemount 848T FOUNDATION Fieldbus High Density Temperature Transmitter

Rosemount 3051P In-Line Pressure Transmitter. Product Data Sheet August , Rev BA

Rosemount Wireless Pressure Gauge

Rosemount 248 Temperature Transmitter

Net Safety ST3 XChem Toxic Gas Sensor

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

Rosemount 2140 and 2140:SIS Level Detectors

Rosemount 2088, 2090F, and 2090P Pressure Transmitter

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Rosemount 2130 Level Switch

Rosemount 3051S MultiVariable Extension Supplement

Rosemount 3490 Series

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Model 144H. Product Data Sheet , Rev DB February Content

Rosemount 2088 Absolute and Gage Pressure Transmitter

Rosemount 752 Fieldbus Remote Indicator

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Emerson Plantweb Insight

Rosemount 3051 Pressure Transmitter

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

Rosemount 2100 Series

Rosemount 3051S MultiVariable Transmitter Rosemount 3051SF Series Flowmeter MultiVariable Transmitter

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

Rosemount 848T High Density Temperature Measurement Family

Rosemount 644H and 644R Smart Temperature Transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters

UL HAZARDOUS LOCATIONS SERVICES

Certification Supplement Manual

Rosemount 2088 Absolute and Gage Pressure Transmitter

Certification Supplement Manual

Rosemount 4500 Hygienic Pressure Transmitter. Start

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

STEAM TRAP HEALTH MONITORING SERVICE EXECUTIVE SUMMARY

Rosemount 3051CFP Integral Orifice Flowmeter

Rosemount 4500 Hygienic Pressure Transmitter

Indoor/outdoor resistance thermometer Model TR60

Guide to Hazardous Location Approvals:

Rosemount 2090F Hygienic Pressure Transmitter

805QS Pressure Switch-Transmitter

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Incus Ultrasonic Gas Leak Detector Wide Area Coverage for Pressurized Gas Leaks

Sensor Wiring Instructions and Approval Drawings

Rosemount 2110 Level Switch

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Rosemount High Density Temperature Measurement. Simplify Your Project

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Dräger Polytron 5720 IR Toxic Gas Detection

Certificate of Compliance

Rosemount 3051 Pressure Transmitter Includes Transmitter Option TR ProductDiscontinued. Start

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

CERTIFICATE OF COMPLIANCE

Dräger Polytron 5720 IR Detection of carbon dioxide

Rosemount 3144P Temperature Transmitter

Transcription:

Quick Start Guide 00825-0200-2654, Rev EA Rosemount 0065/0185 Sensor Assembly

Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0065 and 0185 Sensor models. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, Explosion-proof, Flameproof, or intrinsically safe (I.S.) installations. If the Rosemount 0065 or 0185 Sensor was ordered assembled to a temperature transmitter, see the appropriate Quick Start Guide for information on configuration and hazardous locations certifications. WARNING Explosions could result in death or serious injury. Installation of this transmitter in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices. Conduit/cable entries Unless marked, the conduit/cable entries in the transmitter housing use a 1 /2 14 NPT thread form. Entries marked M20 are M20 x 1.5 thread form. On devices with multiple conduit entries, all entries will have the same thread form. Only use plugs, adapters, glands, or conduit with a compatible thread form when closing these entries. Contents Wiring diagrams.......................... 3 Sensor assembly dimensions............... 5 Product certifications..................... 8 2

Quick Start Guide 1.0 Wiring diagrams Figure 1. Rosemount Series 65 RTD Lead Wire Configuration Flying leads and spring-loaded adapter (termination codes 0, 1, or 3 only) Single element Dual element White White Red Red Black Red Red Blue Blue Green Terminal block (termination code 2 and 4) Single element Dual element Red Red 4 3 3 Red 2 Red White 1 1 3 1 White 1 2 3 White 6 6 4 6 Red 6 5 4 5 Red 4 White Note For 3-wire systems use one white and two red leads. Do not connect the white leads. Insulate or terminate the unused white lead in a manner that prevents shorting to the ground. For 2-wire systems, connect both sets of leads. 3

