SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

Similar documents
POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT OBSTRUCTION LIGHTS POL INCANDESCENT POINTSPEC SERIES

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIPORT INSET LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

POINT FLASHING BEACON PFB EX LED HAZARDOUS AREA CLASS I, DIVISION 2

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Vigilant LED Based Obstruction Lights

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Vigilant LED Based Obstruction Lights

Tower & Obstruction Lighting

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

SECTION EXTERIOR LIGHTING

Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

Heliport & Helideck Lighting System. For Non Hazardous and Hazardous Locations. Option: Marine Treatment for superior corrosion protection

Model 9001, Alarm

Model 9001, Alarm

Vigilant LED Based Obstruction Lights

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

INSTALLATION INSTRUCTIONS

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

4300 WINDFERN RD SUITE 100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

Hardwired Model Shown. Installation & Operation Manual for WarmlyYours Infinity Towel Warmers

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

Booster Power Supply Manual

NXM2G Installation and Operating Manual

TLM-1 TOWER LIGHT MONITOR V3.0. INSTALLATION and OPERATING INSTRUCTIONS

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance.

Installation Instruction Manual

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

180 Degree Ceiling Mounted Occupancy Sensors

Remote Relay Module (RRM)

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Technical Specification VFD

Thermal Stability Systems

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

PowerWave 2 Busway System

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

INSTALLATION INSTRUCTIONS

Airfield lighting. Product Brochure

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Introduction to Flow Switch

Beacon 410A Gas Monitor Operator s Manual

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Installation and Op er a tion Man u al

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Model 4001 Series Single Channel Controller

Relay Panel and Relay Panel Module Wiring and installation manual Light is OSRAM

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

IntelliLED TM. Daylight Harvesting Sensor (DLH): User Guide

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

Single stage operation oil burner

1. PURPOSE. This advisory circular (AC) contains the Federal Aviation Administration (FAA) specification for obstruction lighting equipment.

Heliport Perimeter Light Type MIJ

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Mark 25 Ultrapure Water Conductivity Analyzer

GLED INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Installation Instructions CS3 Three Phase Solid State Relay

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

SECTION LOW VOLTAGE LIGHTING CONTROLS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

Installation Manual. Models 99168, 99169, 99170

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Type 2 Models. Owner s Guide and Installation Manual. English Español

10810 W. LITTLE YORK RD #130 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Operating Instructions

AWL AIRCRAFT WARNING LIGHT LIOL-B TYPE OPERATION AND MAINTENANCE MANUAL

Dialight Obstruction LED Solutions

Important Safety Instructions. Important Safety Instructions

LC3000 Level Controller Installation and Maintenance Instructions

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

Panel Mounted Heat Exchangers by Dantherm, Inc.

3M Benchtop Air Ionizer 963E. User s Guide

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

IMPORTANT SAFETY INFORMATION:

ecolor Graze Powercore Linear LED surface light for wall washing and grazing

MENU. Steamist Digital Sauna Control Models: S170-1 and S Steamist Digital Sauna Control. Contents. 1. Steamist Digital Sauna Control

Douglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7

Transcription:

SUPPLEMENTAL INSTRUCTION SHEET POL-21004-S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM IS21004-S2 24 April 2014 Page 1 of 4 The POL-21004-S2 is a single, steady burning obstruction light with an alarm relay and non-isolated alarm line. Upon failure of the light, the relay transfers the POL s Line voltage to the purple alarm wire. This is not an isolated alarm line; if line power fails, this alarm line fails. This alarm line is normally wired to an external alarm lamp, pilot light or other user supplied alarm. It can supply five (5) Amps maximum. CATALOG NUMBERING SYSTEM Point Type - Power Photometric - Color - Mounting & Entries - Style - Options Specification POL-21004 1: 120V 1 F: FAA & ICAO B R: Red 34B: ¾-inch, Bottom S2: Non-Isolated Alarm NC: NVG Compatible 2: 220V 2 B: ICAO B 10B: 1-inch, Bottom 6: 277V 3 & Transport Canada 34F: ¾-inch, Feed-thru 10F: 1-inch, Feed-thru M20B: Metric, Bottom M25B: M25, Bottom IMPORTANT: THE POL FIXTURE IS FACTORY SEALED. REMOVING THE CLAMP BAND, LENS OR IN ANY WAY ENTERING THE SPACE CONTAINING THE POWER SUPPLY AND LED ARRAY WITHOUT INSTRUCTIONS FROM THE FACTORY, VOIDS THE WARRANTY AND MAY RESULT IN PREMATURE FAILURE OF THE LIGHT. THE WIRE LEADS ARE SEALED AT THE ENTRY POINT TO THE LED HEAD SUBASSEMBLY. BREAKING THE SEAL OF THE WIRES VOIDS THE WARRANTY. ALL POL LED UNITS ARE INDIVIDUALLY TESTED AT THE FACTORY BEFORE SHIPMENT. ANY ATTEMPT TO DISASSEMBLE OR TO FIELD TEST THE FUNCTIONS OF THE LIGHT ASSEMBLY VOIDS THE WARRANTY. WARNING: CHANGES OR MODIFICATIONS TO THIS UNIT NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT. WARNING: DO NOT INSTALL AIR TERMINALS (LIGHTNING RODS) NEAR OR ON ANY POINT LIGHTING FIXTURES. AIR TERMINALS WILL INCREASE THE POSSIBILITY OF FAILURES AND WILL VOID THE FACTORY WARRANTY. FIXTURE GROUND WIRES MUST NOT BE CONNECTED TO BUILDING/TOWER LIGHTNING PROTECTION SYSTEM DOWN CONNECTORS. IMPORTANT NOTICE The installer assumes full responsibility for the proper application and safe installation of this unit in accordance with these instructions, the National Electric Code, and all other state and local codes and practices. POINT LIGHTING CORPORATION accepts no responsibility for damages to property or injury to personnel for the improper use of this product or its failure under any circumstances. POINT LIGHTING CORPORATION s warranty is limited to the replacement of the defective unit only if the failure is the result of a manufacturing defect.

