www.sylvania.com/ledr D6 rea Light LED Retrofit Key Features & enefits The D6 rea Light LED Retrofit from SYLVNI is an alternative to high-intensity discharge (HID) lamps up to 250W at pole heights up to 30 feet. The directional light distribution of high power LEDs allows the delivery of light only where needed, reducing wasted light and minimizing light trespass and upward emissions. The D6 is an environmentally preferable lighting solution as it contains no mercury or lead. It is an excellent solution for communities that wish to convert their existing lighting systems as it offers substantial energy and maintenance cost savings as well as minimizes waste in landfills. OSRM SYLVNI will provide direction and assistance to customers to ensure proper installation of the D6 unit. This device complies with part 15 of the F Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For F Part 15 user information, please see www.sylvania.com/fcc15b. Reduces energy consumption up to 68% Provides significant maintenance cost savings by lasting 2-6 times longer than HID lamps Enhances light quality with better uniformity and color performance 70,000 hours life at 70% lumen maintenance 120-277V input voltage at 60Hz with 10kV surge protection UL1310 recognized lass 2 OPTOTRONI power supply Mercury free Product Offering UV and IR free RoHS compliant Up to 30 feet mounting height bility to power down for sunrise and sunset to save energy with dual ballast Smaller diameter to fit into most applications hardware included in kit and for all three methods: Top, Middle, ottom SSEMLED IN US Ordering Wattage olor Light bbreviation (W) Temperature Distribution LED35RETROFIT/741 35 4100K Type-V Medium LED35RETROFIT/750 35 5000K Type-V Medium LED55RETROFIT/741 55 4100K Type-V Medium LED55RETROFIT/750 55 5000K Type-V Medium and Type-III Medium LED55RETROFIT/656 55 5600K Type-V Short and Type-III Short LED70RETROFIT/741 70 4100K Type-V Medium LED70RETROFIT/750 70 5000K Type-V Medium pplication Information pplications ollege and business park campuses Historic restorations and downtown business districts Public lots and garages Residential roadways, walkways and bikeways Shopping centers, malls and plazas pplication Notes 1. Maximum mean ambient operating temperature outside the fixture is 40 2. Maximum ambient operating temperature outside the fixture can not exceed 60 3. To prevent personal injury or product damage only licensed electricians should provide all installation services 4. Please read installation manual before attempting installation 5. Recommended mounting height up to 30 feet 6. UL classification for post top and shoebox fixtures RETRO017R8 6/12
Ordering Information atalog # Project omments Prepared by Specification Data Type Input Typical Item Ordering Wattage Voltage Efficacy Rated Lumens Operating UG Number bbreviation (W) 1 (V) Factor 2 (lm/w) 3 Life (hrs.) 4 (lm) 5 T 6 RI Temperature Rating 78647 LED35RETROFIT/741/T5M/D6 35 120-277 0.98 74 70,000 2600 4100K 78-30 to 40 2 U2 G1 78646 LED35RETROFIT/750/T5M/D6 35 120-277 0.98 74 70,000 2600 5000K 76-30 to 40 2 U2 G1 78645 LED55RETROFIT/741/T5M/D6 55 120-277 0.98 65 70,000 3600 4100K 78-30 to 40 2 U2 G1 78631 LED55RETROFIT/756/T3S/D6 55 120-277 0.98 65 70,000 3600 5600K 71-30 to 40 2 U2 G1 78628 LED55RETROFIT/750/T5M/D6 55 120-277 0.98 71 70,000 3900 5000K 77-30 to 40 2 U2 G1 78648* LED55RETROFIT/750/T5M/D6OEM 55 120-277 0.98 71 70,000 3900 5000K 77-30 to 40 2 U2 G1 78630 LED55RETROFIT/750/T3M/D6 55 120-277 0.98 69 70,000 3800 5000K 78-30 to 40 2 U2 G1 78629 LED55RETROFIT/656/T5S/D6 55 120-277 0.97 67 70,000 3700 5600K 69-30 to 40 2 U2 G1 78915 LED70RETROFIT/741/T5M/D6/HP 70 120-277 0.90 85 70,000 6000 4100K 70-40 to 40 2 U2 G1 78882 LED70RETROFIT/750/T5M/D6/HP 70 120-277 0.90 85 70,000 6000 5000K 70-40 to 40 2 U2 G1 1. Typical wattage while operated at 120V is 54W (±10%). Typical wattage while operated at 277V is 59W (±10%). 2. factor at 120V supply voltage 3. Thermally stable typical efficacy (±10%) 4. Hours lifetime with 70% lumen maintenance. ased on operation temperature at 104 F (40 ). 5. Thermally stable typical lumens (±10%) 6. Thermally stable typical T (±300K) * OEM version comes without the power supply, surge protector and mounting hardware. Ordering Guide LED 55 RETROFIT / 750 / T5M / D6 LED Lamps Wattage: Retrofit RI, T: Light Distribution: Diameter: and Retrofits 35W, 55W, 70W 750: 70+ RI, 5000K T T5M: Type-V Medium 6 inches 756: 70+ RI, 5600K T T5S: Type V Short 741: 70+ RI, 4100K T T3M: Type III Medium 656: 60+ RI, 5600K T T3S: Type III Short Ordering Information Item Number Ordering bbreviation IP Rating 51530-2 OT40/UNV/1110E* IP66 * onstant current power supply (1.11). UL 1310 and UL 48 recognized for US & anada. lass 2 unit Technical Information For optimal performance in your fixture, please consult OSRM SYLVNI for application assistance. LED oard Optics Heat Sink Top Top racket LED Side wire (blue) Side Four (4) Side brackets ssembly* () () () Width/Diameter MOL Length 6.8" 3.7" ssembly 4.2" 6.1" 2.8" ssembly Two (2) OPTOTRONI Surge Protector Side wire (white) ottom enter Pole Disk * supply assemblies in images above are for 55W and 70W model. ssembly for 35W model will contain only one power supply, but retain the same overall bracket dimensions.
