! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.

Similar documents
! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Service. Electric Freestanding Range

Service. Freestanding Double Oven Electric Range

Service. Gas Freestanding Range AGR5715QD* AGR5735QD* AGR5835QD* JGR8775QD* JGR8875QD* MGR5754QD* MGR5755QD* MGR5765QD* MGR5775QD* MGR5875QD*

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

Electric Slide-In Range JES8750BA* JES8850BA* JES8850BC* JES9750BA* JES9800BA* JES9860BA* JES9860BC* JES9900BA* JES9900BC*

Heating elements BSH/series 700 -convection system- FULGOR. SpA ELETTRODOMESTICI

Dacor Technical Service

KITCHENAID CONSUMER SERVICES Technical Training Department

Oakton TEMP 9500 Advanced Multiparameter Controller

SERVICE DATA SHEET (9704) Rev. D

Service. Gas Wall Oven JGW8130DD*

Technical Seminar HL-BD82S. Electric Built-In Oven. Panasonic Canada 2013

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

FOR SERVICE TECHNICIAN S USE ONLY

TABLE OF CONTENTS ELECTRIC BUILT-IN OVEN. Model No. HL-BD82S. Canada

30 Freestanding Gas Ranges AGR5712BD* MGR4451BD* MGR4452BD* MGR5751BD* MGR5752BD* MGRH752BD* MGRH752CD* MGRL752BD* MGRL753BD* MGRM752BD* MGRS752BD*

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Electric Double Wall Oven

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

C Series Oven Training Program

GE JB400 Steam Clean Range. Range Models: JB400DP1WW JB400DP1BB JB400SPSS

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

WFR 2460 Service Tips -- Test Program

Model OD302 Model OS302 MODELS A

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Note: The oven function will not work if the time of day clock is not set. Pad- Used to to start all oven. Timer or Oven Light. Timer On/Off.

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Maytag Gemini Range Service Manual

DYGIZONE GJD910 Lighting Controller & Enunciator

Follett Performance Plus

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

KEY FEATURES. EvenCook 3

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.

Service Manual. Thermador Built-In Oven. for. Models: SMW272 B, SMW272S, SMW272W, SMW272P STOP TIME SELF CLEAN OVEN LIGHT COOK TIME BAKE OFF

Analog Room Pressure Monitor RPC Series

FOR SERVICE TECHNICIAN S USE ONLY

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

CAUTION. To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing. MDBTT50AW*

FOR SERVICE TECHNICIAN S USE ONLY

Installation Instructions Wall Ovens

Owner s Manual GEMINI PETIT CHEF MULTIFUNCTION THERMOFAN

Service. Electric Slide-In Range

INSTALLATION INSTRUCTIONS

Technical Service Guide

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Carbon Monoxide Transmitter

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

S Series Ovens. Thermador Field Service

TECH SHEET - DO NOT DISCARD PAGE

VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD,MS USA

FOR SERVICE TECHNICIAN S USE ONLY

JDB4000AWB JDB4000AWQ JDB4000AWS JDB4000AWW MDB5600AWB MDB5600AWQ MDB5600AWS MDB5600AWW

DIAGNOSTIC GUIDE DIAGNOSTIC TEST DISPLAY FAULT/ERROR CODES IMPORTANT. Activating the Diagnostic Test Mode. Before servicing, check the following:

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

Activating the Test Mode. Test Mode Functionality

Comfort System T-21-P Touchscreen Thermostat Installation Manual


WARNING FOR SERVICE TECHNICIAN S USE ONLY

Technical Information- Dishwasher MDB8750AWB MDB8750AWQ MDB8750AWS MDB8750AWW MDB9750AWB MDB9750AWQ MDB9750AWS MDB9750AWW

WARNING. Electrical Shock Hazard FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY L WASHER. Pub # /18/10 GE

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

PHASE NON-COIN USER S MANUAL (S.A.F.E.)

