A Product of Southern Steel Pipe Sdn. Bhd. The Coloured. Smartube, Your Smarter Choice!

Similar documents
Steel Fire Sprinkler Pipe

EN transition from BS 1387 Structural & Conveyance Business

Hundreds of Satisfied Customers...

1 of 7 UNIVERSAL FIRE ENGINEERING (ALOR SETAR) SDN BHD. EN3 Water & Foam Type Fire Extinguisher. Portable Carbon Dioxide Fire Extinguisher

SCESm Directory Accreditation number: SCESm 0003

2015 DEPARTMENT OF STANDARDS MALAYSIA

PRODUCT SPECIFICATION FireMaster Plus

TECHNICAL REPORT IEC TR Optical fibre cables Guidelines to the installation of optical fibre cables. colour inside. Edition 2.

Q TRADING UPDATE. May 5, Copyright Bureau Veritas / May 5, 2015 / p 1

Di-440 The Modular Analyser

Company Name:- Dominant Opto Technologies Sdn. Bhd. Company Interest:- Contract Manufacturing and Sales of LED Product

ADVANCED TECHNOLOGY, FLEXIBILITY, AND BUILT-IN SURVIVABILITY

TRIMOTERM TECHNICAL SPECIFICATION


INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNAL FRAMING PROFILES

MERIT Series R-410A - Upflow / Horizontal

OLF-5-TAK Tank connection kit 2.0

MERIT Series R-410A - Upflow / Horizontal

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

INTERNATIONAL STANDARD

HRS035-MS-022-RD 22 (559mm) 19mm x 30m 310mm Fixed Manual. HRS037-GI-019-RD 19 (483mm) 19mm x 36m 350mm Swing Manual

Global Pressure Sensitive Adhesives Market Study ( )

Topscan G3 Presence detector for automatic doors

Life Safety Support Products

INTERNATIONAL STANDARD

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

850 and 830 Series. Generation 6

INTERNATIONAL STANDARD

SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD.

Extrusion Moulding Solut. Press Kit. All press enquiries should be directed to: Sue Davenport Marketing Director

C22 Bulletin # October 1993 Supersedes May 1993

PRE-QUALIFICATION. DoTEC CO., LTD.

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

BRISTOL: A History & Future.

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35


Pneumatic Tubing POLYTUBING O.D. 5/32"

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

KUTERLEX & KUTERLEX PLUS PLASTIC COATED COPPER TUBE

Introducing Inverted SMT Thru Board Connector

INTERNATIONAL STANDARD

Sprinkler Guards and Water Shields Model C Model D Model E

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

UPDATE SESSION : TESTING SERVICES. Presented By: Puan Hjh Nur Fadhilah Muhammad Senior General Manager Testing Services Department

This is a preview - click here to buy the full publication

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

WIKA Instrumentation (M) Sdn Bhd. Safe and Uncompromising. Easy Testing within the Process - Testing and Calibration Technology.

Current Involvements:

INTERNATIONAL STANDARD

1 of 8. Unimech International Sdn. Bhd. Boiler Tubes Cleaning Tools. Electric Steam Boiler (50kg/hr kg/hr)

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

How Green Contractors Can Go

850 and 830 Series. Fire Detectors - Generation 6

Altman Lighting Spectra Cyc UV 50 Specification

INTERNATIONAL STANDARD

Acoustical tee. Acoustical Tee

Specsavers Case Study A standards solution for a global network of locally run businesses

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

Technical Information

830 Series. Fire Detectors - Generation 6

Sizes. Colors. Features

INTERNATIONAL STANDARD

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

Y Series. Panic Exit Device. An ASSA ABLOY Group brand

VIBRA-series: VIBRA, VIBRA +

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

Introducing Low Voltage DC Grid Interconnects

TECHNICAL REPORT IEC/TR Fibre optic communication system design guides Part 11: Multimode launch conditions. Edition 1.

