Demonstration of 2nd Generation Ducted GE "Brillion" Hybrid Water Heater in the PNNL Lab Homes

Similar documents
Space Conditioning Interactions with Heat Pump Water Heaters: A Test in the PNNL Side-by-Side Lab Homes

Demand-Response Performance of Sanden Unitary/Split-System Heat Pump Water Heaters

Energy Efficient Options for Residential Water Heating

Energy-Efficiency Options for Residential Water Heating

PNNL Lab Home Results for CO2 Combi System Stress Tests

Hot Water Distribution System Losses in a Net-Zero Home

Effect Of Setup Thermostat Schedule On Heat Pump Water Heater Energy Consumption, Coefficient Of Performance And Peak Load

CO 2 Heat Pump Lab Test Results. Presented by Ken Eklund 2016 ACEEE Hot Water Forum February 22, 2016

Residential Water Heating

The Revised Method of Test for Residential Water Heating and Its Impact on Incentive Programs

Smart Water Heater Project Update. Residential Two-way Water Heater Load Control Pilot

Evaluating Peak Load Shifting Abilities and Regulation Service Potential of a Grid Connected Residential Water Heater

Heat Pump Water Heaters: Laboratory and Field Evaluation of New Residential Products

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Commercial Water Heater Performance: Laboratory Testing and Modeling

Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate

Field Evaluation of Pre-Commercial Residential Gas Heat Pump Water Heaters

NAECA Water Heaters. Tankless (Instantaneous) < 2 gallons Natural Gas 75,000 Btu 200,000 Btu Oil 105,000 Btu 210,000 Btu Electric

Evaluating Domestic Water Heater Performance for NY Homes NYSERDA Agreement 15606

Field Testing Results for Residential Gas-Fired Heat Pump Water Heaters

The Opportunity for Gas-Fired Heat Pump Water Heaters

PG&E s Applied Technology Services Hot Water Technology Performance Laboratory

Hot Water System Performance Testing at PG&E s Applied Technology Services: Mimicking a Full-Service Restaurant in the Laboratory

GUIDELINES FOR SIZING WATER HEATERS California Conference of Directors of Environmental Health September, 1995

Heat Pump Water Heater Technology Development. EEBA High Performance Home Summit Ed Vineyard Oak Ridge National Laboratory

The Importance of Integrated Design, Commissioning, and Building Tuning: A Grocery Store Case Study

Energy Efficiency Potential of Heat Pump Water Heaters in Commercial Buildings

Smoke Layer Height and Heat Flow through a Door

THERMAL ICE STORAGE: Application & Design Guide

Savings Without Sacrifice

Reduced Order WECC Modeling for Frequency Response and Energy Storage Integration

Development Of A Low-Cost Heat Pump Water Heater For Residential Applications

Data driven insights from the nation s deepest ever customer energy research

Systems Engineering Approach to Development of Advanced Residential Buildings

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use

Sacramento Municipal Utility District Heat Pump Water Heater Field Testing Report

How to Heat Water in All-Electric Homes & Apartments?

Heat Pump Water Heaters: A Key Energy Technology for California

Metcraft Power Soak Performance Test

Emerging Technologies Update

VARIABLE REFRIGERANT FLOW FOR LODGING

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Hot Water. The Efficiency Challenge!

Copyright 2003 IBACOS, Inc. All rights reserved.

TOP TEN 2018 Energy Efficiency Technologies for the U.S. Building Sector

Continuous Commissioning: A Valuable Partner to Retrofit Projects

97.501B. Prepared by: (415) Sponsored By: Final Report. Author: Presented at: ASHRAE. Meeting SF Me!

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

CONTROLLED CHILLED BEAM PUMP MODULE

Study Final Report. Priority Cool Refrigerant Study

Why Pay for Two Condensing Systems When One Will Do?

Computing Services Center

CALIFORNIA DREAMIN REAL-WORLD IMPLICATIONS OF THE ELECTRIFICATION MOVEMENT FOR A CALIFORNIA PASSIVE HOUSE

Zero Net Energy Retrofit Projects The Domes Final Performance Assessment & Verification

Sizing water heaters to provide sufficient hot water efficiently LEARN THREE METHODS YOU SHOULD BE USING TO DESIGN EFFICIENT SYSTEMS

NEEA Report: Laboratory Assessment of AirGenerate ATI80 Heat Pump Water Heater

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

Beneficial Electrification: Exploring the Aggregation of Water Heaters

This presentation is posted for public use. ACEEE does not endorse any product or service.