TECH SHEET DO NOT DISCARD PAGE 1. If unsuccessful entry into diagnostic mode, actions can be taken for specific indications:

SERVICE MANUAL. Kleenmaid SMART oven OMFHS6010

Installation/Owner s Manual Models 1504 / 1506

Technical Service Guide

Built-In Microwave EW27SO60L S. Featuring Wave-Touch Electronic Controls

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

M4.9. NO LONGER IN PRODUCTION Some service parts may not be available for this product- Service and Parts Manual M4.9-0

Model 60200FR Gas Primary Control Data Sheet

Freestanding Ranges FGGF301DN F/ W/ B. 30" Gas. Signature Features. More Easy-To-Use Features. Product Dimensions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Fast Track Troubleshooting

DT968C C.T. BATH CONTROLLER

Oakton TEMP 9000 Advanced Thermocouple Controller

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Dryer Controller M720

O PE R AT I ON HO851G REVOLVING TRAY OVEN. MODEL HO851G GAS ML Pan ML Pan ML Pan ML Pan

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Safety & Installation Instructions

FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY

User Manual. Dryer Controller M720

Transcription:

Electric Wall Oven Technical Information JJW8627DD*, JJW8630DD*, JJW9627DD*, JJW9630DD*, JJW9827DD*, JJW9830DD* Refer to Service Manual 16022506 for detailed installation, operating, testing, troubleshooting, and disassembly instructions. Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.! CAUTION All safety information must be followed as provided in Service Manual 16022506. This oven contains ESD-sensitive electronics. An ESD discharge may weaken or damage electronic components in the oven. This could cause immediate failure or reduced product life. The following precautions must be taken when working on the oven: Wear an antistatic wrist strap. Connect the free end to a bare metal surface on the oven. Handle all electronic components by their edges only Do not touch contacts, terminals, or individual components on the printed circuit boards. Touch all anti-static bags to a bare metal surface on the oven before removing parts from their bags. Observe all of these precautions when dealing with old or new electronic components. Models JJW8627DD* JJW8630DD* JJW9627DD*, JJW9827DD* JJW9630DD*, JJW9830DD* Power Source Electrical rating 240 VAC 208 VAC 240 VAC 208 VAC 240 VAC 208 VAC 240 VAC 208 VAC 7.2 kw 5.4 KW 7.2 kw 5.4 KW 7.2 kw 5.4 KW 7.2 kw 5.4 KW Amperage maximum 30 Amp 26 Amp 30 Amp 26 Amp 30 Amp 26 Amp 30 Amp 26 Amp Frequency 60 Hz 60 Hz 60 Hz 60 Hz Oven Wattage @ 240 V / 208 V Convection N/A N/A N/A N/A 1850 W 1603 W 1850 W 1603 W Bake 2800 W 2100 W 2800 W 2100 W 2800 W 2100 W 2800 W 2100 W Broil 3600 W 2700 W 3600 W 2700 W 3600 W 2700 W 3600 W 2700 W Oven Cutout Dimensions in. (cm) Height 51 7/8 131.7 51 7/8 131.7 51 7/8 131.7 51 7/8 131.7 Width 25 1/2 64.7 28 1/2 72.4 25 1/2 64.7 28 1/2 72.4 Depth 24 min. 60.9 24 min. 60.9 24 min. 60.9 24 min. 60.9 Product Exterior Dimensions in. (cm) Height 52 1/4 132.7 52 1/4 132.7 52 1/4 132.7 52 1/4 132.7 Width 26 3/4 67.9 29 3/4 75.5 26 3/4 67.9 29 3/4 75.5 Depth 25 1/2 64.7 25 1/2 64.7 25 1/2 64.7 25 1/2 64.7 Clearance with oven door open 47 1/2 120.7 46 1/2 118 47 1/2 120.7 46 1/2 118 Weight lbs. (kg) Approximate shipping weight 285 129.3 305 138.3 285 129.3 305 138.3 Unit Features Electronic oven control X X X X Counterbalanced oven door with X X X X viewing window Interior oven light X X X X Automatic oven door latch X X X X Porcelain broiler pan and grid X X X X Oven racks with six positions Two racks Two racks Six racks Six racks Multi-Mode convection system N/A N/A X X September 2003 1

