Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Similar documents
KANE-ALERT-CO 2 Monitor with Temperature

AMC-CD2. Human Occupancy Detector INSTRUCTION MANUAL. Please read these instructions completely and carefully before starting.

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

CO2 Monitor Operating Instructions

Operation Manual. Rev. D GEM-II Self-Contained Gas Detector.

esense CO2 Transmitter and Alarm

Operation Manual. Rev. E GEM-MRI. Oxygen Sampling System.

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

CO2 & Oxygen Monitor Operating Instructions Model: RAD

Sirius Technologies, Inc.

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

Model OEM-2 INSTRUCTIONS FOR USE

Document No

RK CO 2 Transmitter Operator s Manual

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

HIn3550 Magnetic Field Monitor User's Manual

! "! # Please read these installation and operating instructions completely and carefully before starting.

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

OWNERS MANUAL MODEL 451 (-101 & -201)

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Warranty Registration

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

RK-02 Multi Point Detector Operator s Manual

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

Dual Laser InfraRed (IR) Thermometer

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

High Temperature InfraRed Thermometer with Laser Pointer

RK / RK CO 2 Detector Operator s Manual

User's Guide. CO 2 Monitor. Model CO200

Oxygen Monitor Operating Manual

User s Manual For Model Aero-551 (Rev. Orig.)

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

For the Safety of Your

User's Guide. Pinless Moisture Meter. Model MO257

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

Environmental Monitoring SmartSlot Card

RK-05 Carbon Monoxide Detector Operator s Manual

M3050 Detector Operator s Manual

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

RK Carbon Monoxide Transmitter Operator s Manual

RK-05 Combustible Gas Transmitter Operator s Manual

VALTRONICS IAQ Monitor

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Owner s Manual. PIR-1 IR Learner


Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

Installation, Operation & Service Manual

PolyGard Controller LGC/LG2-04. Multi-Point Controller Serial Number S00 User Manual Preliminary Version. August 11, 2006

Spy Jeepmeter ope rati ng instructions

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

Mark 25 Ultrapure Water Conductivity Analyzer

CALIBRATABLE 3-FUNCTION THERMO- HYGROMETER USER S MANUAL

VS2000V Veterinary Vital Signs Monitor Operation Manual

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

RK-03 Hydrogen Detector Operator s Manual

C0-210 Carbon Monoxide Probe

M1C. Operator Manual

RECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Operation Manual. Rev. I SCC Self Contained Controller.

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

RK / RK Methane Detector Operator s Manual

MicrOTDR. Optical Fault Locator. User Manual

RK/ RK Carbon Monoxide Detector Operator s Manual

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Operation Manual. Rev ART Infrared Refrigerant Transmitter.

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

RK/ RK Combustible Gas Detector Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

AirGard 385 Fume Hood Monitor

RK/ RK Oxygen Detector Operator s Manual

User Guide. for the Beacon ProActTM 200 System

RK Multi Point Detector Operator s Manual

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

RK Carbon Monoxide Transmitter Operator s Manual

Pocket CO2 Monitor & Data Logger SAN-0001

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

RAM3 Remote Alarm Module

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

Installation and Operations Manual

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

RK Combustible Gas Transmitter Operator s Manual

Model 5190-E Temperature/Humidity Probe

Digital Refrigerator/Freezer Thermometer model 00986

COMBUSTIBLE GAS LEAK DETECTOR PEN

RK Hydrogen Sulfide Transmitter Operator s Manual

Transcription:

Critical Environment Technologies Canada Inc. Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature OPERATION MANUAL REV: A JUNE-2-2008 #145, 7391 Vantage Way Delta, BC V4G 1M3 Canada Phone: 604-940-7007 Fax: 604-940-7044 www.yestek.com 1