Characterizing large residential appliance peak load reduction potential utilizing a probabilistic approach

Softened Water Benefits Study: Energy Savings Detergent Savings. Independent studies demonstrate the link. Executive Summaries

OSU Alumni Center Phase I Implementation Review. Oregon State University 130 Oak Creek Bldg. Corvallis, Oregon

Product Offering for 2017

<<Date>> <<Recipient>> <<Address>>

Mul$family Buildings: Real World Monitored Data on Hot Water Energy and Water Use

From Energy Guzzler to Near-Zero Energy Home: Lessons from the Phased Deep Retrofit Project

CONTROLLED CHILLED BEAM PUMP MODULE

Commercial Refrigeration Load Shape Project. Forum Presentation June 18, 2015

Hot Water a Hot Commodity Better Buildings by Design, February 2012 Burlington, VT

Using the Time Delay of Radiant Systems to the Grid s Advantage

InterNACHI Home Energy Inspection for th Street

Farm Energy Audit Workshop

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Introduction ABSTRACT

Radiant Cooling Nonresidential HVAC Stakeholder Meeting #2

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

2019 ETCC Webinar Series. ETCC-CA.com/webinars

Prepared by: (415) With. High. Prepared for: Final Report June 27, Contributors: Tom. Me!

Demand Response Potential of Residential Appliances Clothes Washer (LG)

Business Energy Efficiency Incentives 2007

Performance of Solar Water Heating Systems in the United States

Smart Appliances: Path to a Smart Grid Enabled Home. Charlotte Skidmore, Dir Energy & Environmental Policy. June 4, 2012

Demand-Controlled Ventilation For Commercial Kitchens

Southern California Gas Company Customer Programs Department

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

A STUDY OF THE IAQ OF RESIDENTIAL BUILDINGS IN SINGAPORE

Indoor Horticulture HVAC System Evaluation Project

OFF-GRID COMMERCIAL DIRECT CURRENT GRID SYSTEM

Sustainable Hot Water: Better Design, Delivery, and Use

2017 Residential Wi-Fi Thermostat DR Evaluation

IES Whole-Building Energy Model Baseline Energy Model Input/ Output Report. East Liberty Presbyterian Church East Liberty Presbyterian Church

A Model of In-Home Hot Water Distribution Systems Energy Losses Using EPANET, Public Domain Software For Pipe Networks

Food Service Technology Center

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Energy Management Wiring Guide

Grid Interactive Water Heater Pilot Demonstration in Oahu, Hawaii

Distribution Restriction Statement

Transcription:

Demonstration of 2nd Generation Ducted GE "Brillion" Hybrid Water Heater in the PNNL Lab Homes 2013 ACEEE Hot Water Forum Sarah Widder Research Engineer Pacific Northwest National Laboratory

Project Participants Project Sponsors: DOE Building America Program/Bonneville Power Administration Contractor: PNNL Principal Investigators: Graham Parker/Sarah Widder, PNNL Other Project Stakeholders: GE Appliances**; Northwest Energy Works (NEW)**; Regional Technical Forum (RTF); Regional/National Utilities & Efficiency Advocates; PNW Manufactured Homes Industry; Appliance, Plumbing, HVAC Industry; Residential Customers **Cost sharing partners.

Project Synopsis Evaluate the performance and demand response (DR) of the Gen II GE GeoSpring HPWH under a number of operating configurations in Lab Homes. Exhaust ducted HPWH vs. standard WH & unducted HPWH (winter/summer). Exhaust & supply ducted HPWH vs. unducted HPWH (winter/summer). DR characteristics of unducted 50 gal HPWH vs. electric resistance 50 gal WH. Experiments conducted with controlled & measured variables under identical simulated occupancy in each home.