Quick Start Guide Figure 2. Rosemount Series 185 Thermocouple Lead Wire Configuration Thermocouple terminal block Single element Dual element 3(-) 3(-) 1 (+) 1(+) 1 3 1 3 6 4 6(-) 4(+) Table 1. Rosemount Series 185 Thermocouple Characteristics Type Alloys (wire color) Sheath material Temperature range ( C) Limits of error interchangeability DIN EN 60584-2 Tolerance class J K N E T Fe (+ black), Cu-Ni ( white) Ni-Cr (+ green), Ni-Al ( white) Ni-Cr-Si (+ pink), Ni-Si ( white) Ni-Cr (+violet), Cu-Ni ( white) Cu (+brown), Cu-Ni ( white) 1.4541 (321 SST) 40 to 375, 375 to 750 1 1 2.4816 (Alloy 600) 40 to 375, 375 to 1000 1.5 C, 0.004 t 1 40 to 375, 375 to 800 1 1.4541(321 SST) 40 to 125, 125 to 350 0.5 C, 0.004 t 1 Note To distinguish the two sensors in Rosemount Dual 185 Sensors (flying lead or spring loaded styles), the lead wires of one sensor will be longer than the other sensor. 4

2.0 Sensor assembly dimensions 2.1 Sensor assembly without thermowell Rosemount 644 with LCD display meter Head or field mount transmitters Rosemount IP68 or IP65 connection heads Rosemount 644 Rosemount 248 Quick Start Guide Rosemount 3144 40 mm 25 mm Sensor with flying leads, terminal block, or spring-loaded adapter L L 11 mm L 16 mm Extensions N dimension measures from thread engagement point. N N N 11 mm 5

Quick Start Guide 2.2 Tubular thermowell sensor assembly Head or field mount transmitters Rosemount 644 with LCD display meter Rosemount 644 Rosemount 248 Rosemount IP68 or IP65, connection heads 40 mm 25 mm Sensor with flying leads or terminal block Threaded and flanged tubular thermowells N N N For straight threading, N dimension references bottom of hex. For tapered threading, N dimension references thread engagement point (bottom of thread). U NAMUR U NAMUR U GB GN U 6

Quick Start Guide 2.3 Barstock thermowell sensor assembly (1) Rosemount 644 with LCD display meter Head or field mount transmitters Rosemount 644 Rosemount 248 Rosemount IP 68 or IP 65 connection heads Rosemount 3144 40 mm 25 mm Sensor with flying leads, terminal block, or spring-loaded adapter L L 11 mm L 16 mm 11 mm Stand-alone extensions N N N 11 mm 11 mm 60 mm 60 mm 40 mm 60 mm Weld-in, threaded or flanged barstock thermowells T U U U U U N dimension measures from thread engagement point. This dimension is 80 mm for Class 1500 and 2500 flanges. 1. The Rosemount 644 is available with or without a LCD display. 7

Quick Start Guide 3.0 Product certifications Rev 1.13 3.1 European Directive information A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount. 3.2 Ordinary Location Certification As standard, the transmitter has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). 3.3 North America The US National Electrical Code (NEC) and the Canadian Electrical Code (CEC) permit the use of Division marked equipment in Zones and Zone marked equipment in Divisions. The markings must be suitable for the area classification, gas, and temperature class. This information is clearly defined in the respective codes. 3.4 Hazardous Locations Certifications USA E5 FM Explosionproof and Dust-Ignition proof Certificate: FM17US0170X Standards Used: FM Class 3600: 2011; FM Class 3611: 2004; FM Class 3615: 2006; FM Class 3810: 2005; ANSI/NEMA - 250: 1991 Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; T5( 50 C T a +85 C); Type 4X Canada E6 CSA Explosionproof and Dust-Ignition proof Certificate: 1063635 Standards Used: CSA C22.2 No. 0-M91, CSA C22.2 No. 25-1966, CSA C22.2 No. 30-M1986, CSA C22.2 No. 94-M91; CSA C22.2 No. 142-M1987, CSA C22.2 No. 213-M1987 Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; CL i, Div 2, GP A, B, C, D; ( 50 C T a +85 C) Europe E1 ATEX Flameproof Certificate: FM12ATEX0065X Standards Used: EN 60079-0:2012 + A11:2013, EN60079-1:2014, Markings: II 2 G Ex db IIC T6 T1 Gb, T6( 50 C T a +40 C), T5... T1( 50 C T a +60 C); 1180 8