Component Testing Procedures Illustration Component Test Procedure Results Oven light housing Disconnect connector and test Verify bulb is plugged in properly. resistance of terminals... Indicates continuity with bulb installed. Measure voltage at oven light... Bake element Test continuity of terminals... Test voltage to terminals... 12 VAC, see wiring diagram for terminal identification. If no voltage is present at oven light, check wiring or light switches. Approximately 20 Ω - cold 240 / 208 VAC Broil element Test continuity of terminals... Test voltage to terminals... Approximately 15 Ω - cold 240 / 208 VAC Convection element Test continuity of terminals... Test voltage to terminals... Approximately 30 Ω - cold 240 / 208 VAC Convection motor fan Cooling fan motors Verify supply voltage... Check continuity of terminals, and verify terminals are not shorted to chassis... Verify supply voltage... Check continuity of terminals, and verify terminals not shorted to chassis 120 VAC Approximately 400 Ω 120 VAC Continuity Temperature sensor Measure resistance... Approximately 1080 Ω at room temperature (70 F). Controls Motorized door latch NC NO COM Verify proper operation. Switch connection in following positions: Unlocked... Open at 225 F, Closes at 165 F COM-NO=Open, COM-NC=Closed COM Primary Secondary NO Locked... Door switch Remove switch from unit and measure the following points: C-NO Stepdown transformer Verify input voltage... Verify output voltage... COM-NO=Closed, COM-NC=Open Plunger in continuity, Plunger out infinite. Approximately 120 VAC Approximately 12 VDC 2 September 2003

Component Testing Information Illustration Component Test Procedure Results UH2 Controlled Oven temperature adjustment Press SETUP pad. Press DOWN ARROW to scroll down to TEMP ADJUST. Select oven and enter desired temperature change. Press ENTER pad to accept the change. While increasing or decreasing oven temperature, this does not affect broiling or self-cleaning temperature. The oven offset does not need to be readjusted if there is a power failure. Oven can be adjusted from -35 to +35 degrees inputting 5 or 35 degrees by pressing +/- pad. To avoid over adjusting the oven, move temperature 5 degrees each time. Wait 4 seconds for the data entry timer to expire to accept the change. Temperature adjustment will be retained even through a power failure. UH2 Controlled Temperature display Press SETUP pad and use the arrow pad to scroll to the next screen. Select C/F, then select SET. Press SETUP pad to exit. UH2 Controlled Clock Display Press SETUP pad. Press CLOCK pad. Press TIME and enter numeric from key pad. Select AM or PM. Press SETUP to end. Press SETUP pad. Press CLOCK pad. Press DAY pad. Press back forward to select day of week. Press SETUP to end. Press SETUP pad. Press CLOCK pad. Scroll down to 12/24 HR. Scroll down to 12/24 HR format. Select SET to activate. Press SETUP pad to exit. Press DOWN ARROW pad to scroll to CLOCK. UH2 Controlled 12 Hour Shutoff Press SETUP pad. Press DOWN ARROW pad to scroll to 12 HOUR SHUTOFF pad. Select ON or OFF. Select SET pad to activate. Press SETUP pad to exit. UH2 Controlled Demo mode Press SETUP pad. Press DOWN ARROW pad to scroll to DEMO pad. Select DEMO to activate. Press SETUP pad to exit. UH2 Controlled Energy Saver Press SETUP pad. Press DOWN ARROW pad to scroll to ENERGY SAVER pad. Select ON or OFF. Select SET pad to activate. Press SETUP pad to exit. UH2 Controlled 208/240 V mode Press SETUP pad. Press DOWN ARROW pad to scroll to 208/240 V pad. Select 208 or 240. Select SET pad to activate. UH2 Controlled Control Lockout Press and hold BACK and ENTER pads for 5 seconds. To reactivate the control, press and hold BACK and ENTER pads for 5 seconds. This mode enables the user to indicate F or C on the display. Set clock, day of week, or 12/24 HR clock. Allows the time on the clock to be toggled from 12 hour or 24 hour display. Control will automatically cancel any cooking operation and remove all relay drives 12 hours after the last pad touch. To save energy, the display will turn off after five minutes of no use in time of day mode only. For improved results when using Radiant Bake only, the oven can be set from 240 V to 208 V. This is a safety feature that can be used to prevent accidentally programming the oven. It disables the electronic oven control and locks the cavity door(s). Control lockout features must be reset after a power failure. September 2003 3