HPWH DR Project Background Previous modeling efforts at PNNL and elsewhere have demonstrated the potential of electric resistance water heaters to provide a variety of grid services (peak curtailment, regulation, and voltage/frequency response) in the PNW and nationwide (Lu et al, 2011; Diao et al 2012) The demand response characteristics of HPWH are not currently well understood There is concern for some utilities (and recognition by DOE) that HPWH may conflict with DR program goals 4

HPWH Experimental Design Two side-by-side GE Brillion-enabled HPWH One operated in Heat Pump mode with no ducting or back-up electric resistance elements One operated in Standard mode with electric resistance elements only Installed in Lab Homes conditioned space 5

HPWH DR Project Specifics Experiment A.M. Peak Curtailment P.M. Peak Curtailment EVE Peak Curtailment INC Balancing Experiment Description Turn off heating elements Turn off heating elements Turn off heating elements Turn off heating elements Time Duration Purpose of Experiment 7:00 a.m. 3 hours Evaluate HPWH load shedding potential (dispatchable kw and thermal capacity) as compared to electric resistance baseline to manage peak load 2:00 p.m. 3 hours Evaluate HPWH load shedding potential (dispatchable kw and thermal capacity) as compared to electric resistance baseline to manage peak load 6:00 p.m. 3 hours Evaluate HPWH load shedding potential (dispatchable kw and thermal capacity) as compared to electric resistance baseline to manage peak load 2:00 a.m. 8:00 a.m. 2:00 p.m. 8:00 p.m. DEC Balancing Set tank temp to 135 F 2:00 a.m. 8:00 a.m. 2:00 p.m. 8:00 p.m. 1 hour Evaluate HPWH potential to provide balancing reserves for dispatchable kw as compared to electric resistance baseline 1 hour Evaluate thermal capacity of HPWH, as compared to ERWH, when temperature set point is increased to 135 F

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] 12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM 12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] Water Heater Energy Use [Wh]) Baseline Performance ER: Lab Home A Lab Home B 1800 1600 1400 1800 1600 1400 1200 1200 1000 800 600 400 200 1600 5/18/2013 5/19/2013 6/3/2013 6/4/2013 6/5/2013 LHA ER 6/6/2013 Baseline Average 1000 800 600 400 200 LHB ER Baseline 5/18/2013 5/19/2013 5/23/2013 5/27/2013 5/28/2013 Average 0 1400 0 Time 1200 Time 1000 800 600 400 200 0 Time 7

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] 12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM 12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] Water Heater Energy Use [Wh] Baseline Performance HP: Lab Home A Lab Home B 600 600 500 500 400 400 5/31/2013 300 5/25/2013 5/29/2013 5/30/2013 300 6/1/2013 6/2/2013 6/3/2013 200 100 700 5/31/2013 6/1/2013 LHA Average HP BL 200 LHB HP BL 100 6/4/2013 6/5/2013 6/6/2013 Average 0 600 0 Time 500 Time 400 300 200 100 0 Time 8

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Power [W] HPWH Efficiency Evaluation 61.7 ± 1.7% energy savings from HPWH as compared to ERWH 5000 4500 4000 3500 3000 ERWH HPWH 2500 Also note: Power draw relatively fixed for HPWH and ERWH for individual unit HPWH operates much more than ERWH 2000 1500 1000 500 0 Time Water Heater Type Baseline Daily Energy Use (W h/day) ERWH 20,073 ± 348 HPWH 7,684 ± 119

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] Extrapolating to Population Performance Operating time each hour defines DR performance Can be extrapolated to population of water heaters due to average load shape 5000 4500 4000 3500 3000 2500 2000 1500 ERWH w DR HPWH w DR ERWH Baseline HPWH Baseline 1000 500 0 Time 10

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Power [W] PM Peak Curtailment Peak impact (W) commensurate with peak draw ERWH = 4,650W; HPWH = 587W ERWH HPWH 5000 4500 4000 3500 3000 2500 2000 1500 1000 500 0 Time 11

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] PM Peak Curtailment However, duration of draw impacts average power draw over the DR event 4000 3500 3000 2500 recovery ERWH = 18% of 3 hr event HPWH = 54% of 3 hr event 2000 1500 1000 500 HPWH average peak reduction ERWH average peak reduction ERWH w DR HPWH w DR ERWH Baseline HPWH Baseline 0 Time 12

1:00am 2:00am 3:00am 4:00am 5:00am 6:00am 7:00am 8:00am 9:00am 10:00am 11:00am 12:00pm 1:00pm 2:00pm 3:00pm 4:00pm 5:00pm 6:00pm 7:00pm 8:00pm 9:00pm 10:00pm 11:00pm Hot Water Delivery Temperature [F] PM Peak Curtailment Energy use reduced related to decrease in tank temperature experienced in HPWH Recovery of ER tank temperature associated with recovery spike in energy use in hour following DR event Experiment P.M. Peak Curtailment 130 125 120 115 110 105 100 95 90 85 80 WH Mode Duration Average Power Draw Impact (W) LHB_Out_WaterTemp LHA_Out_WaterTemp Time Average Energy Impact during DR Event (W h) Average Daily Energy Impact (W h/day) HP 3 hours 350 965 533 ER 3 hours 924 2,463 213 13