Quick Start Guide Specific Conditions of Use: 1. See certificate for ambient temperature range. 2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments. 3. Guard the LCD cover against impact energies greater than 4 joules. 4. Flameproof joints are not intended for repair. 5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option N. 6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor prove does not exceed 130 C. 7. Non-Standard Paint options may cause risk from electrostatic discharge. Avoid installations that cause electrostatic build-up painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information. I1 ATEX Intrinsic Safety Certificate: Baseefa16ATEX0101X Standards: EN 60079-0:2012+A11:2013, EN 607960079-11:2012 Markings: II 1 G Ex ia IIC T5/T6 Ga (see certificate for schedule) Thermocouples; P i = 500 mw T6 60 C T a +70 C RTDs; P i = 192 mw T6 60 C T a +70 C RTDs; P i = 290 mw T6 60 C T a +60 C T5 60 C T a +70 C Specific Conditions of Use: 1. The equipment must be installed in an enclosure which affords it a degree of ingress protection of at least IP20. N1 ATEX Type n Certificate: BAS00ATEX3145 Standards: EN 60079-0:2012, EN 60079-15:2010 Markings: II 3 G Ex na IIC T5 Gc ( 40 C T a +70 C) ND ATEX Dust Certificate: FM12ATEX0065X Standards: EN 60079-0:2012+A11:2013; EN 60079-31: 2014 Markings: II 2 D Ex tb IIIC T130 C Db ( 40 C T a +70 C) Specific Conditions of Use: 1. See certificate for ambient temperature range. 2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments. 3. Guard the LCD display cover against impact energies greater than 4 joules. 4. Flameproof joints are not intended for repair. 5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option N. 6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 C. 7. Non-Standard Paint options may cause risk from electrostatic discharge. Avoid installations that cause electrostatic build-up on painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information. 9

Quick Start Guide International E7 IECEx Flameproof Certificate: IECEx FMG 12.0022X Standards: IEC60079-0:2011, IEC60079-1:2014-06 Markings: Ex db IIC T6...T1 Gb, T6(-50 C T a +40 C), T5 T1(-50 C T a +60 C) Specific Conditions of Use: 1. See certificate for ambient temperature range. 2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments. 3. Guard the LCD display cover against impact energies greater than 4 joules. 4. Flameproof joints are not intended for repair. 5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option N. 6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 C. 7. Non-Standard Paint options may cause risk from electrostatic discharge. Avoid installations that cause electrostatic build-up on painted surfaces, and only clean the painted surfaces with a damp cloth. If paint is ordered through a special option code, contact the manufacturer for more information. Brazil E2 INMETRO Flameproof Certificate: UL-BR 13.0535X Standards Used: ABNT NBR IEC 60079-0: 2013; ABNT NBR IEC 60079-1: 2016; ABNT NBR IEC 60079-31: 2014 Markings: Ex db IIC T6...T1 Gb T6 T1: ( 50 C T a +40 C), T5...T1: ( 50 C T a +60 C) Ex tb IIIC T130 C Db ( 40 C T a +70 C) Specific Conditions of Use: 1. See product description for ambient temperature limits and process temperature limits. 2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments. 3. Guard the LCD display cover against impact energies greater than 4 joules. 4. Consult the manufacturer if dimensional information on the flameproof joints is necessary. 5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature probes with Enclosure option N. 6. Care shall be taken by the end user to ensure that the external surface temperature on the equipment and the neck of DIN Style Sensor probe does not exceed 130 C. Japan E4 Japan Flameproof (0065 only) Certificate: TC17226 Markings: IIC T6; ( 20 C T a +65 C); Process Temperature: 20 C to +85 C Specific Conditions of Use: 1. The wiring shall be suitable for a temperature over 80 C. 10

Quick Start Guide EAC Belarus, Kazakhstan, Russia EM Technical Regulation Customs Union (EAC) Flameproof Certificate: RU C-US.GB05.B.00289 Markings: 1Ex d IIC T6 T1 Gb X Specific Conditions of Use: 1. See certificate for special conditions. IM Technical Regulation Customs Union (EAC) Intrinsic Safety Certificate: RU C-US.GB05.B.00289 Markings: 0Ex ia IIC T6 Ga X; Ga/Gb Ex ia IIC T6 X; 1Ex ia IIC T6 Gb X Specific Conditions of Use: 1. See certificate for special conditions. Korea EP Korea Explosionproof/Flameproof Certificate: 13-KB4BO-0560X Markings: Ex d IIC T6 T1; T6( 50 C T amb +40 C), T5 T1( 50 C T amb +60 C) Specific Conditions of Use: 1. See certificate. Combinations KD Combination of E1, E5, and E6 K1 Combination of E1, I1, N1, and ND KM Combination of EM and IM 11