2

IMPORTANT NOTE READ AND UNDERSTAND THIS MANUAL PRIOR TO USING THIS INSTRUMENT. CAREFULLY READ THE WARRANTY POLICY, SERVICE POLICY, NOTICES, DISCLAIMERS AND REVISIONS ON THE FOLLOWING PAGES. THIS INSTRUMENT SHOULD BE INSPECTED AND CALIBRATED REGULARLY BY A QUALIFIED AND TRAINED TECHNICIAN. THIS INSTRUMENT HAS NOT BEEN DESIGNED TO BE INTRINSICALLY SAFE. FOR YOUR SAFETY, DO NOT USE IT IN CLASSIFIED HAZARDOUS AREAS (EXPLOSION-RATED ENVIRONMENTS). INSTRUMENT SERIAL NUMBER: PURCHASE DATE: PURCHASED FROM: WARRANTY POLICY CRITICAL ENVIRONMENT TECHNOLOGIES CANADA INC. (FORMERLY YES ENVIRONMENT TECHNOLOGIES INC.) WARRANTS THIS INSTRUMENT TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF EIGHTEEN MONTHS, INCLUDING CO2 SENSOR, FROM THE DATE OF PURCHASE BY THE ORIGINAL OWNER. IF THE PRODUCT SHOULD BECOME DEFECTIVE WITHIN THIS WARRANTY PERIOD, WE WILL REPAIR OR REPLACE, IT AT OUR DISCRETION. THE WARRANTY STATUS MAY BE AFFECTED IF THE INSTRUMENT HAS NOT BEEN USED AND MAINTAINED AS PER THE INSTRUCTIONS IN THIS MANUAL OR HAS BEEN ABUSED, DAMAGED OR MODIFIED IN ANY WAY. THIS INSTRUMENT IS ONLY TO BE USED FOR PURPOSES STATED HEREIN. THE MANUFACTURER IS NOT LIABLE FOR AUXILIARY INTERFACED EQUIPMENT OR CONSEQUENTIAL DAMAGE. DUE TO ONGOING RESEARCH, DEVELOPMENT AND PRODUCT TESTING, THE MANUFACTURER RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. THE INFORMATION CONTAINED HEREIN IS BASED ON DATA CONSIDERED ACCURATE. HOWEVER, NO WARRANTY IS EXPRESSED OR IMPLIED REGARDING THE ACCURACY OF THIS DATA. ALL GOODS MUST BE SHIPPED TO THE MANUFACTURER BY PREPAID FREIGHT. ALL RETURNED GOODS MUST BE PRE-AUTHORIZED BY OBTAINING A RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER. CONTACT THE MANUFACTURER FOR A NUMBER AND PROCEDURES REQUIRED FOR PRODUCT TRANSPORT. 3

