TRANSWORLD AQUATIC ENTERPRISES INC.

Similar documents
Fold Here. Stamp. Transworld Aquatic Enterprises, Inc 3730 W. Century Blvd #3 Inglewood, CA Phone: (877) JBJLIGHTING.

TRANSWORLD AQUATIC ENTERPRISES INC.

TRANSWORLD AQUATIC ENTERPRISES INC.

Clamp 4W Clamp 8W. Owner s Manual

SR-60 SR-80 SR-120. Owner s Manual 1

CHAETOMAX. 2 in 1 Refugium LED. Owner s Manual 1

Important Safety Instructions 3-4

MiniMax Sump #7304. Owner s Manual 1

HYDROFILL ATO Controller System

16" and 20" Economy Incandescent Full Hoods Owner s Manual

Owner s Manual Compact Fluorescent Lunar Aqualight

Owner s Manual. High Output T5 Lunar Aqualight. Aquarium Light Fixture. Featuring: Directional Lunar Blue LEDs

Lighting Placement. Adjusting Mounting Legs

A. Set-Up with gravel

EZ CLEAN IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. External Aquarium Filter

nova extreme retrofit High Output T5 Lighting Kit

Installation & Maintenance Guide

Manuel Guide Lighting Fixtures

AquaReef Cube. Inspiring Excellence in Fish Keeping!

EXPANDABLE 0.5W LED FRESHWATER LIGHT FIXTURES

100 Series Maxi Internal Filters

expandable led Installation & Maintenance Guide Product Description Light 48 IN 21.6W 10K/460nm Expandable Light 36 IN 15W 10K/460nm Expandable

Air Pump Up to 800 gallons

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

E-Flow Pumps. Operating instructions

IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic

SimplyClear Pressurized Filter Product Manual

IMPORTANT SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS. WARNING To guard against injury, basic safety precautions USA

Aquience 1200/1500 R

Monsoon RS400. Operating Instructions Mode d emploi Bedienungsanleitung Manual de Instrucciones Istruzioni per il funzionamento Gebruiksaanwijzing

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

Prime Tower. Inline Chiller. Instructions for Models #2645,2646

AllClear G2 Series Pressurized Filters Product Manual

Reflex. Inspiring Excellence in Fish Care!

ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL

Instruction Manual. Models 20, 30, 50, 70, and 110. English. Voir instructions en français à l'intérieur. See inside for Quick Start Guide!

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

gamma pond Ultraviolet Sterilizers

aquamanta the experts in aquatic technology

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

Instruction Manual. Professional. Electric Kettle. Questions or concerns about your electric kettle? Before returning to the store...

Reflex. 13/15/26/35. Inspiring Excellence in Fish Care! Instruction version:03/09/2013

Prime Chiller 1/10th HP Chiller

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Betta Mono. Inspiring Excellence in Fish Care!

AQUARIUM HEATER RANGE AH-25 / AH-50 AH-100 / AH-200 AH-300

ULTRASONIC HUMIDIFIER

Prime Chiller Mini-Chillers

OPERATING MANUAL BIRD VERTICAL DISPLAY SYSTEMS

OPERATING MANUAL KOI / PLANT DISPLAY SYSTEM

Halo Programmable LED Aquarium Light. Quick Start Guide

Thermoelectric Cooler. Wine Cellar. Instruction Manual. Model PEC-806

STAINLESS STEEL ELECTRIC KETTLE

COFFEE MAKER. Instruction Booklet 1 CUP. Model : TFC-343

ULTRASONIC HUMIDIFIER With Night Light and Fragrance Diffuser

With Remote Control. English

MCE 400. Operating instruction and Spare parts list

AquaStream. ½ HP Floating Fountain. Please Keep for Your Records. Model #AS05 6A, 120V/60Hz Owner s Manual UNIT IDENTIFICATION

Electric Digital Kettle

ELECTRIC STOVE HEATER Models: FS2213B

9 TWIN WINDOW FAN MODEL: FW23-A1 SKU:

Prime Chiller Modular Upgradable Chiller

PLEASE READ BEFORE USE AND SAVE. Ultrasonic. with Ionization. INSTRUCTION MANUAL MODEL HUNi

SMALL ANIMAL VERTICAL

Instruction Manual. Electric Kettle. Questions or concerns about your electric kettle? Before returning to the store...