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] DEC Balancing Events 4500 Ability of water heater to respond based on operating time in baseline (no DR) operation HP = 91% operating ER = 31% operating 1-hr DEC balancing events exhibit rebound following DR event Based on control logic of GE water heater 4000 3500 3000 2500 2000 1500 1000 500 0 Experiment Morning DEC Balancing Event WH Mode Duration Time Average Power Draw Impact (W) Average Energy Impact during DR Event (W h) ERWH w DR HPWH w DR ERWH Baseline HPWH Baseline Average Daily Energy Impact (W h/day) HP 1 hour 26 26 689 ER 1 hour 1,305 1,305 1,309 14

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Power [W] DEC Balancing Event Rebound Response GE control strategy references one thermocouple (near top element) 7000 6000 5000 4000 28% increased energy use ERWH HPWH Increased energy use due to stratification of 135 F water Stratification of temperature causes unusual coast and rebound behavior 3000 2000 1000 0 HP already operating almost constantly Time 15

Increased Tank Temperatures Both ERWH and HPWH are capable of reaching temperatures of 170 F with modified controls and minimal hardware Increased energy use of 5,550 Wh per event ERWH = 71 minutes of constant operation at 4,650 W (with no water draws) HPWH = 4 hours of constant operation at 587 W (with no water draws) November 11, 2013 16

Key Findings: Peak Curtailment and INC Balancing Events In general, HPWH provides 38% of the peak reduction or INC balancing response capability of ERWH Both HPWH and ERWH can effectively perform peak curtailment services in the morning, afternoon, and evening periods HPWH has lower power draw but operates (on average) 2.68 times as often at the ERWH for the water hot water load Decreased energy use observed for HPWH due to lower tank temps, however this may not be noticeable for most homeowners ERWH exhibited significant rebound following DR event, which may be problematic (this would also apply to HPWH operating in Hybrid mode) This analysis does not account for inherent peak load reduction from increased efficiency of HPWH (61.7%) INC balancing results very similar November 11, 2013 17

Key Findings: DEC Balancing Events Ability to respond very dependent on draw profile ERWH had significantly better dynamic ramping capability to increase load (baseline operation = ~25% of hour) HPWH already operating for a majority of each hour when a DEC event was initiated Response varies based on time of day Morning ERWH has 50 times the response capability of HPWH because HPWH is already operating constantly to meet 10 gallon draw Afternoon and evening ERWH has 6 to 8 times the response capability of the HPWH due to reduced loads Late night ERWH has only 2.12 times the response capability of the HPWH because ERWH satisfies the increase in tank temperature to 135 F in 16 minutes, whereas the HPHW takes the entire hour Higher tank temperatures could increase the response from both HPWH and ERWH

DR Results Summary Experiment Duration Water Heater Mode Average Power Draw Impact (W) Average Energy Impact During DR Event (W h) Average Daily Energy Impact (W h/day) Number Equivalent HPWH/ ERWH Peak 3 hours HP 439 1,285 498 2.64 Curtailment ER 1,158 3,320 258 INC 1 hour HP 442 442 159 2.67 Balancing* ER 1,185 1,185 86 DEC 1 hour HP 220 220 158 17.1** Balancing ER 1,174 1,174 1,543 * = does not include 2 a.m. INC balancing event, for which both water heaters had zero load. ** = ranges from 2.12 for 2 a.m. event to 50.6 for 8 a.m. DEC event, when HPWH ramping capability is significantly decreased. November 11, 2013 19

Future Experiments These experiments are only a initial indication of the relative response of HPWHs as compared to ERWHs under a given, high hot water draw profile with GE GeoSpring Hybrid HPWH Further research is required, including: Explore ERWH response to DEC balancing events where the events are more spread out and with a standard ERWH to better characterize coast and rebound effect Characterize the DEC response of ERWH and HPHW with elevated temperatures more fully Determine effect of different hot water draw profiles on the results Extrapolate experimental results from individual water heaters to populations of water heaters to determine the feasibility of HPWHs for performing DR functions at the program level using population models, such as PNNL s GridLAB-D (www.gridlabd.org) Assess cost implications of performing DR with HPWH vs ERWH

Project Deliverables Deliverable Report Summarizing DR Findings (includes descriptive graphs & tabulated summary data) Clean 1-min data of WH kw, kva, water flow, and inlet & outlet temps for all experiments Available At labhomes.pnnl.gov Late 2013 November 11, 2013 21

Questions? November 11, 2013 22

Back Up Slides November 11, 2013 23

The PNNL Lab Homes Goal is to demonstrate an intelligent, energy efficient, and grid responsive home retrofit over a period of five to seven years which achieves 50% whole house energy savings.