Wiring Diagram Notes: 1. surge protector and OPTOTRONI power supplies are pre-wired in ssembly. POWER SUPPLY SSEMLY FOR 35W MODEL LED LIGHT ENGINE OT40/UNIV/1400E POWER SUPPLY SSEMLY FOR 55W ND 70W MODEL LED LIGHT ENGINE OT40/UNIV/1110E POWER SIDE 120-277 V (White Jacket) 18WG 4 feet LED SIDE 18-36 VD (lue Jacket) 20WG 4 feet ssembly Diagram * Refer to Installation Manual for mounting instructions ssembly Top ssembly Side ssembly ottom Top anopy light obra head High/Low bay Parking garage Pendant Shoebox Wall pack Side anopy light obra head High/Low bay Parking garage Pendant Shoebox Wall pack ottom
Photometric Distribution LED55RETROFIT/750/T5M/D6: Illuminance Diagram Luminous Intensity Distribution 0.02 0.05 0.5 1. 2. 0.2 0.1 500 0.01 1000 1500 Height = 10' Each box is one mounting height. Type V Medium, 5000K T Illuminance in footcandles 1999 Intensity in candelas Max. plane at H = 0 Max. cone at V = 71 Max. candlepower = 1326 Type V Medium, 5000K T LED55RETROFIT/757/T5S/D6: Illuminance Diagram Luminous Intensity Distribution Height = 10' Each box is one mounting height. Type V Short, 5700K T Illuminance in footcandles Intensity in candelas Max. plane at H = 292.5 Max. cone at V = 60 Max. candlepower = 1102 Type V Short, 5700K T
Warranty Refer to OSI Post-Top LED Retrofit Statement of Limited Warranty. Visit SYLVNI.com for recent case studies on energy and environmental savings on this product. SYLVNI is a registered trademark of OSRM SYLVNI Inc. SEE THE WORLD IN NEW LIGHT is a registered trademark of OSRM SYLVNI Inc. OPTOTRONI and Global are are registered trademarks of OSRM G. ll other trademarks are those of their respective owners. Specifications subject to change without notice. United States OSRM SYLVNI 100 Endicott Street Danvers, M 01923 1-800-LIGHTUL Trade Phone: 800-255-5042 Fax: 800-255-5043 National ccounts Phone: 800-562-4671 Fax: 800-562-4674 OEM/Special Markets Phone: 800-762-7191 Fax: 800-762-7192 Retail Phone: 800-842-7010 Fax: 800-842-7011 SYLVNI Lighting Services Phone: 800-323-0572 Fax: 800-537-0784 Display/Optic Phone: 888-677-2627 Fax: 855-543-1043 anada OSRM SYLVNI LTD. 2001 Drew Road Mississauga, ON L5S 1S4 1-800-LIGHTUL Trade Phone: 800-263-2852 OEM/Special Markets/Display/Optic Phone: 800-265-2852 Retail Phone: 800-720-2852 SYLVNI Lighting Services Phone: 800-663-4268 Fax: 866-239-1278 Mexico OSRM MEXIO Tultitlan/Edo de Mexico Phone: 011-52-55-58-99-18-50 ENELIUM Technologies United States Phone: 201-928-2400 Fax: 201-928-4028 anada Phone: 905-731-7678 Fax: 905-731-1401 www.sylvania.com 2012 OSRM SYLVNI 6/12 Photography