Component Testing Procedures UH2 Controlled Sabbath Mode Press SETUP pad. Press DOWN ARROW pad. Press SABBATH pad to activate Sabbath mode. Select AUTO or MANUAL pad. If AUTO selected, press continue. If MANUAL selected, press ON or OFF. Select SET pad. Auto-Sabbath mode will display a reminder at 2:00 PM on Friday. Manual-Sabbath mode will be instantly programmed for 72 hours. This mode disables the normal 12 hour energy saving mode. Test Mode Follow procedure below to access the Test Mode. The time of day and day of week must be set correctly for this feature to be activated. 1. Press SETUP pad. 2. Press DOWN ARROW pad three times until SERVICE is displayed. 3. Press SERVICE pad. 4. Press and hold BACK and ENTER pads for 5 seconds. 5. Press TEST pad. NOTE: If the oven cavity temperature is greater then 400 F, the Test Mode cannot be activated or will abort the mode if activated. NOTE: Once the Test Mode is activated and a function is selected the control will activate the relay until the pad is pressed again. Upon entering TEST Mode all relays are turned off except the DLB relays, which are turned on. All relays are turned off when the TEST Mode is exited. Pad Pressed Beep Version Last Fault DISP Test UBAKE UBROIL UCONV UCOOL UCONV-H UCONV-L UMDL ULITE LBAKE LBROIL LCONV LCOOL LCONV-H LCONV-L LMDL LLITE Relay or Action Activated 1 Second Beep Version of software Display last error code and oven configuration (single, double, convection, nonconvection) Display segments Upper Bake Element Upper Broil Element Upper Convection Element Upper Cooling Fan Upper High Speed Convection Fan Upper Low Speed Convection Fan Upper Motorized Door Lock Upper Oven Light Lower Bake Element Lower Broil Element Lower Convection Element Lower Cooling Fan Lower High Speed Convection Fan Lower Low Speed Convection Fan Lower Motorized Door Lock Lower Oven Light 4 September 2003

Component Testing Information Description of Error Codes Error diagnostic codes can only be viewed by entering the Diagnostic Code Display Mode. Each error code is four digits long and is created based on the following table. Digit Description 1 st Primary System: 1 Local to the control circuit board 3 Sensor or meat probe 4 Control input 9 Door lock 2 nd Measurable: d Diagnostic failure: measurable parameter c Control related error, replace control 3 rd Primary failure mechanism 4 th Oven Cavity: 1 Upper oven (or single cavity oven) 2 Lower oven c Control specific Diagnostic Code Checking Code Description When Checked Detection 1c1c Shorted key Always 1 minute 1c2c Keyboard tail disconnected Always 1 minute 1c31 Cancel key circuit problem Always 20 sec 1c32 Cancel key circuit problem Always 20 sec 1c4c Power micro communication failure Always 20 sec 1c6c EEPROM error When accessing EEPROM 3 tries 1c7c Control not calibrated Always 3 tries 1c81 Cook profile corrupted in EEPROM Cook or clean programmed 3 tries 1c82 Cook profile corrupted in EEPROM Cook or clean programmed 3 tries 1d11 Runaway temperature (650 F), door unlocked Latch unlocked 1 minute 1d12 Runaway temperature (650 F), door unlocked Latch unlocked 1 minute 1d21 Runaway temperature (950 F), door locked Latch locked 1 minute 1d22 Runaway temperature (950 F), door locked Latch locked 1 minute 3d11 Temperature sensor failure (open) Cook or Clean active 20 sec 3d12 Temperature sensor failure (open) Cook or Clean active 20 sec 3d21 Temperature sensor failure (short) Cook or Clean active 20 sec 3d22 Temperature sensor failure (short) Cook or Clean active 20 sec 3d41 Meat probe shorted Probe cook programmed 20 sec 3d51 Meat probe not calibrated Always 3 sec 4d11 Door switch position failure Clean or Keyboard Lockout active 1 minute 4d12 Door switch position failure Clean or Keyboard Lockout active 1 minute 4d21 No Reverse Airflow Fan rotation (no/low RPM) Cook or Clean programmed 1 minute 4d22 No Reverse Airflow Fan rotation (no/low RPM) Cook or Clean programmed 1 minute 4d31 Reverse Airflow Fan state error (on when supposed When supposed to be off 1 minute to be off) 4d32 Reverse Airflow Fan state error (on when supposed When supposed to be off 1 minute to be off) 4d41 High Reverse Airflow Fan rotation, high RPM Cook or Clean programmed 1 minute 4d42 High Reverse Airflow Fan rotation, high RPM Cook or Clean programmed 1 minute 4d51 Door switch circuit failure Convect, Clean, or Keyboard Lockout 1 minute programmed 4d52 Door switch circuit failure Convect, Clean, or Keyboard Lockout 1 minute programmed 9d11 Latch will not lock 6 Latch should be locked See note 6 9d12 Latch will not lock 6 Latch should be locked See note 6 9d21 Latch will not unlock 6 Latch should be unlocked See note 6 9d22 Latch will not unlock 6 Latch should be unlocked See note 6 9d31 Latch both locked and unlocked 6 Latch should be locked or when lock attempted See note 6 9d32 Latch both locked and unlocked 6 Latch should be locked or when lock attempted See note 6 September 2003 5