PNNL Project Team PNNL NEW Graham Parker Staff Engineer, Project Manager Sarah Widder, Engineer, Principal Investigator Viraj Shrivastava, Engineer, DR Lead Bora Akoyl, Senior Engineer, DR Engineer Vrushali Mendon, Engineer, Energy Modeling Nathan Bauman, Engineer, Metering Erica Johnson, Energy Modeling Brady Peeks, Engineer/Manufactured Homes GE Appliances Jonathan Smith/Scot Shaffer, Engineers/Software & Hardware Efficiency Solutions (subcontractor) Greg Sullivan, Principal/Metering & Analysis

Monitoring Approach Monitored Parameter Whole House Electrical Power and Circuit Level Power HPWH Electrical Power Electric Power for HPWH Fan Power for Electric Heaters Monitoring Monitored Method/Points Variables Electrical Power Measurements 1 Campbell data acquisition system with 42 current transducers at electrical power mains and panel kw, amps, volts Temperature Measurements Inlet Water Temperature Insertion thermocouple Temp., F Outlet Water Temperature Insertion thermocouple Temp., F Outlet Water Flow Rate Turbine flow meter, in line with hot water outlet prior to mixing valve Flow Rate Measurements Flow rate, gallons per minute (gpm) Data Application Comparison and difference calculations between homes of power profiles time-series energy use differences and savings Characterize impact of incoming water temperature on HPWH performance Monitor outlet water temperature as proxy for tank temperature Verify water draws are in accordance with specified profile Existing or New? Existing November 11, 2013 26 New New New

Hot Water Draw Profile Performance very dependent on hot water draw profile Draw profile PNNL selected representative of typical daily draw pattern for group of homes Based on Building America House Simulation Protocol 125 ºF set point Based on LBNL Meta-Analysis recently performed by Lutz and Melody (2012) Fixed 1.5 gpm flow rates Tank water heater performance more dependent on volume of draw than frequency of draws Consistent with LBNL study of typical flow rates (1 to 1.5 gpm) and duration (1 to 4 minutes in length) Selected high draw volume to explore worst-case scenario impacts on tank temperature and maximum availability of DR resources Initially simulated 97 gal/day, consistent with LBNL study s high daily draw volume (98.04 gal/day) Had to increase flow rates to 2 gpm to achieve consistent performance home to home, increasing draw volume to 130 gal/day 27

Water Use [gal/hr] Hot Water Draw Profile 45 BA House Simulation Protocol BPA HPWH Test Design Loads PNNL Lab Homes CSA Standard 40 35 30 25 20 15 10 5 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Hour of the Day Profile Daily Hot Water Use (gal/day) Building America House Simulation 97 (6 people) Protocol BPA HPWH Evaluation 90 (4 people) Canadian Test Standard 68.8 ( high usage ) PNNL Lab Homes 130 28

Building America House Simulation Protocol Source: Hendron and Engebrecht 2010. November 11, 2013 29

Canadian Standards Association Hot Water Draw Profile

Occupancy Simulation: Occupancy Hours of Day Simulation Strategy Simulated Watts Load Locations 1 a.m. 7 a.m. 3 60-Watt table lamps 180 Lamps in master and each bedroom 7 a.m. 8 a.m. 3 60-Watt table lamps 180 Lamps in master and each bedroom 8 a.m. 9 a.m. 1 60-Watt table lamp 60 Lamp in master bedroom 9 a.m. 4 p.m. 1 60-Watt table lamp 60 Lamp in master bedroom 4 p.m. 5 p.m. 1 60-Watt table lamp 60 Lamp in master bedroom 5 p.m. 6 p.m. 2 60-Watt table lamps 120 Lamps in master and East bedroom 6 p.m. 9 p.m. 3 60-Watt table lamps 180 Lamps in master and each bedroom 9 p.m. 12 p.m. 3 60-Watt table lamps 180 Lamps in master and each bedroom Wattage Totals 3180