SERVICE POLICY CRITICAL ENVIRONMENT TECHNOLOGIES CANADA INC. (CETCI) MAINTAINS AN INSTRUMENT SERVICE FACILITY AT THE FACTORY. SOME CETCI DISTRIBUTORS / AGENTS MAY ALSO HAVE REPAIR FACILITIES, HOWEVER, CETCI ASSUMES NO LIABILITY FOR SERVICE PERFORMED BY ANYONE OTHER THAN CETCI PERSONNEL. REPAIRS ARE WARRANTED FOR 90 DAYS AFTER DATE OF SHIPMENT. SHOULD YOUR INSTRUMENT REQUIRE NON- WARRANTY REPAIR, YOU MAY CONTACT THE DISTRIBUTOR FROM WHOM IT WAS PURCHASED OR YOU MAY CONTACT CETCI DIRECTLY. IF CETCI IS TO DO THE REPAIR WORK, YOU MAY SEND THE INSTRUMENT, PREPAID, TO CRITICAL ENVIRONMENT TECHNOLOGIES CANADA INC., #145, 7391 VANTAGE WAY, DELTA, B.C. V4G 1M3, ATTENTION: SERVICE DEPARTMENT. ALWAYS INCLUDE YOUR RMA #, ADDRESS, TELEPHONE NUMBER, CONTACT NAME, SHIPPING / BILLING INFORMATION AND A DESCRIPTION OF THE DEFECT AS YOU PERCIEVE IT. YOU WILL BE CONTACTED WITH A COST ESTIMATE FOR EXPECTED REPAIRS, PRIOR TO THE PERFORMANCE OF ANY SERVICE WORK. FOR LIABILITY REASONS, CETCI HAS A POLICY OF PERFORMING ALL NEEDED REPAIRS TO RESTORE THE INSTRUMENT TO FULL OPERATING CONDITION. PRIOR TO SHIPPING EQUIPMENT TO CETCI, CONTACT OUR OFFICE FOR AN RMA # (RETURNED MERCHANDISE AUTHORIZATION). ALL RETURNED GOODS MUST BE ACCOMPANIED WITH AN RMA NUMBER. PACK THE EQUIPMENT WELL (IN IT S ORIGINAL PACKING IF POSSIBLE), AS WE CANNOT BE HELD RESPONSIBLE FOR ANY DAMAGE INCURRED DURING SHIPPING TO OUR FACILITY. NOTICES COPYRIGHTS: THIS MANUAL IS SUBJECT TO COPYRIGHT PROTECTION; ALL RIGHTS ARE RESERVED. UNDER INTERNATIONAL AND DOMESTIC COPYRIGHT LAWS, THIS MANUAL MAY NOT BE COPIED OR TRANSLATED, IN WHOLE OR IN PART, IN ANY MANNER OR FORMAT, WITHOUT THE WRITTEN PERMISSION OF CRITICAL ENVIRONMENT TECHNOLOGIES CANADA INC. ALL SOFTWARE WHICH CETCI UTILIZES AND/OR DISTRIBUTES, HOLDS A PROPRIETARY INTEREST AND IS ALSO SUBJECT TO COPYRIGHT PROTECTION AND ALL RIGHTS ARE RESERVED. NO PARTY MAY USE OR COPY SUCH SOFTWARE IN ANY MANNER OR FORMAT, EXCEPT TO THE EXTENT THAT CETCI GRANTS THEM A LICENSE TO DO SO. IF THIS SOFTWARE IS BEING LOADED ONTO MORE THAN ONE COMPUTER, EXTRA SOFTWARE LICENSES MUST BE PURCHASED. 4

DISCLAIMER UNDER NO CIRCUMSTANCES WILL CRITICAL ENVIRONMENT TECHNOLOGIES CANADA INC. (CETCI) BE LIABLE FOR ANY CLAIMS, LOSSES OR DAMAGES RESULTING FROM OR ARISING OUT OF THE REPAIR OR MODIFICATION OF THIS EQUIPMENT BY A PARTY OTHER THAN CETCI SERVICE TECHNICIANS, OR BY OPERATION OR USE OF THE EQUIPMENT OTHER THAN IN ACCORDANCE WITH THE PRINTED INSTRUCTIONS CONTAINED WITHIN THIS MANUAL OR IF THE EQUIPMENT HAS BEEN IMPROPERLY MAINTAINED OR SUBJECTED TO NEGLECT OR ACCIDENT. ANY OF THE FORGOING WILL VOID THE WARRANTY. REVISIONS THIS MANUAL WAS WRITTEN AND PUBLISHED BY CRITICAL ENVIRONMENT TECHNOLOGIES CANADA INC. (THE MANUFACTURER). THE MANUFACTURER MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PURPOSE, WITH RESPECT TO THIS MANUAL. ALL INFORMATION CONTAINED IN THIS MANUAL IS BELIEVED TO BE TRUE AND ACCURATE AT THE TIME OF PRINTING. HOWEVER, AS PART OF IT S CONTINUING EFFORTS TO IMPROVE IT S PRODUCTS AND THEIR DOCUMENTATION, THE MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES AT ANY TIME WITHOUT NOTICE. REVISED COPIES OF THIS MANUAL CAN BE OBTAINED BY CONTACTING CRITICAL ENVIRONMENT TECHNOLOGIES CANADA INC. SHOULD YOU DETECT ANY ERROR OR OMISSION IN THIS MANUAL, PLEASE CONTACT THE COMPANY AT THE FOLLOWING ADDRESS: CRITICAL ENVIRONMENT TECHNOLOGIES CANADA INC. UNIT 145, 7391 VANTAGE WAY DELTA, BC V4G 1M3 CANADA TOLL FREE: 1-877-940-8741 PHONE: 604-940-8741 FAX: 604-940-8745 E-MAIL: FBRITTON@CETCI.COM WEBSITE: WWW.YESTEK.COM WEBSITE: WWW.CRITICAL-ENVIRONMENT.COM IN NO EVENT WILL CRITICAL ENVIRONMENT TECHNOLOGIES CANADA INC., OR IT S OFFICERS OR EMPLOYEES BE LIABLE FOR ANY DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY DEFECT IN ANY MANUAL, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 5