Component Testing Procedures Diagnostic Code Handling Code Measured Display Action Taken 1c1c Keypress Disable audible for affected key depression, Disable all outputs 1, 2 Disable lights and timers 1c2c Keyboard loop improper value Disable audible for key depression, Disable all outputs 1 Disable lights and timers 1c31 Cancel key improper value mssg 1 (active) / mssg 2 (data) Disable all outputs for cavity 1 1c32 Cancel key improper value mssg 1 (active) / mssg 2 (data) Disable all outputs for cavity 1 1c4c CRC invalid mssg 1 (active) / mssg 2 (data) Disable all outputs 1 1c6c No response from EEPROM mssg 1 (active) / mssg 2 (data) Disable all outputs 1 1c7c Calibration value out of range mssg 1 (active) / mssg 2 (data) Completely disable oven 4 1c81 CRC invalid mssg 1 (active) / mssg 2 (data) Disable affected oven function 1 1c82 CRC invalid mssg 1 (active) / mssg 2 (data) Disable affected oven function 1 1d11 Sensor resistance >2237 Ω mssg 1 (active) / mssg 3 (data) Disable all cooking functions for cavity 1d12 Sensor resistance >2237 Ω mssg 1 (active) / mssg 3 (data) Disable all cooking functions for cavity 1d21 Sensor resistance >2787 Ω mssg 1 (active) / mssg 3 (data) Disable all cooking functions for cavity 1d22 Sensor resistance >2787 Ω mssg 1 (active) / mssg 3 (data) Disable all cooking functions for cavity 3d11 Sensor resistance > Infinite Ω mssg 1 (active) / mssg 2 (data) Disable all cooking functions for cavity 3d12 Sensor resistance > Infinite Ω mssg 1 (active) / mssg 2 (data) Disable all cooking functions for cavity 3d21 Sensor resistance < 0 Ω mssg 1 (active) / mssg 2 (data) Disable all cooking functions for cavity 3d22 Sensor resistance < 0 Ω mssg 1 (active) / mssg 2 (data) Disable all cooking functions for cavity 3d41 Probe resistance < 0 Ω mssg 1 (active) / mssg 2 (data) Disable all probe functions 3d51 Calibration value out of range mssg 2 Disable all probe functions 4d11 Door switch not closed when mssg 1 Disable Clean and lockout functions 5 door is locked 4d12 Door switch not closed when mssg 1 Disable Clean and lockout functions 5 door is locked 4d21 Reverse Airflow Fan rotation mssg 1 (active) / mssg 2 (data) Disable all cooking functions for cavity (no/low RPM) 4d22 Reverse Airflow Fan rotation mssg 1 (active) / mssg 2 (data) Disable all cooking functions for cavity (no/low RPM) 4d31 Reverse Airflow Fan rotation No change No action (on when should be off) 4d32 Reverse Airflow Fan rotation No change No action (on when should be off) 4d41 Reverse Airflow Fan rotation mssg 1 (active) / mssg 2 (data) Disable all cooking functions for cavity (high RPM) 4d42 Reverse Airflow Fan rotation mssg 1 (active) / mssg 2 (data) Disable all cooking functions for cavity (high RPM) 4d51 Door switch not open or closed mssg 1 (active) / mssg 2 (data) Disable Convect, Clean, and lockout functions 4, 5 Turn off light and disable light from door switch 4d52 Door switch not open or closed mssg 1 (active) / mssg 2 (data) Disable Convect, Clean, and lockout functions 4, 5 Turn off light and disable light from door switch 9d11 Lock switch not closed mssg 1 (active) / mssg 2 (data) Disable Clean and lockout functions 4 9d12 Lock switch not closed mssg 1 (active) / mssg 2 (data) Disable Clean and lockout functions 4 9d21 Unlock switch not closed mssg 1 (active) / mssg 2 (data) Disable Clean and lockout functions 4 9d22 Unlock switch not closed mssg 1 (active) / mssg 2 (data) Disable Clean and lockout functions 4 9d31 Lock and unlock switches both closed mssg 1 (active) / mssg 2 (data) Disable Clean and lockout functions 4 9d32 Lock and unlock switches both closed mssg 1 (active) / mssg 2 (data) Disable Clean and lockout functions 4 Message 1: Message 2: Message 3: FAULT DETECTED PRESS ENTER TO TRY AGAIN FEATURE NOT AVAILABLE PRESS HELP FAULT DETECTED DISABLE POWER TO CLEAR 6 September 2003