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Building Services Brochure

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

Stainless Steel Door Furniture

PRODUCT SPECIFICATION FireMaster Plus Concertina

1 of 6 ALLEN GWYNNES PUMPS SDN BHD. AGL 150 Pump (Hydrocyclone Pumps) AGP/AGL Catalog ALLEN GWYNNES

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL STANDARD

JOB THERMO BULBS PRODUCT RANGE

Prospects and Opportunities for the Dutch Fire Safety Sector in Bangladesh

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

one stop HVACR OEM MANUFACTURER PROJECT REFERENCE

Snifter. User Manual. Distributor

Urbanscape Landscaping Solutions

INTERNATIONAL STANDARD

Kyoritsu Electric Group About our Business. (C)2015 Kyoritsu Electric Corporation., All Rights Reserved. 1

1 of 12. Spring Delights Sdn. Bhd. K HIGH PRESSURE WASHER K HIGH PRESSURE WASHER

INTERNATIONAL STANDARD

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

Clipsal Integrated Systems International Representatives China Head Office Greece Hong Kong South Africa Offices in all States Taiwan NSW VIC

Transcription:

A Product of Southern Steel Pipe Sdn. Bhd. The Coloured GALVANISED STEEL Conduit TUBE Smartube, Your Smarter Choice!

Leading the Steel Pipe Industry ISO 9001:2000 Certificate from Bureau Veritas A member of the Southern Steel Group of Companies, a leading steel mill in the region, SOUTHERN STEEL PIPE SDN.BHD. can trace its roots back to 1967 with the establishment of its parent company Southern Pipe Industry (Malaysia) Sdn. Bhd. which was founded as a joint-venture between Malaysia and Japan. Today, the pipe group consists of two steel pipe factories in Malaysia, with a combine annual sales revenue of over USD100 million and an annual capacity that exceeds 200,000mt. The many certifications garnered through the years are testament to the companies steadfast commitment in providing only the best products & services. Among others, it has the distinction of being the first steel mill in the country to be awarded the ISO 9001:2000 certification. The group s product lines were being exported to countries all over the world. ISO 9001:2000 Certificate from SIRIM QAS EMT Certificate from UL

certificates IMC Certificate from UL EMT Certificate from UL for Canada EMT Certificate from UL IMC Certificate from UL BS 31:1940 Certificate from SIRIM QAS BS 31:1940 Certificate from SIRIM QAS

Smartube Conduit ( In-line hot-dip galvanized conduit ) Utilising the latest, state-of-the-art in-line hot-dip galvanizing process, Smartube offer top notch galvanised and coloured finishes. Smartube is easy to bend simultaneously providing a smooth wire-pulling feature. Features (1) Easy wire pushing and pulling The slip coat on the inside wall makes wire-pulling easy, and protects against damages. (2) Advantages of colour conduits Saves time High quality finishing Save cost Cross-sectional view of SMARTUBE CONDUIT Protective polymer coat (red, orange, white colours, and clear are available) In-line hot-dip galvanized coating Steel Slip coat

colours Colour Options & Applications for Smartube Conduit (In-line hot-dip galvanized conduit) Smartube Red Fire alarm & security system Smartube Orange Lighting & fibre optic system General system for machineries Smartube White Blends well in light coloured areas PA System & IT System Smartube Clear Standard for conventional applications Standard & SPECIFICATIONS Smartube conduit is manufactured conforming to the following standards: UL 797 (EMT) UL 1242 (IMC) BS 31 BS 4568