INDEX SECTION DESCRIPTION PAGE IMPORTANT NOTE AND WARRANTY POLICY 3 SERVICE POLICY AND NOTICES 4 DISCLAIMER AND REVISIONS 5 INDEX 6 WELCOME 7 1.0 GENERAL 8 2.0 SPECIFICATIONS 8-9 3.0 DIMENSIONS 10 4.0 INSTRUMENT FEATURES 11-12 5.0 OPERATION 13 5.1 OPERATING MODES 13 5.2 DETAILED OPERATING INSTRUCTIONS 13-16 5.22 OPERATION - MODE ADJUSTMENT 14-16 1.0 ALTI MODE 14 2.0 ALARM MODE 14 3.0 OUTSIDE MODE 15 4.0 CALI MODE 15 5.0 DATA LOGGER MODE 16 6.0 MAX / MIN. MODE 16 7.0 fcfs MODE 16 6

WELCOME Thank you for purchasing the FALCON-II indoor air quality monitor. The FALCON-II is an easy to use, portable, monitoring device for monitoring trends that pertain to indoor air quality. The FALCON-II is equipped with integral CO2 and temperature sensors to aid in verifying readings providing an indication of air quality. Information readings are temporarily written to built-in memory. The instrument may be hand-held or will easily stand on a flat surface. The FALCON-II instruments are manufactured to provide good value to the end user. Calibration and repair is available at our manufacturing facility and through some of our authorized and trained distributors. If after reading through the manual, you have any questions, please do not hesitate to contact our service department for technical support. WHAT YOU GET * INSTRUMENT * 4 X AA ALKALINE BATTERIES * WALL ADAPTER (NORTH AMERICAN WALL PLUG CONFIGURATION) OPERATION MANUAL WHITE, FOAM-LINED CARDBOARD STORAGE SHIPPING BOX 7

1.0 GENERAL The Falcon-II is a rugged, hand-held, battery powered instrument for measuring and displaying Carbon Dioxide (CO2) and Temperature. It operates from internal alkaline batteries or it s own (supplied) wall adapter. 2.0 SPECIFICATIONS Dimensions: Weight: 0.96 X 3.19 X 6.50 (24.3mm X 81.1mm X 165 mm) 9.65 oz (273.6 grams) including batteries General Operating Conditions: Operating Temperature: 32-122 F (0-50 C) 0-95% RH, noncondensing Storage Temperature: -4 to 140 F (-20 to 60 C)) Power: Two power supply types: Battery type: Alkaline, AA X 4 (80 hours) External: 6 VDC from external AC/DC adapter which is included in package (North American wall configuration only) Power Requirement: 160 ma Peak, 15 ma average from 6V Outputs: Sample Method: Warranty: Display: Certifications: Normally Low,100mA max. @ 24 VDC. Adjustable set-point, factory setting is 1000ppm, hysteresis is 50ppm. One RJ-45 Connector Diffusion or flow through (50 ~200 ml/min) 18-months parts & labour (when returned to factory prepaid freight) LCD: Independent CO2 & Temperature readings. Calculates & displays ventilation rates CE LCD Error Messages: ITEM 8 DESCRIPTION Error 3, it is displayed when the temperature being measured is outside of the measurement range. Error 5~6, it is necessary to reset the device. To reset it, turn the instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and turn on. If the error message remains please contact the Service Department for further assistance.

