Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Similar documents
Commercial Tankless Rack System

Commercial Tankless Rack System

Commercial Tankless Rack System

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Commercial Tankless Rack System

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Tankless Condensing High Efficiency Water Heaters

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Residential/Commercial Gas Condensing Tankless Models

Residential Gas Tankless Water Heater

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Commercial Tankless Rack System

Commercial Tankless Rack System

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

Tankless Water Heaters

C1210ES Tankless Water Heater

C1050ES Tankless Water Heater

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

The WCGH High Efficiency Commercial Water Heater with Storage Tank

940ES Tankless Water Heater

940ES Tankless Water Heater

iq251, Gen II Submittal Data

TANKLESS PRODUCT GUIDE

TANKLESS PRODUCT GUIDE

10 : 1 Turndown Ratio

Residential & Commercial

DI/RO GAS TANKLESS WATER HEATER

RG7D 1-Stage Heat Series

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features.

iq1001, Gen II Submittal Data

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

Crossover. Hybrid Water Heater HIGH EFFICIENCY. Advanced Heating & Hot Water Systems. w w w.htproducts.com

C1210ESC Tankless Water Heater

NPE-A and NPE-S Condensing Tankless Water Heaters

NPE-A and NPE-S Condensing Tankless Water Heaters

NPE-A and NPE-S Condensing Tankless Water Heaters

Commercial Gas Water Heaters

MECHANICAL VENTING VERSATILITY

Automatic Circulating Water Heaters

Commercial Water Heating System (CWHS)

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Crossover. Hybrid Water Heater. High Efficiency. Advanced Heating & Hot Water Systems.

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com


i200, Gen II i250, Gen II Submittal Data

NHB High Efficiency Condensing Boilers

NPE-A and NPE-S Condensing Tankless Water Heaters

Date: Project #: Engineer: Prepared By: Bid Date:

DEMAND DUO 80-GALLON HYBRID WATER HEATING SYSTEM SUBMITTAL SHEET

GB Condensing Gas Boiler

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

Suggested Specifications Prestige Excellence 110

Boilers Variable Fire Boilers

TANKLESS WATER HEATER HEATING SOLUTIONS

Commercial Gas Water Heaters

Tankless Water Heaters

FINNED WATER-TUBE POOL HEATERS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

EEMAX-Eemax Electric Water Heaters RW List Prices - Page T-37

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

GB Condensing Gas Boiler

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

iq751/iq1001/iq1501 Specifications (Floor-standing units)

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Commercial Gas Water Heaters

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

DIVISION FINNED WATER-TUBE WATER HEATERS

Utica Boilers MAC Submittal

Bosch Greentherm Series

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions

Infi niti Tankless. Water Heater Series Featuring SRT (Scale Reduction Technology) Built to be the Best

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

G6RC Series TECHNICAL SPECIFICATIONS

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

advanced : technology

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

AM Rapid Recovery Water Heaters

TABLE OF CONTENTS BRADFORD WHITE BOILERS

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

940ESO Tankless Water Heater

WATER-TUBE POOL HEATERS

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Product Brochure Water Heaters Tankless Gas WELC ME TO CONTINUOUS HOT WATER. Indoor and Outdoor Tankless Gas Water Heaters. Rheem.

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

Gas-Fired Condensing Boilers A Green Start to Space & Water Heating

Warmth, efficiency, and total peace of mind.

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

Technology and design with Comfort and Energy Saving in mind. Instantaneous Gas Water Heater Series

FINNED WATER-TUBE POOL HEATERS

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Transcription:

TANKLESS WALL MOUNT LIGHTWEIGHT Constructed of anodized aluminum frame Utilizes the industry s lightest 199,000 BTU/h high efficiency condensing tankless heater EXPANDABLE Multiple design and installation configurations Up to 597,000 BTU/h on a single rack system Able to link up to 20 heaters together with multi-link system REDUNDANCY Multiple combustion systems provide peace of mind Easily isolate a unit for maintenance which extends the life of the heaters EASY FIELD INSTALLATION Reduce installation costs with three simple connections (cold water, hot water and gas) EASILY INTEGRATE STORAGE WARRANTY 6 year limited heat exchanger 5 year limited tankless parts 1 year limited rack parts September 2017 Takagi Takagi.com Page 1 of 5

