SharperImage.com T.E.N.S. Massager with Handheld Control Operating Manual

Similar documents
Electronic Pulse Massager

USER MANUAL. AccuMed AP210 Mini Electronic Pulse Stimulator AP210 USER MANUAL. V2.0.1 Revised: March 9, 2017

IF8000. Users Manual. Protocols. for Interferential Therapy

Sport EMS Toning Pads Instruction Manual

Dual Channels - TENS Electronic Pulse Massager Unit Model No.: MT-5180

USB Warming Gloves with Carbon Fiber Heating Elements Model No. MH-1000

home use only in accordance with the instructions provided in this manual. Please read these instructions carefully and retain for future use

USER MANUAL Please read the user manual carefully before using the product

OVER 100 CONTACT POINTS Thai Spa Massage Cushion Instruction Manual Item #GM Sakar International, Inc. All rights reserved.

Electronic Pulse Massager E4 (HV-F128-E)

IB-CB200GB _Layout 1 16/12/ :02 Page 1. Instruction Manual. Customer Service Number +44 (0) CB-200-GB

VIBRATION MASSAGE SEAT

Neck and Shoulder Massager DEEP RELIEF FOR HARD-TO-REACH MUSCLES

MAINTENANCE INSTRUCTIONS

The ORIGINAL. User manual for neck and shoulder massager NM-089 WITH THE ZIPPER PREMIUM

INSTRUCTION MANUAL USJ-101

USER/MAINTENANCE INSTRUCTIONS IMPORTANT SAFETY

Shiatsu Foot Massager +heat +air

uknead Bella (ND-8000) User Manual

Instruction Manual. Head & Eye Massager with Acupressure and Heat Compression.

OGCF2002A User Manual

DR. CLARK FAR INFRARED HEATING PAD

IMPORTANT SAFETY INSTRUCTIONS

Find thousands more great ideas online

humantouch.com use & care manual

LIMITED ONE YEAR WARRANTY

Massaging Heating Pad

VibraSpa. 2 limited warranty. Luxury Foot Spa. TWO YEAR LIMITED WARRANTY (Valid in USA only) Instruction Manual and Warranty Information.

DR. CLARK FAR INFRARED HEATING PAD

Health Frequency Therapy Device. Instruction Manual

S10 Deep-Kneading Shiatsu & Tapping Seat Topper

INFRARED MASSAGER Instruction Manual

User Manual. Non-contact Infrared Thermometer.

Ozone Waterfall Foot and Leg Spa Bath Massager

HAND-HELD INFRARED MASSAGER

TWO YEAR LIMITED WARRANTY (Valid in USA only) Luxury Foot Spa FootREJUVENATOR. with Wet & Dry Massage Center

MG 510 To Go D Klopf-Massagegerät r Прибор для похлопывающего Gebrauchsanweisung... 2 массажа G Tapping massager Инструкция по применению..

SAD Light Pad. Product Code: DL Unit Description

BIO-SPECTRUM TREATMENT DEVICE

SAD Day Light. Product Code: DL Unit Description

PARTS DECSRIPTION. Restwell Massage Chair (MC003) Owner s Handbook

Service Centers: Conair Consumer Products Inc. 156 Parkshore Drive. Brampton, Ontario L6T 5M1

BubbleSpa Ultra. Luxury Foot Bubbler

IMPORTANT SAFETY INSTRUCTIONS

NEOSAUNA SERENITY SAUNA INSTRUCTION MANUAL Read all instructions carefully before using this wooden sauna room SKUS: SAU-SER-4C-B, SAU-SER-4C-C

Shiatsu Neck and Shoulder Massager KNEADING MASSAGE FOR HARD-TO-REACH MUSCLES

INSTRUCTIONS AND WARRANTY

Ultrasonic Pain Relief Massager INSTRUCTION MANUAL

Shiatsu Foot Massager. Instruction Manual KH385L-B

Massaging Heating Pad

Owner s Manual Super-Slim Four-Way Cassette

Pink Magnetic Elliptical Bike

hi tsu eg M 55 ger G U.S. Jaclean, Inc. INSTRUCTION MANUAL Foot & Calf Massager THE RELIEF THAT ALL LEGS CRAVE USJ-559A IMPROVED!