Occupancy Simulation: Lighting Hours of Day Simulation Strategy Simulated Watts Load Locations 1 a.m. 4 a.m. Ceiling fixture, 1 60-Watt lamp 60 Hall fixture 4 a.m. 5 a.m. Ceiling fixture, 2 60-Watt lamps 120 Entry and living room fixtures 5 a.m. 6 a.m. 2 ceiling fixtures, 2 60-Watt lamps each 240 Kitchen fixtures 6 a.m. 7 a.m. 2 ceiling fixtures, 2 60-Watt lamps each 240 Kitchen fixtures 7 a.m. 8 a.m. 2 ceiling fixtures, 2 60-Watt lamps each 240 Kitchen fixtures 8 a.m. 9 a.m. Ceiling fixture, 2 60-Watt lamps 120 Kitchen fixtures 9 a.m. 3 p.m. Ceiling fixture, 1 60-Watt lamp 60 Hall fixture 3 p.m. 4 p.m. Ceiling fixture, 2 60-Watt lamps 120 Entry and living room fixtures 4 p.m. 5 p.m. 2 ceiling fixtures, 2 60-Watt lamps each 240 Kitchen fixtures 5 p.m. 6 p.m. 3 ceiling fixtures, 2 60-Watt lamps each 360 Kitchen and entry fixtures 6 p.m. 7 p.m. 5 ceiling fixtures, 2 60-Watt lamps each 600 Master, kitchen, and 2 bedroom fixtures 7 p.m. 8 p.m. 5 ceiling fixtures, 2 60-Watt lamps each 600 Master, kitchen, and 2 bedroom fixtures 8 p.m. 9 p.m. 5 ceiling fixtures, 2 60-Watt lamps each 600 Master, kitchen, and 2 bedroom fixtures 9 p.m. 10 p.m. 4 ceiling fixtures, 3 60-Watt lamps each 420 Master, kitchen and hall fixtures 10 p.m. 11 p.m. 2 ceiling fixtures, 2 60-Watt lamps each 240 Kitchen fixtures 11 p.m. 12 p.m. Ceiling fixture, 1 60-Watt lamp 60 Hall fixture Wattage Totals 4800

Occupancy Simulation: Equipment Hours of Day Simulation Strategy Duration of Load (Minutes) Simulated Watts Load Locations 1 a.m. 2 a.m. One 500 W & one 1,500 W wall heater 5 170 Living/dining room 2 a.m. 3 a.m. One 500 W & one 1,500 W wall heater 5 157 Living/dining room 3 a.m. 4 a.m. One 500 W & one 1,500 W wall heater 4 149 Living/dining room 4 a.m. 5 a.m. One 500 W & one 1,500 W wall heater 4 148 Living/dining room 5 a.m. 6 a.m. One 500 W & one 1,500 W wall heater 4 147 Living/dining room 6 a.m. 7 a.m. One 500 W & one 1,500 W wall heater 5 181 Living/dining room 7 a.m. 8 a.m. One 500 W & one 1,500 W wall heater 8 258 Living/dining room 8 a.m. 9 a.m. One 500 W & one 1,500 W wall heater 9 284 Living/dining room 9 a.m. 3 p.m. One 500 W & one 1,500 W wall heater 8 268 Living/dining room 3 p.m. 4 p.m. One 500 W & one 1,500 W wall heater 8 250 Living/dining room 4 p.m. 5 p.m. One 500 W & one 1,500 W wall heater 7 243 Living/dining room 5 p.m. 6 p.m. One 500 W & one 1,500 W wall heater 7 236 Living/dining room 6 p.m. 7 p.m. One 500 W & one 1,500 W wall heater 7 229 Living/dining room 7 p.m. 8 p.m. One 500 W & one 1,500 W wall heater 7 222 Living/dining room 8 p.m. 9 p.m. One 500 W & one 1,500 W wall heater 7 235 Living/dining room 9 p.m. 10 p.m. One 500 W & one 1,500 W wall heater 7 220 Living/dining room 10 p.m. 11 p.m. One 500 W & one 1,500 W wall heater 8 282 Living/dining room 11 p.m. 12 p.m. One 500 W & one 1,500 W wall heater 11 356 Living/dining room Wattage Totals 5,875