Quick Start Guide Figure 3. Rosemount Temperature Sensor Declaration of Conformity EU Declaration of Conformity No: RMD 1059 Rev. N We, Rosemount, Inc. 8200 Market Boulevard Chanhassen, MN 55317-9685 USA declare under our sole responsibility that the product, Rosemount Model 65, 68, 78, 85, 183, 185, and 1067 Temperature Sensors manufactured by, Rosemount, Inc. 8200 Market Boulevard Chanhassen, MN 55317-9685 USA to which this declaration relates, is in conformity with the provisions of the European Union Directives, including the latest amendments, as shown in the attached schedule. Assumption of conformity is based on the application of the harmonized standards and, when applicable or required, a European Union notified body certification, as shown in the attached schedule. (signature) Vice President of Global Quality (function) Chris LaPoint (name) 7-Sept-2017 (date of issue) Page 1 of 2 12

Quick Start Guide c EU Declaration of Conformity No: RMD 1059 Rev. N ATEX Directive (2014/34/EU) FM12ATEX0065X - Flameproof Certificate Equipment Group II Category 2 G (Ex db IIC T6 T1 Gb) Harmonized Standards: EN60079-0:2012+A11:2013, EN60079-1:2014 FM12ATEX0065X - Dust Certificate Equipment Group II Category 2 D (Ex tb IIIC T130 C Db) Harmonized Standards: EN60079-0:2012+A2013, EN60079-31:2014 BAS00ATEX3145 - Type n Certificate Equipment Group II Category 3 G (Ex na IIC T5 Gc) Harmonized Standards: EN60079-0:2012+A11:2013, EN60079-15:2010 Baseefa16ATEX0101X - Intrinsic Safety Certificate Equipment Group II Category 1 G (Ex ia IIC T5/T6 Ga) Harmonized Standards: EN60079-0:2012+A11:2013, EN60079-11:2012 RoHS Directive (2011/65/EU) Harmonized Standard: EN 50581:2012 ATEX Notified Bodies FM Approvals [Notified Body Number: 1725] 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA SGS Baseefa Limited [Notified Body Number: 1180] Rockhead Business Park Staden Lane Buxton Derbyshire SK17 9RZ United Kingdom ATEX Notified Body for Quality Assurance SGS Baseefa Limited [Notified Body Number: 1180] Rockhead Business Park Staden Lane Buxton Derbyshire SK17 9RZ United Kingdom Page 2 of 2 13

Quick Start Guide Part Name China RoHS Rosemount 0065/0185 List of Rosemount 0065/0185 Parts with China RoHS Concentration above MCVs Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr +6) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Electronics Assembly Housing Assembly O O O O O O O O O O O O Sensor Assembly O O O O O O SJ/T11364 This table is proposed in accordance with the provision of SJ/T11364. O: GB/T 26572 O: Indicate that said hazardous substance in all of the homogeneous materials for this part is below the limit requirement of GB/T 26572. X: GB/T 26572 X: Indicate that said hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement of GB/T 26572. 14

Quick Start Guide 15

Quick Start Guide 16

Quick Start Guide 17

Quick Start Guide 18

Quick Start Guide 19

*00825-0200-2654* Quick Start Guide 00825-0200-2654, Rev EA Global Headquarters Emerson Automation Solutions 6021 Innovation Blvd. Shakopee, MN 55379, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RFQ.RMD-RCC@Emerson.com North America Regional Office Emerson Automation Solutions 8200 Market Blvd. Chanhassen, MN 55317, USA +1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 RMT-NA.RCCRFQ@Emerson.com Latin America Regional Office Emerson Automation Solutions 1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA +1 954 846 5030 +1 954 846 5121 RFQ.RMD-RCC@Emerson.com Europe Regional Office Emerson Automation Solutions Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland +41 (0) 41 768 6111 +41 (0) 41 768 6300 RFQ.RMD-RCC@Emerson.com Asia Pacific Regional Office Emerson Automation Solutions 1 Pandan Crescent Singapore 128461 +65 6777 8211 +65 6777 0947 Enquiries@AP.Emerson.com Middle East and Africa Regional Office Emerson Automation Solutions Emerson FZE P.O. Box 17033 Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates +971 4 8118100 +971 4 8865465 RFQ.RMTMEA@Emerson.com Linkedin.com/company/Emerson-Automation-Solutions Twitter.com/Rosemount_News Facebook.com/Rosemount Youtube.com/user/RosemountMeasurement Google.com/+RosemountMeasurement Standard Terms and Conditions of Sale can be found on the Terms and Conditions of Sale page. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and Rosemount logotype are trademarks of Emerson. National Electrical Code is a registered trademark of National Fire Protection Association, Inc. NEMA is a registered trademark and service mark of the National Electrical Manufacturers Association. All other marks are the property of their respective owners. 2017 Emerson. All rights reserved.