Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

Similar documents
INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

ESSE Cooking Stove OPERATING & INSTALLATION INSTRUCTIONS MODEL: EW/EWB GUARANTEE INFORMATION FOR USE WHEN ORDERING SPARES: 01/06.

CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS

WOLVERTON STOVES U S E R M A N U A L S h A N d o N / A R d L E i g h

H E R A L D 8 0 B. Installation and Operating Instructions

Inset Chevin 20B. Installation and Operating Instructions. JINCHW09 Rev A 12/05/14

THE MUCH WENLOCK. Installation Instructions for Freestanding Much Wenlock Stove with Boiler

CHARNWOOD COUNTRY 6 FT

C O N S O R T 9. Installation and Operating Instructions

charnwood country 4MKII Operating & Installation Instructions

Stockton 7 & 8 Inset Convector Stove

Newton Multi Fuel 8kW Space Heating Stove With Boiler

Riva F40 Cube. Multi-Fuel Free Standing Stove. Installation Instructions. Models: RVF40C. For use in Great Britain and Eire IMPORTANT

H E R A L D 1 4 C E V. I I

Installation & Operating Instructions

Wet stove installation guide

charnwood Operating & Installation Instructions

Operation instructions

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

THE SEVERN. Installation Instructions for Freestanding Severn Stove with Boiler PERFORMANCE RATING

Firefox 12B (Boiler Model) CE V.11

Newton Multi Fuel 5kW Space Heating Stove

charnwood country 16b multi-fuel Operating & Installation Instructions

charnwood I S L A N D Operating & Installation Instructions

Firebird Smoke Exempt Inset Stove

charnwood Operating & Installation Instructions

Mendip 5 standard and pedestal stove Multi-Fuel, Wood, Smoke control model 4.8 kw / 5.2kW Space Heating Stove

TRH 45 MK4 SOLID FUEL ROOM HEATER USER AND INSTALLATION INSTRUCTIONS

TECHNICAL MANUAL. The Buxton. Multifuel Stove Model BX1MF. To be retained by the user for future reference

Course introduction 2. 1 Appliances and fuels 3. 2 Combustion Legislation Air supply Flues and chimneys Commissioning 83

charnwood Operating & Installation Instructions

INSTALLATION AND OPERATION MANUAL

Ludlow Wood Burning Smoke Exempt Stove

WARNING This information is a copy of an original archive, therefore Aga cannot be held responsible for its continued accuracy.

charnwood Operating & Installation Instructions

Ironheart Models EW & EWB

THE MUCH WENLOCK. Operating Instructions for Freestanding Much Wenlock Stove with Boiler

Website:

TECHNICAL MANUAL. Multifuel Stove Model MV1MF. To be retained by the user for future reference

Ludlow Non-Boiler (Multi-Fuel)

charnwood Operating & Installation Instructions

stove Tested to EN BROSELEY CO Alarms: as the

CE EN13240 ENJOY YOUR STOVE SAFELY. Multifuel Cast Iron Stove INSTRUCTION MANUAL

Installation Instructions. Rayburn 300W Wood Burning Cooker

Inset Telford 8. Multi-Fuel Inset Stove Installation and Operating Instructions. JINTDI08 Rev C 21/05/14

Shawbury Wood Stove. (Smoke Exempt)

Yeoman CL. High Output Boiler Stove YM-CL8HB. Instructions for Use, Installation and Servicing

charnwood Operating & Installation Instructions

Installation & Operating Instructions

Little Wenlock Classic

charnwood SLX45MKII MULTI-FUEL Operating & Installation Instructions

VEGA 100 CLEAN BURN II INSTALLATION AND OPERATING INSTRUCTIONS (to be left with the householder)

Stockton. Clean-burn stove. MODELS: 3 MF/4 Wood/4 MF/5 MF. Installation and Operating Instructions. For Use in Great Britain and Eire

OIL FIRED COOKERS & BOILERS

PANAMERA STOVE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS AND USE ONLY THE RECOMMENDED FUELS

Oscar Solid Fuel Stove

Lismore Boiler Solid Fuel Stove

Henley Druid 21kW. Boiler Stove Installation and Operating Instructions. Important: This product must be installed by a suitably qualified installer.