Water Use [Tot.Gal/hr] Hourly Energy Use [Wh] WH Baseline Performance LHA_Water Use [gal/hr] LHB_Water Use [gal/hr] LHA_Energy Use [Wh] LHB_Energy Use [Wh] 12 2000 1800 10 1600 8 1400 1200 6 1000 800 4 600 2 400 200 0 0 12:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 12:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 AM AM AM AM AM AM AM AM AM AM AM AM PM PM PM PM PM PM PM PM PM PM PM PM November 11, 2013 34

AM Peak Curtailment Unable to collect data due to internet connectivity issues and connection with GE servers Theoretical calculation yields: Experiment A.M. Peak Curtailment WH Mode Duration Average Power Draw Impact (W) Average Energy Impact during DR Event (W h) Average Daily Energy Impact (W h/day) HP 3 hours 515 1,545 N/A ER 3 hours 1,355 4,065 N/A

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] EVE Peak Curtailment Experiment WH Mode Duration Average Power Draw Impact (W) EVE Peak Curtailment Average Energy Impact during DR Event (W h) HP 3 hours 453 1,345 463 ER 3 hours 1,194 3,433 303 5000 4500 4000 3500 3000 Average Daily Energy Impact (W h/day) 2500 2000 1500 ERWH w DR HPWH w DR ERWH Baseline HPWH Baseline 1000 500 0 November 11, 2013 Time 36

1:00am 2:00am 3:00am 4:00am 5:00am 6:00am 7:00am 8:00am 9:00am 10:00am 11:00am 12:00pm 1:00pm 2:00pm 3:00pm 4:00pm 5:00pm 6:00pm 7:00pm 8:00pm 9:00pm 10:00pm 11:00pm Hot Water Delivery Temperature [F] EVE Peak Curtailment Tank Temperature 130 LHB_Out_WaterTemp LHA_Out_WaterTemp 125 120 115 110 105 100 95 90 85 80 Time November 11, 2013 37

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] PM INC Balancing Event 1800 1600 1400 1200 1000 800 600 ERWH w DR HPWH w DR ERWH Baseline HPWH Baseline 400 200 0 Time Experiment WH Mode Duration Average Power Draw Impact (W) Afternoon INC Balancing Event Average Energy Impact during DR Event (W h) HP 1 hour 351 351 218 ER 1 hour 908 908 15 Average Daily Energy Impact (W h/day)

1:00am 2:00am 3:00am 4:00am 5:00am 6:00am 7:00am 8:00am 9:00am 10:00am 11:00am 12:00pm 1:00pm 2:00pm 3:00pm 4:00pm 5:00pm 6:00pm 7:00pm 8:00pm 9:00pm 10:00pm 11:00pm PM INC Balancing Event Tank Temperature 130 LHB_Out_WaterTemp LHA_Out_WaterTemp 125 120 Temp. F 115 110 105 100 2 F decreased ERWH tank temperature 5 F decreased HPWH tank temperature 95 90 85 80 Time

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] INC Balancing Events 3000 Decreased power (W) AND energy (Wh) use commensurate with operating time AM, PM, and EVE all show expected performance No Late night INC Balance due to no load at that time Experiment Morning INC Balancing Event 2500 2000 1500 1000 500 0 WH Mode Duration Time Average Power Draw Impact (W) Average Energy Impact during DR Event (W h) HP 1 hour 532 532 216 ER 1 hour 1,464 1,464 118 ERWH w DR HPWH w DR ERWH Baseline HPWH Baseline Average Daily Energy Impact (W h/day) 40

1:00am 2:00am 3:00am 4:00am 5:00am 6:00am 7:00am 8:00am 9:00am 10:00am 11:00am 12:00pm 1:00pm 2:00pm 3:00pm 4:00pm 5:00pm 6:00pm 7:00pm 8:00pm 9:00pm 10:00pm 11:00pm Hot Water Delivery Temperature [F] INC Balancing Event Tank Temperature LHB_Out_WaterTemp LHA_Out_WaterTemp Reduced energy use in HPWH significant due to reduced tank temperature 130 125 120 115 110 105 100 2 F decreased ERWH tank temperature 10 F decreased HPWH tank temperature May not be experienced by most occupants 95 90 85 80 Time 41