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

LINEAR AIR PUMPS INSTRUCTION MANUAL SERIES PRO TM

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

COVER MODEL# GDK240 DIGITAL KETTLE. PHOTO OF PRODUCT

ULTRASONIC HUMIDIFIER

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

Breakfast-To-Go. Instruction Manual. 3-in-1 Toaster Oven, Coffee Maker and Griddle. Model: ABT-203W

DZ5080 US Index01 19/09/07 10:50 Page 2

DIGITAL ULTRASONIC HUMIDIFIER WITH HUMIDISTAT

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

SAVE THESE INSTRUCTIONS

NO VENTING REQUIRED 120V AC;

RJ11-17-TI CORDLESS GLASS ELECTRIC KETTLE. CUSTOMER SERVICE:

Monsoon RS400. Operating Instructions Mode d emploi Bedienungsanleitung Manual de Instrucciones Istruzioni per il funzionamento Gebruiksaanwijzing

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

LIGHTED PARTY FOUNTAIN Model # LPF-210

Instruction Leaflet 99.97% TRUE HEPA AIR PURIFIER. pure indoor living MODEL: BAP925-CN. Replacement filters: A1230H and A1260C

Instruction Manual. Electric Kettle. Questions or concerns about your electric kettle? Before returning to the store...

Tower Fan MODEL# EE-5607

MIGHTY PRO 1/4 HP CHILLER

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5067

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

Zeolite Reactor ZA 509, ZA 512, ZA 616

IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS

PROFESSIONAL CURLING IRON with adjustable temperature settings and Auto Shut Off after 60 minutes

CORDLESS GLASS ELECTRIC KETTLE WITH BONUS TEA INFUSER

20 INCH ELECTRIC GRIDDLE

1 GALLON / 3.78 LITER ULTRASONIC HUMIDIFIER

Installation & Maintenance Guide

Garment Steamer Model SC620

IMPORTANT SAFETY INSTRUCTIONS

Alen T500 HEPA Air Purifier

Transcription:

TRANSWORLD AQUATIC ENTERPRISES INC.

TABLE OF CONTENTS Important Safety Instructions 3 5 Picotope Parts View 6 9 Introduction 10 11 Getting Started 12 Lighting 13 Maintenance Procedures 14-15 Maintenance Log 16-18 Warranty Information 19 Notes 20-21 2

WARNING To guard against injury, basic safety precautions should be observed, including the following: READ ALL SAFETY INSTRUCTIONS BEFORE USE. DANGER To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment. For each of the following situations, do not attempt to repair yourself: return the appliance to an authorized service facility for service or discard the appliance. A. If the appliance falls into water, DON T reach for it! First unplug it and then retrieve it. If the electrical components of the appliance get wet, unplug the appliance immediately. B. Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not intended to be wet. C. Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or if it is dropped or damaged in any manner. D. To avoid the possibility of the appliance plug or receptacle getting wet, position aquarium stand and tank to one side of a wall mounted receptacle to prevent water from dripping onto the receptacle or plug. A drip loop, shown in the Figure at the right should be arranged by the user for each cord connecting an aquarium appliance to a receptacle. The drip loop is that part of the cord below the level of the receptacle or the connector if an extension cord is used, to prevent water travel along the cord and coming in contact with the receptacle. If the plug or the receptacle do get wet, DON T unplug the cord. Disconnect the fuse to the circuit breaker that supplies power to the appliance. Then unplug and examine for the presence of water in the receptacle. 3