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

Dovre 250 Free Standing Stove - including Smoke Control Version

FIONN SOLID FUEL BURNING STOVE INSTALLATION AND OPERATING INSTRUCTIONS

Hanwood Wood Stove. (Smoke Exempt)

Troubleshooting Guide

FM5 Freestanding Multifuel Dry Stove

Solis Inset 500 & 900

Dorrington Wood Stove

GB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE

SAVONA STOVE INSTRUCTIONS PLEASE READ THESE INSTRUCTIONS AND USE ONLY THE RECOMMENDED FUELS

High Output Boiler Stoves

Solis Inset 500 & 900

Stockton 7 & 8. Inset Convector Stove MODELS: 7125/7126. Instructions for Use, Installation and Servicing

Huntingdon

Aresta, Limit & Firepoint

Westbury Wood Stove. (Smoke Exempt)

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

Huntingdon

HEAT YOUR HOME SAFELY

High Output Boiler Stoves

Riva Studio Duplex. Inset Convector Cassette. Instructions for Use, Installation & Servicing

THE SEVERN. Operating Instructions for Freestanding Severn Stove with Boiler

Neo. Multifuel Stove Model Neo 1 / Neo 3. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Stockton 7 Inset. High Output Boiler Inset. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Regency. Free Standing Stove. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

BERRINGTON SOLID FUEL BOILER STOVE

Dovre 250 Cast Iron Gas Stove

Free Standing Stove. Technical Manual. 8 Series. User and Installation Instructions. For use in GB & IE (Great Britain and Republic of Ireland).

Novus. Multifuel Stove Model Novus. To be retained by the user for future reference. Thank you for purchasing an ACR Heat Products stove

High Output Boiler Stove

Stockton. High Output Boiler Stoves. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Stockton. High Output Boiler Stoves. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Commissioning of Heat Producing Appliances Burning Solid Fuel

Oxford 5. Operation and Installation Manual. Version A 21/06/2017 (MZSOX5SMB) IMPORTANT

Instructions for Use, Installation & Servicing

STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE

Lismore Non Boiler Solid Fuel Stove

Riva Studio Dedicated Sealed External Air Kit

Ardmore Non Boiler Solid Fuel Stove

Yeoman CL. Free Standing Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Cara+ Solid Fuel High Output Boiler. Insert Stove

Transcription:

Esse 700 27B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL Esse Stoves & Cookers Long Ing. Barnoldswick, Lancashire BB18 6BN. United Kingdom. Tel: + 44 (0) 1282 813235 F: + 44 (0) 1282 816876 enquiries@esse.com www.esse.com 1

INSTALLATION & OPERATING INSTRUCTIONS FOR THE ESSE 700 27B MODEL U.K. & Ireland READ THESE INSTRUCTIONS AND SAVE FOR REFERENCE Contents Safety Notes Page 3 Page 4 INSTALLATION INSTRUCTIONS Chimney and Flue Page 4 Flue and Draught Measurement Flue Diagnosis Flue Stabiliser Page 5 Page 6 Page 7 Installing the stove Page 7 Positioning page 7 Hearth Page 7 Flue connection Page 8 Important installation notes Page 8 Positioning internal components Page 8,9,10 Stove outputs Page 11 The domestic and central heating system Page 11 Final Checks Page 12 Boiler Tapping Page 12 OPERATING INSTRUCTIONS Page 14 Wood Lighting and controlling the fire Correct running temperatures for wood burning Extended burning Types of wood for fuel Stove Guarantee 2 Page Page Page Page Page Page 15 15 17 17 17 19