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] EVE INC Balancing Event 2500 2000 1500 ERWH w DR 1000 HPWH w DR ERWH Baseline 500 HPWH Baseline 0 Experiment WH Mode Duration Average Power Draw Impact (W) Evening INC Balancing Event Time Average Energy Impact during DR Event (W h) HP 1 hour 445 445 42 ER 1 hour 1,182 1,182 155 Average Daily Energy Impact (W h/day)

1:00am 2:00am 3:00am 4:00am 5:00am 6:00am 7:00am 8:00am 9:00am 10:00am 11:00am 12:00pm 1:00pm 2:00pm 3:00pm 4:00pm 5:00pm 6:00pm 7:00pm 8:00pm 9:00pm 10:00pm 11:00pm Hot Water Delivery Temperature [F] EVE INC Balancing Event Tank Temperature 130 125 LHB_Out_WaterTemp LHA_Out_WaterTemp 120 115 110 105 100 5 F decreased HPWH tank temperature 95 90 85 80 Time

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] EVE DEC Balance Event Confounded by Coast and Rebound Effect 4500 4000 3500 Rebound from previous day s evening DEC balancing event 3000 2500 2000 1500 Diminished evening DEC balancing event ERWH w DR HPWH w DR ERWH Baseline HPWH Baseline 1000 500 Morning DEC balancing event, coast, and rebound 0 Time Experiment WH Mode Duration Average Power Draw Impact (W) Morning DEC Balancing Event Average Energy Impact during DR Event (W h) Average Daily Energy Impact (W h/day) HP 1 hour 98 98 347 787 787 ER 1 hour Unable to calculate (1,222*) (1,222*) * = data point is estimated based on theoretical calculation

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh]) Late Night DEC Balancing Event Both ERWH and HPWH effectively provide DEC balancing event in the late night hours 1800 1600 1400 1200 1000 800 600 400 200 ERWH w DR HPWH w DR ERWH Baseline HPWH Baseline 0 Time Experiment WH Mode Duration Average Power Draw Impact (W) Late Night DEC Balancing Event Average Energy Impact during DR Event (W h) Average Daily Energy Impact (W h/day) HP 1 hour 577 577 700 ER 1 hour 1,222* 1,222* Unable to calculate November 11, 2013 45 * = data point is estimated based on theoretical calculation

12:00 AM 1:00 AM 2:00 AM 3:00 AM 4:00 AM 5:00 AM 6:00 AM 7:00 AM 8:00 AM 9:00 AM 10:00 AM 11:00 AM 12:00 PM 1:00 PM 2:00 PM 3:00 PM 4:00 PM 5:00 PM 6:00 PM 7:00 PM 8:00 PM 9:00 PM 10:00 PM 11:00 PM Water Heater Energy Use [Wh] PM DEC Balancing Event 2500 2000 1500 1000 ERWH w DR HPWH w DR ERWH Baseline HPWH Baseline 500 0 Time Experiment WH Mode Duration Average Power Draw Impact (W) Afternoon DEC Balancing Average Energy Impact during DR Event (W h) Average Daily Energy Impact (W h/day) HP 1 hour 182 182 297 ER 1 hour 1,381* 1,381* 1,776* * = data point is estimated based on theoretical calculation

1:00am 2:00am 3:00am 4:00am 5:00am 6:00am 7:00am 8:00am 9:00am 10:00am 11:00am 12:00pm 1:00pm 2:00pm 3:00pm 4:00pm 5:00pm 6:00pm 7:00pm 8:00pm 9:00pm 10:00pm 11:00pm Hot Water Delivery Temperature [F] DEC Balancing Event Tank Temperature 140 LHB_Out_WaterTemp LHA_Out_WaterTemp 130 120 110 100 90 80 Time

Calculation of Theoretical Hourly Demand where: Q = energy in Wh Q = m C p T setpoint T o 0.293 Wh Btu m = mass of water in pounds = specific heat capacity of water (1 Btu lb ) C p T setpoint = the desired set point of the water heater tank in F T o = the initial temperature of the water (i.e., the previous tank set point) in F If there are draws during the hour, then use: Q = m tank C p T setpoint T o + m draw C p T setpoint T in 0.293 Wh Btu where: T in = the incoming water temperature in F and other variables are as described previously.

Calculation of Theoretical Number of HPWHs Required to Provide the Same DR Potential as a Single ERWH ERWH Power Use [W] HPWH Power Use [W] = 4,650 W 587 W = 7.9 8 HPWH/ERWH