E. Close supervision is necessary when any appliance is used by or near children. F. To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, and etc. G. Always unplug an appliance from the outlet when not in use, before putting on or taking off parts, and before cleaning. Never yank the cord to pull plug from the outlet. Grasp the plug and pull to disconnect H. Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition. I. Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing. J. Make sure an appliance mounted on a tank is securely installed before operating it. K. Read and observe all the important notices on the appliance. L. This Appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use with an extension cord unless plug can be fully inserted. Do not attempt to defeat this safety feature. M. This appliance is intended FOR HOUSEHOLD USE ONLY. Do not use or mount this appliance in such a way that the top vents are restricted or blocked. These vents are necessary to avoid over-heating and insure safe operating temperature. O. Make sure that the appliance is set on a level surface to prevent undue stress on the aquarium tank from stress and leaks. It is not recommended that this appliance is set upon coffee tables, end tables, T.V. stands, or night stands unless the structure has been properly tested to within the weight limits of the aquarium. 4

CLEANING It is important to keep this appliance clean. Always unplug the appliance before performing maintenance or cleaning of the exterior of this hood. Wipe exposed surfaces carefully with a damp terrycloth to remove any dust or mineral deposits which may collect over time. Make sure all surfaces are dry before re-plugging into an electrical outlet. To prevent scratching the aquarium, use a damp terrycloth when cleaning. Never use algae scrapers, scouring pads, razor blades, glass cleaner or other such abrasives. SERVICING In order to assure proper electrical connections and polarity, replacement parts and servicing should be performed only by a qualified electrician. OPERATION Please carefully read the entire Owner s Manual for proper operation procedures before proceeding with turning on this appliance and adding livestock such as fish, corals, and invertebrates. SAVE THESE INSTRUCTIONS 5

PARTS EXPLODED VIEW & IDENTIFICATION 3 GALLON CURVED GLASS STARTER TANK (0) PARTS EXPLODED VIEW & IDENTIFICATION PICO FILTER 6

3 GALLON CURVED GLASS REPLACEMENT PARTS LIST & DESCRIPTION PART # Name MX-30-0 WF-2015 1 WF-2015 2 WF-2015 3 WF-2015 4 WF-2015 5 WF-2015 6 WF-2015 7 WF-2015 8 WF-2015 9 WF-2015 10 WF-2015 11 Tank Only Filter Box Cover Mechanical Sponge Biological Sponge Flow Valve Intake Tube Elbow Filter Box Impeller / Magnet Assembly Motor Extension Tube Filter Brace Strainer 7

PARTS EXPLODED VIEW & IDENTIFICATION LAMP FIXTURE 8

REPLACEMENT PARTS LIST & DESCRIPTION PART # Name CL-609 T Light top Cover CL-609 1 Aluminum Reflector CL-609 2 Lamp Clip CL-609 3 CF Lamp CL-609 4 Lamp Cover CL-609 5 Screws CL-609 6 Telescoping Arms CL-609 7 Spiral Cord CL-609 8 Switch Cover CL-609 9 Switch CL-609 10 CL-609 11 CL-609 12 Clamp Base Clamp Base Bottom Cover Magnetic Power Supply 9

BIGGER ISN T ALWAYS BETTER! Thank you for purchasing the JBJ 3 Gallon Curved Glass PICOTOPE. This beautiful glass desktop is an excellent starter tank that offers rounded glass corners for panoramic viewing, beveled glass bottom, a 9 watt 50/50 Clamp on Lamp, and Pico Powerfilter. The PICOTOPE is sure to add a touch of elegance and style to any room it enters! JBJ ILLUMINATION SYSTEM Our unique Clamp on Lamp fixture hangs on the back wall and can be positioned UP, DOWN, and even FORWARD to find that perfect illumination spot to view your favorite live animal. This energy saving JBJ Compact Fluorescent fixture contains a 9 watt 50/50 lamp with a remote ballast for a cooler running pico environment Advanced Features: Telescoping Arms Adjustable light hood Space-saving Design Remote Ballast 2-in-1 Lamp (blue & white) Energy Efficient Our illumination system is the ideal choice to house: A. Freshwater Fish B. Invertebreates C. Mushrooms D. Zooanthids E. Live Rock SPECIFICATIONS Power: 9 Watt Model: CL-609 Kelvin (lamp color): 50/50 CF Lamp (Half 7100K Blue/Half 10K White) Ballast Type: Magnetic / Remote Tank Dimensions: 11.8 x 8.9 x 8.1 Capacity: 3 US Gallons 10