SAFETY NOTES Properly installed, operated and maintained, this appliance will not emit fumes into the dwelling. However occasional fumes from de-ashing and refuelling may occur. Persistent fume emission is potentially dangerous and must not be tolerated. If fume emission does persist, open doors and windows to ventilate the room. Let the fire burn out or eject and safely dispose of fuel from the appliance. Once the fire is cold, check the flue and chimney for blockages and clean if required. Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected. Seek expert advice if necessary. Do not fit an extractor fan in the same room as the appliance. An adequate air supply for combustion and ventilation is essential. Air openings provided for this purpose must not be restricted. This appliance requires an air supply of 100 square cm.(16 Square Inches) in order to provide an adequate amount of air for successful combustion. It is important that flue ways are cleaned frequently and the chimney swept regularly. Also the stove must be maintained in good mechanical order. Regular sweeping will mean at least once per year. If the chimney was previously used for an open fire, it is possible that the higher flue gas temperatures generated by the stove may loosen deposits that were firmly adhering to the inner surface of the chimney and cause blockage of the fluepipe. We recommend that in such a situation a second sweeping of the chimney should be carried out within one month of regular use of the stove after installation. Also, lock or remove any existing dampers in the flueway. Should it be likely that children, aged or infirm people approach the fire, then a fireguard should be fitted. Avoid the use of aerosol sprays in the vicinity of the stove when it is in operation. 3

Installation Instructions The installer has a responsibility under the Health and Safety at Work Act 1974 to provide for the safety of persons carrying out the installation. Attention is drawn to the fact that fire cement is caustic and hands must be washed thoroughly after use. The appliance is heavy and care must be taken during handling. Although the appliance does not contain asbestos products, it is possible that asbestos may be disturbed in existing installations and every precaution must be taken.please Observe The Above. These instructions give a guide for the installation of the appliance but in no way absolves the installer from responsibilities to confirm to British Standards, in particular BS8303 and BS6461, relating to the installation of solid fuel appliances. The installation should also comply with local Building Regulations and Local Authority Bye-Laws. The stove must be placed at least 40cm away from any combustible materials. If necessary, any adjoining walls should be protected from the effects of heat. Chimney and Flue The successful operation of this stove relies on the adequate performance of the chimney to which it is connected. The chimney must: Have an internal cross section of no less than 320 cm.sq (200mm Dia.). (If a flue liner is used it should be 6" diameter for the 700 17B stove, and suitable for wood burning). Be a minimum 4.6m high from hearth level to pot. Be terminated at least 1m above roof level so that the chimney does not terminate in a pressure zone. See Figure.1 Be free from cracks, severe bends, voids, and obstructions. Be connected to the one appliance only. New chimneys must be built in accordance with local building regulations. Existing chimneys must be tested in accordance with HETAS requirements. If the stove is installed as a free-standing appliance, it should not support any part of the chimney. Voids in the chimney should be avoided, as these will prevent a steady flue draught. The stove flue pipe should pass beyond the narrowing of the chimney. See Figure 2 Consideration should be given to falling soot. For rear outlet stoves it may be necessary to provide a soot catchment area in the flue pipe so that soot does not settle in the path of the flue gases. A flue/chimney access point may also be required so that the state of the chimney can be checked and any fallen soot removed. External flues must be insulated to prevent heat loss. 4

Fig: 1- Chimney and flue performance. Fig: 2-Top flue installation only 700 17B model. Flue Liner Insulation Flue Access Flue Draught Measurement The chimney can be checked, before the stove is installed, with a smoke match. If the chimney doesn t pull the smoke it may suggest the chimney needs attention (see the Flue Diagnosis Table below). Note: This test is only a guide as an apparently poor flue may improve once the stove is installed, lit and the flue is warmed. If, once the stove is installed, there is any doubt that the chimney is providing an adequate draught, a flue draught 5

reading can be taken with the stove lit. Two flue draught readings should be taken, one with the stove at minimum firing rate and one at maximum firing rate. Measurement The flue draught test hole must be drilled in the flue pipe as close to the stove as possible and before any flue draught stabiliser. Minimum The stove should be lit and allowed to warm the flue thoroughly. The air controls can then be set so that the stove burns on a low setting. Allow the burning rate to become steady. The flue draught reading should now be taken with the thermostatic air intake closed and the airwash control fully open. Maximum The thermostatic air intake can now be opened to allow the stove to burn at maximum rate. Give the stove some time for the burning rate to become steady, make sure the airwash control is fully open and take a flue draught reading immediately. Ideally, the flue draught readings should range between 1mm wg and 2.5mm wg. Any readings significantly outside this range may indicate the need for remedial action. If the draught reading is excessive then a draught stabiliser should be fitted to achieve better fuel burning rates. Lack of draught or downdraught should be avoided for satisfactory performance Flue Diagnosis Fig 3: Chimney conditions. 6