IS21004-S2 24 April 2014 Page 2 of 4 INSTALLATION INSTRUCTIONS WARNING: TURN OFF THE ELECTRICITY AT THE SOURCE BEFORE INSTALLATION. The fixture is shipped assembled. Thread the POL's hub to the properly sized conduit. The neutral (zero) wire is white. Note: For nominal 220v fixtures, the neutral (zero) wire is blue. Splice the neutral wire to the system neutral (zero). Splice the black wire to the black system line. The green/yellow wire is the fixture s ground; splice it to the system ground. Make splices using proper electrical practices in suitable splice box per NEC and local codes. The POL must be leveled so the fixture is in a vertical position with its base perpendicular to the mounting surface. If necessary, loosen the three screws that secure the upper head subassembly to the conduit, adjust the position as required and retighten the screws. REPLACEMENT PARTS PART NUMBER DESCRIPTION QTY PL10799-1 Relay Alarm 120V 1 PL10799-2 Relay Alarm 220V 1 PL210R4-R-xx-04-xx See Replacement Head Numbering System 1 REPLACEMENT HEAD NUMBERING SYSTEM PL210R4 R xx 04 xx SERIES/MODEL OPTION NC: NVG COMPATIBILITY FIXTURE 1: 120VAC 2: 220VAC 6: 277VAC ARRAY TYPE F: FAA & ICAO A B: ICAO B & TRANSPORT CANADA

IS21004-S2 24 April 2014 Page 3 of 4 POWER CONSUMPTION PER POL LED LIGHT HEAD Array Type Voltage Watts ma VA -1F FAA & ICAO A 120 3.48 41.8 5-2F FAA & ICAO A 220 4.17 23.85 5.8-6F FAA & ICAO A 277 4.09 25.27 7-1B ICAO B & Transport Canada 120 6.9 63 7.6-2B ICAO B & Transport Canada 220 7.1 34 7.5-6B ICAO B & Transport Canada 277 7.5 34 9.4-1F-NC FAA & ICAO A NC Option 120 4.3 40 4.8-2F-NC FAA & ICAO A NC Option 220 4.5 23 5-6F-NC FAA & ICAO A NC Option 277 4.9 22 6-1B-NC ICAO B & Transport Canada NC Option 120 7.7 73 8.7-2B-NC ICAO B & Transport Canada NC Option 220 8 38 8.4-6B-NC ICAO B & Transport Canada NC Option 277 8.3 32 9 POL-21004-S2 Dimensions: Inches (mm) Depth = 5 (127)