MODEL NUMBER NUMBER OF CONFIGURATIONS HEATERS FUEL TYPE GAS CONSUMPTION INPUT MINIMUM MAXIMUM BTU/H BTU/H MODEL NUMBER GAS MANIFOLD CONNECTION HOT/COLD WATER MANIFOLD CONNECTIONS POWER Indoor Models TCI-CRS-22WM-N 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 4.5 A TCI-CRS-22WM-P 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 4.5 A TCI-CRS-23WM-N 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 6.75 A TCI-CRS-23WM-P 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 6.75 A TCI-CRS-33WM-N 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 9 A TCI-CRS-33WM-P 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 9 A TCO-CRS-22WM-N 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 4.5 A TCO-CRS-22WM-P 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 4.5 A TCO-CRS-23WM-N 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 6.75 A TCO-CRS-23WM-P 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 6.75 A TCO-CRS-33WM-N 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 9 A TCO-CRS-33WM-P 1-1/2" Schedule 40 pipe 2" Copper tube 120 V, 60 Hz, 9 A DIMENSIONS IN INCHES SHIPPING DIMENSIONS IN INCHES APPROX. MODEL NUMBER A B C SHIPPING LENGTH WIDTH HEIGHT LENGTH WIDTH HEIGHT WEIGHT (LBS) TCI-CRS-22WM-N 46 13.02 57 77 26.25 70 240 TCI-CRS-22WM-P 46 13.02 57 77 26.25 70 240 TCI-CRS-23WM-N 66 13.02 57 77 26.25 70 250 TCI-CRS-23WM-P 66 13.02 57 77 26.25 70 250 TCI-CRS-33WM-N 66 13.02 57 77 26.25 70 350 TCI-CRS-33WM-P 66 13.02 57 77 26.25 70 350 TCO-CRS-22WM-N 46 13.02 57 77 26.25 70 240 TCO-CRS-22WM-P 46 13.02 57 77 26.25 70 240 TCO-CRS-23WM-N 66 13.02 57 77 26.25 70 250 TCO-CRS-23WM-P 66 13.02 57 77 26.25 70 250 TCO-CRS-33WM-N 66 13.02 57 77 26.25 70 350 TCO-CRS-33WM-P 66 13.02 57 77 26.25 70 350 * Line drawings on pages 3 and 4. Model numbers- First number 2/3 = number of tankless units mounted. Model numbers - Second number 2/3 = rack size (max units that could fit on that rack). MAX FLOW (GPM) 50 F RISE 60 F RISE 70 F RISE 80 F RISE 90 F RISE 100 F RISE Indoor Models TCI-CRS-22WM-N 2 Natural 15,000 398,000 15.2 12.6 10.8 9.4 8.4 7.6 TCI-CRS-22WM-P 2 Propane 13,000 398,000 15.2 12.6 10.8 9.4 8.4 7.6 TCI-CRS-23WM-N 2 Natural 15,000 398,000 15.2 12.6 10.8 9.4 8.4 7.6 TCI-CRS-23WM-P 2 Propane 13,000 398,000 15.2 12.6 10.8 9.4 8.4 7.6 TCI-CRS-33WM-N 3 Natural 15,000 597,000 22.8 18.9 16.2 14.1 12.6 11.4 TCI-CRS-33WM-P 3 Propane 13,000 597,000 22.8 18.9 16.2 14.1 12.6 11.4 TCO-CRS-22WM-N 2 Natural 15,000 398,000 15.2 12.6 10.8 9.4 8.4 7.6 TCO-CRS-22WM-P 2 Propane 13,000 398,000 15.2 12.6 10.8 9.4 8.4 7.6 TCO-CRS-23WM-N 2 Natural 15,000 398,000 15.2 12.6 10.8 9.4 8.4 7.6 TCO-CRS-23WM-P 2 Propane 13,000 398,000 15.2 12.6 10.8 9.4 8.4 7.6 TCO-CRS-33WM-N 3 Natural 15,000 597,000 22.8 18.9 16.2 14.1 12.6 11.4 TCO-CRS-33WM-P 3 Propane 13,000 597,000 22.8 18.9 16.2 14.1 12.6 11.4 Page 2 of 5

2 UNIT WALL MOUNT Pipe Lengths: (INLETS) SEE NOTE 1. (EXHAUSTS) 42.00 in. 57.00 in. Front Back 13.02 in. NOTES: 1. TOP-MOUNTED AIR SUPPLY INLET/EXHAUST VENTS ARE USED WITH INDOOR MODELS ONLY. 2. MOUNTING BRACKETS ADJUST HORIZONTALLY ALONG CHANNEL SLOTS. 3. INDOOR AND OUTDOOR RACK SYSTEMS HAVE IDENTICAL DIMENSIONS. EXCEPTION: INDOOR MODELS HAVE TOP-MOUNTED INTAKES AND EXHAUSTS. OUTDOOR MODELS DO NOT. *Fittings to be field supplied Page 3 of 5