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI 40 CE

PORTABLE AIR CONDITIONER

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI10

OPERATING INSTRUCTION

Shiatsu Foot Massager

EXTERNAL CARDIAC AMBULATORY TELEMETRY

SHIATSU MASSAGE SEAT CUSHION Item No Quick Start Guide

INSTRUCTIONS AND WARRANTY

IMPORTANT SAFETY INSTRUCTIONS

CLETEF-786. Infrared Thermometer Instruction Manual

HELO FAR-INFRARED CABIN INSTRUCTION MANUAL HSI80

Instruction Manual. Contents. OMRON Cushion Massager HM-340. Before Using the Device. Using the Device. Maintenance and Troubleshooting

PORTABLE AIR CONDITIONER

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-670EX/E300-CX

Before you begin, carefully read the installation instructions below. Observe all local electrical safety and plumbing codes.

KSD-35 DR11 KUE-35 DVN11

Intelligent Super Toilet AFC230 User Instruction Manual

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-530 BH

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

"HTT" is the preferred technology of the ACCO.

Complete Pedicure Foot Spa

Decorative Shiatsu Massage Cushion Instruction Manual

The Ionzyme DFII System

WARNING: IF YOU THINK THE POWER IS OFF WHEN THE SWITCH IS OFF, YOU RE WRONG.

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

INFRARED WOODEN SAUNA ROOM INSTRUCTION MANUAL IG-540BX/B400-X. Important: Please record your serial number here

Advanced averaging of last 3 readings 30 memory storage with date/ time stamp Extra large digital display Semi-automatic

SHIATSU MASSAGE CUSHION

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

Table of contents Warnings and Cautions... 2 Location of Parts, Controls and Indicators... 7 Foot Spa Operation... 9 Using the Foot Spa...

EQUIVITAL EQ-01 VITAL SIGNS MONITOR USER APPLICATION GUIDE

Operating Instructions Air Conditioner

Leben im Bad Living bathrooms. St.Trop

w a r m t h and c a r e for you and your f a m i l y.

PEDICUTE PORTABLE SPA

INSTRUCTIONS AND WARRANTY MODEL NO. SFS-107. Salton Foot Spa

PINK MAGNETIC RECUMBENT BIKE

PERFORMANCE SLIMMING BELT

S-Series 3 Person Infrared Sauna IG-870-SH/S870 User Manual

ENGLISH. The following symbols are used in the operating instructions and on the type plate: Warning of risks of injury or health hazards.

ULTRASONIC MIST FAN 80W A GILMAN GROUP BRAND

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Operating Instructions

Infrared sauna SUN S Pure Infra User Manual

INSTALLATION AND USER MANUAL

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Transcription:

SharperImagecom TENS Massager with Handheld Control Operating Manual

Contents Introduction 3 Safety warnings 4-5 Set up 6 Operating the product 7-8 Cleaning and maintenance 9 Trouble shooting 10 Positions for use 11 2

Introduction The Sharper Image TENS Massager with Handheld Control delivers electric pulses to tired and sore muscles These pulses are generated by the device and delivered through electrodes on the skin to trigger contractions of the muscles It is portable, compact and stylish in design The device has six auto operational programs represented by six selection buttons of body areas The LCD remote displays information about the mode, intensity and time Indications for Use To be used for temporary relief of pain associated with sore and aching muscles in the shoulder, waist, back, arm, and leg, due to strain from exercise or normal household and work activities Features of the TENS Massager with Remote Control: Touchscreen with backlight Lock screen function Power: DC 6V, 4 AAA batteries Size: 228x748x079 inch Weight: 487 oz Two output channels Adjustable intensity Accessories included: 4 electrode pads, 2 electrode wires and 4 AAA batteries 3

Safety warnings Do not use this device if you have an implanted defibrillator or implanted metallic devices Such use could cause electrical shock, burns, electrical interference or death If you have one of the following conditions, please consult with your physician before purchasing or using this device Acute disease, malignant tumor, infective disease, pregnant, heart disease, high fever, abnormal blood pressure, lack of skin sensation or an abnormal skin condition, any condition requiring the active supervision of a physician Do not use this device while driving Do not use this device while sleeping Do not use this device in high humidity areas such as a bathroom Keep the device away from wet, high temperature and direct-sunlight place Keep this device out of reach of children Stop using this device at once if you feel pain, discomfort, dizziness or nausea and consult your physician Do not attempt to move the electrode pads while the device is operating Do not use the device around the heart, on the head, mouth, pudendum or blemished skin areas Do not apply stimulation of this device in the following conditions: (1) across the chest because the introduction of electrical current into the chest may cause rhythm disturbances to the which heart, could be lethal; (2) over painful areas Please consult ith with your physician before using this device if you have painful areas; (3) over open wounds or rashes, or over swollen, red, infected, or inflamed areas or skin eruptions (eg, phlebitis, thrombophlebitis, varicose veins) Apply stimulation only to normal, intact, clean, healthy skin; (4) in the presence of electronic monitoring equipment (eg, cardiac monitors, ECG alarms) The electronic Stimulator may not operate properly when the electrical stimulation device is in use; (5) while operating machinery, or during any activity in which electrical stimulation can put you at risk of injury; (6) on children Be aware of the following (1) to consult with your physician before using this device The simulation with the device may: i cause lethal rhythm disturbances to the heart in susceptible individuals, and, ii disrupt the healing process after a recent surgical procedure; 4