IS21004-S2 24 April 2014 Page 4 of 4 WIRING DIAGRAM POL-21004-S2

INSTRUCTION SHEET POL-21004 POINT OBSTRUCTION LIGHT IS21004 11 Feb 2013 Page 1 of 4 The POL PointSpec series of red LED aviation obstruction lights presents the highest grade technical features and the most options available in the industry. POL steady-burning obstruction lights are used to mark tall structures that present hazards to air navigation. At night, these lights warn pilots when installed in accordance with FAA AC 70/7460-1 and applicable FCC and ICAO rules. Use the PPC photoelectric controller or option -P to provide automatic activation at dusk in accordance with FAA specifications. CATALOG NUMBERING SYSTEM Point Type - Power Photometric Standard - Color - Mounting & Entries - Options POL-21004 1: 120v 1 F: FAA & ICAO A R: Red 34B: 3/4-inch NPT Bottom -S: Single 2: 220v 2 B: ICAO B 10B: 1-inch NPT Bottom -NC: NVG Compatible 6: 277v 3 &Transport Canada -MT: Marine Treatment Note 1: 120 VAC 50/60 Hz (+/- 20%) Note 2: 220 VAC 50/60 Hz (176-250V) Note 3: 277 VAC 50/60 Hz (+/-5%) CONFORMS TO: UL STD 1598 UL STD 1598A CERTIFIED TO: 3030033 CSA STD C22.2 No. 250.0 POINT OBSTRUCTION LIGHT POL-21004-1F-R-34B-S OUTLINE DRAWING POL-21004-1F-34B-S IMPORTANT NOTICE The installer assumes full responsibility for the proper application and safe installation of this unit in accordance with these instructions, the National Electric Code, and all other state and local codes and practices. POINT LIGHTING CORPORATION accepts no responsibility for damages to property or injury to personnel for the improper use of this product or its failure under any circumstances. POINT LIGHTING CORPORATION s warranty is limited to the replacement of the defective unit only if the failure is the result of a manufacturing defect.

IS21004 11 Feb 2013 Page 2 of 4 WARNING: TURN OFF THE ELECTRICITY AT THE SOURCE BEFORE INSTALLATION. IMPORTANT: THE POL FIXTURE IS FACTORY SEALED. REMOVING THE CLAMP BAND, LENS OR IN ANY WAY ENTERING THE SPACE CONTAINING THE POWER SUPPLY AND LED ARRAY WITHOUT INSTRUCTIONS FROM THE FACTORY, VOIDS THE WARRANTY AND MAY RESULT IN PREMATURE FAILURE OF THE LIGHT. THE WIRE LEADS ARE SEALED AT THE ENTRY POINT TO THE LED HEAD SUBASSEMBLY. BREAKING THE SEAL OF THE WIRES VOIDS THE WARRANTY. ALL POL LED UNITS ARE INDIVIDUALLY TESTED AT THE FACTORY BEFORE SHIPMENT. ANY ATTEMPT TO DISASSEMBLE OR TO FIELD TEST THE FUNCTIONS OF THE LIGHT ASSEMBLY VOIDS THE WARRANTY. WARNING: CHANGES OR MODIFICATIONS TO THIS UNIT NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT. WARNING: DO NOT INSTALL AIR TERMINALS (LIGHTNING RODS) NEAR OR ON ANY POINT LIGHTING FIXTURES. AIR TERMINALS WILL INCREASE THE POSSIBILITY OF FAILURES AND WILL VOID THE FACTORY WARRANTY. FIXTURE GROUND WIRES MUST NOT BE CONNECTED TO BUILDING/TOWER LIGHTNING PROTECTION SYSTEM DOWN CONNECTORS. INSTALLATION INSTRUCTIONS 1) The fixture is shipped assembled. Thread the POL's hub to the properly sized conduit. OUTLINE DRAWING

IS21004 11 Feb 2013 Page 3 of 4 2) Electrical connections are to be performed in a suitable junction box. The neutral (zero) wire is white. Note: For nominal 220V fixtures, the neutral (zero) wire is blue. Splice the neutral wire to the system neutral (zero). Splice the black wire to the black system line. The green/yellow wire is the fixture s ground; splice it to the system ground. Make splices using proper electrical practices in suitable splice box per NEC and local codes. WIRING DIAGRAM 3) The POL must be leveled so the lamp is in a vertical position base-down perpendicular to the mounting surface. If necessary, loosen the three screws that secure the upper head subassembly to the conduit, adjust the position as required and retighten the screws.

IS21004 11 Feb 2013 Page 4 of 4 POWER CONSUMPTION PER POL LED LIGHT HEAD Array Type Voltage Watts ma VA -1F FAA & ICAO A 120 3.48 41.8 5-2F FAA & ICAO A 220 4.17 23.85 5.8-6F FAA & ICAO A 277 4.09 25.27 7-1B ICAO B & Transport Canada 120 6.9 63 7.6-2B ICAO B & Transport Canada 220 7.1 34 7.5-6B ICAO B & Transport Canada 277 7.5 34 9.4-1F-NC FAA & ICAO A NC Option 120 4.3 40 4.8-2F-NC FAA & ICAO A NC Option 220 4.5 23 5-6F-NC FAA & ICAO A NC Option 277 4.9 22 6-1B-NC ICAO B & Transport Canada NC Option 120 7.7 73 8.7-2B-NC ICAO B & Transport Canada NC Option 220 8 38 8.4-6B-NC ICAO B & Transport Canada NC Option 277 8.3 32 9