Component Testing Information NOTES: 1 Action Taken applies as long as the condition exists. If the condition goes away, the control recovers. 2 3 4 5 6 If there is a cook function or timer active, the function continues. The user cannot edit the function, and [Cancel] will cancel the cook mode. Flash rate: 0.2 seconds on, 0.1 second off. Pressing any key will clear the display until the fault clears and is re-triggered. Action Taken applies until there is a POR (Power On Reset [ hard reset ]). If the control believes the door is locked, it will attempt to unlock it when the function cancels and the cavity temperature cools. Special conditions for latch faults (9dxx): A known good unlock position is defined as when the unlock switch reads closed and lock switch reads open. A known good lock position is defined as when the unlock switch reads open and lock switch reads closed. A faulted switch means the switch input is reading an invalid state, neither open nor closed. Once a latch fault occurs, latch movement is disabled until there is a POR. An error tone will sound if a function requiring a faulted latch is attempted. If at POR, the latch is not at a known good unlock position: If the latch is at a good lock position, it will attempt to unlock when the RTD (Resistance Temperature Device) temperature is below 400 F. If the latch is not at a good lock position, the control will fault. If a latch fault occurs while the RTD is above the lock temperature, the latch will not try to move, but the fault is still logged to EEPROM after the first stage of detection. The Display column for latch faults applies 1) If the latch was moving when the fault occurred; 2) If the latch is already in a known locked state when the fault occurs. LOCK flashes after a fault is detected and until the unlocked position is achieved. The unlock position may be identified by a successful unlock switch closure, or as the result of timing when the unlock switch is not functioning properly. If the last known good position was unlock (e.g. baking, or idle) and a latch fault occurs, the motor is never moved. The fault is logged to EEPROM and is not seen by the user. The detection for latch faults is in two stages. The first stage is to let the control recover without moving the latch. After this: If the latch was previously at a known good unlock position, the latch will not move and the control will fault. If the control was previously in a known good lock position: If the RTD is below 400 F, the latch will attempt to recover to it s proper position (up to three revolutions). If it cannot, the control will fault and the latch will move to a calculated unlock position. If the RTD is at or above 400 F, the control will fault. When the RTD cools to below 400 F, the control will attempt to recover to a good unlock position (up to three revolution). If it cannot, the control will fault and the latch will move to a calculated unlock position. Note: If the unlock position cannot be found, this may result in a second fault, the first fault occurring when the latch request was locked, and the second when the latch request is unlocked. If the latch is moving when the fault occurs, the control will bypass the first stage of detection and immediately try to find it s proper position. If it cannot, the control will fault and the latch will move to a calculated unlock position. Affected DLBs (Double Line Breaks) and loads are disabled during detection. If the control is in a known good unlock position and the lock switch becomes faulted: The control will not fault. If a function requiring latch movement is attempted while the lock switch is faulted, the control will sound an error tone and the function will be disabled. If the control is in a known good lock position and the unlock switch becomes faulted: The control will not fault. After the function is canceled and unlock is attempted, the control will attempt to unlock the latch according to the procedures in these notes. September 2003 7

Wiring Diagram and Schematic 8 September 2003

Wiring Diagram and Schematic September 2003 9