Flue Stabilizer A flue stabilizer can be fitted to reduce the draught through the stove if the flue draught is too high. The flue stabilizer should be; fitted in the same room as the stove, the same size as the flue pipe, and fitted no closer than 700mm to the flue outlet of the appliance. Installing the stove Fig: 4 Clearances from combustibles Clearances in mm Side 400 Rear 400 Top 450 Front 305 Positioning Figure 4 shows recommended distances between the stove and surrounding combustible materials. As a rule, any surrounding combustible material should not exceed 80 C. There should be sufficient space around the stove for service work. Hearth The construction of the hearth must conform to Building Regulations, must be firm, non-combustible and capable of supporting the stove. The hearth must be fire proof to at least 50 degrees Centigrade. Relevant Building Regulations relating to hearth should be observed. The minimum hearth thickness is 13mm. Over The Stove 7

When a Wooden mantle is intended to be installed, at least 18-24 (460-600mm) clearance is required to the stove. It may also be required to fit heat shields in relevant areas. Flue connection 700-17B model Stove The flue pipe used to connect the stove to the chimney is 6"(150mm) diameter. The stove is supplied ready for top flue connection complete with a 5-6 adaptor. Figure 2 (left hand side illustration only) shows a suitable flue connection. Important installation notes: 1. The installation must allow for adequate chimney sweeping. 2. Avoid using bends greater than 45 to the vertical. All pipe flue sections should be as close to vertical as possible. 3. All joints in the flue system must be effectively sealed. 4. All flue sockets must face upwards. On completing the installation, check that all the internal components of the stove are positioned correctly: Check - ash pan, steel plate, cast grate, perforated sides and back, side/back bricks vermiculite and metal, front bar, secondary air tube & clip. View of firebox 8

Perforated sides and back Vermiculite/metal side front Vermiculite/metal side rear Ashpan Steel plate Cast plate Front Bar Operating Tool Secondary Air Tube Boiler 9

Boiler Boiler Fig 5 DOOR LOCKING CATCH BOTTOMGRATE ASHPAN Open Fig: 6 - Secondary air control 700 17B model Stove Stove Outputs The maximum Output of the 700 17B Model is 8.0 kw (27,296 Btu/h) to water and 9.0kW (30.700 Btu/h) to the room. The figures are based upon burning 5.0Kg of wood/hour with all controls open and doors closed. The minimum output 10

is 3.75Kw (12,800Btu s/h) to water with all controls closed using the same fuel load. The water capacity of the boiler is 7.1 litres. The Domestic and Central Heating System The domestic and central heating system must comply with BS:5449 Part 1. When fitting a joint central heating & domestic hot water system, it must be a double feed indirect hot water system storage type incorporating rust inhibitor to prevent corrosion & scale( normally gravity primary & pumped domestic) A distance of 50 feet in height between the flow tapping and the header tank is the maximum permissible. The system should include a heat link radiator to dissipate excess domestic hot water when required. Also an injector tee should be fitted to promote an adequate supply of domestic return water, when the heating system is in operation. The Boiler Tappings are 1 diameter BSP and should be connected so the primary flow and return pipes rise continuously to the open vent. In order to promote a warm return water temperature a pipe thermostat should be fitted on the domestic return and set at 45 degrees centigrade. Other controls such as a pump programmer, room & radiator thermostats can all be utilised without affecting the appliance thermostatic air control. Important. A warm return water temperature to the boiler is essential when burning wood to avoid the build up tar/resin & condensate forming on the boiler surfaces and firebox. A suitable pipe thermostat or other means should be attached to control the temperature of the return water. Failure to observe this warning could result in cooler water temperatures and extensive boiler damage as well as negating your stove guarantee. Final Checks After the system has been filled with water, light the appliance and check that all combustion products are being taken from the appliance and exhausted up the 11

chimney. The water flow rate should be adjusted to suit the circuit and the whole system balanced properly. Boiler Tapping Information. 530 150 270 360 Ouzledale Foundry Co Ltd, Long ing, Barnoldswick, Lancashire BB18 6BN England Http: //www.esse.co.uk 05/07 12