2.0 SPECIFICATIONS, CONT D.. Sensors: CO2 (Carbon Dioxide): NDIR (Non-Dispersive Infrared) Temperature: CO2 SENSOR - NDIR Measurement Range Display Resolution Accuracy Repeatability Temperature Dependence Pressure Dependence Response Time DESCRIPTION 0-10,000 ppm 1ppm at 0~1,000ppm; 5ppm at 1,000~2,000ppm; 10ppm at 2,000~4,000ppm, 20ppm at 4,000~6,000ppm, 40ppm at 6,000~10,000ppm ±50 ppm or ±5% of reading ±20 ppm ±0.1% of reading per C or ±2 ppm per C, whichever is greater, referenced to 25 C 0.13% of reading per mm Hg (Corrected via user input for altitude) <2min for 63% of step change Warm-Up Time <60 seconds at 22 C Calibration Interval 12 months, offset adjustment using single gas at 0-1000 ppm CO2. Full factory calibration available TEMPERATURE SENSOR Temperature Range Display Resolution Display Options Accuracy Response Time DESCRIPTION Display 32 to 122 F (0 to 50 C) 0.1 F (0.1 C) F / C, or Off. Set with Up / Down button ±2 F (±1 C) 20-30 minutes (case must equilibrate with environment) 9

3.0 DIMENSIONS 0.96 24.3mm 6.50 165mm 3.19 81.1mm 10

4.0 INSTRUMENT FEATURES FUNCTION PUSH-BUTTONS: MODE, UP, DOWN, ENTER. (left to right) ON / OFF PUSH-BUTTON WALL ADAPTER SOCKET LCD DISPLAY LED INDICATOR TEST GAS INLET OPENING FLIP-DOWN STAND ALKALINE BATTERY ACCESS DOOR 11

4.0 INSTRUMENT FEATURES, CONT D.. Changing Alkaline Batteries: 12

5.0 OPERATION The Falcon-II is a rugged, hand-held, battery powered instrument for measuring and displaying Carbon Dioxide (CO2) and Temperature. It operates from internal alkaline batteries or it s own (supplied) wall adapter. 5.1 OPERATING MODES MODE DESCRIPTION LCD DISPLAY ALTI ALARM OUTSIDE CALI DATA LOGGER MAX-MIN rcfs Compensate for the effect of pressure changes by inputting the appropriate altitude of the location where the instrument is being used. Alarm when CO2 concentration exceeds one threshold alarm. Alarm level can be changed through the keypad / menu. The audible alarm can be switched on/off through the keypad / menu when the speaker icon flashes Modify the concentration of outside CO2 for defining the ventilation rate Calibrate the sensor when the reading deviates from the actual CO2 concentration Show CO2 and temperature records in the past 24-hours Show the Max and Min readings before being cleared off or before switching off Recover the factory Settings, if the device cannot show accurate readings 13

5.2 DETAILED OPERATING INSTRUCTIONS PowerOn Press the Power button (1) to turn on the device after placing 4 AA batteries into the battery holder or AC adapter plug into the DC socket. Once instrument has been powered up, the CO2 reading will show after 15 seconds of warm up. WarmUp It takes approximately 1-minute before WARM-UP disappears from the LCD. All the functions will not respond during the warm up period. UserMode After warm up, the device will stabilize and display the normal CO2 reading in the upper part of the LCD) and remain visible at all times. Temperature and Ventilation Rates will be shown in the lower portion of the LCD. The Up/Down button (4/3) allows you to scroll through the Temperature and Ventilation Modes. When pressing the Up button, the lower display will go through the following sequence: TempºC -> TempºF -> Vent Rate lps -> Vent Rate cfm/p. NOTE: lps refers to Liter Per Second Per Person; cfm/p refers to Cubic Feet Per Minute Per Person 5.22 OPERATION - MODE ADJUSTMENT 1.0 ALTI Mode 1.1. Press the Mode Button (5), ALTI flashes 1.2. Press Mode (5) to alter between m (meters) and ft (feet). 1.3. Press Up/Down (4/3) to adjust the altitude (Step=100m/500ft) 1.4. Press the Enter Button (2), save or leave the ALTI Mode, and return to User Mode. 2.0 ALARM Mode 2.1. Adjust the alarm level 2.1.1. Press the Mode button (5), until ALARM flashes 2.1.2. Press the Enter Button (2), CO2 icon flashes. 2.1.3. Press Up/Down (4/3) to adjust the alarm level ( 1,000 ppm, interval is ± 100ppm; <1,000 ppm, interval is ±50 ppm) 2.1.4. Press the Enter (2), save the setting and return to the User Mode. 2.2. Turn ON/OFF the ALARM 2.2.1. Press the Mode button (5), until Speaker Icon flashes 2.2.2. Press Enter Button (2) 2.2.3. Press Up/Down (4/3) to turn the ALARM on or off 2.2.4. Press the Enter (2), save the setting and return to the User Mode. 14