EMT - ELECTRICAL METALLIC TUBING UL Listed File No. E313230 Trade Size Designator Outside Diameter Wall Thickness Unit Length Weight Wt. Per 100 Ft. (30.5M) Primary Quantity In in. mm in. mm in. mm m ft kg/pc lb. kg. Pcs Pcs Master ½ 16 0.706 17.9 0.042 1.07 3.050 10 1.46 32.19 14.60 10 700 ¾ 21 0.922 23.4 0.049 1.25 3.050 10 2.21 48.72 22.10 10 500 1 27 1.163 29.5 0.057 1.45 3.050 10 3.08 67.90 30.80 10 300 1-1/4 35 1.510 38.4 0.065 1.65 3.050 10 4.74 104.50 47.40 5 200 1-1/2 41 1.740 44.2 0.065 1.65 3.050 10 5.49 121.03 54.90 5 150 2 53 2.197 55.8 0.065 1.65 3.050 10 6.99 154.10 69.90 3 120 2-1/2 63 2.875 73.0 0.072 1.83 3.050 10 10.16 223.99 101.60 61 Remarks: Trade size 1-1/2 (41mm) through 2-1/2 (63mm) pending UL approval. IMC - INTERMEDIATE METAL CONDUIT UL Listed File No. E255245 Trade Size Designator Outside Diameter Minimum Wall Thickness Length Without Coupling Weight Wt. Per 100 Ft. (30.5M) Quantity In Primary in. mm in. mm in. mm m ft and in. kg/pc lb. kg. Pcs Pcs ½ 16 0.815 20.7 0.070 1.79 3.030 9 11-1/4 2.81 62.00 28.10 10 350 ¾ 21 1.029 26.1 0.075 1.90 3.030 9 11-1/4 3.81 84.00 38.10 10 250 Master 1 27 1.290 32.8 0.085 2.16 3.025 9 11 5.40 119.00 54.00 10 170 1-1/4 35 1.638 41.6 0.085 2.16 3.025 9 11 7.17 158.00 71.70 5 135 1-1/2 41 1.883 47.8 0.090 2.29 3.025 9 11 8.80 194.00 88.00 5 110 2 53 2.360 59.9 0.095 2.41 3.025 9 11 11.61 256.00 116.10 5 80 2-1/2 63 2.857 72.6 0.140 3.56 3.010 9 10-1/2 20.00 441.00 200.00 37 3 78 3.476 88.3 0.140 3.56 3.010 9 10-1/2 24.63 543.00 246.30 30 3-1/2 91 3.971 100.9 0.140 3.56 3.005 9 10-1/4 28.53 629.00 285.30 24 4 103 4.466 113.4 0.140 3.56 3.005 9 10-1/4 31.75 700.00 317.50 24

BS31: 1940 THREADED CONDUIT Heavy Gauge Class B Trade Size Designator Outside Diameter Wall Thickness Unit Length Weight Quantity In Primary Master in. mm in. mm in. mm m kg/pc kg/m kg/ft Pcs Pcs ¾ 19 0.745 18.9 0.063 1.6 1 25 0.993 25.2 0.063 1.6 1-1/4 32 1.245 31.6 0.063 1.6 1-1/2 38 1.493 37.9 0.071 1.8 2 50 1.992 50.6 0.080 2.0 3.05 2.14 3.81 2.67 3.05 2.90 3.81 3.62 3.05 3.66 3.81 4.57 3.05 5.00 3.81 6.25 3.05 7.44 3.81 9.30 0.70 0.21 10 50 0.95 0.29 10 50 1.20 0.37 5 25 1.64 0.50 5 25 2.44 0.74 3 15 BS 4568: Part 1:1970 THREADED CONDUIT Heavy Gauge Trade Size Designator Outside Diameter Wall Thickness Unit Length Weight Quantity In Primary Master mm mm mm m kg/pc kg/m kg/ft 20 19.85 1.6 25 24.80 1.6 32 31.80 1.6 3.00 2.14 3.75 2.67 3.81 2.72 3.00 2.71 3.75 3.39 3.81 3.44 3.00 3.56 3.75 4.44 3.81 4.51 (Pcs) (Pcs) 0.713 0.217 10 50 0.903 0.275 10 50 1.185 0.361 5 25

Southern Steel Southern Steel Pipe Sdn. Bhd. (237316-T) 4457, Mk. 15, Jalan Chain Ferry 12100 Butterworth, P. W., Malaysia Tel: +604-331 7393 (Hunting line) Fax: +604-331 0942 Website: www.spim.com.my www.southsteel.com E-mail: contact@southsteel.com For further enquiries, please Call: +604-331 4060 Fax: +604-331 0942 To place your order, kindly call: Care has been taken to ensure that the content of this catalog is as accurate as possible. Southern Steel Pipe however does not accept any liability whatsoever for errors or for any information which is found to be misleading. The contents of this catalog may change from time to time without prior notice. QUALITY SYSTEM SIRIM CERTIFIED TO MS ISO 9001:2000 REGISTRATIONNOAR 0431