CRYSTAL CLEAR CURVED GLASS The PICOTOPE starter aquarium offers panoramic viewing with smooth rounded corners for maximum viewing and enjoyment. PICO POWERFILTER The PICO Powerfilter is a revolutionary innovation that offers the same 3 stage filtration commonly designed for larger filters in a spacesaving hang-on design. Pumps are integrated and do not require assembly. All models include the following: 1. Mechanical Filtration Black filter sponge traps free floating particulate matter and debris. 2. Chemical Filtration Activated Carbon Bag removes dissolved organics and odor. 3. Biological Filtration White sponge offers maximum surface area to colonize beneficial bacteria to remove harmful toxins. Filtration Water Flow Pattern FILTER SPECIFICATIONS Model: WF-2015 Voltage: 115V Power: 6 Watts GPH: 40 gph Dim: 3.3 x 3 x 4 Note: Always fill PICO Powerfilter with water before plugging into an approved 115V outlet. Pump may need 30 seconds to 1 minute to prime and start filtering. If pump does not start, add more water into rear of filter with a cup. 11

HANDLING PRECAUTIONS Never attempt to move a full or partially full PICOTOPE. Never lift by grabbing the aquarium walls. Never use cleaners that contain ammonia to clean the glass surfaces. Always lift and carry the PICOTOPE from underneath giving support to the bottom at all times. CHOOSING A LOCATION Find a leveled surface that can support the weight of the tank, water, and livestock. An average aquarium can weigh 10lbs per gallon once filled with water, rock, gravel, and other accessories. Do not place in direct sunlight to prevent excessive algae growth and higher water temperatures. FILLING THE TANK Always dechlorinate tap water before adding into the aquarium. Always fill with room temperature water. Rinse Activated Carbon which is located in the rear filter compartment under the sink for 30 seconds or until water runs clear. Fill the main body of the PICOTOPE until water reaches the bottom of the clamp for the light fixture. Once PICOTOPE is filled, plug PICO powerfilter power cord into an approved electrical outlet with a fuse or circuit breaker. Once filter is on, water will enter intake strainer through the filtration media and return back into the tank. ADDING A HEATER ( not included) If you wish to keep tropical (warm water) fish you will need a submersible heater to maintain optimal water temperatures to simulate their natural environment. Most tropical fish will need a temperature range between 74-78 F for optimal living conditions. A heater can be placed in the main body of the PICOTOPE behind accessories such as decorations, plants, or rocks. We recommend a small 100% submersible 25-50 watt heater if necessary. Note: Evaporation occurs faster in smaller tanks that have open tops. Please check water level regularly to ensure filter is functioning properly 12

Light hood Cover Telescoping Arms Light Switch TURNING ON YOUR LIGHTING SYSTEM Your PICOTOPE is pre-installed with a dual color lamp that offers daylight and blue actinic light in one compact design. A. Plugging the Remote Ballast 1. Plug power-cord from the remote ballast into an outlet strip that is properly approved and equipped with a fuse or circuit breaker. 2. Press the switch located on clamp portion of the light fixture to ON position to turn on compact fluorescent lamp. * We recommend you keep a photoperiod of 8-10 hours per day to replicate a natural cycle that your livestock has grown accustomed to. ADJUSTING THE TELESCOPING ARMS Your PICOTOPE has an innovative set of telescoping arms that can be extended and retracted to meet your specific lighting needs. The telescoping arms can be adjusted 180 degrees from front to back. Please careful not to handle the fixture during operation. Light fixture may be warm to hot and should not be adjusted until time has been allowed to properly cool down. Never allow water contact on any part of the Clamp on Lamp. Never service the light fixture while fixture is plugged into an electrical socket. 13