5.2 DETAILED OPERATING INSTRUCTIONS, CONT D.. 5.22 OPERATION - MODE ADJUSTMENT, CONT D.. 3.0 OUTSIDE Mode NOTE: Ventilation Rate Ventilate rate represents how much air is introduced into the indoor space from the outside. Low values indicate low ventilation rates and potentially poor air quality. High levels indicate excessive ventilation and potential excessive energy usage. To obtain an accurate measurement, readings should be taken 2~3 hours after occupancy has stabilized in a space or at a peak in daily CO2 concentrations. With indoor air quality control, CO2 value is an indicator of ventilation rate. 400 ppm (Parts Per Million) is the default CO2 concentration outside (according to ASHRAE: American Society of Heating, Refrigeration and Air conditioning Engineers). 3.1. Press the Mode button (5), until OUTSIDE flashes. 3.2. Press Enter (2), to show OUTSIDE CO2 and PPM flashes. Press Up/Down (4/ 3) to adjust the reading. 3.3. Press the Enter (2), save the setting and return to the User Mode. After modification, the VENT Rate will change. 4.0 CALI Mode The CO2 monitor has been calibrated at the factory and should be recalibrated every 12-months with a specified concentration of CO2. Sensor drift usually occurs in linearity. To perform calibration, follow the steps below. 4.1. If battery icon shows low power, replace batteries before attempting to calibrate or use AC adapter. 4.2. Press the Mode button (5), until CALI flashes. 4.3. Press Enter (2), CALI is shown on the display 4.4. Adjust the lower display to ambient CO2 value by pressing the Up/Down (4/ 3) Button. 4.5. Press Mode button (5) for more than 10 seconds. CALIBRATING flashes. Calibration will be finished after 5-minutes and the LCD will indicate PASS. If LCD indicates FAIL, repeat the calibration. 4.6. Press Enter (2), and return to the User Mode 15

5.2 DETAILED OPERATING INSTRUCTIONS, CONT D.. 5.0 DATA LOGGER Mode The Falcon-OO has a built-in data logger, which can provide users with CO2 and temperature readings within the past 24 hours. 5.1. Press the Mode button(5), until DATALOGGER flashes 5.2. Press Enter(2),CO2 and Temperature shows up Press Up/Down(4/3) to page up/down the reading. 5.3. Press the Enter(2), return to User Mode 6.0 MaxMin Mode The Falcon-II has a built-in Max-Min mode, which can provide users with the Maximum and Minimum CO2 readings since the instrument was last switched on. 6.1. Press the Mode button(5), until MAX MIN flashes. 6.2. Press Enter button(2), MAX and MIN CO2 reading shows alternating. 6.3. CLR will flash if press Up/Down(4/3). Press Enter(2),to CLEAR the MAX and MIN record. 6.4. Press Mode or Enter(5), return to the User Mode. 7.0 rcfsmode: If the user sets or calibrates the sensor wrong, you can recover the factory setting. 7.1. Press the Mode button(5), until rcfs flashes on the lower display 7.2. Press Enter(2), no shows on the upper display 7.3. Press Up/Dow(4/3), no change to yes, Press Enter(2), Factory Setting will reload, return to the User Mode; 7.4. Press Mode(5), leave rcfs Mode, return to the User Mode SPECIFICATIONS (Preliminary Version) 16