3 UNIT WALL MOUNT (ALL INLETS) Pipe Lengths: SEE NOTE 1. (ALL EXHAUSTS) 62.81 in. 57.00 in. Front Back 13.02 in. NOTES: 1. TOP-MOUNTED AIR SUPPLY INLET/EXHAUST VENTS ARE USED WITH INDOOR MODELS ONLY. 2. MOUNTING BRACKETS ADJUST HORIZONTALLY ALONG CHANNEL SLOTS. 3. INDOOR AND OUTDOOR RACK SYSTEMS HAVE IDENTICAL DIMENSIONS. EXCEPTION: INDOOR MODELS HAVE TOP-MOUNTED INTAKES AND EXHAUSTS. OUTDOOR MODELS DO NOT. *Fittings to be field supplied Page 4 of 5

TANKLESS COMMERCIAL RACK SYSTEMS The Tankless Commercial model # shall be factory assembled pre-plumbed system and includes Takagi CT-199 Condensing Tankless Water Heaters. The Commercial shall include 2 inch copper water supply lines, 2 foot long ¾ inch flexible stainless steel water lines to the heaters, 1 ½ inch schedule 40 gas supply pipe with 3 foot long ¾ inch CSST flexible gas lines to the heaters, and isolation valves with 150 psi pressure relief valves for each heater. The rack shall be assembled as a wall mount design. The fully modulating, on-demand, condensing gas fired tankless water heater(s) shall be Takagi Tankless Water Heater model CT-199, having a maximum input rating of 199,000 Btu/h and available in NG or LP. The heater shall have ¾ in. male NPT water and gas connections. The inlet gas supply pressures shall be 4.0 in. WC (min.) up to 10.5 in. WC (max.) for NG and 8.0 in. WC (min.) up to 14 in. WC (max.) for LP. The indoor heater(s) shall incorporate an integrated temperature controller that will provide diagnostic information, fault history, and heater set temperature. The outdoor heater(s) shall be factory supplied with a temperature remote, 100112572, that can be installed up to 400 ft. from the heater using 20 gauge (minimum) control wire. The temperature remote shall provide diagnostic information, fault history, and additional set temperatures. The heater(s) shall operate using 120 V / 60 Hz power source. The indoor heater(s) will incorporate a factory installed power cord. The indoor heater(s) shall be vented with 3 or 4 diameter schedule 40 PVC, CPVC, ABS, or Category IV vent pipe with a length not to exceed 70 ft. (equivalent) for 3 vent or 100 ft. (equivalent) for 4 vent, terminating horizontally or vertically. The intake pipe may use material such as PVC, ABS, aluminum, or Category IV pipe and cannot exceed 70 ft. (equivalent) for 3 vent or 100 ft. (equivalent) for 4 vent. The indoor heaters shall be able to be common vented with schedule 40 PVC pipe with a length not exceed 100 ft. (equivalent) using up to10 inch pipe. Proper sizing is provided in the heater s installation manual. The outdoor heater(s) shall be constructed with an integral exhaust vent on the front of the heater. The water heater(s) shall use a commercial grade copper, fin tube primary heat exchanger with quick release brass or bronze waterways. The secondary heat exchanger shall be constructed from stainless steel 316L. The heater(s) shall be controlled by an onboard solid-state printed circuit board which uses the following factory installed components: thermistors to monitor water temperature and exhaust temperature; a flow sensor to measure flow rate; a flame sensor to monitor combustion; an air-fuel ratio rod to measure and adjust air inputs in order to maintain optimal combustion efficiency. The heater also consists of inline fusing and surge absorbers for electrical surge protection, an electronic spark igniter, aluminized stainless steel burners, hi-limit temperature switches to monitor water and exhaust temperatures, modulating gas valve, dual freeze protection that will automatically fire the heater (indoor model only) and use heating blocks to protect the heat exchanger, and an overheat cutoff fuse. The heaters can manifold to Easy-Link up to 4 heaters to provide additional capacity. The Easy-Link controls shall be built onto the onboard solid-state printed circuit board and does not require external controls. The linking control wire shall be supplied with the heater. The heaters can use a Multi-Unit controller, 100112691, to manifold 5-20 heaters. The Easy-Link and Multi-Unit Controller shall modulate the system for the most efficient performance. The Easy-Link and Multi-Unit Controller shall rotate the priority heater every 12 hours of operation time or 100 starts for balanced duty/cycle operation. The heater models are design certified by CSA according to ANSI Z21.10.3 CSA 4.3, approved for sale in the United States, ENERGY STAR qualified, has a minimum uniform energy factor of 0.93, meets the energy efficiency requirements of the U. S. Department of Energy and ASHRAE 90.1, complies with SCAQMD Rule 1146.2 and other air quality districts with similar requirements for low NOx emissions of 14 ng/j or 20 ppm, and shall be certified to NSF 5 Standards. September 2017 Takagi Takagi.com Page 5 of 5