(2) that the device is not effective for pain of central origin, including headache; (3) that the device is not a substitute for pain medications and other pain management therapies; (4) that the device has no curative value; (5) that the device is a symptomatic treatment and, as such, suppresses the sensation of pain that would otherwise serve as a protective mechanism; (6) that the long-term effects of electrical stimulation are unknown; (7) that the user may experience skin irritation, burns or hypersensitivity due to the electrical stimulation or electrical conductive medium (gel); (8) if the user has suspected or diagnosed epilepsy, the user should follow precautions recommended by his or her physician; (9) to use caution if the user has a tendency to bleed internally, such as following an injury or fracture; (10) use caution if stimulation is applied over the menstruating uterus; (11) use caution if stimulation is applied over areas of skin that lack normal sensation; (12) stop using the device if the device does not provide pain relief; and, (13) use this device only with the leads, electrodes, and accessories that the manufacturer recommends Medical Electrical Equipment needs special precautions regarding electromagnetic compatibility (EMC) and needs to be installed and put into service according to the EMC information provided Portable and mobile radio frequency (RF) communication equipment can affect Medical Electrical Equipment Environmental condition for transport and storage Easily fragile product Keep the product in the dry away place from water and rain Product package should be recycled eded Stacked up 4 cartons at most Temperature range: 0 o c to 48 o c Humidity: 10% to 85% Atmospheric pressure: 400hPa to 1060hPa 5

Setup Unpack the box of the product, take the product and batteries out, place the batteries into the device at its back compartment, and connect the electrode pads into the device through the wires 6

Operating the product To begin 1 Install 4 AAA batteries into the device Match the positive electrode and negative electrode in the right direction; 2 Connect 1 pair of electrode wire into the upper left hole of the device and another pair of electrode wire in the upper right hole 3 Attach the electrode pads (connecting to the electrode wire) to the treatment area, such as shoulder 4 Turn the power/intensity switch knob to 1 The screen should be bright with blue light This means the device is ready to begin treatment 5 Press one of the function keys to start treatment, such as Shoulder or Mode1 6 Rotate the Switch Knob to adjust the intensity 7 Press TIMER to adjust the time Note: Start from the lowest speed and intensity, and then gradually adjust to a comfortable level on a scale level from 1 to 10 7

Right output hole Left output hole LCD screen Auto program buttons Function buttons Timer Auto program buttons Electrode wire Electrode E lectrode pads Recommended practices: 1 Duration is 10-15 minutes for each treatment area 2 Frequency is 2 times per day per area 3 Intensity and speed selections are based upon the level of your comfort 8

Cleaning and maintenance Please use water or neutral detergent to clean the device first then using the dry cloth to wipe it again The electrode pads coming with the device are disposable, and should be replaced when their adhesiveness becomes worse Contact the seller for replacements Do not let the sticky side of the pad touch anything, including the greasy finger tips 9

Trouble Shooting If your device is not operating properly, please check it for the following problems or conditions MALFUNCTION CAUSE SOLUTION Stimulation is weak or not existent Are the electrode heads in close contact with the skin? Do the electrode heads touch each other? Remove, clean and place back on the skin If so, then separate Are the wires connected to Disconnect, clean and the electrode heads and the reconnect all the parts main device properly? Are the batteries dead? Replace the batteries Skin turns red Is treatment time too long? Stop and consult your physician if symptom lasted Skin feels uncomfortable Are electrode pads dirty? Clean with damp cloth or replace Do the electrode pads touch Remove and place again on the skin closely? the skin Device does not turn on Batteries installed Remove and install correctly? batteries Are batteries dead? Replace the batteries Pads are not sticky Pads get deteriorative Contact vendor for replacements Customer Service Sharper Image branded items purchased from SharperImagecom include a 1-year limited warranty For assistance, please call 1 (877) 210-3449 10

Positions for use 11