Regular maintenance is the key to a successful thriving aquarium. Maintaining an aquarium can be very easy with a regular cleaning schedule. WATER CHANGES A. Water changes should be carried out on monthly to bi-monthly schedule depending on how much bio-load is kept. B. 25% water changes with gravel vacuuming is essential to keep dissolved organic carbons to a minimum. REPLACING THE BLACK FILTER SPONGE A. Filter Sponge should be changed on a monthly basis to remove trapped debris and free floating particulate matter. REPLACING THE ACTIVATED CARBON A. Activated Carbon adsorbs dissolved pollutants and removes the yellow discoloration of water and associated odors. B. Replace Activated Carbon Bag on a monthly basis. REPLACING THE WHITE BIOLOGICAL FILTER SPONGE A. Biological sponge should not be removed as it houses the beneficial nitrifying bacteria for removal of ammonia and nitrite. B. This sponge does not need to be changed. NOTE Pico Filter should always be unplugged before changing media. Remove filter top cover and change media. Always remember to fill up Pico Filter with water before plugging back into an electrical wall outlet. 14

SAFETY Always disconnect the power supply from the wall outlet when performing lamp changes CHANGING THE LAMP Your PICOTOPE is installed with the following: Model Bulb Item # Description Kelvin MX-30 3 GALLON PICOTOPE B9-BW10K 9 Watt Compact Fluorescent Lamp Half 10K Daylight/ Half 7100K Actinic Blue We recommend replacing lamps every 9-12 months due to a decline in intensity which is vital for corals and invertebrates. Spectral shifts may also occur that may lead to undesirable algae growth. Removing the lamp from fixture 1. Unclamp the light fixture from the tank rim. 2. Lay light fixture down on a leveled surface and unscrew light cover. 3. Unclip lamp from bulb clips. 4. Unplug the (2) female wires from the male pins at the base of the lamp. 5. Re-insert new replacement lamp and reconnect wires, place into bulb clips, and screw on light cover. 15

DATE MAINTENANCE 16

DATE MAINTENANCE 17

DATE MAINTENANCE 18

WARRANTY INFORMATION 6 Month Limited Warranty This Picotope aquarium is warranted to the original purchaser against defective material and workmanship for 6 months from the date of original purchase. This warranty is valid only under the following conditions: additions, modifications, or changes made to the product by the purchaser and not by the manufacturer shall void this warranty. Damages brought on by abuse, misapplication, or mishandling also voids this warranty. Aquariums must be placed on leveled surfaces or stands designed specifically for the Picotope. This warranty is limited to the repair or replacement of the product at the discretion of the manufacturer. This warranty does not cover personal injury, property loss, including livestock or damage (direct, incidental, or consequential) arising out of use of this product. This warranty gives you specific rights and you may also have other rights, which may vary from state to state. Upon discovery of a defect, please call us to obtain an RMA #. Tel: (310) 672-4099 / Tel: (310) 672-4021 All claims should be sent prepaid to the following address: Transworld Aquatics Enterprises, Inc. 3730 Unit 3, West Century Blvd. Inglewood, CA 90308 Customer Service Information For additional information or technical assistance please call us at (310) 672-4099, M-F from 9AM-5PM (Pacific Standard Time). 19

20

21

22

23

Transworld Aquatic Ent., Inc 3730 West Century Blvd, Suite 3 Inglewood CA 90303 Phone: 310-672-0480 Fax: 310-672-7261 E-mail: sales@jbjlighting.com 24